3.3 ELECTRICAL CONNECTION
3.3.1 HY-CLOR pumps are suitable for connection to a nominal 220-240VAC 50hz power supply.
3.3.2 The motor is equipped with a exible cable and 3-pin plug. If a power outlet is not available within
2 metres of the pump, a 3-pin power point in a safe dry place will need to be provided
by an electrician.
3.3.3 The pump power must be supplied through a residual current device (RCD) having a rated residual
operating current not exceeding 30mA.
3.3.4 Extension cords are unsafe around pools and must be avoided
4.0 OPERATION
4.1 GENERAL START UP GUIDE
4.1.1 CAUTION: Never run the pump without water. Running the pump “dry“ for any length of time can
cause severe damage to both the pump and the motor and will void the warranty.
4.1.2 If it is a new pool installation, make sure all piping is clear of construction debris and has been
properly pressure tested. Special care must be taken to ensure no small pebbles are ingested into
the pump as this voids the warranty.
4.1.3 The lter should be checked for proper installation, verifying that all connections are secure
according to the manufacturer’s recommendations.
4.1.4 Depending on the location of the pump, do one of the following:
a) If the pump is located below the water level of the pool, open the lter pressure valve to prime
the pump with water.
b) If the pump is located above the water level of the pool, remove the lid and ll the basket with
water before starting the pump.
4.1.5 Prior to replacing the lid, check for debris around the lid o-ring seat. Debris around the lid o-ring
seat will make it difcult to prime the pump and may damage the o-ring.
4.1.6 Hand-tighten the lid to make an air tight seal (do not use any tools to tighten as damage may
occur).
4.1.7 Make sure all valves are open and the unions are tight. Turn on the pump, the pump will take a
short time to prime and then deliver at full rate. No further priming should be required.
4.1.8 If prime is not established within approximately two minutes (as evidenced by a strong ow of water
from the outlet) switch off the pump and repeat the procedure above (5.1.4 through 5.1.7).
4.1.9 If bubbles persist under the lid there is a leak in the suction connections or the lid is not sealed
properly, switch off the pump and repeat the procedure above (5.1.5 through 5.1.7).