HP HP 8360 L Series User manual

HP
8360
L-Series
Swept
CW
Generator
(Including
Options
001,
004,
and
008)
User’s
Guide
SERIAL NUMBERS
This manual applies directly to any swept CW generator with the
model and serial number prefix combination shown below. You
may have to modify this manual so that it applies directly to your
instrument version. Refer to the “Instrument History” chapter.
HP
83623L/3OL/4OL/5OL
3844A and below
Pii
HEWLETT
PACKARD
HP Part No. 08380-90134
Printed in USA
February 1999 Supersedes: September 1997

Notice
Restricted Rights
Legend
The information contained in this document is subject to change
without notice.
Hewlett-Packard makes no warranty of any kind with regard to this
material, including but not limited to, the implied warranties of
merchantability and fitness for a particular purpose. Hewlett-Packard
shall not be liable for errors contained herein or for incidental
or consequential damages in connection with the furnishing,
performance, or use of this material.
Use, duplication, or disclosure by the U.S. Government is subject
to restrictions as set forth in subparagraph (c) (1) (ii) of the
Rights of Technical Data and Computer Software clause at DFARS
252.227-7013 for DOD agencies, and subparagraphs (c) (1) and
(c) (2) of the C
ommercial
Computer Software Restricted Rights
clause at FAR 52.227-19 for other agencies.
@
Copyright Hewlett-Packard Company 1996, 1997, 1999
All Rights Reserved. Reproduction, adaptation, or translation
without prior written permission is prohibited, except as allowed
under the copyright laws.
1400 Fountaingrove Parkway, Santa Rosa, CA 95403-1799, USA

Certification
Hewlett-Packard Company certifies that this product met its
published specifications at the time of shipment from the factory.
Hewlett-Packard further certifies that its calibration measurements
are traceable to the United States National Institute of Standards
and Technology, to the extent allowed by the Institute’s calibration
facility, and to the calibration facilities of other International
Standards Organization members.
Warranty
This Hewlett-Packard instrument product is warranted against
defects in material and workmanship for a period of one year from
date of shipment. During the warranty period, Hewlett-Packard
Company will, at its option, either repair or replace products which
prove to be defective.
For warranty service or repair, this product must be returned to a
service facility designated by Hewlett-Packard. Buyer shall prepay
shipping charges to Hewlett-Packard and Hewlett-Packard shall pay
shipping charges to return the product to Buyer. However, Buyer
shall pay all shipping charges, duties, and taxes for products returned
to Hewlett-Packard from another country.
Hewlett-Packard warrants that its software and firmware designated
by Hewlett-Packard for use with an instrument will execute
its programming instructions when properly installed on that
instrument. Hewlett-Packard does not warrant that the operation
of the instrument, or software, or firmware will be uninterrupted or
error-free.
LIMITATION OF WARRANTY
The foregoing warranty shall not apply to defects resulting from
improper or inadequate maintenance by Buyer, Buyer-supplied
software or interfacing, unauthorized modification or misuse,
operation outside of the environmental specifications for the
product, or improper site preparation or maintenance.
NO OTHER WARRANTY IS EXPRESSED OR IMPLIED.
HEWLETT-PACKARD SPECIFICALLY DISCLAIMS THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE.
EXCLUSIVE REMEDIES
THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE
AND EXCLUSIVE REMEDIES. HEWLETT-PACKARD SHALL
NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER
BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL
THEORY.
. . .
III

Assistance
Product maintenance agreements and other customer assistance
agreements are available for Hewlett-Packard products. For any
assistance, contact your nearest Hewlett-Packard Sales and Service
Ofice.
Safety
Notes
The following safety notes are used throughout this manual.
Familiarize yourself with each of the notes and its meaning before
operating this instrument.
WARNING
Warning denotes a hazard. It calls attention to a procedure which, if
not correctly performed or adhered to, could result in injury or loss
of life. Do not proceed beyond a warning note until the indicated
conditions are fully understood and met.
CAUTION Caution denotes a hazard. It calls attention to a procedure that, if
not correctly performed or adhered to, would result in damage to or
destruction of the instrument. Do not proceed beyond a caution sign
until the indicated conditions are fully understood and met.
iv

