SMC Corporation IL201 series User manual

EMC.IL201-211-220-01A-UK
Relays/Valves
Lock-Up Valve
Series IL201/211/220

1
Lock-Up Valve
Series
IL
201/211/220
Principle of Operation
IL201 IL211
IL220
Adjusting screw
Spring 8
Valve 2
Piston >
Lower diaphragm B
Lower diaphragm chamber
=
Upper diaphragm @
Upper diaphragm chamber
:
Exhaust port ;
Adjusting spring .
Adjusting screw
Spring 8
Valve 2
Piston >
Lower diaphragm B
Lower diaphragm chamber
=
Upper diaphragm @
Upper diaphragm chamber
:
Exhaust port ;
Adjusting spring .
Adjusting screw
Spring 8
Valve 2
Piston >
Lower diaphragm B
Lower diaphragm chamber
=
Upper diaphragm @
Upper diaphragm chamber
:
Exhaust port ;
Adjusting spring .
OUT1
OUT2
SIG
IN1
IN2
SIG
IN OUT
OUT
SIG
IN1
IN2
Model IL201 IL211 IL220
Action Single acting Double acting 3 Port
Signal pressure Max. 1.0 MPa Note 1)
Set pressure range 0.14 to 0.7 MPa Note 1)
Shut-off pneumatic circuit pressure
Max. 0.7 MPa
Ambient and fluid temperature
-5 to 60 °C
Port size Rc 1/4
Differential Note 2) 0.01 MPa
Weight 0.45 kg 0.64 kg 0.7 kg
Note 1) Provide a differential pressure of 0.1 MPa or more
between the signal pressure and set pressure.
If the differential pressure is small, the internal part
is worn out due to the structure of this product and
the bleed amount from the exhaust port increases,
which may affect the characteristics.
Note 2) Pressure difference between lock activated and lock
released
¡The lock-up valve is used if any air source or air supply piping line failure occurs in the
air operated process control line.
Single acting, Double acting: Retains pressure at the operating area as emergency operation until the air
source is recovered to its normal state.
3 Port: Changes the supply port if a trouble occurs.
IL 02
Accessories
—None
BWith bracket
Suffix
—Standard
T
High temperature (-5 to 100 °C)
L
Low temperature (-30 to 60 °C)
SExternal parts copper-free
ST
External parts copper-free/
High temperature (-5 to 100 °C)
SL
External parts copper-free/
Low temperature (-30 to 60 °C)
Port size
02 1/4
Thread type
—Rc
NNPT∗
FG∗
∗Semi-standard
Action
201 Single acting
211 Double acting
220 3 Port
201
How to Order
The signal air pressure enters the upper diaphragm
chamber qto generate a force. When this force is
larger than the force generated by compressing the
adjusting spring e, the upper diaphragm wis
pushed up, the exhaust port ris closed, and the
signal air pressure enters the lower diaphragm
chamber tand acts the lower diaphragm y. This
pushes down the piston uto open the valve.
IL201 and IL211 enter the status, in which the flow
path between IN and OUT is opened. IL220 enters
the status, in which the flow path between IN1 and
OUT is opened. If the signal air pressure drops to a
level below the set pressure for some reason, the
upper diaphragm wis pushed down, the pressure
inside the lower diaphragm tis exhausted from
the exhaust port r, and the valve iis closed by
the force of the spring o. At this time, IN and OUT
are shut down in IL201 and IL211. In IL220, IN1
and OUT are shut down, and the flow path between
IN2 and OUT is opened. The set pressure is
adjusted with the adjusting screw !0.
Thread port
—Rc (PT)
EG (PF)

