ICA UPS ST Series User manual

ICA
UNINTERRUPTIBLE
POWER
SYSTEMS
ST-SERIES
U P S ST 531C
ST 831C
ST 1231C
ST 1631C
481-1180020-131Rev. 03
USER MANUAL
(BUKU PETUNJUK PEMAKAIAN)

VIII.
IX.
INTRODUCTION / PENDAHULUAN
SAFETY NOTES / CATATAN KESELAMATAN
TECHNICAL SPECIFICATION / SPESIFIKASI TEKNIK
FRONT PANEL & REAR PANEL VIEW /
TAMPAK PANEL DEPAN & PANEL BELAKANG
3
1
Page / Halaman
4
5
INDICATOR STATUS / STATUS INDIKATOR
START UP UPS / MENGHIDUPKAN UPS
OPERATION PROCEDURE / CARA MENGOPERASIKAN
6
7
8
TABLE OF INDICATOR STATUS / TABEL STATUS INDIKATOR
TROUBLE SHOOTING / PETUNJUK KETIDAK NORMALAN
9
10
II.
I.
III.
IV.
V.
VI.
VII.
CONTENTS / DAFTAR ISI

I. SAFETY NOTES / CATATAN KESELAMATAN
1
I.1. Electrical Safety
I.2. Deenergizing Safety
● If the UPS has an internal energy source (battery), the
output may be energized when the unit is not connected to a
utility power outlet.
● To deenergize a pluggable UPS, press the OFF button or
switch to shut the equipment off. Unplug the UPS from the
utility power outlet. Disconnect the external batteries where
applicable and disconnect the internal battery. Push the ON
button to deenergize the capacitors.
I.1. Keselamatan Listrik
● .Jangan bekerja sendiri dalam situasi berbahaya
● Tegangan tinggi melalui bahan konduktif dapat
menyebabkan luka bakar.
● Periksa agar kabel listrik, fiting, dan soket berada dalam
kondisi baik.
● Bila grounding tak dapat diverifikasi, putuskan hubungan
peralatan listrik dengan keluaran listrik AC sebelum
memasang atau menghubungkannya dengan peralatan lain.
Hubungkan kembali dengan kabel listrik hanya jika
seluruhnya selesai dihubungkan.
● Hubungkan peralatan ke keluaran listrik AC tiga kabel
(dua kutub dan ground). Soket penerima harus terhubung
secara benar melalui sirkuit cabang/pelindung utama
(sekring atau pemutus arus). Hubungan ke soket penerima
dalam bentuk lainnya dapat menyebabkan bahaya sengatan
listrik.
● Jika alat memiliki sumber energi internal (batterai), output
mungkin masih mengandung arus listrik walaupun unit
tidak terhubung dengan tegangan listrik AC.
● Untuk membuang arus listrik dari UPS yang terhubung,
tekan tombol OFF untuk mematikan alat. Putuskan alat dari
outlet listrik AC. Lepaskan batterai dan putuskan batterai
internal. Tekan tombol ON untuk membuang listrik di
dalam kapasitor.
I.2. Keselamatan Saat Membuang Arus Listrik
● ot work alone under hazardous conditions.Do n
● High current through conductive materials could cause
severe burns.
● (s), plug(s), and socket are in Check that the power cord
good condition.
● , disconnect the When grounding cannot be verified
equipment from the utility power outlet before installing or
connecting to other equipment. Reconnect the power cord
only after all connections are made.
● two Connect the equipment to a three wire utility outlet (
pole plus ground). The receptacle must be connected to
appropriate branch circuit/ mains protection (fuse or circuit
breaker). Connection to any other type of receptacle may
result in risk of electrical shock.

