1.SAFETY PRECAUTIONS AND PROCEDURES..........................................................2
1.1.Preliminary instruction..........................................................................................................2
1.2.During use............................................................................................................................2
1.3.After use...............................................................................................................................2
2.GENERAL DESCRIPTION...........................................................................................3
3.PREPARATION FOR USE...........................................................................................3
3.1.Initial checks ........................................................................................................................3
3.2.Power supply .......................................................................................................................3
3.3.Storage ................................................................................................................................3
4.NOMENCLATURE........................................................................................................4
4.1.Instrument description..........................................................................................................4
4.2.Display description...............................................................................................................4
4.3.Function key description ......................................................................................................5
4.3.1.ON/OFF key.................................................................................................................................5
4.3.2.UTP and STP keys......................................................................................................................5
4.3.3.GO key.........................................................................................................................................5
4.3.4.and /keys.........................................................................................................................5
4.3.5.Auto Power OFF feature..............................................................................................................5
5.OPERATING INSTRUCTIONS.....................................................................................6
5.1.Cabling test verify.................................................................................................................6
5.2.Cabling errors.......................................................................................................................7
5.3.Split pairs explanation note..................................................................................................9
6.MAINTENANCE .........................................................................................................10
6.1.General informations..........................................................................................................10
6.2.Battery replacement...........................................................................................................10
6.3.Cleaning.............................................................................................................................10
6.4.End of life...........................................................................................................................10
7.TECHNICAL SPECIFICATIONS ................................................................................11
7.1.Technical specifications.....................................................................................................11
7.2.General specifications........................................................................................................11
7.3.Environment.......................................................................................................................11
7.3.1.Environmental conditions ..........................................................................................................11
7.4.Accessories........................................................................................................................11
7.4.1.Standard accessories................................................................................................................11
7.4.2.Optional accessories.................................................................................................................11
8.SERVICE....................................................................................................................12
8.1.Warranty conditions ...........................................................................................................12
8.2.Service...............................................................................................................................12

QUICKLAN 6055
EN - 2
1. SAFETY PRECAUTIONS AND PROCEDURES
CAUTION
For your own safety as well as that of the apparatus you are recommended to
follow the procedures described in this instruction manual and carefully read
all the notes preceded by the symbol . No compliance with the CAUTIONS
and/or Instructions may damage the apparatus and/or its components or injure
the operator.
1.1. PRELIMINARY INSTRUCTION
Read this instruction manual and the instrument’s one before starting use.
Any instruction preceded by the caution symbol must be observed in order to avoid
accidents or damages.
Check that battery has been correctly placed.
Only qualified personnel practicing applicable safety precautions must use this product.
Do not perform any measurement under conditions beyond the limits specified in this
manual.
CAUTION
Connect the tester only to inactive cables. Connection to active telephone
lines and networks may damage the instrument.
1.2. DURING USE
Read carefully the following recommendations and instructions:
CAUTION
If the display shows the symbol “ ” interrupt testing and replace batteries.
Never replace batteries while the instrument is connected to conductors.
Do not use the instrument if damaged.
Do not use the instrument outdoor.
Do not perform measurements under environmental conditions beyond the limits
specified in § 7.3.1.
Do not expose the instrument to water splashes.
1.3. AFTER USE
After using the instrument switch it off.
Remove batteries if you expect not to use the instrument again for a long period.

