Inficon BM1000 Series User manual

Type designation
Product description
Catalog no.
Document no.
560-315, 560-316
560-317, 560-318
jiqb10en1-05 (1509)
TRANSLATION OF THE ORIGINAL
OPERATING INSTRUCTIONS
BM1000
Bus module
PROFIBUS, PROFINET, DEVICENET, ETHERNET/IP

2
Reprint, translation and duplication need to be approved in writing by
INFICON GmbH.

Content 3
Content
1 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.1 Target groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2 Other applicable documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 Presentation of information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3.1 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3.2 Text markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Owner requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.3 Operator requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Shipment, transport, storage . . . . . . . . . . . . . . . . . . . . . 7
4 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1 Construction of the bus module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.2 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.3 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.3.1 Mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.3.2 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.3.3 Ambient conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5 Installation and removal . . . . . . . . . . . . . . . . . . . . . . . . 10
5.1 Mount the bus module on the DIN-TS35 top hat rail . . . . . . . . . . . . . 10
5.1.1 Establish connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.2 Remove the bus module from the DIN-TS35 top hat rail . . . . . . . . . . 11
6 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.1 EC Declaration of Incorporation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

4About this manual
1 About this manual
1.1 Target groups
This installation manual is intended for the owner and for technically qualified
personnel with experience in leak detection technology and integration of leak
detection devices in leak detection systems. In addition, the installation and use of
the unit require knowledge of electronic interfaces.
1.2 Other applicable documents
1.3 Presentation of information
1.3.1 Warnings
– Operating instructions of the connected leak detector
– Interface protocols, document no. jira54
Imminent threat of danger resulting in death or severe injuries
Dangerous situation potentially resulting in death or severe injuries
Dangerous situation resulting in minor injuries
Dangerous situation resulting in damage to property or the environment

About this manual 5
1.3.2 Text markings
Marking Meaning
Requirement for execution of an action
Tool or aid for an action
►Instruction
1, 2, 3, ... Several instructions in a fixed order
Result of an action

6Safety
2Safety
2.1 Intended use
The bus module is a device interface between e.g. the MSB box of the mass
spectrometer module LDS3000 and an external controller.
►Install, operate and service the unit only in compliance with these instructions.
►Comply with the limits of application (see chapter 4.2, page 8).
2.2 Owner requirements
Safety conscious operation
►Operate and install the unit only if it is in perfect working order and as intended,
in a safety-conscious manner and fully aware of dangers, in compliance with
these instructions.
►Fulfill and ensure compliance with the following regulations:
– Intended use
– Generally applicable safety and accident prevention regulations
– International, national and local standards and guidelines
– Additional provisions and regulations that are specific to the unit
►Use only original parts or parts approved by the manufacturer.
►Keep this manual available at the operating site.
Personnel qualifications
►All work must be performed only by technical specialists who have been trained
on the unit.
►Allow personnel in training to work with the unit only under the supervision of
technical specialists.
►Make sure that the authorized personnel have read and understood these
instructions and all other applicable documents (see chapter 1.2, page 4),
especially the information on safety, maintenance and repairs, before starting
work.
►Define responsibilities, authorizations and supervision of personnel.
2.3 Operator requirements
►Read, observe and follow the information in these instructions and the working
instructions created by the owner, especially the safety instructions and warnings.
►Perform all work based on the complete instructions.

Shipment, transport, storage 7
3 Shipment, transport, storage
Check the scope of
delivery
►Please check the scope of delivery of the product for completeness after receipt.
Transport
Storage ►Always store the unit in compliance with the technical data, see chapter 4.3,
page 9.
Article Quantity
Bus module 1
Installation manual 1
Damage due to unsuitable packaging material
Transport in unsuitable packaging material can damage the unit.
►Transport the unit only in the original packaging material.
►Keep original packaging material.

8Description
4 Description
4.1 Construction of the bus module
aConnection for the cable to the leak detector (LD)
bStatus LED Lights up green when the operating voltage is applied to the bus module.
4.2 Function
The bus module is a device interface between e.g. the MSB box of the mass
spectrometer module LDS3000 and an external controller. The bus module works
according to the PROFIBUS and PROFINET standard.
Fig. 1 Front view
a
b

Description 9
4.3 Technical data
4.3.1 Mechanical data
4.3.2 Electrical data
4.3.3 Ambient conditions
Dimensions (W x H x D) 107.6 mm x 89.7 mm x 76.6 mm
Weight 500 g
Supply voltage 24 V DC
Permissible ambient temperature (during
operation)
10 °C ... 45 °C
Permissible storage temperature -20 °C ... 60 °C
Max. relative humidity up to 31 °C 80%
Max. relative humidity from 31 °C to 40 °C decreasing linearly from
80% to 50%
Max. relative humidity above 40 °C 50%
Protection class IP20
Pollution degree II
Max. altitude above sea level 2000 m

10 Installation and removal
5 Installation and removal
5.1 Mount the bus module on the DIN-TS35 top hat rail
1Hook unit on top hat rail at bottom.
2Press unit onto top hat rail at top.
5.1.1 Establish connections
Connect the bus module with the leak detector
The bus module communicates via data cable with the leak detector and is supplied
with voltage by the data cable.
INFICON data cable
1Connect bus module (connection LD) via data cable with the leak detector.
2Connect the bus module with the external controller by means of the built-in
fieldbus module.
The bus module is activated in the leak detector, e.g. the MSB box of the LDS3000,
see leak detector manual.
Communication with fieldbus master
►Information about establishing communication with the fieldbus master: see
interface protocols, jira54 and kirb43.
Fig. 2 Mounting of bus module

Installation and removal 11
5.2 Remove the bus module from the DIN-TS35 top hat rail
1Use the flat-tip screwdriver to pull out the locking device.
2Pull the device off of the top hat rail.
Fig. 3 Removing the bus module

12 Disposal
6 Disposal
The unit can be disposed of by the owner or sent to INFICON.
The unit is made of materials that can be reused. You should use this option to avoid
waste and save the environment.
►For disposal, always comply with local and regional environmental and safety
regulations.

Appendix 13
7 Appendix
7.1 EC Declaration of Incorporation

INFICON GmbH, Bonner Strasse 498, D-50968 Cologne, Germany
UNITED STATES TAIWAN JAPAN KOREA SINGAPORE GERMANY FRANCE UNITED KINGDOM HONG KONG
Visit our website for contact information and other sales offices worldwide. www.inficon.com
Document: jiqb10en1-05 (1509)
Other manuals for BM1000 Series
1
This manual suits for next models
4
Table of contents
Other Inficon Control Unit manuals