Hubbell GAI-TRONICS TempSense TS200 User manual

Pub. 42004-566A
G A I - T R O N I C S ®
A H U B B E L L C O M P A N Y
TempSense Models TS200/TS200W
TA B L E O F CO N T E N T S
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 ◼800-492-1212 ◼Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Confidentiality Notice.....................................................................................................................1
General Information.......................................................................................................................1
Installation ......................................................................................................................................2
Camera Location.....................................................................................................................................2
Wall Mount...........................................................................................................................................3
Pole Mount............................................................................................................................................3
VESA Mount ........................................................................................................................................3
Stand Mount..........................................................................................................................................4
Connection...............................................................................................................................................4
Model TS200 ........................................................................................................................................ 4
Model TS200W.....................................................................................................................................4
Configuration..................................................................................................................................5
TempSense TS200...................................................................................................................................5
TempSense TS200W...............................................................................................................................5
Calibration...............................................................................................................................................7
Operation.........................................................................................................................................8
Environment............................................................................................................................................8
Subject Preparation................................................................................................................................8
Scanning Subjects...................................................................................................................................8
Specifications ..................................................................................................................................9
Electrical..................................................................................................................................................9
Mechanical...............................................................................................................................................9
FLIR Camera..........................................................................................................................................9

Pub. 42004-566A
GAI-TRONICS®
A HUBBELL COMPANY
TempSense Models TS200/TS200W
GAI-TRONICS 3030 KUTZTOWN RD. READING, PA 19605 USA
610-777-1374 800-492-1212 Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Confidentiality Notice
This installation and operation manual contains sensitive business and technical information that is
confidential and proprietary to GAI-Tronics. GAI-Tronics retains all intellectual property and other rights
in or to the information contained herein, and such information may only be used in connection with the
operation of your GAI-Tronics product or system. This manual may not be disclosed in any form, in
whole or in part, directly or indirectly, to any third party.
General Information
The TempSense Models TS200/TS200W measure and capture EBT (elevated body temperature) or EST
(elevated skin temperature) of subjects moving through the TempSense’s FOV (field of view). The
TempSense module consists of one FLIR® (forward looking infra-red) camera and one standard video
camera sharing the same FOV in a wall, pole, tripod, or microphone stand mountable enclosure. The
TS200/TS200W captures 608 × 464 resolution images on both cameras and sends them via email to the
an email recipient when the highest temperature in the FOV is above the configurable threshold
temperature.
Figure 1. TempSense Models TS200/TS200W

Pub. 42004-566A
TempSense Models TS200/TS200W Page 2 of 9
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx
03/21
Installation
NOTE:The accuracy of the TempSense TS200/TS200W requires individual subjects pass within two to
six feet of the thermal imaging camera lens. Results with different camera positions may vary.
Thermal imaging camera accuracy improves as the subject moves closer to the camera.
Camera Location
Locate the TempSense TS200/TS200W so that people in a queue individually pass through the two
cameras’ shared FOV while facing the cameras. Each subject scanned should come within two to six feet
of the cameras. The ideal height for camera installation is 5 feet 5 inches above the floor. Installation at a
higher location requires aiming the TS200/TS200W downward so that each subject’s forehead passes
through the center of the FOV (see Figure 2 and Figure 3).
Figure 2. SAMPLE FIGURE Camera Positioning (Side View)
Figure 3. SAMPLE FIGURE Camera Positioning (Top View)