2
Lock-Up Valve Series IL201/211/220
Component Parts
No. Description Material Note
1 Body Aluminium alloy Silver baking finish
2 Pilot body Aluminium alloy Silver baking finish
3 Bonnet Aluminium alloy Silver baking finish
4 Adjusting screw Stainless steel
5 Piston Brass
6 Piston rod Brass
7
Diaphragm assembly
Aluminium alloy/Brass/NBR
Chromated
8 Diaphragm NBR
9 Piston valve Brass/NBR
10 Piston valve Brass/NBR
11 Valve Brass/NBR
12 Adjusting spring Steel wire Zinc chromated
13 Valve spring Stainless steel
14 Valve spring Stainless steel
15 Piston spring Stainless steel
16 O-ring NBR
17 O-ring NBR
18 O-ring NBR
19 O-ring NBR
20 O-ring NBR
21 O-ring NBR
22 O-ring NBR
Replacement Parts
Model Order no. Contents
IL201 KT-IL201 Set of left nos. u, i, o, !2, !3, !6, !7, !8, !9
IL211 KT-IL211 Set of left nos. u, i, o, !0, !2, !3, !6, !7, !8, !9
IL220 KT-IL220 Set of left nos. u, i, !1, !2, !4, !5, !9, @0, @1, @2
OUT1
OUT2
IN1
IN2
OUTIN1
IN2
IN OUT
.
>
.
>
@
2
:
8
;
@
B
2
:
:
;
=.
>
@
2
:
:
8
;
=
2
12
1
Construction
IL211IL201
IL220

3
Series IL201/211/220
Dimensions
IL201
IL220
IL211
OUT
OUT
SIG
OUT1
OUT2
IN1
IN2
SIG
2 x Ø 6.6
58
45
137
6231
21
5
Ø 60
Ø 2
5 x Rc 1/4
52 10
2
Panel
35
Max. 4
Panel fitting dimension
Ø 14.5
OUTIN1
IN2
SIG
Ø 60
4 x Rc 1/4
≈130
57 10
Ø 2
2
Panel
35
18
3015
2 x Ø 6.6
45
58
Max. 4
Panel fitting dimension
Ø 14.5
OUT
Panel fitting dimension
SIG
52
Ø 2
10
2
Panel
35
3 x Rc 1/4
Ø 60
62
21
5
105
58
45
2 x Ø 6.6
IN OUTSIG
Ø 14.5
Max. 4


