manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HP
  6. •
  7. Server
  8. •
  9. HP ProLiant DL380 User manual

HP ProLiant DL380 User manual

Other manuals for ProLiant DL380

9

This manual suits for next models

1

Other HP Server manuals

HP ProLiant ML350e Gen8 Manual

HP

HP ProLiant ML350e Gen8 Manual

HP LaserJet 9000 User manual

HP

HP LaserJet 9000 User manual

HP AlphaServer ES80 Quick start guide

HP

HP AlphaServer ES80 Quick start guide

HP ProLiant DL145 User manual

HP

HP ProLiant DL145 User manual

HP Cluster Platform Hardware Kits v2010 User manual

HP

HP Cluster Platform Hardware Kits v2010 User manual

HP BL480c - ProLiant - 4 GB RAM User manual

HP

HP BL480c - ProLiant - 4 GB RAM User manual

HP t820 User manual

HP

HP t820 User manual

HP DL360 - ProLiant - Photon User manual

HP

HP DL360 - ProLiant - Photon User manual

HP A180 Technical manual

HP

HP A180 Technical manual

HP 9000 A180C Mounting instructions

HP

HP 9000 A180C Mounting instructions

HP ProLiant DL585 Manual

HP

HP ProLiant DL585 Manual

HP PROLIANT BL45P User instructions

HP

HP PROLIANT BL45P User instructions

HP ProLiant DL360p Gen8 Manual

HP

HP ProLiant DL360p Gen8 Manual

HP Integrity BL870c User instructions

HP

HP Integrity BL870c User instructions

HP ProLiant DL560 User manual

HP

HP ProLiant DL560 User manual

HP ProLiant ML110 Assembly instructions

HP

HP ProLiant ML110 Assembly instructions

HP EX475 - MediaSmart Server - 512 MB RAM User manual

HP

HP EX475 - MediaSmart Server - 512 MB RAM User manual

HP ProLiant DL160 Gen8 User manual

HP

HP ProLiant DL160 Gen8 User manual

HP HPE ProLiant DX360 Gen10 User manual

HP

HP HPE ProLiant DX360 Gen10 User manual

HP NetServer AA 4000 User manual

HP

HP NetServer AA 4000 User manual

HP ProLiant Plus User manual

HP

HP ProLiant Plus User manual

HP 226824-001 - ProLiant - ML750 Reference manual

HP

HP 226824-001 - ProLiant - ML750 Reference manual

HP D7171A - NetServer - LPr User manual

HP

HP D7171A - NetServer - LPr User manual

HP Integrity rx5670 Operating instructions

HP

HP Integrity rx5670 Operating instructions

Popular Server manuals by other brands

Lenovo ThinkServer RD230 manual

Lenovo

Lenovo ThinkServer RD230 manual

Avocent CPS810 Installer/user guide

Avocent

Avocent CPS810 Installer/user guide

Dell PowerEdge R6615 Installation and service manual

Dell

Dell PowerEdge R6615 Installation and service manual

FreeWave HT2+ installation guide

FreeWave

FreeWave HT2+ installation guide

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

GIGA-BYTE TECHNOLOGY

GIGA-BYTE TECHNOLOGY G492-Z50 user manual

Lanner HTCA-E400 user manual

Lanner

Lanner HTCA-E400 user manual

Bull NovaScale T840 E2 user guide

Bull

Bull NovaScale T840 E2 user guide

Asus RS740-E70RS24-EG Configuration guide

Asus

Asus RS740-E70RS24-EG Configuration guide

Meinberg LANTIME M300/TCR manual 

Meinberg

Meinberg LANTIME M300/TCR manual 

ZyXEL Communications VANTAGE RADIUS 50 user guide

ZyXEL Communications

ZyXEL Communications VANTAGE RADIUS 50 user guide

Lantronix xDirect-IAP quick start guide

Lantronix

Lantronix xDirect-IAP quick start guide

Fujitsu PRIMEQUEST 2400E3 General description

Fujitsu

Fujitsu PRIMEQUEST 2400E3 General description

IBM 9040-MR9 manual

IBM

IBM 9040-MR9 manual

IBM 306m - eServer xSeries - 8849 user guide

IBM

IBM 306m - eServer xSeries - 8849 user guide

green hippo Hippotizer Nevis+ quick start guide

green hippo

green hippo Hippotizer Nevis+ quick start guide

IBM 8203-E4A Brochure & specs

IBM

IBM 8203-E4A Brochure & specs

Ruijie Cloud Class RCD6000E V3 Series user manual

Ruijie

Ruijie Cloud Class RCD6000E V3 Series user manual

Avid Technology FastServe user guide

Avid Technology

Avid Technology FastServe user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Important Safety Information
Before installing the product, read the Important Safety
Information guide included with the packaged cluster.
WARNING: To reduce the risk of personal injury
or damage to the equipment:
Observe local occupational health and safety
2313 kg requirements and guidelines for manual
50300 lb material handling.
Obtain adequate assistance to lift and stabilize
the chassis during installation or removal.
Audience Assumptions
This poster is for the person who installs, administers, and
troubleshoots clusters. HP assumes you are qualified in the
servicing of computer equipment and trained in recognizing
hazards in products with hazardous energy levels. or detailed
instructions, refer to the packaged cluster documentation CD.
Legal Notice
© 2003 Hewlett-Packard Development Company, L.P.
Microso t and Windows are trademarks o Microso t Corporation in the U.S. and
other countries.
