INETVU® MOBILE SYSTEM QUICK START –COMTECH
C-COM Satellite Systems Inc. Page 6
1.4 Installation Overview
CDM-600L:
1. If you are using an Ethernet connection between the 7710 Controller, PC and CDM-600L Satellite
Modem:
a. Power on the CiM-25 Adapter
b. Ensure you are using a crossover network cable to connect using the ‘REMOTE’ Port.
c. Set 7710 to the same network as the CDM-600L.
2. If you are using a Serial connection between the 7710 Controller, PC and CDM-600L Satellite
Modem:
a. Connect to the ‘REMOTE’ Port using a NULL Modem Male to Female Serial Cable
3. Using the front panel interface on the CDM-600L Satellite Modem, press ENT to enter the Main
Menu. Select CONFIGURATION, then REMOTE, then REMOTE again.
4. Verify that the BAUD RATE is 4800 or 9600 and that PARITY is N-8-1.
5. Press CLR until you are back to the Main Menu.
CDM-570L:
1. If you are using an Ethernet connection between the PC and CDM-570L Satellite Modem:
1. Connect a cross-over network cable to the ‘10/100 ETHERNET’ Port
2. Ensure you have set the CDM-570L Remote to ‘ETHERNET’.
3. Set PC to the same network as the CDM-570L.
2. If you are using a Serial connection between the PC and CDM-570L Satellite Modem:
1. Connect to the ‘REMOTE’ Port using a Male to Female Null Modem Serial Cable
2. Ensure you have set the CDM-570L Remote to ‘SERIAL’ and 9600 bps.
3. Start and configure iNetVu® Mobile Software.
4. Verify software, iNetVu® Controller firmware and Modem firmware versions.
5. Determine from NOC the Transmit and Receive Polarization and adjust hardware/software (if
required)
6. Conduct iNetVu® System configuration verification test.