manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Smoke Alarm
  8. •
  9. Honeywell FCI 1400 User manual

Honeywell FCI 1400 User manual

Other Honeywell Smoke Alarm manuals

Honeywell Fire-Lite Alarms BEAM355A User manual

Honeywell

Honeywell Fire-Lite Alarms BEAM355A User manual

Honeywell SiXCOMBO User manual

Honeywell

Honeywell SiXCOMBO User manual

Honeywell MS-5UD Series User manual

Honeywell

Honeywell MS-5UD Series User manual

Honeywell Ademco 5806 W3 Operating instructions

Honeywell

Honeywell Ademco 5806 W3 Operating instructions

Honeywell XLS-278 User manual

Honeywell

Honeywell XLS-278 User manual

Honeywell SiXSMOKE User manual

Honeywell

Honeywell SiXSMOKE User manual

Honeywell TC842B1007 User manual

Honeywell

Honeywell TC842B1007 User manual

Honeywell GasAlert Extreme User manual

Honeywell

Honeywell GasAlert Extreme User manual

Honeywell NOTIFIER FSP-951-SELFT User manual

Honeywell

Honeywell NOTIFIER FSP-951-SELFT User manual

Honeywell V-PLEX 5192SD User manual

Honeywell

Honeywell V-PLEX 5192SD User manual

Honeywell JTYJ-GD-01BW User manual

Honeywell

Honeywell JTYJ-GD-01BW User manual

Honeywell C8600A User manual

Honeywell

Honeywell C8600A User manual

Honeywell 5800COMBO-CN User manual

Honeywell

Honeywell 5800COMBO-CN User manual

Honeywell Silent Knight SK-Duct User manual

Honeywell

Honeywell Silent Knight SK-Duct User manual

Honeywell DFS8MS User manual

Honeywell

Honeywell DFS8MS User manual

Honeywell Silent Knight SD505 User manual

Honeywell

Honeywell Silent Knight SD505 User manual

Honeywell FS10-R User manual

Honeywell

Honeywell FS10-R User manual

Honeywell SK-Beam User manual

Honeywell

Honeywell SK-Beam User manual

Honeywell X Series User manual

Honeywell

Honeywell X Series User manual

Honeywell FCI 1151 User manual

Honeywell

Honeywell FCI 1151 User manual

Honeywell Smoke Alarm User manual

Honeywell

Honeywell Smoke Alarm User manual

Honeywell Notifier NBG-12LX User manual

Honeywell

Honeywell Notifier NBG-12LX User manual

Honeywell SS4-AS User manual

Honeywell

Honeywell SS4-AS User manual

Honeywell TC842B1007AE User manual

Honeywell

Honeywell TC842B1007AE User manual

Popular Smoke Alarm manuals by other brands

Dyna-Glo DGY784BDP installation instructions

Dyna-Glo

Dyna-Glo DGY784BDP installation instructions

NOXE LUMENS Installation and user guide

NOXE

NOXE LUMENS Installation and user guide

Develco SMAZB-141 installation manual

Develco

Develco SMAZB-141 installation manual

Kidde PI2010CA user guide

Kidde

Kidde PI2010CA user guide

Gentex 7109CS installation instructions

Gentex

Gentex 7109CS installation instructions

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

teko Astra-42A user guide

teko

teko Astra-42A user guide

ELRO FS8110 instruction manual

ELRO

ELRO FS8110 instruction manual

Heiman SMOKI NS-626PHS user manual

Heiman

Heiman SMOKI NS-626PHS user manual

Siemens PE-11C installation instructions

Siemens

Siemens PE-11C installation instructions

Resolution Products RE612 CryptiX quick start guide

Resolution Products

Resolution Products RE612 CryptiX quick start guide

First Alert PC900V user manual

First Alert

First Alert PC900V user manual

Eminent EM6590 E-Domotica user manual

Eminent

Eminent EM6590 E-Domotica user manual

Ei Electronics Ei Ei168RC user manual

Ei Electronics

Ei Electronics Ei Ei168RC user manual

Carrier Kidde Quell Q301 user manual

Carrier

Carrier Kidde Quell Q301 user manual

Family Gard FG225 user manual

Family Gard

Family Gard FG225 user manual

Regin SDD-S65 instruction manual

Regin

Regin SDD-S65 instruction manual

LST ÜMS-55000-841 Specification sheet

LST

LST ÜMS-55000-841 Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1400
System Sensor
Ionization Smoke Detector
Features
• Unique dual unipolar sensor provides exceptional
stability.
• Built-in tamper-resistant feature.
• Built-in test switch.
• Built-in visual alarm indicator.
• Remote LED option.
• Compatible with FCI control panels.
• Field metering of detector sensitivity.
• Removable insect screen and cover for field
cleaning.
• Sealed against dirt, insects, and back pressure.
• Insect-resistant screening (.020"/.508mm
openings).