Hewlett-Packard Company shall not be liable or technical or editorial errors or omissions
contained herein. The in ormation in this document is provided "as is" without warranty o
any kind and is subject to change without notice. The warranties or HP products are set
orth in the express limited warranty statements accompanying such products. Nothing
herein should be construed as constituting an additional warranty.
Third Edition (January 2003)
Part Number 252657-003
hp ProLiant DL380
generation 3
packaged cluster
hardware installation and
configuration poster
Getting Started
Smart Array Cluster Storage
Front Panel Components
Item Description
1 Bezel blank (bay for optional redundant controller)
2 Service port (for HP service technicians only)
3 Hot-plug Smart Array Cluster Storage Controller
4 Controller display
5 Power On/Standby button
6 Enclosure LEDs
Hot-plug SCSI hard drives
Enclosure LEDs
Item LED Description Status
1 Shared Storage Module Flashing green= Module is
operating normally.
Green/Off = Module is not
operating normally.
2 System power Green = System power is on.
Off = System is in standby
mode or power is removed
from the system.
3 Fault Amber = Fault detected in a
subsystem.
Off = No faults detected.
Rear Panel Components
Item Description
1 Interconnect blanks (required for proper airflow)
2 Power supply/blower assembly
3 AC power connectors
4 2-Port Shared Storage Module
2-Port Share Storage Mo ule LEDs
Item LED Description Status
1 Power Green = Power on
Off = Power off
2 SCSI host port A Flashing green = On/Activity
Off = Off
3 SCSI host port B Flashing green = On/Activity
Off = Off
Setup in the
Configuration Fixture
Perform the following procedures for setup of the packaged
cluster in the configuration fixture. This setup procedure
assumes the cluster will be configured in the fixture and then
transferred to another location.
WARNING: Do not stack clusters while in their
configuration fixtures. The stack can become unstable
and may tip over.
1 Installing Hardware Options
NOTE: Detailed option installation instructions are available with the
options and are also in the server setup and installation guide, the
server supplemental setup guide, and the storage system user guide
on the Documentation CD.
1. If internal server options (memory, processors, fans, and
expansion boards) need to be installed:
a. Remove the servers from the server fixture.
WARNING: To reduce the risk of personal injury or
damage to the equipment, the server must be completely
removed from the server fixture to install the internal
server options. At least two people are required to lift the
servers during installation or removal.
b. Install the internal server options.
c. Replace the servers in the server fixture.
2. Install the external server options.
3. Install the external storage system options.
2 Cabling the System in the
Configuration Fixture
NOTE: The server fixture should be placed on top of the storage
system fixture for ease in cabling the packaged cluster.
1. Connect the VHDCI SCSI cables labeled A and B from the
storage system to the servers.
IMPORTANT: Save the protective covers on the cable connectors
for use when the packaged cluster is repacked.
2. If you are configuring a Microsoft or Linux operating
system, connect the Ethernet crossover cable between the
servers. Use the same RJ-45 connector (1), NIC 1, on each
server.
3. Connect the peripheral devices such as the keyboard,
mouse, and monitor. or information on peripheral device
connections, refer to "Component and LED Identification"
on this poster.
WARNING: To reduce the risk of electric shock, fire, or
damage to the equipment, do not plug telephone or
telecommunications connectors into RJ-45 connectors.
IMPORTANT: If the Remote Insight Lights-Out Edition II (RILOE II)
board is installed in the server, be sure that you can attach the
video cable to the video connector on the rear of the RILOE II
board. The standard video connector on the server rear panel is
not used when the RILOE II board is installed. For more information,
refer to the HP Remote Insight Lights-Out Edition II User Guide on
the Documentation CD.
NOTE: If you are using a KVM switchbox, refer to the switchbox
documentation for detailed instructions.
4. Connect the power cords to the servers and storage system.
3 Powering On and Configuring
the Pa kaged Cluster
1. Power on the storage system (1) and wait for the controllers
to initialize.
IMPORTANT: You must power on the Smart Array Cluster Storage
system before powering on the servers. After powering on, wait
until the storage system startup complete message displays. It might
take up to two minutes for the system to completely power up.
2. Power on one server, (2) or (3).
IMPORTANT: Do not use the Option ROM Configuration for Arrays
