manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ICP DAS USA
  6. •
  7. I/O System
  8. •
  9. ICP DAS USA I-7019R User manual

ICP DAS USA I-7019R User manual

I-7019R, M-7019R Quick Start Guide
Warranty
All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date
of delivery to the original purchaser.
Warning
ICP DAS assumes no liability for damages resulting from the use of this product. ICP DAS reserves the right to change this
manual at any time without notification. The information furnished by ICP DAS is believed to be accurate and reliable.
However, no responsibility is assumed by ICP DAS for its use, or for any infringements of patents or other rights of third
parties resulting from its use.
Packing List
I-7019R or M-7019R
Plastic Rail
CD
Quick Start Guide
Internal I/O Structure
Pin Assignments
Wire Connections
Page 1
Modbus Table (M-7019R only)
Address
Description
R/W
10129 ~
10136
00129 ~
00136
Over/under range status of channel 0
to 7
R
30001 ~
30008
40001 ~
40008
Analog input value of channel 0 to 7
R
30129
40129
CJC temperature in 0.01°C
R
40257 ~
40264
Type code of channel 0 to 7
R/W
40289 ~
40296
Temperature offset of channel 0 to 7
in 0.1°C, valid range: -128 ~ 127
R/W
40353 ~
40360
CJC offset of channel 0 to 7 in 0.1°C.
1 for 0.1, 127 for 12.7, 255 for –0.1,
128 for –12.8
R/W
40481
Firmware version (low word)
R
40482
Firmware version (high word)
R
40483
Module name (low word)
R
40484
Module name (high word)
R
40485
Module address, valid range: 1 ~ 247
R/W
40486
Bits 5:0
Baud rate, 0x03 ~ 0x0A
Code
0x03
0x04
0x05
0x06
Baud
1200
2400
4800
9600
Code
0x07
0x08
0x09
0x0A
Baud
19200
38400
57600
115200
Bits 7:6
00: no parity, 1 stop bit
01: no parity, 2 stop bit
10: even parity, 1 stop bit
11: odd parity, 1 stop bit
R/W
Address
Description
R/W
40488
Modbus response delay time in ms,
valid range: 0 ~ 30
R/W
40489
Host watchdog timeout value, 0 ~
255, in 0.1s
R/W
40490
Channel enable/disable, 00h ~ FFh
R/W
40491
Module CJC offset in 0.01°C
R/W
40492
Host watchdog timeout count, write 0
to clear
R/W
40493
CJC update setting, 0 ~ 2
R/W
00257
Protocol, 0: DCON, 1: Modbus RTU
R/W
00259
Filter setting, 0: 60Hz rejection, 1:
50Hz rejection
R/W
00260
Modbus host watchdog mode
0: same as I-7000
1: can use AO and DO command to
clear host watchdog timeout status
R/W
00261
1: enable, 0: disable host watchdog
R/W
00268
1: enable, 0: disable CJC
R/W
00269
Modbus data format, 0: hex, 1:
engineering
R/W
00270
Host watch dog timeout status, write
1 to clear host watch dog timeout
status
R/W
00272
Write 1 to load factory calibration
parameters
W
00273
Reset status, 1: first read after
powered on, 0: not the first read after
powered on
R
00274
Sampling rate, 1: 8Hz, 0: 10Hz
R/W
00276
Open thermocouple detection, 1:
enable, 0: disable (for firmware
version B307 and later)
R/W
DCON Protocol
Functions
Command
Response
Notes
Read module name
$AAM
!AA(Data)
AA: address number
Read module firmware version
$AAF
!AA(Data)
Read all analog input data
#aa
>(data)
Read analog input data of each channel (<=16 channel)
#aai
>(data)
i: channel number (Hex)
