Vacuum Valve for Accessory Port M14
Thread
Product number 47007
Vacuum Valve for Accessory Port M16
Thread
Product number 47008
Product Use & Video Tutorials
http://ikelite.com/watch-47011
Included in the Box
• Vacuum valve
• Vacuum valve plug (attached)
• Seal ring # 0139.02
Important Notices
»Requires a compatible vacuum pump with 1/4” tting
(not included).
»The vacuum pump is not airtight. Do not leave the
vacuum pump attached to your system overnight.
»The vacuum valve is only waterproof with the plug in
place. Never submerge the housing in water without the
plug properly installed in the valve.
»Vacuum systems are only capable of simulating depths
up to 33 feet (10 meters). Some very small leaks, like
those caused by a ne hair across the o-ring, may only
occur at deeper depths. In most cases, these leaks are
not signicant enough to cause damage to a camera.
»A vaccum system cannot correct for improper assembly.
Vacuum
valve
Valve
release
lock
Vacuum plug
Seal ring
Installation
Installing the Valve
1.
Remove the accessory port plug.
2.
Make sure that the seal ring is in place on the valve body.
Do not lubricate the seal ring prior to installation.
3.
Check that the sealing surface and o-ring on the
bulkhead are clean. No lubricant is necessary.
4.
Thread the valve into the housing’s accessory port being
careful not to cross-thread.
5.
Use an 11/16” wrench to carefully tighten down the valve
just until it touches the case. Do not over-tighten.
»It is recommended to run a vacuum test and take the
housing to depth without a camera installed to test for
leaks.
Overnight Check
You are more likely to nd a small leak by checking the
housing after it sits overnight.
Re-attach the vacuum pump and check that the gauge
returns to the same position as when the system was
assembled.
Very small leaks will become more evident on the gauge as
more time passes.
»Do not leave the vacuum pump attached overnight. The
vacuum pump is not designed to hold a vacuum.
Opening the Housing
»The vacuum must be released prior to opening the
housing. It is not possible to open a housing with a
vacuum drawn.
1.
Rinse the housing with fresh water prior to opening.
2.
Press the vacuum valve lock release and remove the
plug from the valve.
3.
Attach the pump to the valve and press the release
button on the pump.
4.
If the pump is not available, insert a small blunt object
into the center of the valve and gently press to allow air to
enter the housing.
Limited Warranty
This Ikelite product is warranted against any manufacturing
defects for a period of one (1) year from the original date
of purchase. To obtain warranty service, the product must
be returned to Ikelite postage paid. Ikelite will, at its sole
discretion, repair or replace such products, and will return
to customer postage paid. All other claims of any nature are
not covered. Except as mentioned above, no other warranty
expressed or implied applies to this Ikelite product.
Contact Us
Ikelite Underwater Systems
50 W 33rd St
Indianapolis, IN 46208 USA
(317) 923-4523
[email protected]

This manual suits for next models

1

Popular Control Unit manuals by other brands

Ingersoll-Rand SRV125F Series Operation and maintenance manual

Ingersoll-Rand

Ingersoll-Rand SRV125F Series Operation and maintenance manual

ABB XIO-08 user manual

ABB

ABB XIO-08 user manual

SEA USER 1 - 24v DG R1 manual

SEA

SEA USER 1 - 24v DG R1 manual

CALEFFI FlowCal 127 Series manual

CALEFFI

CALEFFI FlowCal 127 Series manual

SMC Corporation IL201 series manual

SMC Corporation

SMC Corporation IL201 series manual

Barco HDX 3D installation manual

Barco

Barco HDX 3D installation manual

Miele professional A 300 operating instructions

Miele professional

Miele professional A 300 operating instructions

Leadshine CS2RS Series user manual

Leadshine

Leadshine CS2RS Series user manual

BERGHOF B-Nimis MC-Pi Series user manual

BERGHOF

BERGHOF B-Nimis MC-Pi Series user manual

Burkert 2064 quick start

Burkert

Burkert 2064 quick start

Leadshine Technology M880A user manual

Leadshine Technology

Leadshine Technology M880A user manual

Telit Wireless Solutions FN980 Design guide

Telit Wireless Solutions

Telit Wireless Solutions FN980 Design guide

Toto T60 Installation

Toto

Toto T60 Installation

Emerson E5 instruction manual

Emerson

Emerson E5 instruction manual

Grundfos UPZC-1 Installation and operating instructions

Grundfos

Grundfos UPZC-1 Installation and operating instructions

Leviton VRCS4-1L Vizia RF + installation instructions

Leviton

Leviton VRCS4-1L Vizia RF + installation instructions

pizzato CS AR-24 Series quick guide

pizzato

pizzato CS AR-24 Series quick guide

IMKO SM-USB quick start guide

IMKO

IMKO SM-USB quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.