(ORCA) utility to configure the Smart Array Cluster Storage. The
Array Configuration Utility must be used.
While the server boots, the ROM-Based Setup Utility (RBSU)
and the ORCA utility are automatically configured to prepare
the server for the operating system installation. To configure
these utilities manually:
 Press the F8 key when prompted during the array
controller initialization to configure the array controller
using ORCA.
 Press the F9 key when prompted during the boot
process to change the server settings, such as the
settings for language and operating system, using
RBSU. The system is set up by default for the English
language and a Microsoft Windows 2000 installation.
or more information on the automatic configuration, refer to the
HP ROM-Based Setup Utility User Guide located on the
Documentation CD.
3. Insert the SmartStart CD into the CD-ROM drive and reboot
the server. ollow the on-screen instructions to begin the
operating system installation process.
or more information on installing the operating system,
refer to the SmartStart installation poster included in the
ProLiant Essentials oundation Pack, the HP ProLiant DL3 0
Generation 3 Packaged Cluster Setup and Installation
Guide, or the operating system documentation.
4. Repeat steps 2 and 3 for the second server.
5. Set up and verify the Smart Array Cluster Storage system
and cluster operations.
IMPORTANT: For detailed information on completing the cluster
setup, refer to the HP ProLiant DL380 Generation 3 Packaged
C uster Setup and Insta ation Guide located on the Documentation
CD.
NOTE: Updated installation and cluster setup information is
periodically released in HP white papers. Go to
www.hp.com/servers/proliant/highavailability
for the most recent information.
4 Powering Down and Preparing
for Transfer
1. Shut down the operating system on each server and power
off each server.
2. Power off the storage system.
3. Remove the power cords and return them to the original
boxes.
4. Disconnect the VHDCI SCSI cables and the Ethernet
crossover cable from the servers.
5. Disconnect all other cables from the servers.
6. Replace the protective covers on the ends of the VHDCI
SCSI cables.
7. Secure the VHDCI SCSI cables and the Ethernet crossover
cable for transfer.
8. Repack the shipping components in their original
configuration. Refer to the exploded view diagram and
pictures on the packaged cluster poster as a guideline
for repacking.
Configuration is complete. The packaged cluster is ready
for transfer.
See other side of poster for setup and installation in a rack.
252657- 003
Poster Overview
This poster covers the following:
Component and LED identification
Setup in the configuration fixture
Setup and installation in a rack
HP ProLiant DL380 Generation 3
Pa kaged Cluster
The packaged cluster ships in a two-piece configuration fixture.
The server fixture holds the two ProLiant DL380 Generation 3
servers. The storage system fixture holds the Smart Array Cluster
Storage system.
Item Description
1 Two-piece configuration fixture
2 Server fixture
3 Storage system fixture
NOTE: The server fixture and the storage system fixture are
environmentally safe and recyclable. The configuration fixture
should be recycled in accordance with your local recycling
center guidelines.
Setup Preparations
Required Materials
Before setting up your packaged cluster, locate the following
materials included in the shipping box:
ProLiant DL380 Generation 3 servers
Smart Array Cluster Storage system
Power cords and cables
Rack mounting hardware and rack templates (not used
with the configuration fixture)
HP SmartStart CD
Hardware documentation and software packs
Locate the following materials not included in the packaged
cluster shipping box:
Hard drives
Server hardware options and documentation (optional)
Storage system hardware options and documentation
(optional)
Keyboard, monitor, and mouse (need two of each if not
using a switchbox)
Keyboard, video, and mouse (KVM) switchbox (optional)
Operating system CDs
Required Information Checklist
Gather the following information (dependent on the operating
system).
Server node names
Server node IP addresses and subnet masks
Cluster name (Microsoft and NetWare only)
Cluster IP address and subnet mask
IP addresses and subnet mask for the cluster interconnect
(Private network used for intracluster communications)
(Microsoft and Linux only)
Server node administrator password for each server (used
during operating system installation)
New or existing NDA Tree (NetWare only)
Domain name (Microsoft only)
Domain administrator user name and password (used during
operating system installation to have the server node join the
domain) (Microsoft only)
Domain account name and password for cluster service (this
