HydroQuip CS6000 YE-5 Series User manual

CS/ES6000 YE-5 SERIES
Operation Manual
Y SERIES
GECKO
TM
By
SLIDE SERIES-LOW-FLOW
FIXED SERIES-HIGH FLOW
SLIDE SERIES-HIGH FLOW

-U Series "Universal Fixed" Heater configuration: This series is
designed to fit the most common heater position. Depending upon the
actual control being replaced, you may still need to modify the plumbing
to achieve proper alignment.
This manual covers electrical and installation details on the following
product series. Some photos and instructions may not apply to the
product you have purchased.
-US Series "Universal Slide" Heater configuration: This series is
designed to allow the heater to be positioned within 20" of the control to
provide an installation with a minimum of plumbing modifications.
Depending upon the actual control being replaced, you may still need to
modify the plumbing to achieve proper alignment.
-VH Series "Versi-Heat" Heater configuration: This series is designed
to allow the heater to be positioned within 60" of the control to provide an
installation where there may not be enough room in the immediate
equipment area and to minimize plumbing modifications. Depending
upon the actual control being replaced, you may still need to modify the
plumbing to achieve proper alignment.
-LH Series "Less Heater" configuration: This series allows the use of
customer supplied custom heater configurations which may not have
been available from Hydro-Quip. Please refer to the "LH" wiring diagram
enclosed with the "LH" wiring harness for specific wiring connections and
details NOT covered within this manual.
-3W Series "3-Wire 240V Ready": This series allows the use of 3-wire
(2 x Hots & Ground) 240V electrical service.
-LF Series "Low Flow" configuration: This series includes a “Low-
Flow” heater for used with a wide variety of circulation pumps.
Introduction

Important Safety Instructions................................3-4
Circuit Board Configurations...................................9
Electrical Installation.............................................5-7
Pump Cord Connections.........................................9
Flow Switch & Heater Connection.........................10
Low-Level Set-Up Codes......................................12
Spaside Control Installation..................................13
Breaker & Low-Level Set-Up Codes......................11
System Start-Up....................................................14
Power Connection...................................................8
Operational Considerations...................................27
Data Label & Warranty..........................................30
Troubleshooting................................................28-29
WiFi Module Option Installation.............................26
Programming Options (K200 Keypad).............18-19
Cord Configurations...............................................25
Programming Options (K450 Keypad)..............20-22
Programming Options (K8 Keypad).................15-17
Spaside Messages...........................................23-24
Table of Contents

3
IMPORTANT SAFETY INSTRUCTIONS
DANGER To reduce the risk of injury, do not permit children to use this product
unless they are closely supervised at all times.
WARNING - RISK OF CHILD DROWNING. Extreme caution must be exercised to
prevent unauthorized access by children. To avoid accidents, ensure that children
cannot use a spa or hot tub unless they are supervised at all times.
DANGER To reduce the risk of injury to persons, do not remove suction fittings.
Spa location must accommodate sufficient drainage of water around the base of the
structure, as well as the power source compartment.
Prolonged immersion in water that is warmer than normal body temperature can result
in a dangerous condition known as HYPERTHERMIA. The causes, symptoms,
and effects of hyperthermia may be described as follows: Hyperthermia occurs
when the internal temperature of the body reaches a level several degrees above
the normal body temperature of 98.6BF. The symptoms of hyperthermia include
dizziness, fainting, drowsiness, lethargy, and an increase in the internal
temperature of the body. The effects of hyperthermia include (1) unawareness of
impending hazard, (2) failure to perceive heat, (3) failure to recognize the need to
exit spa, (4) physical inability to exit spa, (5) fetal damage in pregnant women, (6)
unconsciousness resulting in danger of drowning. WARNING The use of alcohol,
drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs
and spas.
DANGER - RISK OF ELECTRICAL SHOCK.
A spa may be installed within 5 feet of metal surfaces if each metal surface is
permanently connected by a solid copper conductor attached to the wire connector
on the terminal box . Refer to NEC and local codes
A bonding lug is provided on the control box to permit connection of a
solid copper bonding conductor between this point and any equipment, metal
enclosures of electrical equipment, metal water pipe, or conduit within 5 feet
(1.5m) of the unit as needed to comply with local requirements.
Bond accessible metal to the dedicated connector on the equipment grounding bus,
bond the equipment ground bus to the local common bonding grid as part of the
installation in the form of (1) a reinforced concrete slab for support, (2) a ground
plate provided beneath the hot tub or spa, or (3) a permanent ground connection
that is acceptable to the local inspection authority.
DANGER RISK OF ELECTRICAL SHOCK. Do not permit any electrical appliance,
such as a light, telephone, radio, or television, within 5 feet (1.5m) of a spa or hot
tub.
To reduce the risk of injury:
The water in a spa or hot tub should never exceed 104°F (40°C). Water temperatures
between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult.
Lower water temperatures are recommended for extended use (exceeding 10-15
minutes) and for young children.
Excessive water temperatures have a high potential for causing fetal damage during
the early months of pregnancy, pregnant or possibly pregnant women should limit
spa or hot tub water temperatures to 100°F(38°C).
!
!
!
!
!
Before entering the spa or hot tub, the user should measure the water temperature
with an accurate thermometer.
The use of alcohol, drugs, or medication before or during spa or hot tub use may lead
to unconsciousness with the possibility of drowning.
Persons suffering from obesity or with a medical history of heart disease, low or high
blood pressure, circulatory system problems, or diabetes should consult a
physician before using a spa or hot tub.
in effect at the time of
installation.)

