ICA UPS ST Series User manual

ST 1023 B
ST 623 B
ICA
UNINTERRUPTIBLE
POWER
SYSTEMS
ST-SERIES
U P S
481-1180070-121Rev. 03
USER MANUAL
(BUKU PETUNJUK PEMAKAIAN)

VIII.
IX.
INTRODUCTION / PENDAHULUAN
SAFETY NOTES / CATATAN KESELAMATAN
TECHNICAL SPECIFICATION / SPESIFIKASI TEKNIK
FRONT PANEL & REAR PANEL VIEW /
TAMPAK PANEL DEPAN & PANEL BELAKANG
3
1
Page / Halaman
4
5
START UP UPS / MENGHIDUPKAN UPS
OPERATION PROCEDURE / CARA MENGOPERASIKAN
UPS INSTALLATION / PEMASANGAN UPS
6
7
7
TABLE OF INDICATOR STATUS / TABEL STATUS INDIKATOR
TROUBLE SHOOTING / PETUNJUK KETIDAK NORMALAN
8
9
II.
I.
III.
IV.
V.
VI.
VII.
CONTENTS / DAFTAR ISI

I. SAFETY NOTES / CATATAN KESELAMATAN
1
I.1. Electrical Safety
I.2. Deenergizing Safety
● If the UPS has an internal energy source (battery), the
output may be energized when the unit is not connected to a
utility power outlet.
● To deenergize a pluggable UPS, press the OFF button or
switch to shut the equipment off. Unplug the UPS from the
utility power outlet. Disconnect the external batteries where
applicable and disconnect the internal battery. Push the ON
button to deenergize the capacitors.
I.1. Keselamatan Listrik
● .Jangan bekerja sendiri dalam situasi berbahaya
● Tegangan tinggi melalui bahan konduktif dapat
menyebabkan luka bakar.
● Periksa agar kabel listrik, fiting, dan soket berada dalam
kondisi baik.
● Bila grounding tak dapat diverifikasi, putuskan hubungan
peralatan listrik dengan keluaran listrik AC sebelum
memasang atau menghubungkannya dengan peralatan lain.
Hubungkan kembali dengan kabel listrik hanya jika
seluruhnya selesai dihubungkan.
● Hubungkan peralatan ke keluaran listrik AC tiga kabel
(dua kutub dan ground). Soket penerima harus terhubung
secara benar melalui sirkuit cabang/pelindung utama
(sekring atau pemutus arus). Hubungan ke soket penerima
dalam bentuk lainnya dapat menyebabkan bahaya sengatan
listrik.
● Jika alat memiliki sumber energi internal (batterai), output
mungkin masih mengandung arus listrik walaupun unit
tidak terhubung dengan tegangan listrik AC.
● Untuk membuang arus listrik dari UPS yang terhubung,
tekan tombol OFF untuk mematikan alat. Putuskan alat dari
outlet listrik AC. Lepaskan batterai dan putuskan batterai
internal. Tekan tombol ON untuk membuang listrik di
dalam kapasitor.
I.2. Keselamatan Saat Membuang Arus Listrik
● ot work alone under hazardous conditions.Do n
● High current through conductive materials could cause
severe burns.
● (s), plug(s), and socket are in Check that the power cord
good condition.
● , disconnect the When grounding cannot be verified
equipment from the utility power outlet before installing or
connecting to other equipment. Reconnect the power cord
only after all connections are made.
● two Connect the equipment to a three wire utility outlet (
pole plus ground). The receptacle must be connected to
appropriate branch circuit/ mains protection (fuse or circuit
breaker). Connection to any other type of receptacle may
result in risk of electrical shock.

