Huato S1500 Series User manual

User’s Guide
S1500 Portable Paperless Data
Logger Operational Instructions

Copyright
About the Instructions
Statement of responsibility
Any part of this instruction, including words, pictures and graphics, belongs to Shenzhen
HUATO Electric Co., Ltd. or its subsidiary (hereinafter referred to as "the company" or
"HUATO"). Without written permission, no unit or individual is allowed to extract, copy, trans-
late or modify all or part of the instructions in any way. In temrs of this statement, without
other aggreement, the company does not provide any express or implied representation or
warranty.
The products described in the Instructions are for sale and use worldwide.
The Instruction are used as guideline. The photos, figures, charts and illustrations provided
in the description are only for the purpose of explanation and illustration. There may be
differences between the description and the real product, please refer to the real product.
Due to product version upgrade or other requirements, the company may update the Instruc-
tions. If you need the latest version of the Instructions, please visit the company's official
website( www.huato.cn )。
HUATO recommends that you use the Instructions under the guidance of professionals.
To the maximum extent permitted by law, the products described in the instructions (includ-
ing hardware, software, firmware, etc.) are provided "according to the status quo" and may
have defects, errors or faults. The company does not provide any express or implied warran-
ty, including but not limited to the warranty of merchantability, quality satisfaction, adapt-
ability for a specific purpose, non infringement of the rights of a third party, etc.; nor does the
company guarantee Any special, incidental, incidental or indirect damages caused by the
use of this instruction or the company's products, including but not limited to the loss of busi-
ness profits, data or documents.
If you connect the products to the Internet, you need to bear your own risks, including but not
limited to network attack, hacker attack, virus infection, etc. the company will not be respon-
sible for the abnormal work of the products, information leakage and other problems caused
by the products, but the company will provide you with product related technical support in
a timely manner.
When using this product, please strictly follow the applicable laws. If this product is used to
infringe the rights of a third party or other improper use, the company will not take any
responsibility.
In case of any conflict between the contents of this statement and the applicable law, the
provisions of the law shall prevail.
Introduction

Attentions
1) The waterproof grade of the product is IP34. If there is moisture on the shell, do not
connect the logger with USB in order to prevent from short circuit. Short circuit may
cause damage to the instrument.
2)The logger adopts ABS engineering fireproof plastic shell to prevent from the corro-
sion of acid, alkali and other chemicals. In case of failure, it must be repaired by
authorized professionals and please do not repair or refit by yourself. One 9V alkaline
battery equipped within this instrument cannot be charged and short circuit is not
allowed, otherwise danger may occur. Please properly dispose of the waste battery
to protect the environment.
Serial number Version number Document number Revision date
Introduction

Table of Contents
1.1 Introductions.............................................................................................1
1.2 Appearance..............................................................................................1
1.3 Features...................................................................................................1
1.4 Models.....................................................................................................2
1.5 Device Overview.......................................................................................2
1.6 Buttons and Ports.....................................................................................3
1.7 Operational Steps.....................................................................................4
1.8 Technical Specifications.............................................................................5
1.8.1 General Specifications.............................................................................5
1.8.2 Input Specifications................................................................................6
3.1 Connection mode......................................................................................8
4.1 Prompt Bar..............................................................................................10
4.2 Home Page.............................................................................................10
4.3 Digital Display.........................................................................................10
4.4 Bar Chart Display.....................................................................................11
4.5 Real Time Curve.......................................................................................12
4.6 Historical Curve.......................................................................................13
4.7 Start / Stop Recording..............................................................................14
4.8 Data Storage...........................................................................................15
4.8.1 Recording File.......................................................................................15
4.8.3 Operational Log....................................................................................15
4.8.3 Alarm Log............................................................................................15
4.9 Channel Settings......................................................................................15
4.9.1 Channel Settings....................................................................................16
4.9.2 Alarm Settings.......................................................................................16
4.9.3 Calibration Settings...............................................................................17
4.10 System Settings......................................................................................18
4.10.1 System Information and Program Upgrade.............................................18
4.10.2 Systems Display...................................................................................19
4.10.3 Sampling and Storage..........................................................................19
4.10.4 Network Settings..................................................................................19
4.11 Web settings..........................................................................................20
S1500 Series
Table of
Contents
Section 1 Product Introductions...............................................................................1
Section 2 Attentions...............................................................................................7
Section 3 Wiring Instructions..................................................................................8
Section 4 Interface and function description............................................................9