4
Persons using medication should consult a physician before using a spa or hot tub
since some medication may affect heart rate, blood pressure, and circulation.
A terminal marked “G” or “ground” is provided in the wiring box located inside the
equipment compartment. To reduce the risk of electric shock, connect the
terminal or connector to the grounding terminal of your electrical service or supply
panel with a continuous green insulated copper wire in accordance with National
Electric Code Table 250-95 and any other local codes in effect at the time of the
installation.
The electrical supply for this product must include a suitably rated switch or circuit
breaker to open all ungrounded supply conductors to comply with Section 422-30
of the National Electric Code, ANSI/NFPA 70 1987. The disconnecting means
must be readily accessible to the tub occupant but installed at least 5 feet (1.5m)
from the tub water.
WARNING - Do not install indoors. This unit uses a gas heater that requires proper
ventilation and is intended for outdoor use only.
For Permanently Installed Units
For Permanently Installed Units not Provided with an Internal Disconnecting Method
For Units with Gas Heaters
HIGH VOLTAGE CAN SERIOUSLY INJURE OR KILL!
DO NOT remove the protective covers from any electrical enclosure, or
attempt to service any related electrical device, unless you are a qualified
electrician or service professional.
ONLY EXPERIENCED TECHNICIANS SHOULD SERVICE THIS
EQUIPMENT.
DANGER
Risk of electric shock. Before working with any electrical connections,
make certain that the Main Power breaker from the house breaker box has
been turned off.
WARNING
All electrical work must be performed by a qualified electrician and must
conform to all local codes.
IMPORTANT
Due to the danger of severe electrical shock, locate all power disconnects
before servicing a spa. Precautions must be taken whenever working with
breaker boxes, G.F.C.I.’s, or service disconnects.
High Voltage Warning
Must be connected to a grounded, grounding type receptacle only. NEVER connect
the spa to an extension cord.
Do not bury the cord.
For Cord and Plug Connected Units
IMPORTANT SAFETY INSTRUCTIONS