I.3. Battery Safety I.3. Keselamatan Baterai
● .Repair are to be performed only by qualified personnel
● Do not dispose of batteries in a fire. The batteries may
explode.
● Do not open or mutilate batteries. They contain an
electrolyte that is toxic and harmful to the skin and eyes.
● Replace batteries with the same number and type of
batteries as originally installed in the equipment.
● Perbaikan hanya dilakukan oleh seorang teknisi yang
memiliki kualifikasi.
● Jangan buang batterai ke dalam api, dapat meledak.
● Jangan membongkar batterai. Batterai mengandung
elektrolit yang beracun dan dapat merusak kulit dan mata.
● Ganti batterai dengan nomor dan jenis yang sama seperti
aslinya terpasang dalam alat.
Jangan buang sisa kemasan produk ini sebagai limbah rumah
tangga: Bawa ke tempat pengumpulan untuk didaur ulang.
Untuk informasi tentang tempat daur ulang terdekat, hubungi
petugas pembuangan limbah setempat.
Pembuangan produk
UPS berisi bahan internal yang (dalam kasus pembuangan)
dianggap LIMBAH BERACUN dan BERBAHAYA, seperti
papan sirkuit elektronik dan baterai. Perlakukan bahan-bahan
ini sesuai dengan undang-undang yang berlaku dengan
merujuk pada personel servis yang berkualifikasi. Pembuangan
yang tepat berkontribusi untuk menghormati lingkungan dan
kesehatan manusia.
Disposing of the product
The UPS contains internal material that (in case of disposal)
are considered TOXIC and HAZARDOUS WASTE, such as
electronic circuit boards and batteries. Treat these materials
according to the laws applicable referring to qualified service
personnel. Their proper disposal contributes to respect the
environment and human health.
Do not dispose of leftover packaging for this product as
household waste: Take it to a collection point for recycling.
For information about the nearest recycling facility, contact
your local waste disposal authority.
2

UPS ST Series adalah Uninterruptible Power Supplies jenis
tidak terputus dengan output sinusoida yang menggunakan
teknologi PWM (Pulse Width Modulation) tegangan tinggi dan
dilengkapi dengan static transfer switch. UPS ini menghasilkan
sumber daya output yang sangat stabil dan bebas dari tegangan
transient, jadi sangat baik untuk digunakan pada peralatan yang
sensitif seperti komputer, sistem telekomunikasi, dan peralatan
canggih lainnya.
UPS ini mempunyai kemampuan beban non-linier yang
tinggi (crest ratio 3:1), sehingga memungkinkan untuk
digunakan pada beban-beban seperti switching power supply
atau beban kapasitif tinggi.
Static transfer switch (STS) adalah sistem pemintasan daya
UPS. Manakala inverter mengalami kegagalan atau mendapat
beban lebih, STS akan mengalihkan sumber daya untuk
keluaran UPS dari inverter kepada daya dari jala-jala/ PLN
(apabila daya jala-jala ada) dengan waktu alih 0 ms. STS
otomatis akan kembali mengambil daya dari inverter dalam
waktu 2 ms apabila sistem kembali ke kondisi normal.
UPS ini dilengkapi juga interface untuk berkomunikasi
dengan komputer, baik dengan sistem operasi Windows dan
Linux. Informasi yang diberikan ke komputer adalah saat PLN
mati dan pada saat baterai hampir habis.
The ST Series UPS is an advanced true on-line sinewave
Uninterruptible power Supplies with high voltage PWM (pulse
Width Modulation) technology and static transfer switch. the
UPS can provide reliable, regulated, transient free AC power to
sensitive equipment ranging from computers and
telecommunication systems to computerized instrument.
The UPS has high non-linear load current capability (crest
ratio 3:1) and this is suitable for powering special loads such
switching power supplies or high capacitive load.
The static transfer switch (STS) system provides bypass
power as its standby source. Upon inverter failure or overload,
the STS will switch the output power Bypass (if the power line
exists) within 0 ms. The STS can retransfer back to inverter
automatically when the system is restored to normal condition
within 2 ms.
This UPS is also provided completed by interface for
communication with computer, with operating system
Windows and Linux. Information from UPS to computer is
power fail and battery low.
II. INTRODUCTION / PENDAHULUAN
3
= =
=
=
=
=
~~
C H A R G E R
S TATIC SWITCH
B Y PA S S
I N V O U T P U T
I N P U T
B AT T E R Y
W I T H P F C
R E C T I F I E R
C O N V E R T E R
I S O L AT I O N
I N V E R T E R

50 ± 3
Sinewave
< 3% THD
220 ± 2%
50 ± 1%
0
2 ms from Inverter to Bypass
Zero crossing Bypass to Inverter
10
Every 4 seconds
Every 1 second
0 ~ 40
> 85
Switching Regulation
Hz
A
V
V
Hz
%
V
ms
ms
min
C
mm
Kg
Fuse
Load 0 ~ 100%
At Full Load
On Line
At Nominal Load
Sealed Lead Acid Battery
D x W x H
Transfer Time if Input Failure
Transfer Time S.T.S.
Back Up Time
AC Input Low/ Fail
Battery Low
Operating Temperature
BUZ
ZER
Dimension
Weight
A
C
IN
DC
IN
I
N
V
O
U
T
CHG
Frequency
Protection
Internal Battery
Protection
Voltage
Wave Form
Distortion
Voltage
Frequency
Topology
Efficiency
Topology
Floating Voltage
5 7 10 15
2 x 12V, 7AH 4 x 12V, 7AH 6 x 12V, 7AH 8 x 12V, 7AH
Fuse
24 48 72 96
395 x 190 x 290 510 x 190 x 330
18 23 31 35
27,0 54,0 81,0 108,0
Pulse Width Modulation (PWM)
ITEM SPECIFICATION
UNIT
V
VA/W
160 ~ 250
REMARKS
MODEL
Capacity
Voltage
ST531C ST831C ST1231C ST1631C
1000 / 500 1600 / 800 2400 / 1200 3200 / 1600
4
III. TECHNICAL SPECIFICATION / SPESIFIKASI TEKNIK