account has special privileges on each cluster server node)
(Microsoft only)
Other network settings as needed for your operating system (for
example, default gateway address, WINS server address, and
DNS settings)
Selecting an Appropriate Site
Select an installation site that meets the following requirements.
Space Temperature
Power Rack
Grounding Airflow
Detailed installation site requirements are described in the
server user guide on the Documentation CD.
Component and LED Identifi ation
ProLiant DL 80 Generation Server
Front Panel Components
Item Description
1 Hard drive bays
2 Bay for tape drive or hard drive and tape drive blank
Front Panel LEDs an Buttons
Item Description Status
1 Internal health LED Green = Normal
Amber = System degraded.
Refer to system board LEDs
to identify component in
degraded state.
Red = System critical. Refer to
system board LEDs to identify
component in critical state.
2 External health LED Green = Normal
(power supply) Amber = Power
redundancy failure
Red = Critical power
supply failure
3 NIC 1 link/activity LED Green = Network link
4 NIC 2 link/activity LED Flashing = Network link
and activity
Off = No link to network. If
power is off, view the rear
panel RJ-45 LEDs for status.
5 UID LED button Blue = Activated
Flashing = System remotely
managed
Off = Deactivated
6 Power On/Standby Green = System on
button/system power Amber = System shut down, but
LED power still applied.
Off = Power cord not attached
or power supply failure.
Rear Panel Components
Item Description Connector Color
1 Hot-plug PCI-X N/A
expansion slot 3
(bus 6) 64-bit/
100-MHz 3.3v
2 Hot-plug PCI-X N/A
expansion slot 2
(bus 6) 64-bit/
100-MHz 3.3v
3 Non-hot-plug PCI-X N/A
expansion slot 1 (bus 3)
64-bit/133-MHz 3.3v
4 Serial connector Teal
5 iLO connector N/A
6 Mouse connector Green
Power cord connector N/A
8 Keyboard connector Purple
9 NIC 1 connector N/A
10 NIC 2 connector N/A
11 USB connectors Black
12 Video connector Blue
13 VHDCI SCSI connector (port 1) N/A
Rear Panel LEDs an Buttons
Item Description LED Color Status
1 PCI Hot Plug Amber On = Expansion board
fault LED (slot 3) failed.
Off = Normal
2 PCI Hot Plug Green On = Power is applied
power LED to the slot.
(slot 3) Flashing = Power is
cycling.
Off = Power is not
applied to the slot.
3 PCI Hot Plug Amber On = Expansion board
fault LED (slot 2) failed.
Off = Normal
4 PCI Hot Plug Green On = Power is applied
power LED to the slot.
(slot 2) Flashing = Power is
cycling.
Off = Power is not
applied to the slot.
5 RJ-45 link LED Green On = Linked to
network
Off = Not linked to
network
6 RJ-45 activity Green On or flashing =
LED Network activity
Off = No network
activity
UID LED button Blue On = Activated
Flashing = System
remotely managed.
Off = Deactivated
8 Power supply Green On = Power turned on
LED and power supply
functioning properly.
Off = One or more of
the following
conditions exists:
AC power
unavailable
Power supply failed
Power supply in
standby mode
Power supply
exceeded current limit
3 Diskette drive
4 CD-ROM drive
4. Slide the back end of the left rack rail into the inside rear
of the rack. Be sure that the pins extend through the holes
marked during the rack template procedure.
IMPORTANT: Be sure that the scissor-type locking latches engage
when the ends of the rail seat into the rack uprights.
5. Repeat steps 3 and 4 for the right rack rail.
6. Remove the hook-and-loop fasteners (1) securing the
VHDCI SCSI cables and the Ethernet crossover cable to the
storage fixture.
7. Disconnect and remove the VHDCI SCSI cables from the
storage system.
8. Loosen the thumbscrews that secure the storage system and
slide the storage system from the storage system fixture.
9. Align the storage system with the rails and slide it into the
rack.
WARNING: The storage system weight, as assembled for
shipping, exceeds 22. kg (50 lb). To reduce the risk of
personal injury or damage to the equipment, at least two
people are required to lift the storage system during
removal or installation. Install the storage system in the
lowest available position in the rack.
WARNING: Always use at least two people to lift a
storage system into the rack. If the system is being loaded
into the rack above chest level, a third person must assist
with aligning the system with the rails while the other two
people support the weight of the system.
CAUTION: To prevent storage system damage and to
ease insertion, support the weight of the storage system
and keep it level when sliding the storage system into the
rack.
10. Secure the storage system to the rack.
Setup and
Installation in a Rack
Perform the following procedures to set up the packaged
cluster in a rack.
WARNING: To reduce the risk of personal injury or
damage to the equipment, at least two people are