5
Electrical Installation
15A 20A 30A 40A 50A 60A
12A
16A 24A
32A 40A 48A
14 12 10 86 4
Circuit & Breaker
Rating
Maximum Amps
Minimum Wire
Size
The NEC and most local codes require that a “disconnect” be installed within
“line-of-site” of the spa.
Refer to the System Data Label for equipment voltage and maximum amperage
draws.
The GFCI (Ground Fault Circuit Interrupter) is a mandatory electrical safety device
required for all portable spas and hot tubs as specified in the National Electrical
Code Article 680-42. The GFCI in your particular installation may be installed at the
electrical service panel or a separate sub-panel.
A licensed electrician must accomplish the electrical installation in accordance with
the National Electric Code(NEC) Article 680, and any local codes in effect at the
time of installation.
Use copper conductors ONLY. The ground must be sized following the National
Electric Code, Table 250-122. For Power conductor size, refer to the National
Electric Code Table 310-16.
A bonding lug has been provided on the control box to allow connection to local
ground points. To reduce the risk of electrical shock, a solid copper bonding wire
should be connected from this lug to any metal objects within 5 feet of the spa.
IMPORTANT- If your electrician is not absolutely sure how to connect
your system correctly, call your local dealer. Any mistake may be costly
and void your equipment warranty.
The above table is a wiring chart representation.
CAUTION: Damage may occur to the circuit board and spaside if the spaside
plug is not properly aligned to the receptacle on the circuit board or if the
spaside plug is connected or disconnected while the power is on.
**Any resulting damages are not covered under manufacturer’s warranty**
CAUTION: Do not connect or disconnect any components while the power is on.
All connections must be done with the power off as it may cause damage to the
system.
**Any resulting damages are not covered under manufacturer’s warranty**

6
ELECTRICAL CONNECTIONS
Electrical Installation
MAIN BREAKER PANEL
LINE 1
N
LINE 2
OPTION 1
MAIN BREAKER PANEL
OPTION 2
20-60AMP HARDWIRED
Option 1 shows the power from GFCI breaker installed into main service panel to a
service disconnect within line-of-site of the spa. If the manufacturer of your homes main
breaker panel makes a GFCI breaker, you may be able to add it to an open slot in the
panel.
Option 2 shows the power from main service panel to a GFCI subpanel within line-of-site
of the spa. (Note: Most local codes will allow a GFCI subpanel to be a disconnect. If this
is not the case in your installation, a disconnect must be provided.)
REFER TO GFCI WIRING DETAIL ON PAGE 8
GFCI Installed in Main Service Panel
Subpanel GFCI Installed
PORTABLE SPA
INLINE SPA DISCONNECT
20-60AMP HARDWIRED
GFCI DISCONNECT
LINE 1
N
LINE 2
INLINE SPA DISCONNECT
TO PORTABLE SPA
REFER TO GFCI WIRING DETAIL ON PAGE 8

7
It is important that the GFCI circuit breaker is installed correctly. Often this
component has been improperly installed causing the breaker to instantly trip
when the system is turned on. Below is an illustration of a typical GFCI breaker
installation.
WARNING: Refer to the circuit breaker manufacturers installation
instructions. This illustration is meant to be a guide for Field Technicians
and is not intended to override or substitute the instructions supplied with
the circuit breaker.
GFCI
TEST
(Ground Fault Circuit Interrupter)
CIRCUIT BREAKER
NEUTRAL PIGTAIL
NEUTRAL BUS BAR
LINE 1
NEUTRAL
LINE 2
GROUND
GROUND BUS BAR
LINE LUG #1 LINE LUG #2 INCOMING
SERVICE
CONDUCTORS
FROM
MAIN
PANEL
NEUTRAL
GROUND
TO SPA CONTROL SYSTEM
LOAD
LOAD NEUTRAL MUST BE
CONNECTED
DIRECTLY TO GFCI AS SHOWN**
GFCI Wiring Detail
This illustration depicts a typical 15 AMP, cord-end GFCI installation.
(The spa must be installed on a dedicated circuit.)
If your system was configured to include a 120VAC power cord, ensure that the proper
receptacle has been installed (a dedicated circuit is required). DO NOT under any
circumstances modify a 20 Amp plug to fit into a 15 Amp receptacle or use an extension
cord. Doing so will create hazardous conditions and/or invalidate the warranty.
OPTION 3
15/20AMP CORD END GFCI
15A / 120V OUTLET
PORTABLE SPA
MAIN BREAKER PANEL
DEDICATED
Units with 15A / 20A GFCI Plug Connection
Electrical Installation
LINE 1
LINE 2
**LOAD NEUTRAL NOT REQUIRED
FOR -3W (3 WIRE 240V) SYSTEMS