1.1 Introductions
1.2 Appearance
1.3 Features
1
1. Multi-channel input, supports up to 16 channels of input.
2. Support multiple signal types input, support multiple signal input such as DC
voltage, DC current, thermocouple, RTD, NTC, frequency, pulse count, etc.
3. Support multiple types of thermocouple input, wide temperature detection range
(-270-2320℃).
4. With rich peripheral interfaces such as USB, TF card, RJ45, etc., it can export and
transfer recorded files through U disk and external TF card, and conduct real-time
data monitoring on WEB through the RJ45 interface.
5. It has the signal acquisition function of current and voltage transmitters, and each
part is self-defining to display, which is convenient for connecting different types of
sensor transmitters.
6. High-rate sampling, 16-channel signal acquisition is completed within 1S.
7. The data storage capacity is large, a single record file can record up to 100,000
records, and the total data storage capacity is at least 8 million records.
8. With rich data display and analysis functions, it can show digital display, bar
graph display, single-channel detailed information display, real-time curve drawing
and historical curve query.
9. It has multiple recording modes such as immediate recording, timing recording,
and timing stop, making the recording function more convenient and intelligent.
The S1500 series product is a portable paperless data logger. With 8/12/16 channel universal
input and thermocouple input function, it can detect thermocouple, RTD, NTC, DC current, DC
voltage, frequency, pulse count and other signals at the same time, and the collected data can
be vividly displayed through various forms such as digital interface, bar graph interface,
real-time curve, etc. The device has rich peripheral interfaces such as USB, TF card, RJ45, WIFI,
etc. It is a portable recording instrument with rich functions, highly integrated and intelligent.
Section 1 Product Introductions
S1500 Series
1

1.4 Models
1.5 Device Overview
Handheld Mode
Note:Don’t block the cold junction compensation holes, which may affect the
accuracy of data acquisition.
Wall Hanging Mode
The device is suspended on the wall by two hanging holes on the back of the device.
2
Mounting Hole Mounting Hole
S1500 Series
1
S1508U
S1512U
S1516U
S1508T
S1512T
S1516T
8 Channels thermocouple inputs
12 Channels thermocouple inputs
16 Channels thermocouple inputs
8 Channels thermocouple inputs
12 Channels thermocouple inputs
16 Channels thermocouple inputs
Models Function description

1.6 Buttons and Ports
Tabletop Kickstand
Use the supporting plate on the back to make the device stand on the desktop
3
S1500 Series
1
SD Card
USB Card
Type-C
Mounting Hole Mounting Hole
RJ45 Port
Alarm Output Port
Home
Power On/Of

1.7 Operational Steps
Note: Please configure the channels before starting recording, otherwise cannot view
digits/bar charts/real-time curves may not show correctly in corresponding interfaces.
Button/Ports Details
HOME button
Power button
TYPE-C port
USB 2.0 port
SD card port
RJ45 pot
Alarm output port
1、Press this key to return to the main interface
1、To power on and power off the device, hold down the
Powerbutton for a few seconds.
1、 Support 2-way optocoupler open-drain alarm output
1、It can charge the internal rechargeable lithium battery.
1、To transfer the internal data to the U disk. The format
of transfer file is CSV.
2、The main board can be upgraded through U disk.
1、 Internal data can be transferred to SD card.
2、 The main board can be upgraded through SD card.
1、 The device can be used as a web server and the properties can
be read and configured through the web page.
2、 The device can be used as a web server and the real-time data
can be viewed through the web page.
3、 The device can be used as FTP server and the historical data file
can be downloaded through the web page.
4、 The device can be used as FTP server and the main board can
be upgraded through web page.
2、It can supply power to the outside of the equipment to make
the equipment work normally. When the external power adapter
is connected, the power supply of the equipment will come from
the external power supply without consuming battery power.
4
S1500 Series
1
1 2 3 4
5
7
6
Power on →channel configuration
record complete
(stop recording)
→
→
→
configuration complete
enter the digital/bar-chart/real-time curve interfaces to view data information
→start recording
export data to U disk or SD card in the data storage interface (view
historical data in the historical curve interface). Please refer to the
detailed description of each interface for detailed usage guideline.