General
Safety
Considerations
WARNING
n
No operator serviceable parts inside. Refer servicing to qualified
personnel. To prevent electrical shock, do not remove covers.
n
For continued protection against fire hazard replace line fuse only
with same type and rating (F 5A/250V). The use of other fuses or
material is prohibited.
w
This is a Safety Class I product (provided with a protective earthing
ground incorporated in the power cord). The mains plug shall only
be inserted in a socket outlet provided with a protective earth
contact. Any interruption of the protective conductor, inside or
outside the instrument, is likely to make the instrument dangerous.
Intentional interruption is prohibited.
n
If this instrument is used in a manner not specified by
Hewlett-Packard Co., the protection provided by the instrument may
be impaired. This product must be used in a normal condition (in
which all means for protection are intact) only.
w
Position the instrument according to the enclosure protection
provided. This instrument does not protect against the ingress of
water. This instrument protects against finger access to hazardous
parts within the enclosure.
V

CAUTION n Before switching on this instrument, make sure that the line
voltage selector switch is set to the voltage of the power supply and
the correct fuse is installed.
n Always use the three-prong ac power cord supplied with this
instrument. Failure to ensure adequate earth grounding by not
using this cord may cause instrument damage.
n Before switching on this product, make sure that the line voltage
selector switch is set to the voltage of the power supply and
the correct fuse is installed. Assure the supply voltage is in the
specified range.
n Ventilation Requirements: When installing the instrument in a
cabinet, the convection into and out of the instrument must not be
restricted. The ambient temperature (outside the cabinet) must be
less than the maximum operating temperature of the instrument
by 4
“C
for every 100 watts dissipated in the cabinet. If the total
power dissipated in the cabinet is greater than 800 watts, then
forced convection must be used.
n This product is designed for use in Installation Category II and
Pollution Degree 2 per IEC 1010 and 664, respectively.
Note The detachable power cord is the instrument disconnecting device.
It disconnects the mains circuits from the mains supply before other
parts of the instrument. The front panel switch is only a standby
switch and is not a LINE switch.
vi

PREFACE
This manual provides user information for the HP 8360 L-Series
Swept CW Generator.
Instruments
Covered
This manual applies to instruments having a serial number prefix
By
This
Manual
listed on the title page (behind the “Documentation Map” tab).
Some changes may have to be made to this manual so that it
applies directly to each instrument; refer to Chapter 5, “Instrument
History”, to see what changes may apply to your instrument.
A serial number label (Figure O-l) is attached to the instrument’s
rear panel. A prefix (four digits followed by a letter), and a suffix
(five digits unique to each instrument), comprise the instrument
serial number.
SERIAL NUMBER
h
I \
PREFIX
SUFFIX
-A
SER 1234A 12345
\I
INSTALLED
OPTIONS
!
Figure O-l. Typical Serial Number Label
User’s
Guide
Tabs divide the major chapters of this manual. The contents of each
Organization
chapter is listed in the Table of Contents.
HP
8360
L-Series
Documentation
Documentation Map
For a pictorial representation of the HP 8360 L-Series documentation,
see the ‘Documentation Map” at the front of this manual.
Ordering Manuals
A manual part number is listed on the title page of this manual.
You may use it to order extra copies of this manual. See
“Replaceable Parts” in HP 8360 B-Series Swept Signal Generator/
HP 8360 L-Series Swept CW Generator Service Guide for a complete
list of HP 8360 documentation and ordering numbers.
vii

Typeface
Conventions
The following conventions are used in the HP 8360 L-Series
documentation:
Italics Italic type is used for emphasis, and for titles of manuals and
other publications.
Computer Computer type is used for information displayed on the
instrument. For example: In this sequence, POWER LEVEL is displayed.
(Hardkeys)
Instrument keys are represented in “key cap.” You are
instructed to press a
hardkey.
Softkeys
Softkeys are located just below the display, and their
functions depend on the current display. These keys are represented
in “softkey.” You are instructed to select a softkey.
Regulatory
Information
This product has been designed and tested in accordance with IEC
Publication 1010, Safety Requirements for Electronic Measuring
Apparatus, and has been supplied in a safe condition. The
instruction documentation contains information and warnings
which must be followed by the user to ensure safe operation and to
maintain the instrument in a safe condition.
. . .
VIII

