The Innovative Marine HELIO Universal Controller provides aquarium
hobbyists the industry’s premium cutting edge heating temperature
control technology with multi-phase redundant safety. Complimented
with a titanium sensor to better regulate and assure overheating does
not occur while staying within consistent preset temperature
parameters.
Say hello to the HELIO Universal Controller.
The HELIO Controller houses a circuit board processor which is the
heart and mastermind of the controller. By continuously constructing a
bevy of temperature readings from the controller and titanium sensor,
there is constant communication verifying and ensuring temperature
accuracy. The result is when a temperature dierence is detected, there
is an immediate cease of power to the jacks, plus an audible notication
that your aquarium ecosystem is not at a consistent optimal operating
temperature.
Table of Contents Introduction
Introduction.......................................................................................................... 3-4
Read Me.................................................................................................................. 5-6
Warnings..................................................................................................................... 7
Parts List...................................................................................................................... 8
Controller Specications........................................................................................9
Set Up
Set Up & Installation.........................................................................10-11
Remote Sensor Placement.............................................................12-13
Key Operation
How to Set Temperature...................................................................... 14
How to Calibrate Temperature........................................................... 15
How to Set High Alarm......................................................................... 16
How to Set Low Alarm.......................................................................... 17
Error Codes....................................................................................................... 18-19
Maintenance.......................................................................................................... 20
2 3

The HELIO smart controller bridges the gap between hobby grade and
commercial controllers. Its processor goes hand in hand with the
titanium sensor to keep your temperature readings stable.
The controller comes tted with a titanium remote temperature sensor
and dual heating power lines. If the heating element/s of your choosing
have their own controlling systems, you can create up to four
independent temperature readings... Safety in redundancy.
The two power jacks accommodate up to 1000 watts in total for the
heating elements that you choose to attach to the controller. A quick
disconnect junction for the controller’s titanium temperature sensor
make for easy maintenance and upgradeability.
After years in development, the HELIO controller helps you attain the
optimal homeostatic reef aquarium temperature environment. Three
main objectives met: Increased safety. Improved reliability. Providing a
new reef aquarium heating technology superior to the long held
standard.
HELIO Universal Controller.
Safe. Stable. Smart.
NOTES:
- Controller does not come with heating elements or heater holders.
- Maximum of 1000 watts in total can be plugged into the two
controller’s power jacks.
WARNING: Follow the warnings below otherwise death or serious
injuries may result.
To avoid electric shock, special care should be taken since water is
employed in the use of aquarium equipment. For each of the following
situations, do not attempt to repair yourself. Return the appliance to
Innovative Marine for service or discard the appliance.
If the controller falls into water, DO NOT reach for it! First, unplug it and
then retrieve it. If the electrical components of the appliance gets wet,
unplug the appliance immediately.
Carefully examine the appliance after installation. It should not be
plugged in if there is water on parts not intended to be wet.
Do not operate any appliance if it has a damaged cord or plug, or if it is
malfunctioning or if it is dropped or damaged in any manner.
To avoid the possibility of the appliance plug or receptacle getting wet,
position aquarium to one side of a wall mounted receptacle to prevent
water from dripping onto the receptacle plug. A “Drip Loop”should be
arranged by the user for EACH cord connecting an aquarium appliance
to a receptacle. The “Drip Loop” is that part of the cord below the level
of the receptacle or the connector if an extension cord is used. This
“Drip Loop”prevents water traveling along the cord and coming in
contact with the receptacle. If the plug or the receptacle do get wet,
DO NOT unplug the cord. Disconnect the fuse to the circuit breaker
that supplies power to the appliance. Then unplug and examine for the
presence of water in the receptacle.
Close supervision is necessary when any appliance is used by or near
children.
To avoid injury, do not contact hot parts of the heating element(s).
Introduction
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS BEFORE OPERATION
Read MeIntroduction
4 5

