manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Security System
  8. •
  9. Honeywell Notifier NFS2-640/E User manual

Honeywell Notifier NFS2-640/E User manual

Other manuals for Notifier NFS2-640/E

1

Other Honeywell Security System manuals

Honeywell Ademco VISTA-20PCN Operating instructions

Honeywell

Honeywell Ademco VISTA-20PCN Operating instructions

Honeywell Lyric User manual

Honeywell

Honeywell Lyric User manual

Honeywell LYNX Touch Security System User manual

Honeywell

Honeywell LYNX Touch Security System User manual

Honeywell X-618 User manual

Honeywell

Honeywell X-618 User manual

Honeywell ADEMCO VISTA-15PSIA Assembly instructions

Honeywell

Honeywell ADEMCO VISTA-15PSIA Assembly instructions

Honeywell Ademco Vista-48 series User manual

Honeywell

Honeywell Ademco Vista-48 series User manual

Honeywell Galaxy 2 Series User manual

Honeywell

Honeywell Galaxy 2 Series User manual

Honeywell Fire-Lite Alarms W-BG12LX(A) User manual

Honeywell

Honeywell Fire-Lite Alarms W-BG12LX(A) User manual

Honeywell VISTA-128BP User manual

Honeywell

Honeywell VISTA-128BP User manual

Honeywell Fire-Lite Alarms ES-200X Owner's manual

Honeywell

Honeywell Fire-Lite Alarms ES-200X Owner's manual

Honeywell Apex Destiny 4100 User manual

Honeywell

Honeywell Apex Destiny 4100 User manual

Honeywell AlarmNet 360 Reference guide

Honeywell

Honeywell AlarmNet 360 Reference guide

Honeywell LYNX Touch L7000 Series User manual

Honeywell

Honeywell LYNX Touch L7000 Series User manual

Honeywell VISTA-32FBPT User manual

Honeywell

Honeywell VISTA-32FBPT User manual

Honeywell LYNX Touch Series User manual

Honeywell

Honeywell LYNX Touch Series User manual

Honeywell ADEMCO LYNXR-ENSIA User manual

Honeywell

Honeywell ADEMCO LYNXR-ENSIA User manual

Honeywell Ademco VISTA-20P User manual

Honeywell

Honeywell Ademco VISTA-20P User manual

Honeywell 032211.17 User manual

Honeywell

Honeywell 032211.17 User manual

Honeywell Domonial User manual

Honeywell

Honeywell Domonial User manual

Honeywell SF340F User manual

Honeywell

Honeywell SF340F User manual

Honeywell 013002 User manual

Honeywell

Honeywell 013002 User manual

Honeywell Ademco VISTA-50PUL User manual

Honeywell

Honeywell Ademco VISTA-50PUL User manual

Honeywell ADEMCO VISTA-10P Owner's manual

Honeywell

Honeywell ADEMCO VISTA-10P Owner's manual

Honeywell LYNX Touch L7000 Series User manual

Honeywell

Honeywell LYNX Touch L7000 Series User manual

Popular Security System manuals by other brands

Inner Range Concept 2000 user manual

Inner Range

Inner Range Concept 2000 user manual

Climax Mobile Lite R32 Installer's guide

Climax

Climax Mobile Lite R32 Installer's guide

FBII XL-31 Series installation instructions

FBII

FBII XL-31 Series installation instructions

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Johnson Controls

Johnson Controls PENN Connected PC10 Install and Commissioning Guide

Aeotec Siren Gen5 quick start guide

Aeotec

Aeotec Siren Gen5 quick start guide

IDEAL Accenta Engineering information

IDEAL

IDEAL Accenta Engineering information

Swann SW-P-MC2 Specifications

Swann

Swann SW-P-MC2 Specifications

Ecolink Siren+Chime user manual

Ecolink

Ecolink Siren+Chime user manual

Digital Monitoring Products XR150 user guide

Digital Monitoring Products

Digital Monitoring Products XR150 user guide

EDM Solution 6+6 Wireless-AE installation manual

EDM

EDM Solution 6+6 Wireless-AE installation manual

Siren LED GSM operating manual

Siren

Siren LED GSM operating manual

Detection Systems 7090i Installation and programming manual

Detection Systems

Detection Systems 7090i Installation and programming manual

Se-Kure Controls MicroMini SK-4841 instructions

Se-Kure Controls

Se-Kure Controls MicroMini SK-4841 instructions

Siemens FDM273 manual

Siemens

Siemens FDM273 manual

DSC PC 4010 Programming manual

DSC

DSC PC 4010 Programming manual

UniPOS 6202L quick start guide

UniPOS

UniPOS 6202L quick start guide

AJAX DoubleButton user manual

AJAX

AJAX DoubleButton user manual

Rondish Nexus User instructions

Rondish

Rondish Nexus User instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

NFS2-640/E OPERATING INSTRUCTIONS
This sheet must be framed and mounted adjacent to the control panel.
NFS2-640/E Operator’s Instructions — P/N 52744:A ECN 06-165 12/28/2006
Section 1 Operating Information
Normal Standby Operation.
1. Green POWER indicator lit steadily.
2. Red FIRE ALARM indicator off.
3. Yellow TROUBLE indicators off.
Alarm Condition.
1. Red FIRE ALARM indicator lit.
2. Alarm signaling devices activated.
3. Option module (remote station or supplementary alarm relay) acti-
vated.
4. Alarm information visible on LCD display.
Alarm Reset. After locating and correcting the alarm condition,
reset the control panel by pressing the SYSTEM RESET switch.
Trouble Conditions. Activation of trouble signal under normal
operation indicates a condition that requires immediate attention.