Lithuania +370 5 2308118 www.smclt.lt [email protected]
Netherlands +31 (0)205318888 www.smcpneumatics.nl [email protected]
Norway +47 67129020 www.smc-norge.no [email protected]
Poland +48 222119600 www.smc.pl [email protected]
Portugal +351 226166570 www.smc.eu [email protected]
Romania +40 213205111 www.smcromania.ro [email protected]
Russia +7 8127185445 www.smc-pneumatik.ru [email protected]
Slovakia +421 (0)413213212 www.smc.sk [email protected]
Slovenia +386 (0)73885412 www.smc.si [email protected]
Spain +34 902184100 www.smc.eu [email protected]
Sweden +46 (0)86031200 www.smc.nu [email protected]
Switzerland +41 (0)523963131 www.smc.ch [email protected]
Turkey
+90 212 489 0 440
UK
+44 (0)845 121 5122
Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
SMC CORPORATION
Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362
1st printing TT printing TU 00 Printed in Spain
Austria +43 (0)2262622800 www.smc.at [email protected]
Belgium +32 (0)33551464 www.smcpneumatics.be [email protected]
Bulgaria +359 (0)2807670 www.smc.bg [email protected]
Croatia
Denmark +45 70252900 www.smcdk.com [email protected]
Estonia +372 6510370 www.smcpneumatics.ee [email protected]
Finland +358 207513513 www.smc.fi [email protected]
France +33 (0)164761000 www.smc-france.fr [email protected]
Germany +49 (0)61034020 www.smc.de [email protected]
Greece +30 210 2717265 www.smchellas.gr [email protected]
Hungary +36 23511390 www.smc.hu [email protected]
Ireland +353 (0)14039000 www.smcpneumatics.ie [email protected]
Italy +39 0292711 www.smcitalia.it [email protected]
Latvia +371 67817700 www.smclv.lv [email protected]
Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
SMC Corporation (Europe)
1. The compatibility of the product is the responsibility of the person
who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its
compatibility with specific equipment must be decided by the person who designs the
equipment or decides its specifications based on necessary analysis and test results.
The expected performance and safety assurance of the equipment will be the
responsibility of the person who has determined its compatibility with the product. This
person should also continuously review all specifications of the product referring to its
latest catalogue information, with a view to giving due consideration to any possibility of
equipment failure when configuring the equipment.
2. Only personnel with appropriate training should operate machinery
and equipment.
The product specified here may become unsafe if handled incorrectly. The assembly,
operation and maintenance of machines or equipment including our products must be
performed by an operator who is appropriately trained and experienced.
3. .Do not service or attempt to remove product and
machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be performed
after measures to prevent falling or runaway of the driven objects have been
confirmed.
2. When the product is to be removed, confirm that the safety measures as mentioned
above are implemented and the power from any appropriate source is cut, and read
and understand the specific product precautions of all relevant products carefully.
3. Before machinery/equipment is restarted, take measures to prevent unexpected
operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety
measures if the product is to be used in any of the following
conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in
a place exposed to direct sunlight.
2. Installation on equipment in conjunction with atomic energy, railways, air navigation,
space, shipping, vehicles, military, medical treatment, combustion and recreation, or
equipment in contact with food and beverages, emergency stop circuits, clutch and
brake circuits in press applications, safety equipment or other applications unsuitable
for the standard specifications described in the product catalogue.
3. An application which could have negative effects on people, property, or animals
requiring special safety analysis.
4.Use in an interlock circuit, which requires the provision of double interlock for possible
failure by using a mechanical protective function, and periodical checks to confirm
proper operation.
Warning Limited warranty and Disclaimer/
Compliance Requirements
The product used is subject to the following “Limited warranty and
Disclaimer” and “Compliance Requirements”.
Read and accept them before using the product.
1. The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing
industries.
If considering using the product in other industries, consult SMC beforehand and exchange
specifications or a contract if necessary.
If anything is unclear, contact your nearest sales branch.
Caution
SMC products are not intended for use as instruments for legal
metrology.
Measurement instruments that SMC manufactures or sells have not been qualified by
type approval tests relevant to the metrology (measurement) laws of each country.
Therefore, SMC products cannot be used for business or certification ordained by the
metrology (measurement) laws of each country.
Caution
Limited warranty and Disclaimer
1.The warranty period of the product is 1 year in service or 1.5 years
after the product is delivered, wichever is first.∗2)
Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
2.
For any failure or damage reported within the warranty period which is clearly
our responsibility, a replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any
other damage incurred due to the failure of the product.
3.
Prior to using SMC products, please read and understand the warranty
terms and disclaimers noted in the specified catalogue for the particular
products.
∗2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum
pad or failure due to the deterioration of rubber material are not covered by the limited
warranty.
Compliance Requirements
1.
The use of SMC products with production equipment for the manufacture of
weapons of mass destruction (WMD) or any other weapon is strictly
prohibited.
2.
The exports of SMC products or technology from one country to another are
governed by the relevant security laws and regulations of the countries
involved in the transaction. Prior to the shipment of a SMC product to
another country, assure that all local rules governing that export are known
and followed.
These safety instructions are intended to prevent hazardous situations and/or
equipment damage. These instructions indicate the level of potential hazard with the
labels of “Caution,” “Warning” or “Danger.”They are all important notes for safety
and must be followed in addition to International Standards (ISO/IEC)∗1), and other
safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
(Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots - Safety.
etc.
Caution indicates a hazard with a low level of risk
which, if not avoided, could result in minor or moderate
injury.
Warning indicates a hazard with a medium level of risk
which, if not avoided, could result in death or serious
injury.
Caution:
Warning
:
Danger : Danger indicates a hazard with a high level of risk
which, if not avoided, will result in death or serious injury.
Safety Instructions
This manual suits for next models
2
Table of contents
Other SMC Corporation Control Unit manuals

SMC Corporation
SMC Corporation VNA1 series User manual

SMC Corporation
SMC Corporation IL211 Series User manual

SMC Corporation
SMC Corporation VT315 User manual

SMC Corporation
SMC Corporation EX250-SCN1 Manual

SMC Corporation
SMC Corporation EX260-SPN1 User manual

SMC Corporation
SMC Corporation VT307 Series User manual

SMC Corporation
SMC Corporation ASP-X369 Series User manual

SMC Corporation
SMC Corporation EX260-SIL1-X207 User manual