UTICONUTICON
FUSE
UTICONUTICONUTICON
FUSE
FUSE
UTICONUTICONUTICON
FRONT PANEL VIEW REAR PANEL VIEW
UPS ST831C
REAR PANEL VIEW
UPS ST531C
REAR PANEL VIEW
UPS ST1231C, ST1631C
3 3
2
1
4
4
4
5 5 5
6 6
7 7 7
8 8
8
3
6
= =
=
=
=
=
~~
CHA R G E R
STAT IC SW IT CH
BYPA S S
INV OUT P U T
OVE R L O A D
FAUL T
BAT T E RY
LEV E L
INP U T
BATT E R Y
WIT H PFC
REC T I F I E R
CON V E R T E R
ISO L AT I O N
INV E R T E R
FULLLOW
ST 83 1C
ICA
1. Panel Monitor
2. Main Switch / Tombol Daya
4. Outlet / Stopkontak Output
3. RS232 Connector / Konektor RS232
5. Input Fuse / Fuse Input
6. External Battery (Optional) / Baterai Luar (Tambahan)
7. Inlet / Stopkontak Input
8. Ventilation / Lubang Angin
: To turn on and off the UPS / Untuk menghidupkan dan mematikan UPS.
: For communication between UPS and computer / Untuk komunikasi antara UPS
dengan komputer
* Notice :
Please disconnect all communication connectors before disconnecting main power cord from receptacle.
Putuskan semua konektor komunikasi sebelum mencabut kabel daya utama dari stopkontak.
IV. FRONT PANEL & REAR PANEL VIEW / TAMPAK PANEL DEPAN & PANEL BELAKANG
5

7. Fault
6. Over Load
5. Inverter On
4. Inverter Output
3. Bypass
2. Battery Level
1. Line On
: Red led, indicate inverter fault / Led merah, menunjukkan adanya gangguan pada inverter.
: Red led, indicate overload / Led merah, menunjukkan keadaan beban lebuh.
: Green led, indicate inverter on / Led hijau, menunjukkan inverter bekerja.
: Green led, indicate output UPS from inverter / Led hijau, menunjukkan output berasal dari inverter.
: Yellow led, indicate output UPS from AC input / Led kuning, menunjukkan output berasal dari PLN.
: 6 leds, indicates status of battery / 6 buah led, menunjukkan keadaan baterai.
: Green led, indicate AC power on / Led hijau, menunjukkan PLN ada.
= =
=
=
=
=
~~
C H A R G E R
S TAT I C S W I T C H
B Y PA S S
I N V O U T P U T
O V E R L O A D
FA U L T
B AT T E R Y
L E V E L
I N P U T
B AT T E R Y
W IT H P FC
R E C T I F I E R
C O N V E R T E R
I S O L AT I O N
I N V E R T E R
FULLLOW
5
3
4
6
7
1
2
V. INDICATORS STATUS / STATUS INDIKATOR
6

1. Make sure main switch is in the off position and no load is
connected to the UPS output.
2. Connect inlet to the mains. the indicator “INPUT” will
light on.
3. Turn on the main switch, the indicator “INVERTER” light
on and the indicator “BYPASS” light on for about 20
seconds, and will go out, at the same time battery level led
will light on (depend on the battery condition) and the
indicator “INVERTER OUTPUT” will light on.
4. Disconnect inlet from the mains, the indicator “INPUT”
will go out and audible alarm will sound with 4 seconds
intervals. Now the output is supplied from the battery
source.
5. Connect inlet to the mains again. The indicator “INPUT”
will light on again.
6. Now your UPS is ready for operation. Plug the critical
devices such as computer, disk drive, monitor, printer or
electronic instrument to the UPS output.
1. Pastikan posisi main switch pada posisi off dan tidak ada
beban yang terpasang pada terminal output UPS.
2. Hubungkan kabel input PLN, indikator “INPUT” akan
menyala.
3. Hidupkan main switch, indikator “INVERTER” menyala
dan indikator “BYPASS” menyala ± 20 detik kemudian
akan mati, bersamaan dengan itu indikator baterai level
akan menyala (tergantung kondisi baterai) dan indikator
“INVERTER OUTPUT” akan menyala.
4. Lepaskan kabel input PLN, indikator “INPUT” akan mati
dengan buzzer akan berbunyi setiap 4 detik, berarti UPS
bekerja dengan baterai sebagai sumbernya.
5. Hubungkan lagi kabel input PLN, indikator “INPUT” akan
menyala kembali.
6. Sekarang UPS siap menjalankan fungsinya, hubungkan
peralatan yang sensitif seperti komputer diskdrive, monitor,
printer atau instrument elektronik lainnya ke unit output
UPS.
7
VI. START UP UPS / MENGHIDUPKAN UPS

