manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Honeywell
  6. •
  7. Transmitter
  8. •
  9. Honeywell ADEMCO 5805-6 Assembly instructions

Honeywell ADEMCO 5805-6 Assembly instructions

Other Honeywell Transmitter manuals

Honeywell oneWireless XYR 6000 User manual

Honeywell

Honeywell oneWireless XYR 6000 User manual

Honeywell XNX User manual

Honeywell

Honeywell XNX User manual

Honeywell ST 3000 User manual

Honeywell

Honeywell ST 3000 User manual

Honeywell 5834-2 Assembly instructions

Honeywell

Honeywell 5834-2 Assembly instructions

Honeywell XNX Universal Transmitter User manual

Honeywell

Honeywell XNX Universal Transmitter User manual

Honeywell 5816 Assembly instructions

Honeywell

Honeywell 5816 Assembly instructions

Honeywell SMV800 Instruction Manual

Honeywell

Honeywell SMV800 Instruction Manual

Honeywell ADEMCO 5817 Assembly instructions

Honeywell

Honeywell ADEMCO 5817 Assembly instructions

Honeywell STT700 SmartLine User guide

Honeywell

Honeywell STT700 SmartLine User guide

Honeywell ADEMCO 5804 Assembly instructions

Honeywell

Honeywell ADEMCO 5804 Assembly instructions

Honeywell STT850 SMARTLINE User manual

Honeywell

Honeywell STT850 SMARTLINE User manual

Honeywell SmartLine ST700 User manual

Honeywell

Honeywell SmartLine ST700 User manual

Honeywell MCE 2 User manual

Honeywell

Honeywell MCE 2 User manual

Honeywell 5815-1 User manual

Honeywell

Honeywell 5815-1 User manual

Honeywell ADEMCO 5805-6 User manual

Honeywell

Honeywell ADEMCO 5805-6 User manual

Honeywell ST 3000 User manual

Honeywell

Honeywell ST 3000 User manual

Honeywell 5878 - Wireless Wall Transmitter User manual

Honeywell

Honeywell 5878 - Wireless Wall Transmitter User manual

Honeywell XNX-AM Series User manual

Honeywell

Honeywell XNX-AM Series User manual

Honeywell oneWireless XYR 6000 User manual

Honeywell

Honeywell oneWireless XYR 6000 User manual

Honeywell SmartLine ST700 User manual

Honeywell

Honeywell SmartLine ST700 User manual

Honeywell XNX User manual

Honeywell

Honeywell XNX User manual

Honeywell ADEMCO 5804-2 User manual

Honeywell

Honeywell ADEMCO 5804-2 User manual

Honeywell SmartLine User manual

Honeywell

Honeywell SmartLine User manual

Honeywell OELD User manual

Honeywell

Honeywell OELD User manual

Popular Transmitter manuals by other brands

Seneca K120RTD installation manual

Seneca

Seneca K120RTD installation manual

Nautel GV40 installation manual

Nautel

Nautel GV40 installation manual

HumanTechnik cm-light operating instructions

HumanTechnik

HumanTechnik cm-light operating instructions

INOR APAQ C130 TC User instructions

INOR

INOR APAQ C130 TC User instructions

Linear DXS-64 operating instructions

Linear

Linear DXS-64 operating instructions

FeinTech ABT00102 instruction manual

FeinTech

FeinTech ABT00102 instruction manual

Geo Web Pack quick start guide

Geo

Geo Web Pack quick start guide

Inovonics EchoStream EN1210W installation instructions

Inovonics

Inovonics EchoStream EN1210W installation instructions

IKONNIK KA-6 quick start guide

IKONNIK

IKONNIK KA-6 quick start guide

Rohde & Schwarz SR8000 Series System manual

Rohde & Schwarz

Rohde & Schwarz SR8000 Series System manual

Audio Technica UniPak ATW-T93 Installation and operation

Audio Technica

Audio Technica UniPak ATW-T93 Installation and operation

NIVELCO EasyTREK SCA-300 Series Programming manual

NIVELCO

NIVELCO EasyTREK SCA-300 Series Programming manual

Kamstrup READy MTU Installation and operation guide

Kamstrup

Kamstrup READy MTU Installation and operation guide

Omega ZW Series user guide

Omega

Omega ZW Series user guide

ABB Field 264H Instructions for installation

ABB

ABB Field 264H Instructions for installation

Dejero EnGo 3x manual

Dejero

Dejero EnGo 3x manual

Rosemount 4600 Reference manual

Rosemount

Rosemount 4600 Reference manual

RKI Instruments M2A 65-2643RK-05-04 Operator's manual

RKI Instruments

RKI Instruments M2A 65-2643RK-05-04 Operator's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