Read analog input data of each channel (>16 channel)
#aaii
>(data)
ii: channel number (Hex)
If you want to know the detail DCON protocol, please check it from CD or web
CD path: \\napdos\7000\manual\
Web: ftp://ftp.icpdas.com/pub/cd/8000cd/napdos/7000/manual/
Page 2
Module test and configuration
Step 1: INIT switch Operation
1. Find out the INIT switch( back of the module),
and turn to INIT.
2. Reboot the module
Step 2: Install & Run DCON Utility
1. Please Install DCON Utility first
You can find the software in the CD.
CD path:
<Driver>:\napdos\driver\dcon_utility\
Web link:
http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/
2. Run DCON utility
Step 3: Set search configuration & search module
Step 4: Select Module for testing and configuration
1. Click “COM Port”
2. Assign the communication information and click
“OK”
Module Default Setting
COM Port
Refer converter Port Number
Baud Rate
9600
Protocol
DCON for I-7000
Modbus RTU for M-7000
Parity Option
N,8,1
3. Click “Search” and select “Start Searching”
Software will search the modules from COM Port
4. Click “Search“ and select “stop searching”
Manual stop when the modules searched
Note:
When no module can be searched, please check the
wire and communication information
Select COM Port Number
Double click “select module”
Page 3
Step 5: Configuration Settings & Channel Settings
Module Settings
Protocol
DCON / Modbus
Address
1~255 (0:INIT)
Baud rate
1200~115200
Parity option
N,8,1
Step 6: Change to normal mode and keep the settings
1. Turn the INIT Switch to Normal.
2. Reboot the module
Trouble Shooting
Q1. How to do when forgot module address or baud rate?
Please turn to INIT mode, and run DCON Utility to search.
The module supports DCON protocol at the INIT mode.
And the address is 0. The communication setting is “9600,N,8,1”.
Q2. How to configure the I-7000 and M-7000 modules?
ICP DAS provide DCON Utility to configure I-7000 and M-7000 modules.
Please download the last version from: http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_utility/
Q3. What is individual channel configuration?
I-7019R/M-7019R provides the “individual channel configuration”.
“Individual channel configuration” means the different settings of the input ranges for each channel.
You can configure the modules by DCON utility
Q4. What is the CJC function?
CJC (Cold-Junction Compensation) offset is for the temperature measurement.
You can set a CJC offset for all channels or each channel in DCON Utility,
Q5. How to programming with I-7000 or M-7000 by C#, VB, VC?
ICP DAS I-7000 and M-7000 series both support DCON protocol. And Only M-7000 series supports Modbus protocol.
For DCON protocol, please download SDK and Demo from:
http://ftp.icpdas.com/pub/cd/8000cd/napdos/driver/dcon_dll_new/
For Modbus protocol, please refer this web link:
http://www.icpdas.com/products/PAC/i-8000/modbus.htm
If there is any other question, please feel free to contact us. Email: ser[email protected]
Website: http://www.icpdas.com.tw/contact_us/contact_us.html
Channel Status
Input Range Settings
CJC offset
Temperature Offset Settings
Page 4

