IBA ibaDeskline SAS User manual

ibaDeskline SAS
iba Industrial Computer
Manual
Issue 1.4

2
Issue 1.4
Manufacturer
iba AG
Koenigswarterstr. 44
90762 Fuerth
Germany
Contacts
Main office +49 911 97282-0
Fax +49 911 97282-33
Support +49 911 97282-14
Engineering +49 911 97282-13
E-Mail: iba@iba-ag.com
Web: www.iba-ag.com
This manual must not be circulated or copied, or its contents utilized and disseminated,
without our express written permission. Any breach or infringement of this provision will
result in liability for damages.
©iba AG 2020, All Rights Reserved
The content of this publication has been checked for compliance with the described hard-
ware and software. Nevertheless, deviations cannot be excluded completely so that the
full compliance is not guaranteed. However, the information in this publication is updated
regularly. Required corrections are contained in the following regulations or can be down-
loaded on the Internet.
The current version is available for download on our web site http://www.iba-ag.com.
Windows® is a label and registered trademark of the Microsoft Corporation. Other prod-
uct and company names mentioned in this manual can be labels or registered trade-
marks of the corresponding owners.
Certification
The device is certified according to the European standards and directives. This device
corresponds to the general safety and health requirements. Further international cus-
tomary standards and directives have been observed.
Issue
Date
Revision
Chapter
Author
Version
HW / FW
1.4
01-2020
PCI version removed

Manual
ibaDeskline SAS
Issue 1.4 3
Table of contents
1About this manual ...........................................................................................5
1.1 Target group.................................................................................................. 5
1.2 Notations....................................................................................................... 5
1.3 Used symbols................................................................................................ 6
2Scope of delivery.............................................................................................7
3Versions ...........................................................................................................8
3.1 Factory setting............................................................................................... 8
4Safety instructions ..........................................................................................9
4.1 Designated use ............................................................................................. 9
4.2 Proper installation site ................................................................................... 9
5Description ....................................................................................................10
5.1 Front view ................................................................................................... 10
5.2 Top view .......................................................................................................11
5.3 Rear view .................................................................................................... 12
5.3.1 Standard system version............................................................................. 12
5.3.2 Version with redundant power supply .......................................................... 13
5.4 Internal view ................................................................................................ 14
5.5 Error monitoring .......................................................................................... 15
5.5.1 ibaOut-Tem p................................................................................................ 16
5.5.2 ibaOut-State................................................................................................ 17
6Installation, connection and first switching on ..........................................18
6.1 Safety instructions....................................................................................... 18
6.2 Setting up.................................................................................................... 18
6.3 Connection and first switching on................................................................ 19
7Installation of measuring or additional boards ..........................................20
7.1 Safety instructions and notes ...................................................................... 20
7.2 Basic procedure .......................................................................................... 20
7.3 Opening the device ..................................................................................... 21
7.4 Installing ibaOut-Temp/ibaOut-State............................................................ 22
8Maintenance work .........................................................................................26
8.1 Basic procedure .......................................................................................... 26
8.2 Power supply slide-in module for replacement of
redundant power supply unit........................................................................ 26
8.3 Restoring of a RAID system during operation.............................................. 27
9Installing operating system and iba software.............................................32
9.1 Installation................................................................................................... 32

Manual
ibaDeskline SAS
4
Issue 1.4
9.2 Installing Windows from the recovery medium ............................................ 32
9.2.1 General ....................................................................................................... 32
9.2.2 Select the language .................................................................................... 33
9.2.3 Enter the product key .................................................................................. 33
9.2.4 Partitioning.................................................................................................. 34
9.2.5 Completing installation ................................................................................ 36
9.3 Windows Updates ....................................................................................... 36
9.4 Antivirus Software ....................................................................................... 36
9.5 Installing iba software.................................................................................. 36
10 Technical data ............................................................................................... 37
10.1 Main data .................................................................................................... 37
10.2 Electronic components and interfaces......................................................... 38
10.3 Products...................................................................................................... 39
10.4 Device dimensions ...................................................................................... 40
11 Support and contact ..................................................................................... 41