I.3. Battery Safety I.3. Keselamatan Baterai
● .Repair are to be performed only by qualified personnel
● Do not dispose of batteries in a fire. The batteries may
explode.
● Do not open or mutilate batteries. They contain an
electrolyte that is toxic and harmful to the skin and eyes.
● Replace batteries with the same number and type of
batteries as originally installed in the equipment.
● Perbaikan hanya dilakukan oleh seorang teknisi yang
memiliki kualifikasi.
● Jangan buang batterai ke dalam api, dapat meledak.
● Jangan membongkar batterai. Batterai mengandung
elektrolit yang beracun dan dapat merusak kulit dan mata.
● Ganti batterai dengan nomor dan jenis yang sama seperti
aslinya terpasang dalam alat.
Jangan buang sisa kemasan produk ini sebagai limbah rumah
tangga: Bawa ke tempat pengumpulan untuk didaur ulang.
Untuk informasi tentang tempat daur ulang terdekat, hubungi
petugas pembuangan limbah setempat.
Pembuangan produk
UPS berisi bahan internal yang (dalam kasus pembuangan)
dianggap LIMBAH BERACUN dan BERBAHAYA, seperti
papan sirkuit elektronik dan baterai. Perlakukan bahan-bahan
ini sesuai dengan undang-undang yang berlaku dengan
merujuk pada personel servis yang berkualifikasi. Pembuangan
yang tepat berkontribusi untuk menghormati lingkungan dan
kesehatan manusia.
Disposing of the product
The UPS contains internal material that (in case of disposal)
are considered TOXIC and HAZARDOUS WASTE, such as
electronic circuit boards and batteries. Treat these materials
according to the laws applicable referring to qualified service
personnel. Their proper disposal contributes to respect the
environment and human health.
Do not dispose of leftover packaging for this product as
household waste: Take it to a collection point for recycling.
For information about the nearest recycling facility, contact
your local waste disposal authority.
2

UPS (Uninterruptible Power Supplies) can provide full
protection against all of power problem for your sensitive
equipment ranging from computer, computerized instrument,
PABX, facsimile, cash register to all electronic equipment.
This UPS consists of inverter, batteries, battery charger,
control circuit, stabilizer, transfer switch and indicator. When
line power is normal, the UPS filters line power input and by
pass to output UPS and at the same time the batteries is
being charged by battery charger. And when line power fails
(off, voltage too low) inverter will supply regulated AC
power to the load within ≤ 4 ms transfer time so that the
power supplied to the load is uninterrupted. And when line
power is normal automatically load gets from line power
again.
This UPS is also completed by interface for
communication with computer, with operating system
Windows and Linux.
UPS (Uninterruptible Power Supplies) dapat melindungi
peralatan anda yang rentan terhadap gangguan kelistrikan
seperti: komputer, instrument terkomputerisasi, PABX,
faksimili, cash register dan peralatan elektronik lainnya.
UPS ini terdiri atas inverter, baterai, pengisi baterai,
rangkaian pengendali, stabilisator, saklar-pengalih dan
indikator. Saat listrik jala-jala normal, UPS menyaring listrik
masukan dan menyalurkannya pada keluaran UPS, pada saat
yang sama baterai diisi oleh pengisi baterai. Manakala terjadi
gangguan listrik (padam, tegangan terlalu rendah) inverter
seketika bekerja dengan waktu alih ≤ 4 ms sehingga pasokan
listrik pada beban tidak terganggu/ terputus. Dan bila listrik
jala-jala pulih maka otomatis beban mendapat daya listrik
jala-jala kembali.
UPS ini dilengkapi interface untuk berkomunikasi
dengan komputer, dengan sistem operasi Windows dan
Linux.
II. INTRODUCTION / PENDAHULUAN
3
AC INPUT UPS OUTPUT
TRANSFER
SWITCH
INVERTERCHARGER
BATTERY
STABILIZER
&
INDICATOR
CONTROL CIRCUIT
TO COMPUTER

50 ± 3
Sinewave
< 3% THD
220 ± 2%
50 ± 1%
≤ 4
10
Every 4 seconds
Every 1 second
Every 1 second
0 ~ 40
± 80
Constant Voltage
Hz
A
V
V
Hz
%
V
ms
min
C
mm
Kg
Fuse
Load 0 ~ 100%
At Full Load
On Line
At Nominal Load
Sealed Lead Acid Battery
D x W x H
Transfer Time if Input Failure
Back Up Time
AC Input Low/ Fail
AC Input High
Battery Low
Operating Temperature
BUZ
ZER
Dimension
Weight
A
C
IN
DC
IN
I
N
V
O
U
T
CHG
Frequency
Protection
Internal Battery
Protection
Voltage
Wave Form
Distortion
Voltage
Frequency
Topology
Efficiency
Topology
Floating Voltage
6,3 10
2 x 12V, 7AH 3 x 12V, 7AH
Fuse
24 36
425 x 140 x 200 505 x 140 x 200
14 18
27,0 40,5
Pulse Width Modulation (PWM)
ITEM SPECIFICATION
UNIT
V
VA/W
160 ~ 250
REMARKS
MODEL
Capacity
Voltage
ST623B ST1023B
1200 / 600 2000 / 1000
III. TECHNICAL SPECIFICATION / SPESIFIKASI TEKNIK
4