required to lift the components during installation
or removal.
Ra k Planning Resour es
The rack resource kit ships with Compaq or HP 7000-, 9000-,
and 10,000-series racks. or more information on the content of
each resource, refer to the rack Documentation CD.
1 Installing the Storage System in
the Ra k
The rack-mounting hardware kit provides the required
components for quick deployment in Compaq branded, HP
branded, and most square-and round-hole third-party racks.
The adjustable feature of the rack rails enables installation in
racks with depths of 69.90 to 73.81 cm (27.52 to 29.06
inches).
If you are installing the Smart Array Cluster Storage system in
an M-Series rack, contact an authorized reseller to obtain an
M-Series Rack Rail option kit.
1. Locate the following materials necessary for installing the
storage system.
Item Description
1 Rack rail (left)
2 Rack rail (right)
3 Pins for round-hole rack conversion
4 4U rack template
IMPORTANT: Install the storage system in the rack, leaving enough
space above to install the servers. The following procedure details
installation in a square-hole rack. For installation procedures
concerning round-hole racks, refer to the HP Smart Array C uster
Storage System User Guide on the Documentation CD.
2. Use the instructions provided on the rack template to mark
the rack for rail locations.
WARNING: The storage system weight, as assembled for
shipping, exceeds 22. kg (50 lb). Install the storage
system in the lowest available position in the rack.
IMPORTANT: Unless you are converting the rails for use in
round-hole racks, o not remove the pins from the ends of the
rack rails. These load-bearing pins are designed to fit through
the holes without being removed.
NOTE: Identify the left (L) and right (R) rack rails by the markings
stamped into the sheet metal.
3. Insert the front end of the left rack rail into the inside front
of the rack. Be sure that the pins extend through the holes
marked during the rack template procedure.
IMPORTANT: Be sure that the scissor-type locking latches engage
when the ends of the rail seat into the rack uprights.
11. Use the shipping bracket to secure the system in the rack
for shipping:
a. Loosen the thumbscrew on the shipping bracket.
b. Slide the shipping bracket forward until it engages the
storage system chassis.
c. Tighten the thumbscrew.
2 Installing the Servers in the Ra k
ollow the steps in this section if you are installing the servers in
a Compaq or HP 7000-, 9000-, or 10,000-series rack or a
third-party rack with square holes. If you are installing the
servers in an HP Rack System/E and HP Systems round-hole
rack or a third-party rack with round holes, or if the supplied
rails do not fit the square-hole rack you are using, order the
third-party option kit for racks with round holes and use the
installation instructions that ship with the option kit.
1. Locate the following materials necessary for installing the
servers.
Item Description
1 Left and right standard rack rail assemblies
2 Server rails
3 Rack template
4 Cable management arm
2. Mark the rack.
CAUTION: Always plan the rack installation so that the
heaviest item is on the bottom of the rack. Install the
heaviest item first, and continue to populate the rack from
the bottom to the top.
3. Loosen the thumbscrews that secure the servers and slide
the servers from the server fixture.
4. Secure each server rail to the server.
5. Secure the left and right standard rack rails to the
appropriate side of the rack.
6. Extend the slides from the standard rack rails, and then
slide the server rails into the slides.
WARNING: To reduce the risk of personal injury or
equipment damage, be sure that the rack is adequately
stabilized before sliding the server rails into the rack
rails.
CAUTION: Be sure to keep the server parallel to the floor
when sliding the server rails into the rack rails. Tilting the
server up or down could result in damage to the rails.
7. Press the rail-release latches and slide the server into the
rack.
WARNING: To reduce the risk of personal injury, be
careful when pressing the server rail release latches and
sliding the server into the rack. The sliding rails could
pinch your fingers.
8. Secure the server to the rack.
9. Repeat steps 1 through 8 for the second server.
3 Installing Hardware Options
IMPORTANT: If your system was previously configured, skip to
"Cabling the System in a Rack."
NOTE: Detailed option installation instructions are available with the
options and are also in the server setup and installation guide, the
server supplemental setup guide, and the storage system user guide
on the Documentation CD.
1. Install the server options.
2. Install the storage system options.
IMPORTANT: Tightening of the shipping bracket is only necessary if