8
120-VOLT ELECTRICAL SERVICE REQUIREMENTS
240-VOLT ELECTRICAL SERVICE REQUIREMENTS
ŸSecure wires as defined by the NEC and in compliance with any local
codes in effect at the time of installation.
ŸUse copper conductors only as required by the NEC.
IMPORTANT: Always refer to the product data label (located on top of the
control box) for specific electrical information.
IMPORTANT- All equipment must be rated for 120VAC.
*Heater wattage is rated at 240V. When running 120V to heater, output is approximately 25%.
Power Connection
FUSE 30A
N
L1
GR
P17
P18
P19
P6
P2
F1
1
2
3
4
P10
P11
P13 P14
P15
P21
P12
P25
P79 P78
P5 P7
240V
RED
WHITE
BLACK
GREEN
INPUT
VOLTAGE
L1
N
L2
L2
120V
---
WHITE
BLACK
GREEN
INPUT
VOLTAGE
FUSE 30A
N
L1
GR
P17
P18
P19
P6
P2
F1
1
2
3
4
P11
P13 P14
P15
P21
P25
P79 P78
P5 P7
P9
L1
N
---
P10 (120V)
Heater Voltage* (P12) Brown Wire:
Moves to P10 for 120V
Heater Voltage (P12) Brown Wire:
Moves to P9 for 240V (Default)
P9 (240V)
P12
P12
P9
P10
240-VOLT (3-Wire) ELECTRICAL SERVICE REQUIREMENTS
FUSE 30A
L1
GR
P17
P18
P19
P6
P2
F1
1
2
3
4
P10
P11
P13 P14
P15
P21
P12
P25
P79 P78
P5 P7
240V
RED
WHITE
BLACK
GREEN
INPUT
VOLTAGE
L1
L2
L2
Heater Voltage (P12) Brown Wire:
Moves to P9 for 240V (Default)
P9 (240V)
P12
P9
WHT/OPT

9
Black = Hot/Line
White = Common
Green = Ground
Single Speed
Device / Acc
System
Black = High Speed
Red = Low Speed
White = Common
Green = Ground
Pump
System
Circuit Board Configurations
Pump Cord Connections
The following wiring configuration is for two-speed pump circuits.
2-SPEED PUMP CORD CONFIGURATION
The following wiring configuration is for single-speed pump circuits, circulation
pumps, ozone, blowers and accessories.
SINGLE SPEED PUMP / ACCESSORY CORD CONFIGURATION
Component Volts Amps Wire End Color Code From To
P1 2-SPD 240V 12A Red N L2
P2 1 or 2-SPD 240V 12A Violet N L2
Blower 240V 8A Blue N L2
Ozone 240V 1A Yellow N L2
Circ Pump 240V 2A Brown N L2
Voltage Selection Chart for 240V Conversion
-3W: All component outputs are pre-configured for 240V. 120V conversion only possible if
Neutral is available.
Note: Check product data label “Order Code” before proceeding
-U: All component outputs are pre-configured for 120V. If 240V output is required, please
utilize the illustration below and the wiring diagram that was included with your unit for the
correct component location to properly convert to 240V.
N
L2
120V
Neutral Section
240V
L2 Section
P47
G N
L2
P48P49P50P51P52
P53
P56
P57
P58
P59
P60
P61
P62
P67P68P69P70P71P72
P73
P55 P77
K2
K4
K6
Neutral & L2
Sections

10
Pressure/Flow Switch & Temp Sensor Connection
Hardwired Temp/High-Limit Sensor: If not factory connected the installer must connect
the temp/high-limit sensor directly to the circuit board at location P38 / PROBE.
See photo below for actual connector locations on the board.
Hardwired Flow/Pressure Switch: Most Low-Flow configurations are supplied with a flow
or pressure switch that connects directly to the circuit board at location P66 / FL-SW.
The flow or pressure switch connects to the
P66 connection directly. Please note the
connector has (3) pins of which only 2 are
used (1 & 3). The connector on the cord will
have (3) connection points also although
only 2 may be used or jumped. Please
assure connector is centered and all (3)
pins are covered for proper operation.
1 2 3
Heater Inlet/Outlet Ports Heater Power Connection
PSI/FLOW SWITCH
CONNECTION
TEMP/HL SENSOR
CONNECTION