1. Turn on procedure:
a. Turn on the main switch at front panel.
b. Turn on the power switch on your devices.
2. When utility power interrupted, the UPS can work without
transfer (0 ms) and the audible alarm will sound every 4
seconds. When battery low, the audible will sound every 1
second.
3. Turn off procedure:
a. Turn off all the power switch on your devices.
b. Turn off the main switch at front panel.
Notes:
The UPS battery should charge for at least 10 hours to ensure
sufficient runtime. the unit is being charged whenever it is
connected to utility power.
1. Menghidupkan UPS:
a. Hidupkan main switch pada panel depan.
b. Hidupkan beban yang terpasang pada output.
2. Pada saat tegangan jala-jala mati, UPS akan segera bekerja
tanpa waktu transfer (0 ms) dan buzzer akan berbunyi tiap
4 detik. Pada saat baterai akan habis, buzzer akan berbunyi
tiap 1 detik.
3. Mematikan UPS:
a. Matikan semua beban yang terpasang pada UPS.
b. Matikan main switch pada panel depan.
Catatan:
Baterai UPS harus diisi sekurangnya 10 jam untuk
memastikan UPS beroperasi dengan memadai. Unit akan
mengisi bilamana dihubungkan dengan sumber listrik.
VII. OPERATION PROCEDURE / CARA MENGOPERASIKAN
8

LINE
INPUT
INVERTER
OUTPUT BYPASS FAULT OVER
LOAD
ON
-
-
ON
ON
ON
BUZZER STATUS
CONDITION
RECOMMENDED
SOLUTION
ON
ON
ON
ON
-
-
-
-
-
-
ON
ON
-
-
-
-
-
ON
-
-
-
-
ON
-
-
Every 4 seconds
Every 1 second
Every 4 seconds
Continuous
Continuous
Normal
Utility power failure
Battery will discharge
completely
Rectifier failure
1. UPS not running
2. Overload
1. Inverter failure
-
-
Close your software and
files in use
Call for service
Remove some load from
the UPS
Refer to trouble shooting
guide
9
VIII. TABLE OF INDICATOR STATUS / TABEL STATUS INDIKATOR

SYMPTOM PROBABLE CAUSE RECOMMENDED SOLUTION
“INPUT” and “BYPASS” indicator are
“ON”
“INPUT”, “BYPASS” and “FAULT”
indicator are “ON” and alarm sounds
continuously
1. UPS not running
2. Overload
Inverter failure
1. Turn on the UPS
1. Remove some load from the UPS
2. If it remains the same, call for service
1. Turn off main switch and turn on main switch again
2. If UPS doesn’t recover, call for service
Utility power failure 1. Check utility power is present at wall outlet
2. Otherwise, call for service
“INPUT” indicator is “OFF” and alarm
sounds periodically
1. Recharging the battery by keep the main switch
“ON” for 10 hours
2. Retest the battery discharging again. If it remains
the same, call for service
Batteries discharged completely
No output voltage when input power
fails
Rectifier failure Call for service
“INPUT” and “INVERTER” indicator
are “ON” but alarm sounds
10
IX. TROUBLE SHOOTING / PETUNJUK KETIDAKNORMALAN

SERVICE CENTRE
ICA
Jln. Pinangsia Raya I No: 22BB
Jakarta - 11120
Phone : (021) 6906020 (Hunting)
ICA
Notes :
For further information, please visit “www.icaups.co.id”.
----------------------------------------------------------------------------------
Catatan :
Untuk informasi lebih lanjut, silakan kunjungi “www.icaups.co.id”.
Other manuals for UPS ST Series
3
This manual suits for next models
4
Table of contents
Other ICA UPS manuals