ibaDeskline SAS
Manual
Issue 1.4
5
1 About this manual
This manual describes the construction, the use and the operation of the industrial PC
ibaDeskline SAS.
1.1 Target group
This manual addresses in particular the qualified professionals who are familiar with han-
dling electrical and electronic modules as well as communication and measurement tech-
nology. A person is regarded to as professional if he/she is capable of assessing safety
and recognizing possible consequences and risks on the basis of his/her specialist train-
ing, knowledge and experience and knowledge of the standard regulations.
1.2 Notations
The following designations are used in this manual:
Action Notations
Menu command Menu Logic diagram
Call of menu command Step 1 – Step 2 – Step 3 – Step x
Example:
Select menu Logic diagram – Add – New logic dia-
gram
Keys <Key name>
Example: <Alt>; <F1>
Press keys simultaneously <Key name> + <Key name>
Example:
<Alt> + <Ctrl>
Buttons <Button name>
Example:
<OK>; <Cancel>
File names, Paths „File name“, „Path”
Example:
„Test.doc“

Manual
ibaDeskline SAS
6
Issue 1.4
1.3 Used symbols
If safety instructions or other notes are used in this manual, they mean:
The non
-observance
of this safety information may result in an imminent risk of death or
severe injury:
By an electric shock!
Due to the improper handling of software products which are coupled to input and
output procedures with control function!
The non
-observance of
this safety information may result in a potential risk of death or
severe injury!
The non
-
observance of this safety information may result in a potential risk of injury or
material damage!
Note
A note specifies special requirements or actions to
be observed.
Important note
Note if some special features must be observed, for example exceptions from the rule.
Tip
Tip or example as a helpful note or insider tip to make the work a little bit easier.
Other documentation
Reference to
additional documentation or further reading.

ibaDeskline SAS
Manual
Issue 1.4
7
2 Scope of delivery
After unpacking check the completeness and intactness of the delivery.
The scope of delivery includes:
Industrial Computer ibaDeskline SAS
Keyboard
Mouse
Mains cable
Documentation (on DVD)
iba software license key (when a software was ordered)
The documentation contains:
Manual (pdf)
Third party documentation (pdf)
Windows 10 Enterprise Long-Term-Servicing Version or Windows Server Version
Recovery DVD (for the respective Windows version with all associated operating
system settings)
iba software, optional order
Hardware driver (motherboard, graphics card)
1 iba software license key (dongle), optional with iba software product
Serial number (iba-S/N)

Manual
ibaDeskline SAS
8
Issue 1.4
3 Versions
ibaDeskline SAS (Xeon E3, Windows 10 IoT Enterprise Long-Term-Servicing ver-
sion, PCIe) with one hard disk, can be upgraded with up to 7 further hard disks
Upgrade options:
RAID 1 system with 2 hard disks, 1 redundant power supply unit
Data are mirrored.
RAID 6 system with 8 hard disks, 1 redundant power supply unit
The net volume corresponds to the volume of approx. 6 hard disks with simultane-
ous high performance and system stability against failure.
Server system with Windows Server 2016 or higher
ibaDeskline with SSD disk (on request)
SSD (for upgrade)
Upgrade to RAID1 system for ibaDeskline with SSD
3.1 Factory setting
In delivery state, 2 users with or without password are configured:
User Password
pda -
Administrator
xadmin
Important note
Change the default passwords after you have put the PC into operation!
This way, un-
authorized
usage will be impeded.