11
System Low-Level Program Settings
If the circuit “A#” is not defined then it is not used.
Using the chart above:
2) Which component circuit/receptacle (A0-A4) is used for each
component based on the chosen configuration.
1) Used for choosing the proper software configuration for the hot tub.
Example for Setup # 11: Pump 1 is 2 SPD and connects to (A3),
Pump 2 is 1 SPD and connects to “A2”, a Blower or Pump 3 may be
connected to “A1”, the “Y” splitter is used to connect the Circulation
pump and Ozone to “A4”.
Circuits:
Leave components disconnected until the software
setup and voltage of components is chosen and
configured.
ŸA0 - A4

12
L __
If at power-up of the system and spaside display shows the following message: , it
means that all low-level configurations have been downloaded, but no configuration
number has been chosen.
Power Up & Breaker Setting
Changing System Low-Level Program Configuration
Although every system has been factory set, in certain cases when servicing or replacing a
unit in the field, it may be necessary to set a new pre-determined low-level program
configuration. Follow these simple steps to re-enter the low-level programming using the
spaside control.
Lamp test Low-level selection
Software number
8.8.8
Boot up display sequence (Each parameter is displayed for 2 seconds) Numbers may vary
Power-up & breaker setting
Software Revision
All the segments and
LEDs light up.
Software Part Number Revision of the Software Low-level selected
from Low-level menu
The values
displayed by the
system
correspond
to
0.8 of
the
maximum
amperage
capacity
of
the
GFCI.
UseUp /
Down
button
to select the
desired value. The value can be
modified typically from10 to 48
AMP.
GFCI b
60
Amp 48
Amp
50
Amp 40
Amp
40Amp 32Amp
30Amp 24
16Amp
98
It'simportant to
specify
the
current rating
of
the
GFCI
usedto ensure
safe and
efficient
current
management
(and
reduce
nuisanceGFCI
trippings).
Press and hold Program button
until you access the breaker
setting menu.
It’s important to specify the current rating of the GFCI used to ensure safe and efficient
current management (and reduce nuisance GFCI trippings).
20Amp
Amp
418 1
NOTE: If all installed components do not operate or only one
component can be operated at a time it may be caused by this
setting. Set breaker size accordingly to allow components to run.
Press and hold the Pump 1
key for 30 seconds
Use
the
Temp Up/Down
key tochoose
the
new
desired low-level
configuration
number
and
press the Program key to confirm the selected configuration (referto
the configuration selectionchart below).
The spaside
display
will
show
L##
where
“##" represents the previous
configuration number registered in the system.
If the Program key is not pressed within 25 seconds, the unit will exit this menu
without changing any settings.
98
Note: DO NOT let off the button
until 30 seconds has passed and
L## is displayed. You will see
other values displayed prior that
are to be ignored during this
programming process.
Then press the Program button to
set the breaker rating. This table
shows typical settings of b for the
different GFCI ratings. Select the on
that matches the supply breaker
OR OR
16
OR

13
Step 4 - Connect spaside to PCB
connection marked C1. (Fig.4)
Fig.4
Spaside Control Installation
Step 1 - Clean area and insert spaside
control. (Fig.1)
Overlay may vary
Step 2 - Remove the double sided adhesive
from the back of the spaside. Make certain
the spaside is straight and adhere to the spa
shell. (Fig.2)
If required, you may have to cut out a hole in the spa shell to install spaside control.
ŸThe mounting area must be above the maximum water level of the spa and in an
area with good drainage to prevent any standing water on or around the spaside.
ŸThe spaside should never be submerged.
ŸThe spaside should be protected from extended periods of exposure to sunlight.
ŸDo not step or stand on the spaside
Now carefully align and apply the label. (Fig.3)
Step 3 - Remove protective film from display
window then clean the face of the spaside.
Fig.3
Fig.1 Fig.2
K6
P45
CO C1CO
P46
P55 P77
MAIN KEYPAD
See steps below for installation
6.375"
161.92 mm
2.625"
67.36 mm
2 5/8 "
66 mm
1"
25,4 mm
1"
25,4 mm
LARGE FORMAT
K5, K8, K19
SMALL FORMAT
K200
Above cutouts are NOT to scale
To install K5, K8 or K19 keypad cut an opening of
2.625” X 6.375” as shown above
ŸTo install K200 keypad drill two 1” (25mm) holes at 2
5/8” from center to center as illustrated above
ŸCut out material between the two holes
6 7/32"
158 mm
Follow profile with jig saw
Drill 2x 3/8
2x 9 mm
2 5/16"
59 mm
MEDIUM FORMAT K450