QUICKLAN 6055
EN - 3
2. GENERAL DESCRIPTION
The instrument allows the followed functions:
Wire mapping test on LAN cables with RJ45 connector
Test on UTP and STP cables
Up to 6 error conditions identified
Recognition of up to 8 remote units
Pass/Fail indications
Backlight
Auto Power OFF
3. PREPARATION FOR USE
3.1. INITIAL CHECKS
This instrument was checked both mechanically and electrically prior to shipment. All
possible cares and precautions were taken to let you receive the instrument in perfect
conditions. Notwithstanding we suggest you to check it rapidly (eventual damages may
have occurred during transport). Make sure that all standard accessories mentioned in §
7.4.1 are included. Should you have to return back the instrument for any reason please
follow the instructions mentioned in § 8.
3.2. POWER SUPPLY
The instrument is battery supplied with 1x9V alkaline battery type IEC 6F22 included in the
package. When the “ ” low battery indication symbol is displayed replace it immediately,
following the instructions given in § 6.2. Don’t replace the battery while the instrument is
connected to the plant.
3.3. STORAGE
After a period of storage in extreme environmental conditions exceeding the limits
mentioned in § 7.3 let the instrument return to normal measuring conditions before using it.

QUICKLAN 6055
EN - 4
4. NOMENCLATURE
4.1. INSTRUMENT DESCRIPTION
CAPTION:
1. RJ45 input terminal
2. LCD display
3. UTP key
4. STP key
5. GO key
6. key
7. / key
8. ON/OFF key
9. Remote
units #1 ~ #2
Fig. 1: Instrument description
4.2. DISPLAY DESCRIPTION
CAPTION:
1. Type of selected cable
2. Low battery indication
3. Final test outcome
4. Running test indication
5. Fault test indication
6. Caution and remote unit
number indications
7. Error numbers and input
voltage indications
8. RJ45 cable couples and
S shield indications
9. Error type indications
Fig. 2: Display description

QUICKLAN 6055
EN - 5
4.3. FUNCTION KEY DESCRIPTION
4.3.1. ON/OFF key
By pushing ON/OFF key permits to turn on the instrument. For an instant all display
segments light up, then the firmware release appears on the top right side. When “on” is
displayed the instrument is ready to start (see Fig. 3)
Fig. 3: Initial screen of instrument
By pushing long (>1s) ON/OFF key to switch off the instrument
4.3.2. UTP and STP keys
By pressing UTP or STP keys it’s possible to select the type of cable to be tested, with the
following difference: STP performs also tests on the shield (continuity and proper
connections) while UTP doesn’t. Consequently STP must be pressed for all shielded
cables such as: FTP (Foiled Twisted Pair cable), STP (Shielded Twisted Pair cable), SSTP
(Shielded/Shielded Twisted Pair cable) and SFTP (Shielded/Foiled Twisted Pair cable)
CAUTION
By default the selected cable is STP. Any time the instrument is turned off
and on such type of cable is automatically selected
4.3.3. GO key
By pushing GO key to activate the wire mapping test of LAN cable connected between the
instrument’s input and the remote unit used (see § 5.1).
4.3.4. and /keys
By pushing or /keys for the selection of the errors detected by the instrument at
the end of wire mapping test on cable (see § 5.2).
By pushing long (>2s) of UNIT/ key permits to activate/disable the backlight
4.3.5. Auto Power OFF feature
The instrument is provided with Auto Power OFF (APO) feature which automatically
permits to switch it off after approx..4 minutes of idleness in order to preserve the internal
battery.

QUICKLAN 6055
EN - 6
5. OPERATING INSTRUCTIONS
5.1. CABLING TEST VERIFY
The wire mapping of RJ45 LAN cables is tested in accordance with its defined cabling
layout. To test a cable perform the below steps:
1. Switch on the instrument by pushing the ON/OFF key
2. Select the type of cable UTP or STP under test (see § 4.3.2).
3. Connect the cable under test to the meter and to the remote unit by using if necessary
through supplied patch cables (see Fig. 4)
Fig. 4: Instrument connection
4. Press GO key. The message “MEASURING…” is shown and the instrument performs
all tests related to the selected type of cable
CAUTION
The remote unit must be necessarily connected otherwise no
measurement is performed
5. If cabling is correct, a screen like this is displayed
(OK). The identification number refers to the remote
identifier connected to the other end of the cable
being tested.