ibaDeskline SAS
Manual
Issue 1.4
9
4 Safety instructions
4.1 Designated use
The device may be used only for the following applications:
Machine test and commissioning of industrial systems
Measurement data logging and analysis
Applications of ibaSoftware products (ibaPDA, ibaLogic etc.)
4.2 Proper installation site
According to manufacturer's specifications the device can only be installed on an even
non-slip installation surface, for example table or rack.
Electric Shock!
Before opening the device disconnect it from the mains and pull out the mains plug from
the socket equipped with earthing contact!
Never use the device with a damaged mains cable!
Before opening the device disconnect it from the mains by unplugging the cable from
the socket equipped with an earthing contact and wait for several minutes until the com-
ponents have cooled down! Thus you will avoid injuries due to the electric shock or
burns!
Connect the device to one supply voltage only according to specifications on the b
uilt
-
in power supply unit!
Always use a socket equipped with earthing contact! Use a terminal strip with overvolt-
age protection or an uninterruptible power supply (UPS)!
Always connect the device to earthed power networks (TN
-
networks according to VDE
0100
Part 300 and IEC 60364-
3)! The operation via ungrounded networks or networks
(IT networks) earthed via impedance is not permitted!
In case of faults, a defective device or a possible defect pull out the mains plug from the
socket equipped with earthing co
ntact!
Never put a damaged device into operation!
Pay attention to sharp edges in the housing!
Never switch off the device by means of the mains switch without previous shutdown of
the device.
Electrostatic discharge!
Touch the components only in electrostatically discharged state!

Manual
ibaDeskline SAS
10
Issue 1.4
5 Description
5.1 Front view
ibaDeskline
Optical drive with integrated writing function
Plug-in slots for hard disks

ibaDeskline SAS
Manual
Issue 1.4
11
5.2 Top view
ibaDeskline
1 USB 2.0 interfaces
2 USB 3.0 interfaces
3 Headset interface
4 Microphone interface
5 Power button
6 Reset button

Manual
ibaDeskline SAS
12
Issue 1.4
5.3 Rear view
5.3.1 Standard system version
Connections for external devices (keyboard, mouse, network etc.)
Slots X20 to X26 (for low-profile iba cards)
Slot X2 for hard disk controller
Slots X3 to X7 (PCIe, in the example with 2 ibaFOB-D cards1)
Slot X8 DVI connection
Power supply with switch and panel plug for non-heating appliances
1Not included in delivery

ibaDeskline SAS
Manual
Issue 1.4
13
5.3.2 Version with redundant power supply
RAID systems are equipped with a redundant power supply unit.
Connections for external devices (keyboard, mouse, network etc.)
Slots X20 to X26 (for low-profile iba cards, e. g. output connections of FOB-4i cards)
Slot X2 for hard disk controller
Slots X3 to X7 (PCIe, in the example with 2 ibaFOB-D cards2)
Slot X8 DVI connection
2x Power supply with switch and panel plug for non-heating appliances, replaceable
2Not included in delivery

Manual
ibaDeskline SAS
14
Issue 1.4
5.4 Internal view
Power supply unit (redundant for RAID systems)
PCIe slots
Hard disk controller
Slots for low-profile iba cards
Drive bracket
Fan ( Ø 12 cm)
Internal USB port (dongle)

ibaDeskline SAS
Manual
Issue 1.4
15
5.5 Error monitoring
Example: Built-in ibaOut-Temp card
The temperature and the status of the power supply unit can be monitored with the slot
cards ibaOut-Temp and ibaOut-State. The cards can be ordered separately as acces-
sory. If the card is ordered with ibaDeskline, it is installed by default in slot X20. If the
plug-in card is installed at a later time, please refer to chapter 7.4.
The status of temperature and power supply unit are indicated each with a bicolored
LED.
LED Status Description
TEMP green
red
Temperature OK
Overtemperature
POWER green
red
Power supply OK
Power supply error
Redundant power supply: error in one of the two power
supply units

Manual
ibaDeskline SAS
16
Issue 1.4
5.5.1 ibaOut-Temp
ibaOut-Temp provides two relay outputs for temperature and power supply (2-pin con-
nector), which can be used to indicate errors. Both error types are indicated separately.
The switch position of the outputs is as follows:
Status Switch POWER Switch TEMP
Power off or power error closed open
Power OK, temperature OK open open
Power OK, overtemperature open closed
Contact loading capacity
Nominal current: 400 mA
Nominal voltage: 60 V
Compatibility to previous models
ibaDeskline computers of older type series provide only one relay output for error indi-
cation. The relay contact is closed when an error occurs, without differentiating between
overtemperature or a power supply error.
ibaOut-Temp can be used in the same way, when both outputs are connected to one
output (parallel circuit).
Wiring diagram of the parallel circuit:

