K0315 12/02 Rev. D
ADEMCO 269R/270R
Holdup Switch
INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
The ADEMCO 269R/270R Holdup Switch (Figure 1) is a finger-
operated switch for activating the holdup signal at the control
and/or any other security application. The 269R adds a protective
steel cover. The Holdup Switch is typically mounted under a
counter for inconspicuous operation. The device comes standard as
a latching type switch that is easily converted to a non-latching
type.
If the switch is used as a latching type switch, the supplied reset
key is used to reset the device. Additional reset keys may be
obtained separately by ordering ADEMCO part number K4563.
PROGRAMMING
For Honeywell controls, program the unit like any other zone,
according to the control’s installation and setup guide. Enter the
following information when prompted for in zone programming:
“ZONE TYPE” = “06”
“INPUT TYPE” = “01”
For other manufacture controls, refer to the controls instructions
for specific programming instructions.
MOUNTING
Refer to the steps and figures that follow for typical mounting
installation. If required, convert the latching device to a non-
latching device as shown in figure 2.
1. Run the wiring from the control panel to the device, through
the opening in the case back as shown in Figure 3.
2. Wire the device for a normally closed or a normally open loop
with no EOL resistor or for a normally-closed or a normally
open loop with an EOL resistor as shown in figure 3, detail A
and B, respectively. Where Form C wiring is required,
providing full supervision of the loop refer to figure 3, detail C.
3. Secure the cover to the case with two screws (No. 6 x 7/8) as
shown in figure 1. Note the cover screws are noticeably
shorter than the mounting screws. Be sure to use the correct
holes. The holes opposite these are used to secure the device to
the counter.
IMPORTANT: To prevent damage to the case do not
over tighten the cover screws.
4. Peel the backing from the double stick tape strips on the back
of the device and position the device in its mounting location.
IMPORTANT: The double stick tape is provided to
temporarily hold the assembly in place while drilling
the pilot holes. The device must be permanently
mounted with the screws supplied.
5. Using the case as a drill template, drill a 1/16” diameter pilot
hole at the two case mounting holes (Figure 1).
6. Secure the assembled case with the protective cover (if
required) to the counter with two screws (No. 6 x 1-3/4)
supplied. (Figure 4).
+
+
MOUNTING
HOLE
TRIGGER
RESET KEY
(K4563 SUPPLIED)
MOUNTING
HOLE
COVER
SCREW (2)
No. 6x7/8
PROTECTIVE
STEEL
COVER
(269R ONLY)
CIRCUIT
BOARD
COVER
ATTACH HOLE
COVER
AT TA C H
HOLE
MOUNTING
SCREW (2)
No. 6X1 3/4
COVER
SCREW
COVER
269R-001-V1
Figure 1
TRIGGER
ASSEMBLY
TO CONVERT TO MOMENTARY (NO LATCHING) SWITCH
OPERATION, REMOVE THE TRIGGER ASSEMBLY FROM THE
CASE. USING A PAIR OF CUTTERS, CUT THE TRIGGER LATCH
AT THE POINT THE "ARROW" IS STAMPED ON THE CASE.
TRIGGER
LATCH
ARROW
(CUT POINT)
269R-004-V0
Figure 2
NO EOL
NC
C
NO EOL
NC
C
269R-007-V1
WIRE AS SHOWN FOR
A NORMALLY-CLOSED
LOOP WITH NO EOL
RESISTOR.
WIRE AS SHOWN FOR
A NORMALLY-OPEN
LOOP WITH NO EOL
RESISTOR.
DETAIL A
NO EOL
NC
C
NO EOL
NC
C
269R-008-V1
WIRE AS SHOWN FOR
A NORMALLY-CLOSED
LOOP WITH AN EOL
RESISTOR.
WIRE AS SHOWN FOR
A NORMALLY-OPEN
LOOP WITH AN EOL RESISTOR.
NOTE THAT THE EOL
TERMINAL IS NOT USED
IN A NORMALLY OPEN LOOP.
DETAIL B
Figure 3
NO EOL
NC
C
NO EOL
NC
C
269R-012-V1
CONTROL PANEL
ZONE TERMINALS
FORM "C"
WIRING PROVIDES
FULL SUPERVISION
OF THE LOOP
DETAIL C
MOUNTING
SCREW (2)
No. 6X1 3/4
(SUPPLIED)
269R-010-V0
MOUNTING
HOLE
PROTECTIVE
STEEL COVER
(269R ONLY)
MOUNTING
HOLE
IMPORTANT:
THIS DEVICE MUST
BE PERMANENTLY
MOUNTED WITH THE
SCREWS SUPPLIED
HOLDUP SWITCH SHOWN MOUNTED
IN TYPICAL UNDER COUNTER APPLICATION
Figure 4
SPECIFICATIONS
Physical: 2"W x 3-1/2"H x 1-1/4"D
(51mm x 89mm x 32mm)
Electrical:
Contact
Rating:
0.2 A @ 30 VDC (MAX)
WARNING: Observe contact rating limitations.
Do not use to switch Line Voltage AC current.
Operating
Temperature:
14°F to 140°F
-10°C to 60°C
Agency: UL 636 – Holdup alarm units and systems
Reset Key: Supplied, Part Number K4563 to order separately
CUS
LISTED
R
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are
vital to continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing and offering a regular maintenance program
to the user, as well as acquainting the user with the proper operation and limitations of the alarm system
and its component parts. Recommendations must be included for a specific program of frequent testing (at
least weekly) to insure the system's operation at all times.
WARRANTY INFORMATION
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa
ÊK0315ÈŠ
K0315 12/02 Rev. D
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2010 Honeywell International Inc.
www.honeywell.com/security