1. Main Switch / Tombol Daya
2. Green Led / Led Hijau
3. Yellow Led / Led Kuning
4. Red Led / Led Merah
5. Red Led / Led Merah
6. Inverter Test / Test Inverter
7. USB Port / Port USB*
8. Outlet / Stopkontak Keluaran
9. Inlet / Stopkontak Masukan
10. Jack RJ11*
: To turn on and off the UPS / Untuk menghidupkan dan mematikan UPS.
: Indicate output UPS from line power /
: Indicate output UPS from inverter /
: Indicate low battery / Menunjukkan keadaan baterai hampir habis.
: Indicate overload / Menunjukkan keadaan beban lebih.
: To inverter test when line power on /
: For communication between UPS and computer /
Untuk melakukan test inverter, saat AC input ada.
Untuk komunikasi antara UPS dengan komputer.
Menunjukkan keluaran UPS dari listrik jala-jala.
Menunjukkan keluaran UPS berasal dari Inverter.
: Internet modem protection / Perlindungan modem internet.
* Notice :
Please disconnect all communication connectors before disconnecting main power cord from receptacle.
Putuskan semua konektor komunikasi sebelum mencabut kabel daya utama dari stopkontak.
USE ONLY WITH A 230V FUSE
ST 623 B
ICA
7
8
10
9
2
3
6
1
4
5
REAR PANEL VIEW
ST623B, ST1023B
FRONT PANEL VIEW
ST623B, ST1023B
IV. FRONT PANEL & REAR PANEL VIEW / TAMPAK PANEL DEPAN & PANEL BELAKANG
5

1. Make sure Main Switch on the “off” position and no load is
connected to the outlet.
2. Connect inlet with power cord to a power receptacle with
earth ground.
3. Turn on the UPS by pressing power button. the red led of
BATTERY LOW lights for about 2 seconds and will; go out
when the battery is in good condition. At the same time the
green led of LINE ON light (if line voltage > 170V and <
255V) which indicates UPS output is from line power.
4. Disconnect inlet from line power, the green led of LINE ON
will go out while the yellow led of INVERTER will light on
and audible alarm will sound every 4 seconds.
5. Connect inlet to line power again and then after 2 seconds
the yellow led of INVERTER will go out while the green
led of LINE ON will light on.
6. Now your UPS is ready for operation. Connect the
equipment that is going to be supplied by the UPS into the
UPS.
Notes:
The UPS battery should charge for at least 10 hours to ensure
sufficient runtime. The unit is being charged whenever it is
connected to utility power, and UPS must be turn ON.
1. Pastikan tombol pada posisi “off” dan tidak ada beban yang
terpasang pada stopkontak keluaran.
2. Hubungkan steker kabel daya ke stopkontak jala-jala yang
mempunyai arde.
3. Hidupkan UPS dengan menekan tombol daya. Led merah
TEGANGAN BATERAI RENDAH akan menyala sekitar 2
detik dan padam kembali bila kondisi baterai baik.
Bersamaan dengan itu led hijau LISTRIK JALA-JALA
menyala (bila tegangannya > 170V dan < 255V) yang
menunjukkan keluaran UPS berasal dari listrik jala-jala.
4. Cabut steker kabel daya dari stopkontak jala-jala maka led
hijau LISTRIK JALA-JALA padam sedangkan led kuning
INVERTER akan menyala dan buzzer akan berbunyi setiap
4 detik.
5. Pasang kembali steker maka sekitar 2 detik kemudian led
kuning INVERTER padam sedangkan led hijau akan
menyala.
6. Sekarang UPS siap menjalankan fungsinya. Hubungkan
peralatan yang akan diberi pasokan daya pada stopkontak
keluaran UPS.
Catatan:
Baterai UPS harus di isi sekurangnya 10 jam untuk
memastikan UPS beroperasi dengan memadai. Unit akan
mengisi bilamana dihubungkan dengan sumber listrik, dan
UPS harus dihidupkan.
V. START UP UPS / MENGHIDUPKAN UPS
6