QUICKLAN 6055
EN - 7
6. If cabling is not correct, a screen like this is
displayed. Referring to this example:
“NOT OK” indication and caution symbol means
that the test have given some errors
“FAULT 1/3” means that the detected errors are 3,
of which the first one is currently displayed. By
pressing or /keys it’s possible to run over the
remaining screens and display other cabling errors
Details on the detected error are given on the left
side: e.g: the couple 1-2 is OPEN
7. If the instrument detects the presence of a voltage >
0.2V on the RJ45 input, it shows the message in the
screen on the right and do not perform the test.
Eliminate the cause of the presence of voltage (e.g.:
coupling due to the presence of electrical cables
close to cable of LAN networks). The maximum
allowed voltage between inputs is 24V
CAUTION
It’s indispensable to select the right type of cable. If UTP is selected although
a STP cable is tested, test results may be not reliable due to the shield
affecting the measurement.
5.2. CABLING ERRORS
Cabling error Description Visualization Mapping
OPEN PAIR
One or both
conductors of the
pair are interrupted
(open)
REVERSED PAIR The conductors of
the same pair are
reversed

QUICKLAN 6055
EN - 8
SHORTED CABLES Two conductors are
in short circuit
between each other
TRANSPOSED
(CROSSED) PAIRS Two pairs are
crossed
MISWIRE
Generic cabling
error, such as for
example two
conductors belonging
to different pairs are
exchanged
SPLIT PAIRS
The pin to pin
correspondence is
hold, but physically
the conductors of two
pairs are crossed

QUICKLAN 6055
EN - 9
5.3. SPLIT PAIRS EXPLANATION NOTE
A LAN cable contains 8 conductors, twisted two by two thus forming 4 pairs: 1-2, 3-6, 4-5,
7-8. The error “SPLIT PAIRS” consists in the exchange of two conductors belonging to
different pairs. The pin to pin correspondence seems intact, but physically the conductors
of two couples are split. Such interaction hardly affects (or even makes impossible) the
exchange of data at high frequency/speed.
Fig. 5: Description of “Split pairs” error
CAUTION
The error condition “SPLIT PAIRS” is verified only when the cable mapping is
fully correct.

QUICKLAN 6055
EN - 10
6. MAINTENANCE
6.1. GENERAL INFORMATIONS
1. Whether in use or in storage, please do not exceed the specification requirements to
avoid possible damages or dangers
2. Do not place this meter at high temperatures or humidity or expose it to direct sunlight
3. Be sure to turn off the meter after use. If you expect not to use the tester for a long
time, remove the battery in order to avoid leakages of battery liquid that would damage
the internal parts
6.2. BATTERY REPLACEMENT
When “ ” appears on the display, replace the battery.
CAUTION
Only skilled technicians can open the instrument and replace batteries.
Before removing batteries disconnect the test leads from any energized
circuits to avoid electrical shocks.
1. Switch off the instrument
2. Remove the temperature probe
3. Remove the battery cover
4. Remove the battery from the battery fastener
5. Set the new battery into battery fastener, and return it to the battery case
6. Replace the battery cover
7. Use the appropriate battery disposal methods for Your area
6.3. CLEANING
To clean the instrument use a soft dry cloth. Never use a wet cloth, solvents or water.
6.4. END OF LIFE
CAUTION: this symbol indicates that equipment and its accessories shall be
subject to a separate collection and correct disposal.