1.8 Technical Specifications
1.8.1 Technical Specifications
Main parameters
Dimensions
Display
Number of channels
Storage capacity
Internal storage
External transfer
Ethernet
Bluetooth
Battery capacity
Battery life
Sampling frequency
Recording frequency
Data format
Working temperature
Storage temperature
Relative temperature
Shell material
WIFI
189.3*103.5*36.5mm(With ProtectionWith protective sleeve)
5 inch capacitive touch screen, resolution 800 * 480
8-channel/12-channel/16-channel universal input
Support U disk (USB 2.0), SD card (32G)
Transmission rate: 10m / 100M bit / s , full duplex and half duplex
2.4G (Optional)
BT3.0 and BLE4.2 (optional)
5000mAh
One quick charge per day, 3-5 years life time
1s at fast
1s at fast
CSV file format
-10-50℃
-20-60℃
5% - 95% RH, no condensation
PC / ABS material and TPE environmental material are used
for protective sleeve
32GB
A single record file can record up to 100,000 records, and the total
data storage capacity is at least 8,000,000 records
5
S1500 Series
1

1.8.2.Input Signal
Thermocouple input (cold jucntion compensation-cjc excluded), accuracy
(cold jucntion compensation-cjc excluded), CJC error: ± 1.5 ℃
6
S1500 Series
1
Thermistor input
Two-wiresystem
Three-wiresystem
Four-wiresystem
-200-850℃ 0.01 ±1.0
±0.5
±0.5℃
±0.5℃
±0.5℃
±0.5℃
±0.5℃
±2℃
±2℃
±2℃
425℃以下±4.5℃,
425-2320℃ 1.0%
±0.1
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
0.01
-200-850℃
-200-850℃
-270-1370℃
-50-1760℃
-50-1760℃
-200-760℃
-270-980℃
-270-400℃
-270-1300℃
50-1820℃
0-2320℃
NTC-10K -25-150℃ 0.01 ±0.50%FS
±0.50%FS
0.01
-25-150℃NTC-2252
K
J
E
T
R
S
N
B
C
Thermocouple input (excluding cold junction error), accuracy does not include cold
junction compensation error, cold junction compensation error: ±1.5℃
Type Measuring range(℃) Resolution(℃) Maximum allowable
error(℃)
Type Measuring range(℃) Resolution(℃) Maximum allowable
error(℃)

1. The system time cannot be changed during recording.
2. After the data is transferred, the internal stored data will not be deleted
automatically and needs to be deleted manually.
3. Please turn off the equipment when it is not used for a long time.
4. When the power is lower than 10%.
5.After the device is turned off, the user needs to wait for 3S to turn it on again.
6. Do not block the cooling hole when using, so as not to affect the
performance of the equipment.
7. Do not directly clean the equipment with water to prevent water droplets from
entering the equipment and causing damage to the equipment.
8. When connecting the signal wire, please connect it according to the wiring
diagram, and pay attention to distinguish the positive and negative poles.
9. When the internal storage prompt is insufficient, please clean up the internal
storage data in time. If the storage is full, the first recorded data will be
overwritten by the later recorded data.
10. Do not cover the cold end compensation hole when in use (especially when
holding, do not cover the cold end compensation hole with your fingers),
otherwise the accuracy of measurement data will be affected.
Section 2. Attentions
7
S1500 Series
2
DC current / voltage input
Frequency and Pulse input
Max permissible errors(%FS)
Type
(1-5)V
(0-10)V
(0-5)V
(0-100)mV
(4-20)mA
(0-20)mA
(0-10)mA
±0.1%
0.001V
0.001mV
0.001mA ±0.1%
Frequency 0~99KHz ±2Hz
0-4,000,000,000 Pulses
Pulse/Count
Type Measuring range Max permissible errors
Resolution
精度

3.1 Connection Mode
The following picture shows the input port of the thermocouple,wiring method is
shown in the interface diagram
Section 3 Thermocouple input port
8
S1500 Series
3
RTD input(Two-wiresystem) RTD input(Three-wiresystem)
RTD input(Four-wiresystem) Thermocouple input
DC voltage input DC current input
Thermistor input Frequency/ Pulse input