Other manuals for I-7019R

1

This manual suits for next models

1

Other ICP DAS USA I/O System manuals

ICP DAS USA I-9K Series User manual

ICP DAS USA

ICP DAS USA I-9K Series User manual

ICP DAS USA PCI-82x Series User manual

ICP DAS USA

ICP DAS USA PCI-82x Series User manual

ICP DAS USA ISO-P32S32W User manual

ICP DAS USA

ICP DAS USA ISO-P32S32W User manual

ICP DAS USA tM-R5 User manual

ICP DAS USA

ICP DAS USA tM-R5 User manual

ICP DAS USA I-7053 FG User manual

ICP DAS USA

ICP DAS USA I-7053 FG User manual

ICP DAS USA I-7000 Series User manual

ICP DAS USA

ICP DAS USA I-7000 Series User manual

ICP DAS USA WP-5238-CE7 User manual

ICP DAS USA

ICP DAS USA WP-5238-CE7 User manual

ICP DAS USA PCI-D64HU User manual

ICP DAS USA

ICP DAS USA PCI-D64HU User manual

ICP DAS USA PCI-P16C16U User manual

ICP DAS USA

ICP DAS USA PCI-P16C16U User manual

ICP DAS USA I-7018 CR User manual

ICP DAS USA

ICP DAS USA I-7018 CR User manual

ICP DAS USA ISaGRAF VP-2117 User manual

ICP DAS USA

ICP DAS USA ISaGRAF VP-2117 User manual

ICP DAS USA PET-7050 User manual

ICP DAS USA

ICP DAS USA PET-7050 User manual

ICP DAS USA PISO-813 User manual

ICP DAS USA

ICP DAS USA PISO-813 User manual

ICP DAS USA SG-3013 User manual

ICP DAS USA

ICP DAS USA SG-3013 User manual

ICP DAS USA tM-AD2 User manual

ICP DAS USA

ICP DAS USA tM-AD2 User manual

ICP DAS USA IR-712-MTCP User manual

ICP DAS USA

ICP DAS USA IR-712-MTCP User manual

ICP DAS USA CAN-2084C User manual

ICP DAS USA

ICP DAS USA CAN-2084C User manual

ICP DAS USA WF-2000 Series User manual

ICP DAS USA

ICP DAS USA WF-2000 Series User manual

ICP DAS USA PCI-P16R16 Series Mounting instructions

ICP DAS USA

ICP DAS USA PCI-P16R16 Series Mounting instructions

ICP DAS USA I-7530A-MR-FD User manual

ICP DAS USA

ICP DAS USA I-7530A-MR-FD User manual

ICP DAS USA PET-7000 Series User manual

ICP DAS USA

ICP DAS USA PET-7000 Series User manual

ICP DAS USA PCI-P8R8 User manual

ICP DAS USA

ICP DAS USA PCI-P8R8 User manual

ICP DAS USA I-7088 User manual

ICP DAS USA

ICP DAS USA I-7088 User manual

ICP DAS USA PROFI-8455 Setup guide

ICP DAS USA

ICP DAS USA PROFI-8455 Setup guide

Popular I/O System manuals by other brands

Omron C120 System manual

Omron

Omron C120 System manual

Weidmüller WI-I/O 9-U2 MESH I/O manual

Weidmüller

Weidmüller WI-I/O 9-U2 MESH I/O manual

WAGO Modular IO System INTERBUS S user manual

WAGO

WAGO Modular IO System INTERBUS S user manual

Siemens SIMATIC ET 200SP manual

Siemens

Siemens SIMATIC ET 200SP manual

Acromag IOS-EP201 user manual

Acromag

Acromag IOS-EP201 user manual

Pilz PSSu E F BSW operating manual

Pilz

Pilz PSSu E F BSW operating manual

GST DI-M9301 quick start guide

GST

GST DI-M9301 quick start guide

Advantech PCI-1713 user manual

Advantech

Advantech PCI-1713 user manual

Pilz PSSu E S 2AI TC operating manual

Pilz

Pilz PSSu E S 2AI TC operating manual

WAGO I/O SYSTEM 750 manual

WAGO

WAGO I/O SYSTEM 750 manual

Spectrum 1734 user manual

Spectrum

Spectrum 1734 user manual

Measurement Computing PCI-DAS6013 user guide

Measurement Computing

Measurement Computing PCI-DAS6013 user guide

Beckhoff EL3751 Documentation

Beckhoff

Beckhoff EL3751 Documentation

Mitsubishi CL1Y2-T1D2S manual

Mitsubishi

Mitsubishi CL1Y2-T1D2S manual

Assa Abloy OneSystem uP N5951 Installation and mounting instructions

Assa Abloy

Assa Abloy OneSystem uP N5951 Installation and mounting instructions

Sony DVCAM DSBK-140 installation instructions

Sony

Sony DVCAM DSBK-140 installation instructions

Siemens SIMATIC ET 200SP Product information

Siemens

Siemens SIMATIC ET 200SP Product information

M-system R3-SV16N instruction manual

M-system

M-system R3-SV16N instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.