Pub. 42004-566A
TempSense Models TS200/TS200W Page 3 of 9
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx
03/21
Wall Mount
Mount the TempSense TS200/TS200W to a
wall as follows (see Figure 4):
N
OTE
: GAI-Tronics recommends spacing
the TempSense Model TS200
approximately ¼ inch from any flat
surface to allow air flow.
1. Secure the mounting plate (TS200: see
Figure 6, TS200W: see Figure 7) to a flat
surface using (customer supplied)
hardware.
Use the four VESA mount holes to
secure the mounting plate to the wall.
No. 8 screws fit through the 0.190-inch
threaded VESA mounting holes (see
Figure 4).
2. Secure the TS200/TS200W to the
mounting plate using the four included
#6-32 screws.
Pole Mount
Mount the TempSense TS200/TS200W to a
pole (see Figure 5) as follows:
1. Secure the TS200 (see Figure 6) or
TS200W (see Figure 7) mounting plate,
to a pole using (customer supplied)
worm-drive clamps
2. Secure the TS200/TS200W to the
mounting plate using the four included
#6-32 screws.
VESA Mount
Attach a VESA (video electronics standards
association) mount to the mounting plate
with the included #10-24 screws and
washers (TS200: see Figure 6, TS200W: see
Figure 7).
N
OTE
: The TS200/TS200W includes four
#10-24 × 0.38-inch long screws to
attach a customer supplied VESA
mount. Do not use any screws
other than the included #10-24
screws to attach the VESA mount
to the TS200/TS200W’s mounting
plate.
Figure 4. Wall-Mount Detail
Figure 5. Pole-Mount Detail
Figure 6. Mounting Plate Detail (Model TS200)

Pub. 42004-566A
TempSense Models TS200/TS200W Page 4 of 9
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx
03/21
Stand Mount
Mount the TS200/TS200W to a tripod or
microphone stand using the included L-
bracket (see Figure 8).
1. Secure the mounting plate (TS200: see
Figure 6, TS200W: see Figure 7) to the
TS200/TS200W using the four
included #6-32 screws.
2. Secure the L-bracket to the mounting
plate using the two included #8-32 flat
head machine screws (see Figure 9).
3. Secure the L-bracket to a microphone
stand or tripod (see Figure 8).
Connection
Model TS200
Plug a Category 5e or better Ethernet cable
with RJ45 plug from a PoE switch port into
the TS200’s Ethernet jack pigtail. The
TS200's IR sensor has a white LED that
blinks slowly for 40 seconds, then changes
to a fast blink.
NOTE: If the IR sensor LED does not
flash, press the sensor into its
socket using a soft cloth, then
reboot the device.
The Model TS200 boots up and is ready for
configuration (see the Configuration
section) or scanning subjects (see the
Operation section) after adjusting to its
environment (about 10–30 minutes).
Model TS200W
1. Plug the included power supply into the
power cord pigtail on the TS200W.
2. Plug the power supply into a 120 V ac
outlet.
The TS200W's IR sensor has a white LED that blinks slowly for 40 seconds, then changes to a fast blink.
NOTE: If the IR sensor LED does not flash, press the sensor into its socket using a soft cloth, then reboot
the device.
The Model TS200W boots up and is ready for configuration (see the Configuration section) or scanning
subjects (see the Operation section) after adjusting to its environment (about 10–30 minutes).
Figure 7. Mounting Plate Detail (Model TS200W)
Figure 8. TS200/TS200W L-Bracket Detail
Figure 9. L-Bracket Attachment for Tripod/Microphone
Stand Mounting

