Honeywell FCI 1400 User manual

1400
System Sensor
Ionization Smoke Detector
Features
• Unique dual unipolar sensor provides exceptional
stability.
• Built-in tamper-resistant feature.
• Built-in test switch.
• Built-in visual alarm indicator.
• Remote LED option.
• Compatible with FCI control panels.
• Field metering of detector sensitivity.
• Removable insect screen and cover for field
cleaning.
• Sealed against dirt, insects, and back pressure.
• Insect-resistant screening (.020"/.508mm
openings).
• Convenient terminal strip wiring.
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2006 Gamewell-FCI. All rights reserved. www.gamewell-fci.com 9020-0586 Rev. B page 1 of 2
Description
The System Sensor 1400 dual-chamber ionization smoke
detector is specifically designed to meet the performance
requirements of fire detection/alarm systems. This detec-
tor uses a state-of-the-art unipolar sensing chamber. The
detector is designed to provide open area detection and is
compatible with FCI fire alarm control panels. The detec-
tor operation and sensitivity can be tested in place.
The detector has an LED which flashes every ten seconds
indicating that power is being applied to the detector. The
LED lights steadily when the detector is in alarm. A re-
mote LED annunciator is available as an optional acces-
sory.
The 1400 detector includes a tamper-resistant feature
that, when used, prevents removal of the detector without
the use of a tool.
Sensitivity testing is performed by inserting a tool into the
recessed test switch opening.
Field metering of detector sensitivity may be performed
with the aid of a voltmeter and test kit MOD 400R.
Specifications
Nominal sensitivity 1.5%/ft. obscuration
Operating voltage 8.5 - 35 VDC (24 VDC nominal)
Standby current 100 µA maximum
Operating
temperature
32°to 120°F (0°to 49°C)
Operating humidity 10 % - 93 % relative humidity
Air velocity 1,200 ft. per minute maximum
Altitude 10,000 feet
Construction Off-white flame retardant plastic
Diameter 5.5 inches (14 cm)
Height 3.12 inches (8.0 cm)
Weight 0.7 lb (310 gm)
Note: Alarm current is limited by the control panel initiating
device circuit.
Part Number
1400
Ordering Information
Description
Ionization detector
1400
An ISO 9001-2000 Company
WARNING: To prevent detector contamination dur-
ing construction, smoke detectors must be protected
from dust and contamination until area is clean and
dust free. See NFPA 72-5-3.7.1.3.
Mounting
•On a 4-inch square box with plaster ring and FCI
supplied mounting bracket kit. Minimum depth 1.5
inches.
•On a 3.5 or 4-inch octagonal box.
Minimum depth 1.5 inches.
•Directly to ceiling using plastic screw anchors.
Refer to N.F.P.A. 72, Chapter 2-3. “Smoke Sensing Fire
Detectors” for spacing, location of detectors and other
guidelines.
Installation
Line up the arrows on the detector with the arrows on the
mounting bracket. Turn the detector clockwise until the
detector clicks into place.
To use the tamper-proof feature, break the smaller tab at
the scribed line in the tamper-proof tab located on the
detector mounting bracket. Install the detector. To remove
the detector from the bracket when using the tamper-proof
feature, insert the blade of a small screwdriver into the
hole on the side of the base and push the plastic lever
away from the detector head. Turn the detector counter-
clockwise for removal. NOTE: The decorative ring must
be removed in order to remove a head after it has been
made tamper-proof.
NOTE: The number of two-wire smoke detectors which
can be accommodated per zone varies with different con-
trol panels. Consult the control panel instruction manual to
determine the capacity.
Testing
Detectors may be tested in the following ways:
•A. Insert a tool into the test opening in the unit. For the
complete procedure, refer to the Installation and Main-
tenance Instructions furnished with each detector.
•B. Field metering of detector sensitivity may be per-
formed with the aid of a voltmeter and test kit MOD
400R. For the complete procedure, refer to the Installa-
tion and Maintenance Instructions furnished with each
detector.
Maintenance
Cleaning programs should be adapted to the individual
environment in conformance with NFPA Standard 72. We
recommend, at the least, an annual cleaning of the unit.
The detector screen and cover assembly can be removed,
revealing the sensing chamber. A vacuum cleaner can be
used to remove dust from the screen, cover and sensing
chamber. For the complete procedure, refer to the Instal-
lation and Maintenance instructions furnished with each
detector.
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
www.gamewell-fci.com 9020-0586 Rev. B page 2 of 2
Views Showing Position of Test Magnet