QUICKLAN 6055
EN - 11
7. TECHNICAL SPECIFICATIONS
7.1. TECHNICAL SPECIFICATIONS
Connectors
LAN input connectors RJ45
Cables which can be tested
Cable type UTP, STP
Category CAT3, 5, 5E, 6, 6A, 7
Reference guideline: TIA/EIA 568B
Max height of use: 2000m (6562ft)
Length up to 200m (656ft)(1)
(1) To perform the test “SPLIT PAIR” the cable must be at least 1m (3.3ft) long
7.2. GENERAL SPECIFICATIONS
Mechanical features
Dimensions (L x W x H): 190 x 65 x 45mm (7 x 3 x 2in)
Weight (with battery): 235g (8 ounces)
Dimensions rem.units (L x W x H): 30 x 25 x 27mm (1 x 1 x 1in)
Weight remote units: 13g (0.5ounces)
Mechanical protection: IP40
Power supply
Battery type 1x9V type IEC 6F22
Battery life ca 600h (backlight OFF), ca 16h (backlight ON)
Auto Power OFF; after 4 minutes of idleness (not disabled)
7.3. ENVIRONMENT
7.3.1. Environmental conditions
Working temperature 0°C ÷ 40 °C (32°F ÷ 104°F)
Relative humidity <80%RH
Storage temperature 0°C ÷ 40°C; (32°F ÷ 104°F)
Storage humidity <80%RH
This product conforms to the prescriptions of the EMC directive 2014/30/EU
This instrument satisfies the requirements of 2011/65/EU (RoHS) directive and
2012/19/EU (WEEE) directive
7.4. ACCESSORIES
7.4.1. Standard accessories
Remote unit #1 CH1
Remote unit #2 CH2
Patch cables RJ45/RJ45, STP, 20cm, 3 pcs YAAMS0000000
Battery
Carrying bag
User manual
7.4.2. Optional accessories
Remote unit #3 and cable RJ45/RJ45 STP REM3
Remote unit #4 and cable RJ45/RJ45 STP REM4
Remote unit #5 and cable RJ45/RJ45 STP REM5
Remote unit #6 and cable RJ45/RJ45 STP REM6
Remote unit #7 and cable RJ45/RJ45 STP REM7
Remote unit #8 and cable RJ45/RJ45 STP REM8
Remote units #3 - #8 + 6 cables RJ45/RJ45 STP REM38

QUICKLAN 6055
EN - 12
8. SERVICE
8.1. WARRANTY CONDITIONS
This instrument is guaranteed for one year against material or production defects, in
accordance with our general sales conditions. During the warranty period the manufacturer
reserves the right to decide either to repair or replace the product. Should you need for
any reason to return back the instrument for repair or replacement take prior agreements
with the local distributor from whom you bought it. Use only original packaging. Any
damage occurred in transit due to not original packaging will be charged anyhow to the
customer.
The warranty doesn’t apply to:
Accessories and batteries (not covered by warranty).
Repairs made necessary by improper use (including adaptation to particular
applications not foreseen in the instructions manual) or improper combination with
incompatible accessories or equipment.
Repairs made necessary by improper shipping material causing damages in transit.
Repairs made necessary by previous attempts for repair carried out by not skilled or
unauthorized personnel.
Instruments for whatever reason modified by the customer himself without explicit
authorization of our Technical Dept.
The contents of this manual may not be reproduced in any form whatsoever without the
manufacturer’s authorization.
Our products are patented and our logotypes registered. We reserve the right to
modify specifications and prices in view of technological improvements or
developments which might be necessary.
8.2. SERVICE
Shouldn’t the instrument work properly, before contacting your distributor make sure that
batteries are correctly installed and working, check the test leads and replace them if
necessary. Should the instrument still operate improperly check that the operation
procedure is correct and conforms to the instructions given in this manual. If the instrument
is to be returned to the after-sales service or to a dealer transportation costs are on the
customer’s behalf. Shipment shall be however agreed upon. A report must always be
enclosed to a rejected product stating the reasons of its return. To ship the instrument use
only the original packaging material; any damage that may be due to no-original packing
shall be charged to the customer.
Table of contents
Other HT Instruments Test Equipment manuals
Popular Test Equipment manuals by other brands

Tektronix
Tektronix MSO54B Service manual

Hioki
Hioki 9262 user manual

ACS
ACS WR3 troubleshooting guide

MULTI MEASURING INSTRUMENTS
MULTI MEASURING INSTRUMENTS M-260 instruction manual

MAHA Maschinenbau Haldenwang
MAHA Maschinenbau Haldenwang MLT 1000 Original operating instructions

Q-see man inter'l
Q-see man inter'l Resitest-400M instruction manual