HPB/HPA User Manual
10 www.honeywell.com
•REPEAT THE READ CONTINUOUS PRESSURE STEP ABOVE
Notice the slower output rate of one sample every 2 seconds.
•TRY OTHER COMMANDS
Experiment with other commands to become familiar with the command structures. A short overview of
each command with input and response examples is shown in Section 3 Commands –Quick Reference.
See Section 5—Commands for complete command descriptions. Re-apply the power or send an
IN=RESET command to revert to EEPROM default settings. Until an SP=ALL command is executed, no
changes will be stored in the EEPROM.
2.7 COMMAND FUNCTIONAL GROUPS
•PRESSURE DISPLAY UNITS —HPB reads out psi, in wc, mm Hg, etc.
DU Set pressure units for output readings—any one of 13 common units (See Section 8)
U= Specify a user supplied unit of measure
•TEMPERATURE
T1 Single °C
T2 Continuous °C
T3 Single °F
T4 Continuous °F
•RS-232/RS-485 BUS PARAMETERS
BP Changes baud rate and parity
ID Assign device ID and group addresses
M= Select alternate message Headers [RS-485 only]
SI Synchronize Integration cycles among units [RS-485 only]
TO Set Transceiver Operating parameters
•OUTPUT READING AND RATE—Speed up or slow down output rate
Single Reading Commands
P1 Single pressure reading...ASCII format
P3 Single pressure reading...binary format
T1 Single temperature reading...°C
T3 Single temperature reading...°F
Continuous Readings Commands
P2 Continuous pressure readings...ASCII format
P4 Continuous pressure readings...binary format
T2 Continuous temperature readings...°C
T4 Continuous temperature readings...°F
Integration Time Commands —Changes pressure reading response time
DS Set deadband and sensitivity parameters
I= Set pressure integration time, and sampling rate
S2 Set threshold level for 2X speed shift
S5 Set threshold level for output within any 50 msec period
SI Synchronize pressure Integration cycles
Idle Count Command —Changes pressure reading response time
IC Set number of idle integration cycles
Reading Response To Changes In Input Pressure—Filters small changes
S2 Set threshold level for 2X speed shift
S5 Set threshold level for output within any 50 msec period
RR Set number of identical readings to skip
OP Transmit all readings or only changed readings