1. Turn on procedure:
a. Press on power button at the front panel.
b. Turn on the load connected to the outlet.
2. When the line is interrupted.
In case of line power is interrupted (off or voltage is too
low/high), inverter converts the battery power to AC power
automatically with transfer time ≤ 4 ms. Buzzer will sound
at interval 4 seconds if the line power off or <170V and
interval 1 second if the line power >255V. When the battery
is near the end of its capacity, buzzer will sound
continuously. At this time data should be stored and all load
shutdown.
3. Turn off procedure:
a. Turn off all the load connected to the outlet.
b. Press on power button at the front panel.
1. Cara menghidupkan:
a. Tekan tombol daya pada panel depan.
b. Hidupkan beban yang terpasang pada stopkontak
keluaran.
2. Saat listrik jala-jala terganggu (padam atau tegangannya
terallau rendah/tinggi), inverter langsung bekerja dengan
waktu alih ≤ 4 ms mengubah daya baterai menjadi arus
listrik AC. Buzzer akan berbunyi putus-putus selang 4 detik,
jika listrik jala-jala mati atau <170V dan selang 1 detik jika
listrik jala-jala >255V. Saat baterai hampir habis buzzer
akan berbunyi sinambung. Pada saat ini data harus sudah
tersimpan dan semua beban harus sudah dimatikan.
3. Cara mematikan:
a. Matikan semua beban yang terpasang pada UPS.
b. Tekan tombol daya pada panel depan.
1. Location selection
This UPS should be located in protected place.
2. Installation
This UPS must be connected to a power receptacle with
earth ground.
a. Make sure main switch on the off position.
b. Connect the UPS to the available outlet.
1. Pemilihan lokasi
Letakkan UPS ini pada tempat yang terlindung.
2. Pemasangan
UPS ini harus dihubungkan pada stopkontak yang
mempunyai hubungan ke bumi (arde).
a. Pastikan Main Switch pada posisi off.
b. Hubungkan UPS dengan stopkontak yang tersedia.
VI. OPERATION PROCEDURE / CARA MENGOPERASIKAN
VII. UPS INSTALLATION / PEMASANGAN UPS
7

STATUS
CONDITION
MAIN
SWITCH
BUZZER
NP NTPL NTPC
LED
L1 L2 L3 L4 REMARKS
Normal 1 0 0 0 0 0 01
0 0100 011No line voltage
Line voltage too low 0 0100 011 Check the utility power, make
sure between 170-255 vac
0 0100 101 Check the utility power,
< 260 vac
Line voltage too high
1 0100 101
Inverter is on at low battery
voltage
Save your work now, the inverter
will be cut off
0 1011 001 Remove some load from the UPS
1. Utility power is normal
2. Overload
Remarks : 1 : On
0 : Off
L1 : Green Led (Line On)
L2 : Yellow Led (Inverter)
L3 : Red Led (Battery Low)
L4 : Red Led (Overload)
NP : Audible alarm continuous sounds
NTPL : Audible alarm sound every 4 seconds
NTPC : Audible alarm sound every 1 second
Note :
If indicates out of the table, turn off power button and call for service.
VIII. TABLE OF INDICATOR STATUS / TABEL STATUS INDIKATOR
8

SYSTEM PROBLEM CAUSE RECOMMENDED SOLUTION
“Line On” indicator not light. 1. Main voltage < 170 Vac or > 255 Vac.
2. Problem in transfer switch control.
1. Check your mains voltage.
2. If main voltage > 170 vac and < 255 Vac,
call for service.
1. Check battery voltage.
2. Charger battery ± 10 hour by kept the
mains switch in on position when AC
mains normal.
3. Call for service.
Battery voltage low.
Main voltage < 170 Vac, turn on
main switch, battery low light on
after ± 5 seconds go out, but
inverter does not work.
When AC main failure and inverter
does not work.
1. Battery fuse broken.
2. Problem in inverter circuit.
1. Check battery fuse and replace with the
same rating.
2. If the fuse blown again, call for service.
Communication from UPS to
computer fail.
1. Interface cable not connected.
2. Interface cable wrong or broken.
3. Software has not been installed or
configure properly.
Install the interface cable.
See software manual.
If the problem still occur, call for service.
IX. TROUBLE SHOOTING / PETUNJUK KETIDAKNORMALAN
9

SERVICE CENTRE
ICA
Jln. Pinangsia Raya I No: 22BB
Jakarta - 11120
Phone : (021) 6906020 (Hunting)
ICA
Notes :
For further information, please visit “www.icaups.co.id”.
----------------------------------------------------------------------------------
Catatan :
Untuk informasi lebih lanjut, silakan kunjungi “www.icaups.co.id”.
Other manuals for UPS ST Series
3
This manual suits for next models
2
Table of contents
Other ICA UPS manuals
Popular UPS manuals by other brands

Tescom
Tescom XC Series user manual

Bosch
Bosch Rexroth IndraControl VAU 01.1 Series operating instructions

Marathon
Marathon SuperCap 1000VA user manual

socomec
socomec NRT2-U1100 Installation and operating manual

socomec
socomec NETYS RT Installation and operating manual

Eaton
Eaton Powerware 9395 User and installation guide