14
SYSTEM START-UP
Step 2) Install the control panel / keypad per the instructions on Page
#13
Step 3) Install the component cords if required, see Page #9, and the spa
light. DO NOT connect component cords to the system at this time
Step 1) Install the control system into the spa using industry standard
methods and procedures
Step 5) Please reference Page #12 for setup and configuration options.
This page shows the setup number options as well as the corresponding
component output connector used for the chosen setup. Make note of the
setup number and connector(s) to be used. DO NOT connect any pump,
blower, etc cords to the control at this time
Step 6) Before proceeding review the instructions on Page #11 of this
manual as these procedures will be used in the next steps.
Step 7) Turn the power ON to the spa and proceed to the keypad. You
may see error code(s) at this time, please ignore, this is normal operation
until the setup is complete.
Step 4) Connect the main power to the control system per the instructions
on Page #8 and make note of the breaker size - DO NOT TURN ON
THE POWER proceed to Step #5
Step 12) The system initiates first filtration cycle at power up so
depending on the chosen setup number various components may be
starting & running momentarily. At minimum your heater pump should be
running. “---” will be displayed for the first 2-3 minutes while the system
performs start up checks after which the present water temperature will be
displayed.
Step 10) Connect all the components to the system. Pump(s), blower,
ozone, etc.
Step 8) Having determined the breaker size in Step 4 enter the breaker
setting menu, Page #11, to set the breaker value accordingly.
Step 11) Turn the power on to the spa and proceed to the keypad. The
display may be flashing indicating a power interruption and pump(s) may
be running. Press a button to confirm the interruption and stop the display
flashing.
Step 9) Having chosen the setup number in Step #5 follow instructions
lower portion of Page #11 to set the software Setup Number. Once
complete allow system to reboot then turn off the system power.

15
Pump 1 - Press o nce to turn on low speed. Press a second time to turn pump to high
(with a dual-speed pump). A third time turns pump off.
A built-in timer automatically turns pump off after 20 minutes, unless pump has been
manually deactivated fi rst.
The “Pump 1” indicator lights up when Pump 1 is on. With dual-speed pump, indicator
will fl ash when Pump 1 is on at low speed.
speed
Light - Press once to turn light on. Press Light key a second time to turn light off.
A built-in timer automatically turns light off after 2 hours, unless it has been manually deactivated fi rst.
The “Light” indicator lights up when light is on.
Temp Up - Use Up key to raise the temperature Set Point. The temperature setting will
be displayed for 5 seconds to confirm your new selection.
Temp Up - Use Up key to lower the temperature Set Point. The temperature setting will
be displayed for 5 seconds to confirm your new selection.
up when Pump 2 is on High speed and flashes on Low speed.
The “Pump 2” indicator lights
Blower key -Press Blower key to turn blower on. Press Blower Key again to turn
off.
A built-in timer automatically turns blower off after 20 minutes, unless blower has been manually
deactivated fi rst.
The “blower ” indicator lights up
when Blower is on.
The "Set Point" icon indicates that the display shows the
NOT the current water temperature!
desired temperature,
The "Set Point" icon indicates that the display shows the
NOT the current water temperature!
desired temperature,
Programming Options - K8 Keypad
A built-in timer automatically turns off the pump after 20 minutes unless manually
deactivated first.
Pump 2 - Press once to turn pump on press again to turn the pump off. If 2 speed
pump is used first press turns on low speed, second press activates high speed.
Indicator
Pump 1
Pump 2
Indicator
Blwr/Pump
3
Indicator
Indicator
Light
Filtration
Indicator
Indicator
Heater
Pump 1 Pump 2 Blower/Pump 3 Light
Power
Program Temp Up Temp Dwn