ibaDeskline SAS
Manual
Issue 1.4
17
5.5.2 ibaOut-State
ibaOut-State provides an output (6-pin connector) which can be used to indicate errors.
Both error types are indicated separately.
These are the switch positions:
Switch state switch state
Power OK,
temperature OK
Power off or
Power error and
overtemperature
Power error,
temperature OK
Power OK,
overtemperature
Contact loading capacity
Nominal current: 300 mA
Nominal voltage: 220 V DC
Compatibility to previous PC models
The behavior of ibaOut-State is identical with the previous models with a relay output, if
pin 5 and 6 are used. The relay contact of the previous iba-PC models is closed when
an error occurs, without differentiating between overtemperature or a power supply error.

Manual
ibaDeskline SAS
18
Issue 1.4
6 Installation, connection and first switching on
6.1 Safety instructions
Electric Shock!
Never use the device with a damaged mains cable!
Connect the device to one supply voltage only according to specifications on the built-
in power supply unit!
Always use a socket equipped
with earthing contact! Use a terminal strip with overvolt-
age protection or an uninterruptible power supply (UPS)!
Connect the device only to earthed power networks (TN
-
networks according to
VDE
0100 Part 300 or IEC 60364-3)!
The operation via ungrounded networks or networks (IT networks) earthed via imped-
ance is not permitted!
Never put a damaged device into operation!
6.2 Setting up
Place the device only in the location which has the following properties:
Stationary
Shock-free
In the protected room, for example switch cabinet
Dust-free and dry environment
Even and non-slip base
Note
If you embed the device, observe the minimum bending radii of the cables and lines.
The mounting clearance must be at least 150 mm from the rear wall.
E
nsure sufficient air circulation.

ibaDeskline SAS
Manual
Issue 1.4
19
6.3 Connection and first switching on
Note
Before switching on the device
for the first time
check if the power supply is connected
properly and the connecting cable (fiber optic and copper data cable) are plugged. The
device is delivered
in a pre-
installed and configured state. You can find the parameters
of the operating system and ibaSoftware in the corresponding manuals or in the Online
Help.
1. Connect the device to a mains socket using the mains cable.
2. Connect all cables.
3. Switch on the device using the mains switch.
4. Boot the device. Press the Power button.
The computer is booted automatically with Windows.
5. Finally, start all iba-software applications.

Manual
ibaDeskline SAS
20
Issue 1.4
7 Installation of measuring or additional boards
7.1 Safety instructions and notes
Electric Shock!
Before opening shut down the device! After that disconnect it from the mains and pull
out the mains plug from the socket equipped with earthing contact!
Wait for several minutes after switching
off until the components have cooled down!
Thus you will avoid injuries due to the electric shock or burns!
Pay attention to sharp edges in the housing!
Electrostatic discharge!
Touch the components only in electrostatically discharged state!
Note
If you upgrade the device, observe the instructions in the
third party documentation.
Back up all data on an external storage medium.
7.2 Basic procedure
If you carry out any work at the device, always proceed in the following way:
1. Remove all mobile data carriers (DVD, memory cards and so on).
2. Shut down the device.
3. Switch off the device.
4. Unplug the mains cable from the socket.
5. Remove the side panel (If you want to exchange cards, remove the left side panel).
6. Carry out upgrade operations.
7. Attach the side panel again.
8. Put the device into operation again.
Other manuals for ibaDeskline SAS
1
This manual suits for next models
2
Table of contents
Other IBA Industrial PC manuals
Popular Industrial PC manuals by other brands

Dell
Dell Embedded Box PC 5000 Installation and operation manual

IBASE Technology
IBASE Technology ASB200-918 Series user manual

Lenovo
Lenovo ThinkCentre M90q Hardware Maintenance Manual

IXXAT
IXXAT Econ 100 Hardware manual

Kontron
Kontron KBox A-151-TGL user guide

AXIOMTEK
AXIOMTEK ICO500-518 Series user manual