• Convenient terminal strip wiring.
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2006 Gamewell-FCI. All rights reserved. www.gamewell-fci.com 9020-0586 Rev. B page 1 of 2
Description
The System Sensor 1400 dual-chamber ionization smoke
detector is specifically designed to meet the performance
requirements of fire detection/alarm systems. This detec-
tor uses a state-of-the-art unipolar sensing chamber. The
detector is designed to provide open area detection and is
compatible with FCI fire alarm control panels. The detec-
tor operation and sensitivity can be tested in place.
The detector has an LED which flashes every ten seconds
indicating that power is being applied to the detector. The
LED lights steadily when the detector is in alarm. A re-
mote LED annunciator is available as an optional acces-
sory.
The 1400 detector includes a tamper-resistant feature
that, when used, prevents removal of the detector without
the use of a tool.
Sensitivity testing is performed by inserting a tool into the
recessed test switch opening.
Field metering of detector sensitivity may be performed
with the aid of a voltmeter and test kit MOD 400R.
Specifications
Nominal sensitivity 1.5%/ft. obscuration
Operating voltage 8.5 - 35 VDC (24 VDC nominal)
Standby current 100 µA maximum
Operating
temperature
32°to 120°F (0°to 49°C)
Operating humidity 10 % - 93 % relative humidity
Air velocity 1,200 ft. per minute maximum
Altitude 10,000 feet
Construction Off-white flame retardant plastic
Diameter 5.5 inches (14 cm)
Height 3.12 inches (8.0 cm)
Weight 0.7 lb (310 gm)
Note: Alarm current is limited by the control panel initiating
device circuit.
Part Number
1400
Ordering Information
Description
Ionization detector
1400
An ISO 9001-2000 Company
WARNING: To prevent detector contamination dur-
ing construction, smoke detectors must be protected
from dust and contamination until area is clean and
dust free. See NFPA 72-5-3.7.1.3.
Mounting
•On a 4-inch square box with plaster ring and FCI
supplied mounting bracket kit. Minimum depth 1.5
inches.
•On a 3.5 or 4-inch octagonal box.
Minimum depth 1.5 inches.
•Directly to ceiling using plastic screw anchors.
Refer to N.F.P.A. 72, Chapter 2-3. “Smoke Sensing Fire
Detectors” for spacing, location of detectors and other
guidelines.
Installation
Line up the arrows on the detector with the arrows on the
mounting bracket. Turn the detector clockwise until the
detector clicks into place.
To use the tamper-proof feature, break the smaller tab at
the scribed line in the tamper-proof tab located on the
detector mounting bracket. Install the detector. To remove
the detector from the bracket when using the tamper-proof
feature, insert the blade of a small screwdriver into the
hole on the side of the base and push the plastic lever
away from the detector head. Turn the detector counter-
clockwise for removal. NOTE: The decorative ring must
be removed in order to remove a head after it has been
made tamper-proof.
NOTE: The number of two-wire smoke detectors which
can be accommodated per zone varies with different con-
trol panels. Consult the control panel instruction manual to
determine the capacity.
Testing
Detectors may be tested in the following ways:
•A. Insert a tool into the test opening in the unit. For the
complete procedure, refer to the Installation and Main-
tenance Instructions furnished with each detector.
•B. Field metering of detector sensitivity may be per-
formed with the aid of a voltmeter and test kit MOD
400R. For the complete procedure, refer to the Installa-
tion and Maintenance Instructions furnished with each
detector.
Maintenance
Cleaning programs should be adapted to the individual
environment in conformance with NFPA Standard 72. We
recommend, at the least, an annual cleaning of the unit.
The detector screen and cover assembly can be removed,
revealing the sensing chamber. A vacuum cleaner can be
used to remove dust from the screen, cover and sensing
chamber. For the complete procedure, refer to the Instal-
lation and Maintenance instructions furnished with each
detector.
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472 - Tel: (203) 484-7161 - Fax: (203) 484-7118
www.gamewell-fci.com 9020-0586 Rev. B page 2 of 2
Views Showing Position of Test Magnet