16
E = Economy mode active
Manual Economy Mode - Press to toggle Economy mode on or off. When active the
system will maintain a set temperature of 20°F less than set the current set temperature
and the display will toggle between “E ” the clock and the water temperature. Press
the power button again to cancel economy mode. Programmed cycles may also activate
or deactivate Economy mode.
Power Key - This key provides access to:
E = Economy mode not active
Note: Changes will be saved after the confirmation of the last parameter only. If
there is no key press for 10 seconds, the system will exit the program menu
without saving the changes.
PROGRAM/FILTER Key: A quick press of the Filter key will allow you to display the
clock. A long press of 5 seconds will allow you to enter the program menu. In the
program menu, the following parameters can be set: the clock, the filter cycles or the
purge cycles, the economy mode and the temperature units. While you are in the
program menu, use the up or down keys to adjust the parameters and use the Filter key
jump to the next parameter.
Programming Options - K8 Keypad (cont)
* PM indicator
Setting the Clock: Enter the programming menu by pressing and
holding the FILTER key for 5 seconds. The current time will be
displayed with the hours flashing.
Press the UP or DOWN key to adjust the hours accordingly making
sure the PM indicator is set properly.
Press the PROGRAM key to advance to changing the minutes
Press the UP or DOWN key to adjust the hours accordingly making
sure the PM indicator is set properly.
0 = No Filtration
Press the UP or DOWN key to adjust the hours accordingly making
sure the PM indicator is set properly.
24 = Continuous Filtration
Setting the Filter Cycle: Enter the programming menu by pressing
and holding the FILTER key for 5 seconds. The current time will be
displayed with the hours flashing. If adjusting the clock is necessary
do it now, otherwise press the PROGRAM key repeatedly until
FS## is displayed. “FS” represents FILTER START “##”
represents the start time hour.
Press the PROGRAM key to advance to changing the until F ## is
displayed. “F ” represents FILTER DURATION “##” represents
the run time for the filter cycle.
P
P

17
Programming Options - K8 Keypad (cont)
Press the UP or DOWN key to adjust the cycles as required.
Setting the Filter Cycle Frequency: - Enter the programming menu
by pressing and holding the FILTER key for 5 seconds. The current
time will be displayed with the hours flashing. If adjusting the clock is
necessary do it now, otherwise press the PROGRAM key repeatedly
until FF## is displayed. “FF” represents FILTER FREQUENCY
“##” represents the number of cycles per day, 1 - 4 cycles per day.
Press the UP or DOWN key to adjust the setting as required.
1 = On / Cycle Enabled
0 = OFF / Cycle Disabled
Setting the Economy Mode: Enter the programming menu by
pressing and holding the FILTER key for 5 seconds. The current
time will be displayed with the hours flashing. If adjusting the clock is
necessary do it now, otherwise press the PROGRAM key repeatedly
until EP## is displayed. “EP” represents ECONOMY PROGRAM
“##” represents cycle enabled or not
Setting the Economy Start Time: Enter the programming menu by
pressing and holding the FILTER key for 5 seconds. The current
time will be displayed with the hours flashing. If adjusting the clock is
necessary do it now, otherwise press the PROGRAM key repeatedly
until ES## is displayed. “ES” represents ECONOMY START,
“##” represents hour the cycle starts
Press the UP or DOWN key to adjust the setting as required paying
close PM indicator.
Press the UP or DOWN key to adjust the hours as required
Setting the Economy Duration: Enter the programming menu by
pressing and holding the FILTER key for 5 seconds. The current
time will be displayed with the hours flashing. If adjusting the clock is
necessary do it now, otherwise press the PROGRAM key repeatedly
until e ## is displayed. “e ” represents ECONOMY DURATION,
“##” represents the active time in hours.
24 = Continuous Economy
0 = No Economy
PP
Press the UP or DOWN key to adjust as required
C = Celcius
F = Farenheit
Changing the Temperature Readout: Enter the programming menu
by pressing and holding the FILTER key for 5 seconds. The current
time will be displayed with the hours flashing. If adjusting the clock is
necessary do it now, otherwise press the PROGRAM key repeatedly
until F or C is displayed.

