Idem PSA User manual

Non Contact Stand Alone Coded Safety Switches
MAINTENANCE:
Weekly: Check alignment of actuator and look for signs of mechanical damage to the switch casing. Check wiring for signs of damage.
Monthly: Check each switch function by opening and closing each guard individually in turn and ensuring that the Green LE on the switch is illuminated when the switch is closed and
extinguished when the switch is open. Check that the machine stops and cannot be re-started when each switch is open.
Never repair any switch, actuator or integral cables. Replace any switch displaying signs of mechanical damage to the casing or cables.
IMPORTANT NOTE
:
Read and understand these instructions before installing, operating, or maintaining this equipment.
The product is designed to be a component of a customised safety orientated control system. It is the responsibility of each manufacturer to ensure the correct overall functionality of its
systems and machines. I EM, its subsidiaries and affiliates, are not in a position to guarantee all of the characteristics of a given system or product not designed by I EM.
APPLICATION:
Coded Non Contact switches are designed to interlock hinged, sliding or removal guard doors. They are specifically advantageous when:
a) poor guard alignment exists
b) anti-tamper is required
c) high hygiene requirements exist e.g. food industry hose down
d) a long mechanical life is required (no moving or touching parts).
The PSA/MSA Coded Non Contact Switches can be used to provide protection up to Category 4 and Ple to ISO13849-1.
OPERATION:
All Coded Non Contact Safety Switches are designed to conform to EN60947-5-3 (P F-M) and be used as directed by EN1088, EN ISO12100 and EN 60204-1. They have coded
magnetic sensing which provides a wide (>10mm) sensing distance and provides a high tolerance to misalignment after sensing. They can be fitted behind stainless steel fittings and can
operate in extreme environments of temperature and moisture.
INSTALLATION:
Installation of all Coded Non Contact Switches must be in accordance with a risk assessment for the individual application.
The PSA/MSA internally monitor 2 redundant circuits as per ISO13849-1 for up to Ple/Category 4 protection.
M4 mounting bolts must be used to fix the switches. Tightening torque for mounting bolts to ensure reliable fixing is 1.0 Nm. Always mount on to Non Ferrous materials.
The recommended setting gap is 5mm. The Safety switch must not be used as a mechanical stop or be adjusted by striki
ng with a hammer.
The actuator must not be allowed to strike the switch. o not mount adjacent switches or actuators closer than 30mm.
Typical misalignment tolerance after setting is 5mm.
After installation always check each switch function by opening and closing each guard individually in turn and ensuring that the Green LE on the switch and the LE ’s on the Safety
Relay are illuminated when the switch is closed and are extinguished when the switch is open. Check that the machine stops and cannot be re-started when each switch is open.
ACTUATOR OPENING DIRECTIONS: DIMENSIONS:
Align actuator and switch using the target lines. All dimensions in mm.
PSA MSA
O erating Instructions
MSA
PSA
Mirror Polished (Ra4)
Stainless Steel 316