Pub. 42004-566A
TempSense Models TS200/TS200W Page 5 of 9
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx
03/21
Configuration
The TempSense TS200 and TS200W have a built in webserver for configuration and calibration of the
TempSense device.
TempSense TS200
Configure the TempSense TS200 before calibrating it or using it to scan subjects:
1. Plug a Category 5e or better Ethernet cable with RJ45 plug from a PoE switch port into the TS200’s
Ethernet jack pigtail.
The TempSense TS200 boots up with a static, class CIP address, set to 192.168.1.55.
2. Wait several minutes for the unit to boot and come up to normal operating temperature.
3. Configure a PC to access the TempSense device on the class Cnetwork 192.168.1.x.
4. Open a web browser and enter 192.168.1.55 in the address bar.
The TempSense management webpage contains sections of parameters for defaults (see Table 1),
network (see Table 2), SMTP (see Table 3) , and time (see Table 4).
5. Configure all settings and click APPLY CHANGES AND RESTART.
The unit reboots with the configured settings.
NOTE:If the network mode is DHCP but no DHCP server exists, the unit falls back to IP address
192.168.1.55.
TempSense TS200W
Configure the TempSense TS200W before calibrating it or using it to scan subjects as follows:
1. Plug the included power supply into the TS200W’s power cord pigtail.
2. Plug the power supply into a 120 V ac outlet.
3. Wait several minutes for unit to boot and come up to normal
operating temperature.
The TS200W boots up and creates a wireless network with
following properties:
•WiFi frequency: 2.4 GHz
•SSID: ThermalScanner
•IP address: 192.168.4.1
•subnet mask: 255.255.255.0
•password: GAItronics
4. Use a PC to access the ThermalScanner WiFi access point.
Password: GAItronics
5. Open a web browser and enter 192.168.4.1 in the address bar to
access and authenticate to the TS200W’s management webpage.
The TempSense management webpage contains sections of
parameters for defaults (see Table 1), network (see Table 2),
SMTP (see Table 3) , and time (see Table 4)
Figure 10. Model TS200W
Factory Reset

Pub. 42004-566A
TempSense Models TS200/TS200W Page 6 of 9
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx
03/21
6. Configure all settings and click APPLY CHANGES AND RESTART.
The unit reboots and tries to connect to the configured wireless network.
FACTORY RESET:To reset the TS200W, use a jumper cap to short pins 39-40 on the 40-pin header
for 5 seconds. The TempSense resets itself to factory original settings, reboots,
and re-broadcasts as an access point with the original WiFi properties (see Figure
10).
NOTE:If the network mode is DHCP but no DHCP server exists, the unit falls back to IP address
192.168.1.55.
Table 1. Default Parameters
Parameter
Description
Value:
Description
The TempSense device description.
[MODEL]-[Last Three
Octets of MAC ADDRESS]
degreesf
Select Yes to display the temperature in Fahrenheit or
No to display the temperature in Celsius.
Yes | No
automatic_scan_timeout
The period before scanning restarts after the
measured temperature drops below the threshold
temperature.
0–100, 5(seconds)
Offset
The value to add to or subtract from the temperature
measured by the TempSense
−10 to +10 °F, 0 °F
−6 to +6 °C, 0°C
Threshold
The measured temperature that triggers the
TempSense event.
+60 to +120 °F
+16 to + 48 °C
Model
The factory configured TempSense model number.
TS200 | TS200W
Table 2. Network Parameters
Parameter
Description
Value:
ssid_hidden
Set to Yes if connecting to a wifi network that dos not
broadcast its SSID. Set to No if connecting to a wifi
network that broadcasts its SSID.
Yes | No
ip_addr
IP version 4 address of the TempSense
TS200: 192.168.1.55
TS200W: 192.168.4.1 wifi
ssid
The system set identifier for the wireless network
Case sensitive string
ThermalScanner
ssid_pass
The password for the SSID the TS200/TS200W will
connect to.
GAItronics
nw_mask
IP version 4 network mask
255.255.255.0
nw_gateway
IP version 4 address of the network router
0.0.0.0
dns_addr
IP version 4 address for a DNS server
0.0.0.0
hostname
The common name for this device on the network.
[MODEL]-[Last Three
Octets of MAC ADDRESS]
ip_addr_mode
Static or DHCP
static