18
Smart winter mode
indicator
Pump 1
indicator
Pump 2
indicator
Light
indicator
Filter
indicator
Heater
indicator
Set Point
indicator
Pump 1 Pump 2/Blower Temp Up/Down
Light
Pump 1 - Press o nce to turn on low speed. Press a second time to turn pump to high
(with a dual-speed pump). A third time turns pump off.
A built-in timer automatically turns pump off after 20 minutes, unless pump has been
manually deactivated fi rst.
The “Pump 1” indicator lights up when Pump 1 is on. With dual-speed pump, indicator
will fl ash when Pump 1 is on at low speed.
speed
Light - Press once to turn light on. Press Light key a second time to turn light off.
A built-in timer automatically turns light off after 2 hours, unless it has been manually
deactivated fi rst.
The “Light” indicator lights up when light is on.
The "Set Point" icon indicates that the display shows the desired temperature, NOT the
current water temperature!
Programming Options - K200 Keypad
Pump 2/Blower - Press once to turn pump on press again to turn the pump off. If
2 speed pump is used first press turns on low speed, second press activates high
speed.
A built-in timer automatically turns off the pump after 20 minutes unless manually
deactivated first.
The “Pump 2” indicator lights when Pump 2 is on. With a dual speed pump the
indicator will flash in low speed and be solid in high.
Temp Up/Down - Use this key to raise, lower or display the set temperature.
Press and hold the button to “scroll” the set temperature up or down, release
press-and-hold again to “scroll” the opposite direction. Release button when the
desired set temperature is displayed. When pressed or used the set temperature
will be displayed for 5 seconds then revert to current water temperature.

19
Programming Filtration Cycles & Temperature Readout
Use Up / Down key to change the setting
0 = No filtration
Programming Options - K200 Keypad
24 = Continuous filtration
f
Setting Filter Cycle Frequency
Setting Filter Cycle Duration
To set filter cycles you must enter the following parameters: Duration (d) and Frequency (F). At the
beginning Pump 1 (+ additional components staggered) will run for 1 minute each to purge the
plumbing. Pump 1 will run for the remainder of the cycle unless a button is pressed to suspend the
filter cycle.
Press the Light key again, the display will show
F or C. This is the temperature readout units.
(Default: F)
Press and hold the Light key until the
display shows dxx, with “xx” representing
the duration in hours. (Default: 1 hour).
Press the Light key again, the display will
show Fx with the “x” representing number
(or Frequency) of cycles per day (up to 4).
(Default 2 cycles a day)
Setting Temperature Display Readout
f
ff 2
The first filter cycle begins at power up or each time the settings above are accessed.
The cycle repeats 6, 8, 12, or 24 hours later based on the Frequency setting
1 = One cycle per day (every 24hrs)
3 = Three cycles per day (every 8hrs)
4 = Four cycles per day (every 6hrs)
2 = Two cycles per day (every 12hrs)
F = Fahrenheit
C = Celsius.
The “Filter” indicator blinks when a filter cycle is suspended
The “Filter” indicator lights solid when a filter cycle is active
Off Mode Feature
off
This mode allows you to stop all outputs for 30 minutes to perform a quick spa maintenance.
Press and hold Pump 1 for 5 secs to activate
Off Mode. Quick press Pump 1 to reactivate
the system before the expiration of the 30 minute delay.
While the Off Mode is engaged, the display will
toggle between Off and the water temperature.
Use Up / Down key to change the setting
Use Up / Down key to change the setting
This manual suits for next models
10
Table of contents
Other HydroQuip Heater manuals

HydroQuip
HydroQuip Pure Heat Pressure Series User manual

HydroQuip
HydroQuip Therm Products 27-V310-7T-K User manual

HydroQuip
HydroQuip Therm Products E2550-0300ET User manual

HydroQuip
HydroQuip CS Series User manual

HydroQuip
HydroQuip 8800 BP Series User manual

HydroQuip
HydroQuip BES6000-HC Series User manual
Popular Heater manuals by other brands

TCP Smart
TCP Smart SMABLFAN1500WBHN1903 User instructions

Daikin
Daikin EHXD installation instructions

VTS Euroheat
VTS Euroheat FiGHTER 100EH user manual

Harvia
Harvia PO12-U1 Owner's/operator's manual

Fogo & Chama
Fogo & Chama HEAT-481-SS Operating/safety instructions

BN Thermic
BN Thermic SystemX XR-30 instructions