Non Contact Stand Alone Coded Safety Switches
IDEM SAFETY SWITCHES Ltd., 2 Ormside Close, Hindley
Industrial Estate, Hindley Green, Wigan, WN2 4HR UK. Tel: +44 (0)1942 257070 Fax.: +44 (0)1942 257076
IDEM (USA) 4416 Technology Drive, Fremont, CA 94538 Tel:510-445-0751 Fax:1866-431-7064 email: [email protected] Web: www.idemsafety.com
Standards:
ISO14119
IEC60947
-
5
-
3 IEC60947
-
5
-
1
UL508
ISO13849-1 EN62061 EN60204-1
Safety Classification and Reliability Data:
Power Supply
24Vdc +/
-
10% (Consumption 15
0
mA max.)
Safety Output Maximum Rating
24
0Vac/24Vdc
3A
* ac/dc
(*Max. current for QC is 2A)
Auxiliary Output Maximum Rating
24Vdc 0.5A
ielectric Withstand
4k
Vac
Insulator Resistant
100 Mohms
Recommended Setting Gap
5mm
Switching istance
Sao 1
0mm Close
(Target to Time)
Sar 15mm Open
Tolerance to Misalignment
5mm in any direction from 5mm setting gap
Approach Speed
600mm/m to 1000mm/s
Body Material
PSA High Specification Polyester
MSA Stainless Steel 316
Temperature
-
25C/45C
S
hock Resistance
IEC 68
-
2
-
27 11ms 30g
Vibration Resistance
IEC 68
-
2
-
6 10
-
55Hz 1mm
Enclosure Protection
PSA: IP67 MSA: IP69K/IP67
Cable Type
PVC 10 core 7mm O
Mounting Bolts
2 x M4
Quick Connect (QC)
Flying Lead 250mm
M12 8 way Male Plug
(Pin view from switch)
Flying
Lead
Colours
Circuit
2
Red
Supply +24Vdc
24Vdc +/- 10%
3
Blue
Supply 0Vdc
1
White
Safety Output 1 (Force guided relay)
AC15 240Vac 3A*
C13 24Vdc 3A*
7
Black
Safety Output 1 (Force guided
relay)
4
Yellow
Safety Output 2
AC15 240Vac 3A*
C13 24Vdc 3A*
6
Green
Safety Output 2
8
Brown
Reset/Check Circuit
–
Output
Not Used
Orange
Reset/Check Circuit
–
Manual start
5
Pink
Reset/Check Circuit
–
Auto start
Not Used
Grey
Auxi
liary Feed
Electronic +24Vdc 0.5
A
Safety Integrity Level
SIL3
PFH (1/h)
3.95E
-
10
Corresponds
to 4.0% of SIL3
PF
3.46
E
-
05
Corresponds to 3.5
% of SIL3
Proof Test Interval T
1
20a
Performance Level
E
Category
Cat4
MTTF
d
446a
iagnostic Coverag
e C
99% (high)
oc: 1025
45
June 2016
CONNECT
ION EXAMPLE: Switches in series PLe Cat.4
Two switches connected in series to
give dual circuit safety outputs to machine contactors.
Safety Circuit 1 (Black/White) utilises internally checked force guided relay contacts and is
connected in series with the corresponding Safety Circuit 2 (Yellow/Green) of the next
switch.
Allows minimal wiring and higher current switching to K1 and K2 contactors.
A manual start and contactor feedback check is achieved by connecting K1(Aux) and
K2(Aux) feedback contacts and momentary start button through the orange and brown
feedback check.
SAFETY PRECAUTIONS:
1. Installation and commissioning of the device must be performed only
by authorised ersonnel.
2. Observe the country specific regulations when installing the device.
3. The wiring of the device must comply with the instructions in this user
information - otherwise there is a risk that the safety function will be lost.
4. External fusing of the safety contacts (a slow blow or 6A quick action
must be provided).
5. All relevant safety regulations and standards are to be observed.
6. The overall concept of the control system in which the device is
incorporated must be validated by the user.
7. Failure to observe the safety regulations can result in death, serious
injury and serious damage.
8.
Always use Safety Output 1.
To request this data sheet in other languages please contac
t
.
Pour obtenir cette fiche en Français, veuillez contacter inf[email protected].
Para solicitar esta hoja de datos en Español, por favor contacto con info@idemsafety.com.
EC/EU Declaration of Conformity
MANUFACTURER: IDEM SAFETY SWITCHES LIMITED
Hindley Industrial Estate, Hindley Green, Wigan, Lancashire WN 4HR, United Kingdom
THE LISTED DEVICES CONFORM TO THE ESSENTIAL HEALTH AND SAFET REQUIREMENTS OF THE FOLLOWING EUROPEAN DIRECTIVES
AND STANDARDS:
Machinery Directive ( 006/4 /EC)
EMC Directive ( 014/30/EU)
DEVICES: NON CONTACT SAFET SWITCHES:
PSA MSA Standalone Coded Safety Switches
STANDARDS (plus amendments):
EN 60947-5-3 013
EN ISO 13849-1: 008 + AC: 010 + AC: 013
M.Mohtasham Managing Director
1
st
May 2013
Characteristic Data according to IEC62061 (used as a sub system)
Characteristic Data
according to EN ISO13849
-
1
The calculation of the above values is based on the following assumptions:
Number of operating days per year: d
op
= 365d
Number of operating hours per day: h
op
= 24h
Number of operating cycles per day: n
cyc
= 1/d
B10
d
= 150,000 AC1 Load 3A
= 2,000,000 AC1 Load 0.5A
When the product is used deviant from these assumptions (different load,
operating frequency, etc.) the values have to be adjusted accordingly.
*Max. current for Quick Connect is 2A.
Information with regard to UL 508:
Type 1 Enclosures.
Maximum Temperature 45C
Maximum Output 24Vdc 3A
Use Class 2 Supply or equivalent
This manual suits for next models
1
Table of contents
Other Idem Switch manuals
Popular Switch manuals by other brands

Canyon
Canyon DS-4 quick start guide

Cisco
Cisco Catalyst C3850 Series Hardware installation guide

Xylem
Xylem McDonnell & Miller FS4-3T Series instruction manual

MFJ
MFJ MFJ-1272B TNC user manual

ALFAtron
ALFAtron ALF-21E-SOFTCODEC manual

Mellanox Technologies
Mellanox Technologies Mellanox SX1018 Command reference guide