Manufacturer’s
Declaration
Note This is to certify that this product meets the radio frequency
interference requirements of Directive FTZ 1046/1984. The German
Bundespost has been notified that this equipment was put into
circulation and has been granted the right to check the product type
for compliance with these requirements.
Note: If test and measurement equipment is operated with
unshielded cables and/or used for measurements on open set-ups, the
user must insure that under these operating conditions, the radio
frequency interference limits are met at the border of his premises.
Model HP 8360 L-Series Swept CW Generator
Note Hiermit wird bescheinigt, dass dieses
Gerat/System
in
fibereinstimmung
mit den Bestimmungen von
Postverfiigung
1046/84
funkentst”rt
ist.
Der Deutschen Bundespost wurde das Inverkehrbringen dieses
Gerates/Systems
angezeight und die Berechtigung
zur
Uberpriifung
der Serie auf Einhaltung der Bestimmungen
eingeraumt.
Zustzinformation fiir Mess-und Testgerate:
Werden Mess- und Testgerate mit ungeschirmten Kabeln
und/oder
in offenen Messaufbauten verwendet, so ist vom Betreiber
sicherzustellen, dass die Funk-Entst”rbestimmungen unter
Betriebsbedingungen an seiner Grundstiicksgrenze eingehalten
werden.
ix

Declaration
of
Conformity
DECLARATION
OF
CONFORMITY
aomrding
to
lSO/lEC
Guide 22 and EN 45014
hanufacturetis
Name:
Hewlett-Packard Co.
lanufactureh
Address:
declares
that the products
Microwave Instruments
Division
1400 Fountaingrove Parkway
Santa Rosa, CA 95403-1799
USA
Product Name:
Synthesized Sweeper
Model Numbers:
HP 83623L, HP
8363OL,
HP 836401.
HP 83650L
Product Options:
This declaration covers all options of the
above products.
:onform
to the following Product specifications:
Safety: IEC
348:1978/HD
401
S1:1981
CAN/CSA-C22.2 No. 231 (Series M-89)
EMC:
CISPR
11:1990/EN
55011:1991
Group I, Class A
IEC
801-2:1984/EN 50082-1:1992
4kV
CD, 8
kV
AD
IEC
801-3:1984/EN 50082-1:1992
3
V/m, 27-500 MHz
IEC
801-4:1988/EN
50082-I:1992 0.5
kV
Sig. Lines, 1
kV
Power Lines
IEC
555-2:1982
+
Al:1985
I
EN
60555-2:1987
IEC
555-3:1982
+
Al:1990
/
EN
60555-3:1987
+ Al:1991
Supplementary Information:
-hese
products herewith comply with the requirements of the Low Voltage Directive
‘3/23/EEC and the EMC Directive 89/336/EEC and carry the CE-marking accordingly.
Voduct
safety qualification testing for these products was performed prior to 1
December 1993.
Santa
Rosa, California, USA 19 Dec. 1996
J
Manager
European Contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard
GmbH.
Deparlment HQ-TRE.
Herrenbarger
Slrasse
130, D-71 034 BBblingen. Germany (FAX +497031-l 4-3143)
X

Compliance
with
This is to declare that this instrument is in conformance with the
German
Noise
Requirements
German Regulation on Noise Declaration for Machines (Laermangabe
nach
der Maschinenlaermrerordnung -3.GSGV Deutschland).
I
Acoustic Noise Emmission/Geraeuschemission
I
LpA
<70
dB
Operator position
Normal position
per IS) 7779
LpA
<70
dB
am Arbeitsplatz
normaler Betrieb
nach
DIN 45635 t.19
Instrument
Markings
!
A
CC
“ISMl-A”
I
I
0
I
N
The instruction documentation symbol. The product is
marked with this symbol when it is necessary for the
user to refer to the instructions in the documentation.
The CE mark is a registered trademark of the European
Community.
The CSA mark is a registered trademark of the
Canadian Standards Association.
This is a symbol of an Industrial Scientific and Medical
Group 1 Class A product.
This is an ON symbol. The symbol ON is used to mark
the position of the instrument power line switch.
This is an ON symbol. The symbol ON is used to mark
the position of the instrument power line switch.
This is a STANDBY symbol. The STANDBY symbol is
used to mark the position of the instrument power line
switch.
This is an OFF symbol. The OFF symbol is used to
mark the position of the instrument power line switch.
This is an AC symbol. The AC symbol is used to
indicate the required nature of the line module input
power.
xi

