manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Security System
  8. •
  9. Honeywell Notifier NFS2-640/E User manual

Honeywell Notifier NFS2-640/E User manual

Other manuals for Notifier NFS2-640/E

1

Other Honeywell Security System manuals

Honeywell Optiflex Interactive User manual

Honeywell

Honeywell Optiflex Interactive User manual

Honeywell Esser 804950 User manual

Honeywell

Honeywell Esser 804950 User manual

Honeywell V4000 User manual

Honeywell

Honeywell V4000 User manual

Honeywell 702 Service manual

Honeywell

Honeywell 702 Service manual

Honeywell Code Encryptor II User manual

Honeywell

Honeywell Code Encryptor II User manual

Honeywell LYNX TouchL5200 Series User manual

Honeywell

Honeywell LYNX TouchL5200 Series User manual

Honeywell Gamewell-FCI E3 Series User manual

Honeywell

Honeywell Gamewell-FCI E3 Series User manual

Honeywell VISTA 15P - Ademco 6 Zone Control Panel Operating instructions

Honeywell

Honeywell VISTA 15P - Ademco 6 Zone Control Panel Operating instructions

Honeywell VISTA-128FBPT User manual

Honeywell

Honeywell VISTA-128FBPT User manual

Honeywell Galaxy 2-44 User manual

Honeywell

Honeywell Galaxy 2-44 User manual

Honeywell Friedland FGGA04 Series User manual

Honeywell

Honeywell Friedland FGGA04 Series User manual

Honeywell Lynx Plus Series Operating instructions

Honeywell

Honeywell Lynx Plus Series Operating instructions

Honeywell VISTA-128BPT Installation guide

Honeywell

Honeywell VISTA-128BPT Installation guide

Honeywell Galaxy 2-44+ User manual

Honeywell

Honeywell Galaxy 2-44+ User manual

Honeywell NetAXS NX4S1 User manual

Honeywell

Honeywell NetAXS NX4S1 User manual

Honeywell Gamewell-FCI MS-95 User manual

Honeywell

Honeywell Gamewell-FCI MS-95 User manual

Honeywell X-618 Quick start guide

Honeywell

Honeywell X-618 Quick start guide

Honeywell First Alert FA130CP User manual

Honeywell

Honeywell First Alert FA130CP User manual

Honeywell Lynx Touch L5100 User manual

Honeywell

Honeywell Lynx Touch L5100 User manual

Honeywell Ademco VISTA-50P Assembly instructions

Honeywell

Honeywell Ademco VISTA-50P Assembly instructions

Honeywell Gamewell-FCI Velociti MS-7AF User manual

Honeywell

Honeywell Gamewell-FCI Velociti MS-7AF User manual

Honeywell LYNX Touch L5210 Series User manual

Honeywell

Honeywell LYNX Touch L5210 Series User manual

Honeywell LYNX Touch Security System User manual

Honeywell

Honeywell LYNX Touch Security System User manual

Honeywell LYNX User manual

Honeywell

Honeywell LYNX User manual

Popular Security System manuals by other brands

Polon-Alfa 4000 Installation and maintenance manual

Polon-Alfa

Polon-Alfa 4000 Installation and maintenance manual

Nexcom NViS 14162 Series user manual

Nexcom

Nexcom NViS 14162 Series user manual

Eminent EM8670 Quick install

Eminent

Eminent EM8670 Quick install

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

urmet domus

urmet domus alpha 1060 INSTALLATION AND USE BOOKLET

SmartPool YardGuard YG03 manual

SmartPool

SmartPool YardGuard YG03 manual

DSC PC5964 Mounting instructions

DSC

DSC PC5964 Mounting instructions

Secure USAB-1 operating instructions

Secure

Secure USAB-1 operating instructions

B&B 480 SERIES Operation & maintenance manual

B&B

B&B 480 SERIES Operation & maintenance manual

ADEMCO VISTA-20P Series Installation and setup guide

ADEMCO

ADEMCO VISTA-20P Series Installation and setup guide

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

FRIEDLAND MA10 Installation and operating instructions

FRIEDLAND

FRIEDLAND MA10 Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NFS2-640/E OPERATING INSTRUCTIONS
This sheet must be framed and mounted adjacent to the control panel.
NFS2-640/E Operator’s Instructions — P/N 52744:A ECN 06-165 12/28/2006
Section 1 Operating Information
Normal Standby Operation.
1. Green POWER indicator lit steadily.
2. Red FIRE ALARM indicator off.
3. Yellow TROUBLE indicators off.
Alarm Condition.
1. Red FIRE ALARM indicator lit.
2. Alarm signaling devices activated.
3. Option module (remote station or supplementary alarm relay) acti-
vated.
4. Alarm information visible on LCD display.
Alarm Reset. After locating and correcting the alarm condition,
reset the control panel by pressing the SYSTEM RESET switch.
Trouble Conditions. Activation of trouble signal under normal
operation indicates a condition that requires immediate attention.
Contact your local service representative. Silence the audible signal
by pressing the ACKNOWLEDGE/SCROLL DISPLAY switch. The trouble
indicator will remain illuminated.
Section 2 Switch Functions
Acknowledge/Scroll Display. This silences the piezo