4.1 Menu Bar
Section 4 Interface and function description
9
(1) Device Name:
User defined, 24 characters, LOGGER by default.
(2) Recording status indicator
Standby: gray;
Recording / auto stop: green flashing;
Delay recording: yellow flashing.
(3)Alarm prompt:
This icon appears when there is alarm information; when the device is
normal or enters the alarm interface.
After viewing the alarm information, the alarm prompt icon disappears.
(4)U disk prompt:
The icon will be displayed after the U disk is inserted and successfully identi-
fied. The icon will disappear after the U disk is pulled out.
(5)SD card prompt:
After the SD card is inserted and successfully identified, the icon will be
displayed. After the SD card is pulled out, the icon will disappear.
(6)Storage status prompt:
When the percentage of internal storage reaches 90%, the storage icon
becomes yellow. The percentage reaches 100%, the icon becomes red. The
icon does not display unless the percentage of storage >90%.
(7)Bluetooth function prompt:
When BLE is connected, the icon will be displayed. When BLE is disconnect-
ed, the symbol will disappear.
(8)WiFi prompt:
When the WiFi function is on, the signal strength will be displayed at the
same time; When the WiFi function is off, it will not be displayed.
(9)Power prompt:
The current battery power is displayed in real time. The symbol is green
when normal; yellow when the power is less than 20% and more than 10%,
to remind the user to charge; red when the power is less than 10%, and there
is a charging symbol when charging.
(10)System time indication:
In the format of hour and minute. Seconds are prompted by colon flashing.
S1500 Series
4

4.2 Main interface
4.3 Digital Display
Click digital display in the main interface to enter the digital display interface. The
digital display interface has three arrangement modes: 2 * 4 (4 rows and 2 col-
umns), 3 * 4 (4 rows and 3 columns) and 4 * 4 (4 rows and 4 columns). The
arrangement mode is automatically switched according to the number of chan-
nels of the device.
The digital display interface displays the channel number (ch1 ~ ch16), corre-
sponding value (up to 6 digits), unit (mV、V、mA、℃), alarm status (HH, HI, LO,
LL). Overrun alarm, font display with red mark. HI, LO alarm status display in red,
no flash, HH, LL alarm status red flash.
Click the corresponding channel to view the detailed information of the channel.
The detailed information of the instrument panel includes the upper and lower
limits of the range, the real-time value, the unit and the channel number. The
information on the right side of the instrument panel includes the channel type,
the upper and lower limits of the range, the maximum value, the minimum value,
the average value and the corresponding value of each alarm type. Click "scale"
to clear the value, and click the arrow icon in the upper left corner to return to the
digital display interface.
The main interface displays 8 function icons: digital display, bar chart screen,
real-time curve, historical curve, start / stop recording, data storage, channel
setting and system setting.
10
S1500 Series
4

4.4 Bar Chart Screen
Click the bar graph screen in the main interface to enter the bar graph display
interface. The bar graph display interface has two arrangement modes: 1 * 8 and
1 * 6. The arrangement mode is automatically switched according to the number
of channels of the equipment.
The channel number (ch1 ~ ch16), real-time value, unit, upper and lower limits of
signal and alarm status of analog input are displayed. When the value is normal,
it will be blue, and when the value exceeds the limit, it will be red.
When there are two pages displayed, there are two small circles at the bottom,
and the small circle filled represents the current page. Click the arrow on the
right side of the interface to turn the page.
Bar chart screen
11
Digital display
S1500 Series
4

4.5 Real Time Curve
As shown in the figure below, from left to right at the top of the interface are: unit
selection, channel selection, start / pause icon. The bottom is the channel number
and the latest real-time value. The color of the channel number is the same as that
of the corresponding channel curve, and the bottom channel unit is corresponding
to the left and right ordinates.
Unit selection:
click the type selection drop-down arrow to open the type selec-
tion interface. Click the box in front of the type to check the type to be displayed,
and then click apply. At most, two different type can be checked to display at the
same time.
Channel selection:
click the channel selection drop-down arrow to open the
channel selection interface. Click the box in front of the channel to check the chan-
nel to be displayed, and then click apply. You can only check 6 corresponding
channels at most.
Start / pause:
click the start / pause icon. At the beginning, the real-time curve
will be updated in real time. When pausing, the real-time curve will stop on the
current page and will not be updated.
12
S1500 Series
4
Real Time Curve
Unit switching
Channel switching

4.6 Historical Curve
As shown in the figure below, from left to right at the top of the interface are: record file selec-
tion, unit selection, channel selection; channel number and maximum / minimum value are
displayed at the bottom (click the channel box to switch the maximum and minimum values),
the digits’ color of channel in box is consistent with the curve’s color of corresponding channel,
and the unit at the bottom is consistent with the left and right ordinate unit.
Click the right arrow in the upper right corner to set the start and end time of data query, click
the refresh symbol to refresh the data, and click search to search the historical data.
The mode of unit and channel selection is the same as that of real-time curve.
File selection is shown in the figure below, slide up and down the right slider to view the file,
click the file you want to select, and then click apply.
Time selection is shown in the figure below. Click the up and down arrows to set the time. Click
apply to confirm the set time.
13
S1500 Series
4
Historical Curve