Table O-l. Hewlett-Packard Sales and Service Offices
UNITED STATES
Instrument Support Center
Hewlett-Packard Company
(800) 403-0801
EUROPEAN FIELD OPERATIONS
Headquarters
France
Hewlett-Packard S.A. Hewlett-Packard France
150, Route du Nant-d’Avri1 1 Avenue Du Canada
1217 Meyrin a/Geneva Zone
D’Activite
De Courtaboeuf
Switzerland
F-91947 Les Ulis
Cedex
(41 22) 780.8111
France
(33 1) 69 82 60 60
Great Britain
Hewlett-Packard Ltd.
Eskdale Road, Winnersh Triangle
Wokingham, Berkshire RG41 5DZ
England
(44 734) 696622
Germany
Hewlett-Packard GmbH
Hewlett-Packard Strasse
61352 Bad Homburg v.d.H
Germany
(49 6172) 16-O
INTERCON
FIELD OPERATIONS
Headquarters
Hewlett-Packard Company
3495 Deer Creek Road
Palo Alto, California, USA
94304-1316
(415) 857-5027
China
China Hewlett-Packard Company
38
Bei
San
Huan
Xl Road
Shuang Yu Shu
Hai
Dian District
Beijing, China
(86 1) 2566888
Taiwan
Hewlett-Packard Taiwan
8th Floor, H-P Building
337 Fu Hsing North Road
Taipei, Taiwan
(886 2) 712-0404
Australia
Hewlett-Packard Australia Ltd.
31-41 Joseph Street
Blackburn, Victoria 3130
(61 3) 895-2895
Japan
Hewlett-Packard Japan, Ltd
9-1
Takakura-Cho, Hachioji
Tokyo 192, Japan
(81 426) 60-2111
Canada
Hewlett-Packard (Canada) Ltd.
17500 South Service Road
Trans-Canada Highway
Kirkland, Quebec
H9J
2X8
Canada
(514) 697-4232
Singapore
Hewlett-Packard Singapore (Pte.) Ltd.
150 Beach Road
#29-00 Gateway West
Singapore 0718
(65) 291-9088
xii

Contents
Contents-l
1. Getting Started
What Is In This Chapter ............
How To Use This Chapter ............
Equipment Used In Examples .........
Introducing the HP 8360 L-Series Swept CW
Generators .................
Display Area ..................
Entry Area ..................
CW Operation and Start/Stop Frequency Sweep . .
CW Operation ................
Start/Stop Frequency Sweep ..........
Center Frequency/Span Operation ........
Power Level and Sweep Time Operation ......
Power Level Operation ............
Sweep Time Operation ............
Continuous, Single, and Manual Sweep Operation
.
Marker Operation ...............
Saving and Recalling an Instrument State .....
Power Sweep and Power Slope Operation .....
Power Sweep Operation ............
Power Slope Operation ............
Getting Started Advanced ............
Externally Leveling the Swept CW Generator ...
Leveling with Detectors/Couplers /Splitters ...
External Leveling Used With the Optional Step
Attenuator ...............
Leveling with Power Meters ..........
Leveling with MM-wave Source Modules .....
Working with Mixers/Reverse Power Effects ....
Working with Spectrum Analyzers/Reverse Power
Effects ...................
Optimizing Swept CW Generator Performance ...
Creating and Applying the User Flatness Correction
Array ..................
Creating a User Flatness Array Automatically,
Example 1 ...............
Creating a User Flatness Array, Example 2 . .
Swept mm-wave Measurement with Arbitrary
Correction Frequencies, Example 3 ....
Scalar Analysis Measurement with User Flatness
Corrections, Example 4 .........
Using Detector Calibration ..........
l-l
l-2
l-2
1-3
l-4
1-5
1-6
l-6
l-6
l-8
l-10
l-10
l-10
l-12
1-14
1-16
1-18
1-18
1-19
l-21
l-23
l-23
l-26
l-27
l-28
l-30
l-32
l-33
l-33
l-34
1-36
1-39
l-43
l-47