Other Honeywell Smoke Alarm manuals

Honeywell D355PL User manual

Honeywell

Honeywell D355PL User manual

Honeywell ADEMCO 5806 User manual

Honeywell

Honeywell ADEMCO 5806 User manual

Honeywell Ademco 5806 W3 Operating instructions

Honeywell

Honeywell Ademco 5806 W3 Operating instructions

Honeywell DFO800M User manual

Honeywell

Honeywell DFO800M User manual

Honeywell FCI 2151 User manual

Honeywell

Honeywell FCI 2151 User manual

Honeywell NOTIFIER FSP-951-SELFT User manual

Honeywell

Honeywell NOTIFIER FSP-951-SELFT User manual

Honeywell DFS8MS User manual

Honeywell

Honeywell DFS8MS User manual

Honeywell 5800COMBO User manual

Honeywell

Honeywell 5800COMBO User manual

Honeywell X Series User manual

Honeywell

Honeywell X Series User manual

Honeywell GasAlertMicro 5 User manual

Honeywell

Honeywell GasAlertMicro 5 User manual

Honeywell Gamewell 7100 Series Installation instructions

Honeywell

Honeywell Gamewell 7100 Series Installation instructions

Honeywell SK-Beam User manual

Honeywell

Honeywell SK-Beam User manual

Honeywell FMST FXV(E) Series User manual

Honeywell

Honeywell FMST FXV(E) Series User manual

Honeywell Fire-Lite Alarms D350RPL User manual

Honeywell

Honeywell Fire-Lite Alarms D350RPL User manual

Honeywell FS10-R User manual

Honeywell

Honeywell FS10-R User manual

Honeywell DFS8MS User manual

Honeywell

Honeywell DFS8MS User manual

Honeywell Velociti 3 Series User manual

Honeywell

Honeywell Velociti 3 Series User manual

Honeywell Fire-Lite Alarms SD365R User manual

Honeywell

Honeywell Fire-Lite Alarms SD365R User manual

Honeywell SS4-AS User manual

Honeywell

Honeywell SS4-AS User manual

Honeywell SS4-A HART User manual

Honeywell

Honeywell SS4-A HART User manual

Honeywell SiXSMOKE User manual

Honeywell

Honeywell SiXSMOKE User manual

Honeywell DF8M User manual

Honeywell

Honeywell DF8M User manual

Honeywell DFS8MS User manual

Honeywell

Honeywell DFS8MS User manual

Honeywell Fire-Lite Alarms OSI-RI-FL User manual

Honeywell

Honeywell Fire-Lite Alarms OSI-RI-FL User manual

Popular Smoke Alarm manuals by other brands

Abus RWM50 user manual

Abus

Abus RWM50 user manual

Online Power Fire Alarm Back-up UPS1481 UNIT user manual

Online Power

Online Power Fire Alarm Back-up UPS1481 UNIT user manual

Detectortesters Solo 365 user manual

Detectortesters

Detectortesters Solo 365 user manual

Steren ALA-HUM instruction manual

Steren

Steren ALA-HUM instruction manual

System Sensor 2112/24R Installation and maintenance instructions

System Sensor

System Sensor 2112/24R Installation and maintenance instructions

Elko iNELS Air AirSD-100S quick start guide

Elko

Elko iNELS Air AirSD-100S quick start guide

Ei Electronics Ei405TY RF Optical Technical specifications

Ei Electronics

Ei Electronics Ei405TY RF Optical Technical specifications

SCS Sentinel DAAF-10Y-CE Installation and use instruction

SCS Sentinel

SCS Sentinel DAAF-10Y-CE Installation and use instruction

Micropack FDS300 Safety manual

Micropack

Micropack FDS300 Safety manual

AngelEye SA700-AE-UK user manual

AngelEye

AngelEye SA700-AE-UK user manual

Bentel FireClass FC400PH manual

Bentel

Bentel FireClass FC400PH manual

AirSense ModuLaser installation manual

AirSense

AirSense ModuLaser installation manual

Ningbo Siterwell Electronics GS536 user manual

Ningbo Siterwell Electronics

Ningbo Siterwell Electronics GS536 user manual

B.E.G. SD2-RF Installation and operating instructions

B.E.G.

B.E.G. SD2-RF Installation and operating instructions

Universal 976LR instructions

Universal

Universal 976LR instructions

Universal SS-2895 manual

Universal

Universal SS-2895 manual

Satel MSD-300 user manual

Satel

Satel MSD-300 user manual

Doro Secure 291 quick guide

Doro

Doro Secure 291 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.