-ADEMCO 5805-6
Wireless Key Transmitter
INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
The 5805-6 is a compact, six-button, eight-loop portable
wireless transmitter. It is intended for use only with
wireless alarm systems that support 5800 series
receivers. Individual buttons on the transmitter may
be programmed for any zone response, but are typically
used for arming and disarming.
This device supports both Standard and High-Security
(encrypted) modes. The latter sends rolling-code
encrypted messaging to the RF receiver.
This device must be used with a receiver or control
that supports high security mode i.e.: 5881EN,
5883, 6150RF, or 6160RF receiver or a LYNXR
Series control panel (Revision 13.1 or higher if you
intend to use it in high security mode).
The 5805-6 is powered by one replaceable lithium
battery designed to provide up to four years of life. For
battery installation, see Replacing the Battery.
Figure 1 - 5805-6 Button Designations
PROGRAMMING
The 5805-6 is assigned two unique serial numbers
during manufacture and each button, or button
combination on the unit also has a distinct "loop"
number (refer to Figure 1) that must be programmed
into the control panel during installation. Assign each
button, or button combination, to one of eight
individual zones and designate the Input Type as "BR"
(Button Type RF).
If you are enrolling the 5805-6 locally with an
RF Keypad, refer to the keypad’s Installation
Instructions for programming instructions.
1. When prompted, enter the serial number either by:
Pressing and releasing the button (or buttons) that
you are programming twice (wait about 5 seconds
between button activations).
or Manually through the keypad.
Notes: (1) To activate the transmitter, the 5805-6 buttons must
be pressed and held for at least one-half second.
(2) Serial #2 is one (1) digit higher than serial #1,
which is printed on the rear of the transmitter
Loop 4 Setup
Both of the Loop 4 buttons must be enrolled in the
control, even if they will not be used. If one or both of
the loops is not being used, program it as Zone Type 23
(No Alarm Response). Otherwise assign it to the
desired zone type.
2. Exit Programming Mode after programming is
complete.
For complete details on how to program the
transmitter's serial number at the control panel, see
the control unit's installation instructions.
Assigning a Wireless Key to a User
On most control panels, if the wireless key is assigned
to arm and disarm the system, you must assign it to a
user in order for it to operate. This is accomplished
through User Code programming at the control panel.
See the control panel’s Installation and Setup Guide
for specific instructions on programming User Codes.
If you are programming arming and disarming
functions on both serial numbers, each serial number
must be assigned to a separate user.
SELECTING STANDARD OR HIGH-SECURITY MODE
For use with LYNXR Series controls earlier than
Revision 13.1, the Standard Mode must be
selected.
To select Standard Mode, simultaneously press and
hold the OFF, 1 and 2 buttons for three seconds.
To select High-Security Mode, simultaneously press
and hold the ON, 1 and 2 buttons for three seconds.
The LED flashes green when transmitting in Standard
Mode and red when transmitting in High-Security
Mode.
ACTIVATING HIGH-SECURITY MODE
To ensure proper functionality, the 5805-6 must
be synced to the security system.
1. After selecting High-Security mode, put the system
in Go/No Go Test mode.
2. To sync the transmitter with the receiver,
simultaneously press and hold the ON, OFF, 1 and 2
buttons until the panel beeps (see Figure 1). For
LYNXR Series controls proceed to step 4.
Note: The LYNXR Series panels confirm the synchronization
by sounding two beeps.
3. To sync the device in High Security Mode, press
either the ON, OFF, 1, or 2 button ONCE, until the
panel beeps indicating receipt.
4. To sync the second serial number of the wireless key
with the receiver, simultaneously press and hold the
1, 2, 3, and 4 buttons until the panel beeps. For
LYNXR Series controls proceed to step 6.
5. To sync the device in High Security Mode, press the
3 or 4 button ONCE, and hold until the panel beeps
indicating receipt.
Note: If no beep is heard, exit Go/No Go mode, and repeat
Steps 1 - 5.
6. Exit Go/No Go mode by entering user code + 1 (OFF).
USING TWO RECEIVERS IN HIGH-SECURITY MODE
If the control supports two receivers and you plan to
use them in the high-security mode perform the
following:
1. Enroll the transmitters into the receivers one at a
time, by disconnecting Receiver #2, and enrolling
as described in “Activating High Security Mode”.
2. Disconnect Receiver #1, reconnect Receiver #2,
and repeat the enrollment procedure. This
process ensures proper High Security operation
with both receivers.
Temporarily disable the receivers’ supervisory
zones while enrolling, to prevent them from going
into “trouble” when disconnected. After enrolling,
re-enable the supervisory zones.
REPLACING THE BATTERY
The LED will not flash during transmission if the
battery is low. Replace the battery as follows.
1. Remove the case back by using the blade of a small
screwdriver to pry it open.
2. Insert the blade of a small screwdriver as shown in
Figure 2.
3. Twist the screwdriver to release the battery.
4. Carefully remove the battery.
5805-010-V0
BATTERY
(+)
INSERT
SCREWDRIVER
BLADE HERE
Figure 2 – Removing the Battery
5. Press and hold any button for at least two seconds.
6. Insert a new battery in the case back location as
shown in Figure 3. Positive (+) end must face
up. Use Maxell CR2032, Duracell DL 20325, or
Varta CR2032 lithium battery only.
!
Improper installation will result in damage
to the battery.
7. Close the case by snapping the case (front and
back) together.
8. Press any button and verify that the LED flashes.
!
Do not remove the printed circuit board.
NOTE
POSITIVE (+) SIDE
MUST FACE UP
5805-008-V2
INSERT THIS
END FIRST
BATTERY
(+)
INSTALL UNDER THIS TAB
AND ATOP THIS TAB
Figure 3 – Installing the Battery
SPECIFICATIONS
Unit Dimensions: 2.2 in (55mm) x 1.5 in (37mm) x .5 in (12.7mm)
Battery: Panasonic CR2032, Maxell CR2032, Duracell DL 20325, or Varta CR2032 only
FOR WARRANTY INFORMATION AND FOR DETAILS REGARDING THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM, REFER TO THE
INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL WITH WHICH THIS DEVICE IS USED.
FCC AND INDUSTRY CANADA STATEMENT
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES AND RSS210 OF INDUSTRY CANADA. OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT
ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. THE USER SHALL NOT
MAKE ANY CHANGES OR MODIFICATIONS TO THE EQUIPMENT UNLESS AUTHORIZED BY THE INSTALLATION AND SETUP GUIDE.
‡K5760V2SŠ
K5760V2 7/06 Rev. A
165 Eileen Way, Syosset, New York 11791
Copyright © 2006 Honeywell International Inc.
www.honeywell.com/security