Pre-Charged Tubing Kits
3/8” & 5/8” efrigeration Lines
(Sold Separately)
20’ 404-20610
35’ 404-35610
55’ 404-55610
Hoshizaki
O P E R AT I N G L I M I T S
• Ambient Temp ange 45 - 100˚F
• Water Temp ange 45 - 90˚F
• Water Pressure 10 - 113psig
• Voltage ange 187 - 253V
ELECTRICAL&PLUMBING/KM-2000/2400S H3
• 208 - 230V/60/3
• 20 amp Max Fuse (30 amp Max Fuse - KM-2400)
• 1/2” FPT copper or equivalent independent potable water supply
• 3/4” FPT independent drain connection
SERVICE
• Panels easily removed and all components
accessible for service.
• emovable/cleanable air filters
(Air-cooled model only)
D
DI
IM
ME
EN
NS
SI
IO
ON
NS
S
W x D x H
KM-2000S H3
48 x 273/8 x 367/16
KM-2400SRH3
48 x 273/8 x 367/16
STACKAB L E ICE C U BER
©HOSHIZAKI AMERICA, INC.
618 Hwy. 74 S., Peachtree City, GA 30269 TEL 1-800-438-6087 FAX 1-800-345-1325 www.hoshizaki.com Printed in .S.A.
KM-2000/2400S_H3
3 PHASE STACKABLE ICE CUBER
FRONT VIEW - KM-2000/2400 SIDE VIEW - KM-2000/2400
KM-2400SRH3 REMOTE AIR-COOLED NIT
UTILITY CONSUMPTION
Model Number
70˚
50˚ 70˚
1891
90˚
80˚
90˚
Ice Production
Per Cycle
KWH per
100 LBS.
Potable
Water
Gal. per
100 lbs.
Lbs. Cubes
KM-2000SWH3
Air Temp˚ F.
Water Temp˚ F.
SPECIFICATIONS
Model Number Condenser Amperage Min. Circuit
Ampacity Shipping
Weight
9.5 20 400 lbs.
Water-Cooled
KM-2000SWH3
3.8 20.7
1885
1883
1883
1873
1817
1776
1740
KM-2000SRH3 Remote
Air-Cooled 12.0 20 400 lbs.
46.3 2160
1864
Condenser
Water
Gal. per
100 lbs.
77
KM-2000 REMOTE AIR - COOLED 3 PHASE
70˚
50˚ 70˚
1865
90˚
80˚
90˚
Air Temp˚ F.
Water Temp˚ F.
1839
1831
1831
1786
1746
1679
1649
1748
KM- 2 000 WAT E R - C O OL ED 3 PH A SE
STO RAG E BI NS
Model Number Application Capacity ARI-Rated Capacity
B-800 800 lbs. 600 lbs.
B-900 900 lbs. 660 lbs.
B-1150 1150 lbs. N/A
B-1300 1275 lbs. N/A
B-1500 1490 lbs. N/A
KM-2000SRH3 4.4 20.0
46.3 2160 N/A
KM-2400SRH3 5.1 21.9
44 2160 N/A
KM-2400SRH3 17 30
Remote
Air-Cooled 425 lbs.
• Water-cooled 3 phase / emote Air-cooled 3 phase
• emote Air-cooled 3 phase
B-1650 1605 lbs. N/A
KM-2400 REMOTE AIR - COOLED 3 PHASE
70˚
50˚ 70˚
2301
90˚
80˚
90˚
Air Temp˚ F.
Water Temp˚ F.
2305
2307
2307
2315
2172
2100
1980
2321
ICE DROP ZONE - KM-2000/2400
KM-2000SRH3 REMOTE AIR-COOLED NIT
KM-2000SWH3 WATER-COOLED NIT
36
155/8
URC-24F
Air Flow
121/2
19 3/4
43 3/4
93/4
3/8” Liquid
Refrigerant
Line
5/8” Discharge Line
Electrical Conduit
Access
URC-24F Remote Condenser (Sold Separately)
For Use with KM-2400S H3
Voltage supply for the URC Remote Condenser is supplied
from the Ice Maker. No additional circuit is required.
46 1/2
153/4
40 7/8
URC-20F
Air Flow
21/2
48 7/16
2 3/4 3
18 1/8
16
Liquid Refrigerant
Line
Discharge Line
Electrical Conduit
Access
Pre-Charged Tubing Kits
(Sold Separately)
20’ 404A-20610-2
35’ 404A-35610-2
55’ 404A-55610-2
URC-20F Remote Condenser (Sold Separately)
For Use with KM2000S H3
Voltage supply for the URC Remote Condenser is
supplied from the Ice Maker. No additional circuit is required.