This manual suits for next models

1

Other Honeywell Switch manuals

Honeywell 5869 User manual

Honeywell

Honeywell 5869 User manual

Honeywell RPLS730B User manual

Honeywell

Honeywell RPLS730B User manual

Honeywell C6045D User manual

Honeywell

Honeywell C6045D User manual

Honeywell PLS730B User manual

Honeywell

Honeywell PLS730B User manual

Honeywell 39342 User manual

Honeywell

Honeywell 39342 User manual

Honeywell Dolphin 7800 Operation manual

Honeywell

Honeywell Dolphin 7800 Operation manual

Honeywell ZW4003 User manual

Honeywell

Honeywell ZW4003 User manual

Honeywell RTS-CSA User manual

Honeywell

Honeywell RTS-CSA User manual

Honeywell ZW4103 User manual

Honeywell

Honeywell ZW4103 User manual

Honeywell GLS Series User manual

Honeywell

Honeywell GLS Series User manual

Honeywell ZW4003 User manual

Honeywell

Honeywell ZW4003 User manual

Honeywell miniMAX User manual

Honeywell

Honeywell miniMAX User manual

Honeywell Switches User manual

Honeywell

Honeywell Switches User manual

Honeywell PK 88231 User manual

Honeywell

Honeywell PK 88231 User manual

Honeywell 39348 User manual

Honeywell

Honeywell 39348 User manual

Honeywell VC Series User manual

Honeywell

Honeywell VC Series User manual

Honeywell 39346 User manual

Honeywell

Honeywell 39346 User manual

Honeywell Ademco VistaView-100 Assembly instructions

Honeywell

Honeywell Ademco VistaView-100 Assembly instructions

Honeywell 39351 User manual

Honeywell

Honeywell 39351 User manual

Honeywell NR Series Configuration guide

Honeywell

Honeywell NR Series Configuration guide

Honeywell RXSW100A3CULH User manual

Honeywell

Honeywell RXSW100A3CULH User manual

Honeywell MDDS8202 User manual

Honeywell

Honeywell MDDS8202 User manual

Honeywell C6097A User manual

Honeywell

Honeywell C6097A User manual

Honeywell 10260A Series User manual

Honeywell

Honeywell 10260A Series User manual

Popular Switch manuals by other brands

Crestron HD-MD6X2-4K-E Supplemental guide

Crestron

Crestron HD-MD6X2-4K-E Supplemental guide

WIKA FSD-3 operating instructions

WIKA

WIKA FSD-3 operating instructions

Vivint Smart Hub Lite Getting Started User Guide

Vivint

Vivint Smart Hub Lite Getting Started User Guide

Mellanox Technologies switchx MSX1035B-1BRR installation guide

Mellanox Technologies

Mellanox Technologies switchx MSX1035B-1BRR installation guide

Altinex MT104-100/103 user guide

Altinex

Altinex MT104-100/103 user guide

TRENDnet TE100-S1616V Specifications

TRENDnet

TRENDnet TE100-S1616V Specifications

Anybus AWB5011 user manual

Anybus

Anybus AWB5011 user manual

Chauvet Pro-D6 user manual

Chauvet

Chauvet Pro-D6 user manual

schmersal RSS 36-I2-D-R-ST manual

schmersal

schmersal RSS 36-I2-D-R-ST manual

Atlas WPD-SWCC owner's manual

Atlas

Atlas WPD-SWCC owner's manual

Nice Moon MOTB Instructions and warnings for installation and use

Nice

Nice Moon MOTB Instructions and warnings for installation and use

schmersal AZM201B-SK-T-1P2PW-A Instructions for operation

schmersal

schmersal AZM201B-SK-T-1P2PW-A Instructions for operation

Allied Telesis AT-9924SP brochure

Allied Telesis

Allied Telesis AT-9924SP brochure

Allnet ALL-SG8926PM user manual

Allnet

Allnet ALL-SG8926PM user manual

Safe Signal OSY2 Installation and maintenance instructions

Safe Signal

Safe Signal OSY2 Installation and maintenance instructions

Lantech LGS-1104 user manual

Lantech

Lantech LGS-1104 user manual

Ross Synergy 1 SD manual

Ross

Ross Synergy 1 SD manual

Kramer VP-770 user manual

Kramer

Kramer VP-770 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.