4.7 Start / stop recording
Start recording
stop recording
After setting the corresponding information, click apply to start recording, click Cancel to
cancel the operation, and then return to the main interface.
After starting recording, if return to the main interface, the start recording icon will becomes the
stop recording icon. Click the stop recording icon to pop up the stop recording pop-up window.
Set record
(1) Record file name: customizable, up to 24 bytes. The default is Log1, log2 .
(2) Record interval: customizable, the shortest is 1 second, the longest is 86400 seconds (24h),
only integer can be input.
(3) Delayed start: click the on / off icon to turn on / off the delayed start. The delayed start time
can be set when it is turned on.
(4) Auto stop: click the on / off icon to turn on / off auto stop. When it is turned on, you can set
the time of auto stop.
14
S1500 Series
4

4.8.1 Record documents
4.8.2 Operation log
4.8.3 Alarm log
4.8 Data Storage
Click the box in front of the file to check the corresponding file. Click
the top box to check all the files on the current page.Record the
corresponding information at the bottom of the file interface
(1) Local: select local data
(2) SD card: select the data of the SD card
(3) Page forward
(4) Current page number: Click to enter the page number you want to jump to.
(5) Total number of pages
(6) Page backward
(7) Transfer (Export): Click this icon, the transfer method (USB, SD card)
will pop upClick the pop-up window and select the corresponding method.
(8) Delete: Click Delete, a confirmation pop-up window will pop up to confirm whether you want to delete.
Information at the bottom of the operation log interface:
(1) Page forward
(2) Current page number: Click to enter the page number you want
to jump to.
(3) Total pages
(4) Page back
(5) Transfer (export): click this icon to export the records of all historical
operationlogs to U disk or SD card in CSV format. The transfer mode
(USB, SD card) pop-up window will pop up. Select the corresponding mode.
Information at the bottom of the alarm log port:
(1) Page forward
(2) Current page number: Click to enter the page number you want to
jump to.
(3) Total pages
(4) Page back
(5) Transfer (export): click this icon to save all the historical alarm days
When the log file is exported to U disk or SD card in CSV file format,
it will pop up
15
S1500 Series
4
文件导出
文件删除

4.9.1 Channel setting
4.9 Channel Setting
16
The numbers on the left side of the channel setting ports are CH1 ~ CH16, Channel disabled / channel
not configured: Ring gray; Channel configured successfully: Ring Blue; Currently selected channel:
Green filling.
The icon on the top of the interface is signal type, which indicates from left to right: Disabled (the
channel is not used), RTD (PT100), TC (thermocouple), DC voltage, DC current, thermistor, pulse (only
used on channel 1).
The four icons at the bottom of the interface from left to right are: alarm, calibration, update and
synchronization.
In channel settings, after clicking synchronize all, you must click the update button. If you need to exit
the channel setting, exit after about 1s after clicking the update button.
Steps: click the corresponding channel → select the corresponding signal type → set the signal mea-
surement type → set alarm and calibration (this item is set according to personal needs) → click
Update (complete the channel configuration, if you want all channels to be the same, click sync all,
and then click Update to set successfully).
Note: the pulse / frequency signal is only available on channel 1.
Note: ① pulse / frequency signal is only available in channel 1.
② Only odd channel can set PT100 three wire and PT100 four wire channel modes. When the channel
is set to PT100 three wire or PT100 four wire, the adjacent even channel will be occupied, and the
channel connector will appear between the two channels. If it is changed to other modes, the chan-
nel connector will disappear.
S1500 Series
4
Other manuals for S1500 Series
1
This manual suits for next models
6
Table of contents
Other Huato Data Logger manuals

Huato
Huato S400W Series User manual

Huato
Huato S300-E User manual

Huato
Huato S500 Series User manual

Huato
Huato S100 Series User manual

Huato
Huato S220-T8 Series User manual

Huato
Huato S500 Series User manual

Huato
Huato S1500 Series Quick start guide

Huato
Huato HE173 User manual

Huato
Huato HE17 Series User manual