the rack is to be shipped with the Smart Array Cluster Storage
system installed.
NOTE: Figures show one server already installed in the rack.
4 Cabling the System in a Ra k
NOTE: It is recommended, for ease of cabling, to install one cable
management arm on a server and route the cables before installing
the second cable management arm.
1. Secure the cable management arm bracket to the server.
NOTE: The cable management arm is removed for clarity.
2. Secure the cable management bracket to the rail.
3. Connect the VHDCI SCSI cables labeled A and B from the
storage system to the servers.
4. If you are configuring a Microsoft or Linux operating
system, connect the Ethernet crossover cable between the
servers. Use the same RJ-45 connector (1), NIC 1, on each
server.
5. Connect peripheral devices such as the keyboard, mouse,
and monitor. or information on peripheral device
connections, refer to "Component and LED Identification"
on this poster.
WARNING: To reduce the risk of electric shock, fire, or
damage to the equipment, do not plug telephone or
telecommunications connectors into RJ-45 connectors.
IMPORTANT: If the RILOE II board is installed in the server, be sure
that you can attach the video cable to the video connector on the
rear of the RILOE II board. The standard video connector on the
server rear panel is not used when the RILOE II board is installed.
For more information, refer to the HP Remote Insight Lights-Out
Edition II User Guide on the Documentation CD.
NOTE: If you are using a KVM switchbox, refer to the switchbox
documentation for detailed instructions.
6. Connect the power cords to the servers and storage system.
IMPORTANT: Do not power on the servers or the storage system
until instructed to power on.
7. Route the cables and secure to the cable management
arm.
8. Connect the power cords to the AC power source.
WARNING: To reduce the risk of electric shock or
damage to the equipment:
Do not disable the power cord grounding plug. The
grounding plug is an important safety feature.
Plug the power cord into a grounded (earthed) electric
outlet that is easily accessible at all times.
Unplug the power cord from the power supply to
disconnect power to the equipment.
Do not route the power cord where it can be walked
on or pinched by items placed against it. Pay
particular attention to the plug, electric outlet, and the
point where the cord extends from the server.
5 Powering On and Configuring
the Pa kaged Cluster in a Ra k
1. Power on the storage system (1) and wait for the controllers
to initialize.
IMPORTANT: You must power on the Smart Array Cluster Storage
system before powering on the servers. After powering on, wait
until the storage system startup complete message displays. It might
take up to two minutes for the system to completely power up.
2. Power on one server, (2) or (3).
IMPORTANT: Do not use the Option ROM Configuration for Arrays
(ORCA) utility to configure the Smart Array Cluster Storage.
IMPORTANT: If your system was previously configured, power on
the second server. The installation process is complete.
While the server boots, the ROM-Based Setup Utility (RBSU)
and the ORCA utility are automatically configured to prepare
the server for the operating system installation. To configure
these utilities manually:
 Press the F8 key when prompted during the array
controller initialization to configure the array controller
using ORCA.
 Press the F9 key when prompted during the boot
process to change the server settings, such as the
settings for language and operating system, using
RBSU. The system is set up by default for the English
language and a Microsoft Windows 2000 installation.
or more information on the automatic configuration, refer to the
HP ROM-Based Setup Utility User Guide located on the
Documentation CD.
3. Insert the SmartStart CD into the CD-ROM drive and reboot
the server. ollow the on-screen instructions to begin the
operating system installation process.
or more information on installing the operating system,
refer to the SmartStart installation poster included in the
ProLiant Essentials oundation Pack, the HP ProLiant DL3 0
Generation 3 Packaged Cluster Setup and Installation
Guide, or the operating system documentation.
4. Repeat steps 2 and 3 for the second server.
5. Set up and verify the Smart Array Cluster Storage system
and cluster operations.
IMPORTANT: For detailed information on completing the cluster
setup, refer to the HP ProLiant DL380 Generation 3 Packaged
C uster Setup and Insta ation Guide located on the Documentation
CD.
NOT : Updated installation and cluster setup information is
periodically released in HP white papers. Go to
www.hp.com/servers/proliant/highavailability
for the most recent information.
The installation is complete.