Contact your local service representative. Silence the audible signal
by pressing the ACKNOWLEDGE/SCROLL DISPLAY switch. The trouble
indicator will remain illuminated.
Section 2 Switch Functions
Acknowledge/Scroll Display. This silences the piezo
sounder and changes all flashing conditions to steady. Only one press
is necessary, regardless of the number of new alarms, troubles, or
supervisory signals. If the piezo is silenced, it sends an acknowledge
message to the printer and history file. Acknowledge also automati-
cally sends a special command to silence piezo sounders on the
FDU-80 and ACS-series annunciators.
Signal Silence. SIGNAL SILENCE performs all the functions of
ACKNOWLEDGE. In addition, if an alarm exists, it turns off all silence-
able circuits and illuminates the SIGNALS SILENCED indicator. It also
sends a SIGNALS SILENCED message to the LCD display, printer, and
history file. A subsequent alarm will then resound the system.
Notes:
1. This unit is programmed to inhibit signal silence for ____seconds.
2. This unit is programmed to automatically silence alarm signal after
_____ minutes.
Drill. The NFS2-640/E waits for the Drill switch to be pressed for
2 seconds (to prevent accidental activations), then turns on all silence-
able circuits (all FCM-1 modules/bell circuits that are programmed
silenceable), and turns off the Signals Silenced LED. It sends a Drill
Activated message to the LCD display, FDU-80, printer, and History
file.
System Reset. Resets the control panel in standalone applica-
tions. Resets panel when enabled in network applications.
Lamp Test. Press and hold the switch to lamp-test the LEDs.
Section 3 LED Indicators
Controls Active. Green LED which illuminates when the panel
assumes control of local operation as primary display; turns off when
another panel assumes control of local operation.
Power. Green LED which illuminates when primary power is
applied to the control panel.
Pre-Discharge. Red LED lights when any of the releasing zones
have been activated, but have not yet discharged a releasing agent;
turns off when no releasing zones are in the pre-discharge state.
Discharge. Red LED lights when any of the releasing zones are
active and in the process of discharging a releasing agent; turns off
when no releasing zones are discharging a releasing agent.
Abort Active. Yellow LED lights when an abort switch has been
activated; turns off when an abort switch has been pressed and its
timer is still counting down. Activation of a Manual Release Switch
will override Predischarge Delay and override an active Abort Release
Switch, resulting in an immediate agent release.
Fire Alarm. Red LED that flashes when one or more alarms occur.
Illuminates steadily after alarms are acknowledged; turns off when
SYSTEM RESET is pressed after alarm clears.
Pre-Alarm. Red LED that flashes when a pre-alarm threshold is
reached. The LCD display indicates if it is an ALERT or ACTION
pre-alarm.
Security. Blue LED that illuminates for a security alarm. LED
turns off after the alarm clears and SYSTEM RESET is pressed.
Supervisory. Yellow LED that flashes when a Supervisory, Haz-
ard Alert or Tamper condition occurs, such as a sprinkler valve tamper
condition. The LED turns off when the Supervisory condition clears.
The Hazard Alert or Tamper indication will latch until reset.
System Trouble. Yellow LED that flashes when one or more
troubles occur. Goes on steadily when ACKNOWLEDGE is pressed, and
turns off when all trouble conditions are cleared. Will illuminate if the
microprocessor watchdog timer fails (CPU FAIL).
Signals Silenced. Yellow LED that illuminates after SIGNALS
SILENCED has been pressed. Turns off when DRILL or SYSTEM RESET
is pressed.
Point Disabled. Yellow LED that illuminates when one or more
points are disabled. The LCD will indicate which points have been
disabled. Turns off when points are re-enabled.
Section 4 Audible Tone Indicator
Alarm. A continuous sounding tone.
Trouble/Security. A slow, pulsating tone signal having an equal
on and off time.
Supervisory. A fast, pulsating tone signal having an equal on and
off time.
Section 5 Periodic Testing and Maintenance
To ensure proper and reliable operation, system inspection and testing
should be scheduled monthly, or as required by NFPA 72 or local fire
codes. A qualified Service Representative should perform testing.
Before Testing: Notify fire department and/or central alarm
receiving station if alarm condition is transmitted. Notify facility per-
sonnel of the test so alarm sounding devices are ignored during the test
period.
After Testing: Notify all fire, central station, and/or building per-
sonnel when testing is complete.
Section 6 Audio/Telephone System Information
See DVC Operating Instructions!
Section 7 Local Service Representative:
NAME: ________________________________________________
ADDRESS: _____________________________________________
TELEPHONE NUMBER: ________________________________