Using the Tracking Feature ..........
Peaking ..................
Tracking .................
ALC Bandwidth Selection ............
Using Step Sweep ...............
Creating and Using a Frequency List .......
Using the Security Features ...........
Changing the Preset Parameters .........
Getting Started Programming ..........
HP-IB General Information ...........
Interconnecting Cables ............
Instrument Addresses .............
HP-IB Instrument Nomenclature ........
Listener ..................
Talker. ..................
Controller .................
Programming the Swept CW Generator .....
HP-IB Command Statements .........
Abort ...................
Remote ..................
Local Lockout ...............
Local ...................
Clear ...................
output ..................
Enter ...................
Getting Started with SCPI ...........
Definitions of Terms ..............
Standard Notation ..............
Command Mnemonics ...........
Angle Brackets ...............
How to Use Examples .............
Command Examples ............
Response Examples .............
Essentials for Beginners .............
Program and Response Messages .......
Forgiving Listening and Precise Talking ....
Types of Commands ............
Subsystem Command Trees ..........
The Command Tree Structure ........
Paths Through the Command Tree ......
Subsystem Command Tables ..........
Reading the Command Table ........
More About Commands ...........
Query and Event Commands ........
Implied Commands ............
Optional Parameters ...........
Program Message Examples .........
Parameter Types ..............
Numeric Parameters ...........
Extended Numeric Parameters .......
Discrete Parameters ...........
l-49
l-49
1-49
l-50
1-51
l-52
l-53
l-54
l-55
l-56
1-56
1-56
1-56
l-56
l-56
l-56
l-56
l-57
l-57
l-58
l-58
l-59
l-59
l-60
1-61
1-63
l-63
l-64
l-64
l-64
1-64
l-64
l-65
l-66
l-66
l-66
l-67
l-68
l-68
l-68
1-71
1-71
l-72
l-72
l-72
l-72
l-72
l-73
l-73
l-74
l-75
Contents-2

Boolean Parameters ...........
Reading Instrument Errors ..........
Example Programs ..............
Example Program .............
Description ...............
Program Listing .............
Program Comments ...........
Details of Commands and Responses .......
In This Subsection ..............
Program Message Syntax ...........
Subsystem Command Syntax ........
Common Command Syntax .........
Response Message Syntax ...........
SCPI Data Types ..............
Parameter Types ..............
Numeric Parameters ...........
Extended Numeric Parameters .......
Discrete Parameters ...........
Boolean Parameters ...........
Response Data Types ............
Real Response Data ...........
Integer Response Data ..........
Discrete Response Data ..........
String Response Data ...........
Programming Typical Measurements .......
In This Subsection ..............
Using the Example Programs .........
Use of the Command Tables .........
HP-IB Check, Example Program 1 .......
Program Comments ............
Local Lockout Demonstration, Example Program 2
Program Comments ............
Setting Up A Typical Sweep, Example Program 3
Program Comments ............
Queries, Example Program 4 ..........
Program Comments ............
Saving and Recalling States, Example Program 5 .
Program Comments ............
Looping and Synchronization, Example Program 6
Program Comments ............
Using the
*WA1
Command, Example Program 7 .
Program Comments ............
Using the User Flatness Correction Commands,
Example Program 8 ............
Programming the Status System .........
In This Subsection ..............
General Status Register Model .........
Condition Register .............
Transition Filter ..............
Event Register ...............
Enable Register ..............
l-75
l-76
1-77
l-77
l-77
l-77
l-78
l-80
l-80
l-80
1-81
1-81
l-82
l-83
l-83
l-83
l-84
l-85
l-85
l-85
l-85
1-86
l-86
l-86
1-87
l-87
l-87
l-88
l-90
l-90
l-91
l-92
l-93
l-93
l-95
l-95
l-97
l-97
l-99
1-99
l-101
l-101
l-103
l-106
l-106
l-106
l-106
l-107
l-107
l-107
Contents-3