Pub. 42004-566A
TempSense Models TS200/TS200W Page 7 of 9
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx
03/21
Table 3. SMTP Parameters
Parameter
Description
Value:
username
The username for the SMTP server mailbox
(string) None
server
the SMTP server’s IP Version 4 address
valid IPv4 address or FQDN
(Fully Qualified Domain Name)
0.0.0.0
security
SMTP security protocol in use
TLS, SSL, None
password
the SMTP password for the mail account
(string)
recipient
The receiver’s email address this TempSense device
sends email to.
valid SMTP email address
None
port
The I/O memory address of the SMTP service on the
host computer
0–65535, 587
Table 4. NTP Parameters
Parameter
Description
Value:
time_server
IP version 4 address for an NTP server
valid IPv4 address or FQDN
(string) 0.0.0.0
time_zone
The offset from UTC
Select the offset from UTC using
the roll box control.
Calibration
1. Place an object of known temperature in the field of view of the TS200/TS200W at the appropriate
height and distance (see the Camera Location section).
2. Login to the webserver and press the CALIBRATE THRESHOLD AND OFFSET button.
3. While watching the temperature of the object in the IR video feed (left side), slide the OFFSET slider
to adjust the on-screen temperature until it displays the known temperature (see Figure 11).
4. Adjust the TEMP THRESHOLD to the desired temperature for the TS200/TS200W to send an email to
the recipient to alert them when a subject exceeds this temperature.
The TS200/TS200W captures both an IR and normal picture when the temperature exceeds the TEMP
THRESHOLD value. It then waits the automatic_scan_timeout period after the temperature drops
below the threshold temperature before scanning resumes.

Pub. 42004-566A
TempSense Models TS200/TS200W Page 8 of 9
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx
03/21
Figure 11. Temperature Superposition and Calibration
Operation
Environment
Environmental considerations for the Models TS200/TS200W NCIT (non-contact infra-red thermometer)
performance:
•Use the temperature scanning feature of the TS200/TS200W in a draft-free space that is out of direct
sunlight and away from radiant heat sources.
•The optimal environment for the TS200/TS200W temperature sensor is between 60.8–104 ºF (16–40
ºC) with the relative humidity below 85 percent.
•Allow the TS200/TS200W to operate in the testing environment for 10–30 minutes to adjust to its
environment before scanning personnel.
Subject Preparation
To obtain accurate skin temperatures, ensure that the subject has not:
•been wearing a hat, scarf, heavy clothing, etc.
•underwent recent physical exertion
•just entered from a much lower temperature environment
•recently used facial cleaning products
•engaged in any other act that may affect their skin temperature.
Scanning Subjects
When a subject with a temperature exceeding the configured threshold enters the IR camera's FOV:
•The TempSense TS200/TS200W sends an email to the SMTP recipient containing still images of the
IR and standard camera's FOV.
•The TS200/TS200W image includes the temperature ±Offset superimposed in the IR picture.

Pub. 42004-566A
TempSense Models TS200/TS200W Page 9 of 9
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-566A.docx
03/21
Specifications
Electrical
Power:
TS200 .................................................................................................................................................PoE
TS200W......................................................................................................................................120 V ac
Mechanical
Dimensions .............................................................7.26 H × 5.76 W × 1.5 D in (184.4 × 146.3 × 38.1 mm)
Weight...................................................................................................................................... 2.0 lb (0.9 kg)
FLIR Camera
Horizontal FOV .........................................................................................................................................51°
Vertical FOV.........................................................................................................................................38.25°
This manual suits for next models
1
Table of contents
Other Hubbell Temperature Controllers manuals
Popular Temperature Controllers manuals by other brands

Oregon Scientific
Oregon Scientific EW99 user manual

esera
esera 11148 quick guide

S+S Regeltechnik
S+S Regeltechnik THERMASGARD RGTF 2 Series Operating Instructions, Mounting & Installation

DAVIS
DAVIS 6832 user manual

Aidcall
Aidcall Tynetec FM0460 quick start guide

esera automation
esera automation PRO 11148 user guide

Bergstrom
Bergstrom NITE Plus Install manual

Honeywell
Honeywell Evohome installation guide

Finglai
Finglai XMT*-JK408 Series instruction manual

GE
GE GE-VCPL Series instruction manual

Sorel
Sorel LTDC Installation and operating instructions

PCB Piezotronics
PCB Piezotronics IMI SENSORS TO642A31 Installation and operating manual