sounder and changes all flashing conditions to steady. Only one press
is necessary, regardless of the number of new alarms, troubles, or
supervisory signals. If the piezo is silenced, it sends an acknowledge
message to the printer and history file. Acknowledge also automati-
cally sends a special command to silence piezo sounders on the
FDU-80 and ACS-series annunciators.
Signal Silence. SIGNAL SILENCE performs all the functions of
ACKNOWLEDGE. In addition, if an alarm exists, it turns off all silence-
able circuits and illuminates the SIGNALS SILENCED indicator. It also
sends a SIGNALS SILENCED message to the LCD display, printer, and
history file. A subsequent alarm will then resound the system.
Notes:
1. This unit is programmed to inhibit signal silence for ____seconds.
2. This unit is programmed to automatically silence alarm signal after
_____ minutes.
Drill. The NFS2-640/E waits for the Drill switch to be pressed for
2 seconds (to prevent accidental activations), then turns on all silence-
able circuits (all FCM-1 modules/bell circuits that are programmed
silenceable), and turns off the Signals Silenced LED. It sends a Drill
Activated message to the LCD display, FDU-80, printer, and History
file.
System Reset. Resets the control panel in standalone applica-
tions. Resets panel when enabled in network applications.
Lamp Test. Press and hold the switch to lamp-test the LEDs.
Section 3 LED Indicators
Controls Active. Green LED which illuminates when the panel
assumes control of local operation as primary display; turns off when
another panel assumes control of local operation.
Power. Green LED which illuminates when primary power is
applied to the control panel.
Pre-Discharge. Red LED lights when any of the releasing zones
have been activated, but have not yet discharged a releasing agent;
turns off when no releasing zones are in the pre-discharge state.
Discharge. Red LED lights when any of the releasing zones are
active and in the process of discharging a releasing agent; turns off
when no releasing zones are discharging a releasing agent.
Abort Active. Yellow LED lights when an abort switch has been
activated; turns off when an abort switch has been pressed and its
timer is still counting down. Activation of a Manual Release Switch
will override Predischarge Delay and override an active Abort Release
Switch, resulting in an immediate agent release.
Fire Alarm. Red LED that flashes when one or more alarms occur.
Illuminates steadily after alarms are acknowledged; turns off when
SYSTEM RESET is pressed after alarm clears.
Pre-Alarm. Red LED that flashes when a pre-alarm threshold is
reached. The LCD display indicates if it is an ALERT or ACTION
pre-alarm.
Security. Blue LED that illuminates for a security alarm. LED
turns off after the alarm clears and SYSTEM RESET is pressed.
Supervisory. Yellow LED that flashes when a Supervisory, Haz-
ard Alert or Tamper condition occurs, such as a sprinkler valve tamper
condition. The LED turns off when the Supervisory condition clears.
The Hazard Alert or Tamper indication will latch until reset.
System Trouble. Yellow LED that flashes when one or more
troubles occur. Goes on steadily when ACKNOWLEDGE is pressed, and
turns off when all trouble conditions are cleared. Will illuminate if the
microprocessor watchdog timer fails (CPU FAIL).
Signals Silenced. Yellow LED that illuminates after SIGNALS
SILENCED has been pressed. Turns off when DRILL or SYSTEM RESET
is pressed.
Point Disabled. Yellow LED that illuminates when one or more
points are disabled. The LCD will indicate which points have been
disabled. Turns off when points are re-enabled.
Section 4 Audible Tone Indicator
Alarm. A continuous sounding tone.
Trouble/Security. A slow, pulsating tone signal having an equal
on and off time.
Supervisory. A fast, pulsating tone signal having an equal on and
off time.
Section 5 Periodic Testing and Maintenance
To ensure proper and reliable operation, system inspection and testing
should be scheduled monthly, or as required by NFPA 72 or local fire
codes. A qualified Service Representative should perform testing.
Before Testing: Notify fire department and/or central alarm
receiving station if alarm condition is transmitted. Notify facility per-
sonnel of the test so alarm sounding devices are ignored during the test
period.
After Testing: Notify all fire, central station, and/or building per-
sonnel when testing is complete.
Section 6 Audio/Telephone System Information
See DVC Operating Instructions!
Section 7 Local Service Representative:
NAME: ________________________________________________
ADDRESS: _____________________________________________
TELEPHONE NUMBER: ________________________________