An Example Sequence ...........
Programming the Trigger System .........
In This Subsection ..............
Generalized Trigger Model ...........
Overview .................
Details of Trigger States ...........
Inside the Idle State ...........
Inside the Initiate State ..........
Inside Event Detection States .......
Inside the Sequence Operation State ....
Common Trigger Configurations ........
The
INIT
Configuration ...........
The TRIG Configuration ..........
Description of Triggering in the HP 8360 L-Series
Swept CW Generators ...........
Advanced Trigger Configurations .......
Trigger Keyword Definitions ..........
ABORt
..................
IMMediate
................
ODELay
.................
SOURce ..................
Related Documents ...............
The International Institute of Electrical and
Electronics Engineers. ...........
Hewlett-Packard Company ...........
l-107
l-109
l-109
l-109
l-109
l-110
l-111
l-111
1-112
l-114
l-115
1-115
1-116
l-117
1-118
1-118
l-118
1-118
1-118
1-119
l-120
l-120
l-120
2. Operating and Programming Reference
How To Use This Chapter . . . . . . . . . . . .
2-1
A. Address . . . . . . . . . . . . . . . . . . . . A-l
Adrs
Menu . . . . . . . . . . . . . . . . . . A-l
(ALC).
....................
A-3
ALC Bandwidth Select Auto
..........
A-10
ALC Bandwidth Select High
..........
A-10
ALC Bandwidth Select Low
.......... A-11
ALC3WMenu .................
A-11
Altrnate Regs
................
A-12
Amp1
Markers .................
A-13
ANALYZER STATUS REGISTER ........
A-13
Arrow Keys ..................
A-16
[ASSIGN).
....................
A-17
Auto Fill
Incr
................
A-18
Auto Fill #Pts
................
A-19
Auto Fill Start
...............
A-20
Auto Fill Stop
................
A-21
Auto Track
..................
A-22
Contents-4

B.
BLankDisp
. . . . . . . . . . . . . . . . . .
B-l
C.
(CENTER)
.....................
C-l
Center=Marker
................
c-2
Clear Fault
.................
c-2
Clear Memory
.................
c-3
Clear Point
................. c-4
CONNECTORS ................ c-4
(CONT)
.....................
c-10
CopyList
..................
c-11
CorPair
Disable
...............
c-11
Coupling Factor
............... c-12
(cw
..................... c-12
CW/CF
Coupled
................
c-13
D.
Dblr Amp Menu
................
D-l
Delete Menu
.................
D-2
Delete All
..................
D-2
Delete Current
................
D-3
Delete Undef
.................
D-3
DeltaMarker
.................
D-4
Delta Mkr Ref
................
D-5
Disp Status
.................
D-5
Doubler Amp Wode AUTO
............
D-7
Doubler
Amp
Mode Off
............
D-7
Doubler
Arap
Mode On
.............
D-8
Dwell Coupled
................
D-9
E.
8360Adrs
..................
EnterCorr
..................
EnterFreq..
................
Enter List Dwell
..............
Enter List Freq
...............
Enter List Offset
..............
ENTRY KEYS .................
ENTRY ON/OFF) .................
ExtDet Cal
.................
E-l
E-l
E-2
E-2
E-3
E-4
E-4
E-5
E-5
Contents-5

F.
Fault Menu
..................
F-l
Fault Info 1
.................
F-2
Fault Info 2
................. F-3
Fault Info 3
.................
F-4
Fltness Menu
................. F-5
(FLTNEss
ON/OF)
................ F-10
Freq Cal Menu
................
F-11
Freq Follow .................
F-11
FREQUENCY
(e)
............... F-12
Freq
Mult
.................. F-13
Freq Offset
.................
F-14
FullUsr
Cal
.................
F-14
G.
Global Dwell . . . . . . . . . . . . . . . . .
G-l
Global Offset . . . . . . . . . . . . . . . .
G-l
H. HP-IB Address . . . . . . . . . . . . . . . . . H-l
HP-IB Menu . . . . . . . . . . . . . . . . . .
H-l
L.
Leveling
ModeALCof f
............. L-l
Leveling
ModeNorxtal
.............
L-2
Leveling
ModeSearch
.............
L-2
Leveling
PointExtDet
............
L-3
Leveling PointIntml
............
L-3
Leveling
PointModule
............
L-4
Leveling
PointPwrMtr
............
L-5
LINE SWITCH ................
L-5
ListMenu
..................
L-6
List
Mode
Pt
TrigAuto
............
L-8
List Mode Pt
TrigBus
............
L-9
List Mode Pt
TrigExt
............
L-9
(TEL-)
.....................
L-10
Contents-6

MI--M2
Sweep . . . .
Manual Sweep . . . .
(MARKER) . . . . . .
Marker
Mi
. . . . .
Marker M2 . . . . .
Marker M3 . . . . .
Marker M4 . . . . .
Marker
M5
. . . . .
Markers All Off . .
Measure Corr All .
Measure Corr Current
Measure Corr Undef
Meter Adss . . . . .
INIOD)
. . . . . . . .
Module Menu . . . .
Module Select AUTO
Module Select Front
Module Select None
Module Select Rear
more n/m . . . . . .
Mtr
Meas
Menu . . .
P.
Peak RF Always . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
Pulse
On/OffScal.ar
Pwr Mtr Range . . .
.............
.............
.............
.............
.............
.............
.............
.............
.............
.............
............
.............
.............
.............
.............
.............
.............
.............
.............
.............
.............
.............
.............
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Analyzr
........
CIIL
..........
SCPI
. . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
M-l
M-l
M-3
M-4
M-5
M-5
M-6
M-6
M-7
M-7
M-8
M-8
M-9
M-9
M-10
M-11
M-11
M-12
M-13
M-13
M-14
P-l
P-2
P-2
P-5
P-6
P-7
P-8
P-9
P-10
P-11
P-11
P-12
P-13
P-13
P-14
P-15
P-15
P-16
Contents-7

R.
(RECALL)
....................
R-l
Ref Osc Menu
.................
R-l
@Eqz--
..................
R-2
ROTARY KNOB ................
R-2
S.
LSAVE)
.....................
S-l
SaveLock
.................. s-2
Save User Preset
.............. s-2
SCPI Conformance Information
......... s-3
SCPI COMMAND SUMMARY
SCPI STATUS REGISTER
STRUbitiRi
.
: : : : s-12
S-48
Security Menu
................ s-50
Selftest
(Full)
...............
s-51
SetAtten
..................
s-51
[piEiF)
.....................
S-52
Software Rev
.................
S-52
@KJ
..................... s-53
(START)
..................... s-53
Start=Ml
Stop=M2
.............. s-54
Start Sweep Trigger Auto
.......... s-55
Start Sweep Trigger Bus
........... s-55
Start Sweep Trigger Ext
...........
S-56
Step Control Master
.............
S-56
Step Control Slave
.............
S-58
Step Dwell
..................
s-59
Step Points
.................
S-60
StepSize
..................
S-60
Step
Sup
Menu
................
S-61
Step
Sup
PtTrig Auto
............
S-62
Step
Sup
PtTrig Bus
.............
S-62
Step
Sup
PtTrig Ext
.............
S-63
ISTOP)
.....................
S-63
SWEEP
(MENU)
.................
S-64
Sweep Mode List
...............
S-65
Sweep Mode Ramp
...............
S-66
Sweep Mode Step
...............
S-66
Sup
Span
CalAlways
.............
S-67
Sup
Span
CalOnce
..............
S-67
(SWEEP TIME)..................
S-68
SwpTime
Auto
.................
S-68
SYSTEM
(MENU)
.................
S-69
Contents-8
This manual suits for next models
4
Table of contents
Other HP Inverter manuals