Do not operate remote sensor outside of water.
Remote sensor must be cleaned every 30 days or as needed.
Remote sensor must be placed in an area with good water
ow.
Remote senosr must not be placed behind any kind of
ornament.
Follow all manufacturer guides on heating element(s) usage.
HELIO Universal Smart Controller must be away from water.
Unplug the HELIO Universal Smart Controller for 1 hour prior to
a water change.
For indoor aquarium use only.
Keep out of reach of children and pets.
Strong magnets. Can be harmful to pacemaker wearers and
others with medical implants. Keep tools and other metal
objects away.
Controller does not come with heating elements nor heater holders.
You must follow the manufactures heating element manuals for use
and placement.
Always unplug an appliance from the outlet when not in use, before
putting on or taking o parts, and before cleaning. Never yank the cord
to pull plug from the outlet. Before any type of maintenance or trouble
shooting, grasp the plug and pull to disconnect.
Do not use an appliance for other than intended use. The use of
attachments not recommended or sold by the appliance manufacturer
may cause an unsafe condition.
Do not install or store the appliance where it will be exposed to the
weather or temperatures below freezing.
Make sure an appliance mounted on a tank is securely installed before
operating it.
Read and observe all the important notices on the appliance.
If an extension cord is necessary, a cord with a proper rating should be
used. A cord rated for less amperesor watts than the appliance rating
may overheat. Care should be taken to arrange the cord so that it will
not be tripped over or pulled.
ONLY FOR POLARIZED ATTACHMENT PLUG APPLIANCES
If this appliance has a polarized plug (one blade is wider than the other)
as a safety feature, this plug will t in a polarized outlet only one way. If
the plug does not t fully in the outlet, reverse the plug. If it still does
not t, contact a qualied electrician. Never use with an extension cord
unless plug can be fully inserted. Do not attempt to defeat this safety
feature.
SAVE THESE INSTRUCTIONS
SAFETY WARNINGS
Read Me Warnings
DO NOT
BLOCK
6 7

1 x HELIO Universal Controller
1 x Remote Sensor
1 x Remote Sensor Magnetic Holder
1 x Remote Sensor Holder
1 x 100W PTC Titanium Element
830000
830002
830007
830007
830003
1
2
3
4
5
Parts List - HELIO Universal Controller (83000) HELIO Universal Controller - Specifications
1 2
3
5
8 9
Item Code
M
+
-
(Front View)
(Right Side View)
Audible Alarm On
Audible Alarm O
Power Indicator
Element Indicator Line One
Element Indicator Line Two
Mode Button
Increase Temperature
Decrease Temperature
Audible Alarm Toggle
Switch On/O
Factory Preset Temperature
Factory Preset Low Alarm
Factory Preset High Alarm
Temp Set Range
Low Alarm General Range
Low Alarm Minimum Range
High Alarm General Range
High Alarm Minimum Range
Accuracy
Resolution
Calibration Range
77° F
74° F
80° F
59° - 95° F
57° - 93° F
-2° F from Set Temperature
60° - 96° F
+1° F from Set Temperature
< ±1° F
0.1° F
± 9° F
Set Temperature
Aquarium Temperature

Set Up and Installation Set Up and Installation
Attaching the Remote Sensor
Warning: Controller must be unplugged
during attachment and placement of
remote sensor and heating element(s).
If applicable, connect the second
heating element to this plug.
Connect the heating element to this
plug.
Attach sensor to the magnetic holder.
Attach the magnetic backing to secure
the sensor in your aquarium.
Magnetic holder strength up to 1/2”thick
Connect remote sensor to this plug.
Attach Remote Sensor to Holder
10 11
11
2
1
2
3
2
Attach the Remote Sensor
Attach heating element
Attach second heating element
12 3
*Note: Controller does not come
with heating elements or
heating element magnet holders.

Remote Sensor Placement Remote Sensor Placement
AIO Placement Sump Placement
12 13
water line
Rear view of an AIO
*Follow Manufacturer guidelines
for heating element placement
Interior view of a sump
water line
*Follow Manufacturer guidelines
for heating element placement

How to Set Temperature [SET] How to Calibrate Temperature [CAL]
Set desired temperature by pressing the“+”
or “-” button. You can increase or decrease
your desired temperature by 1.0° F.
Temp Set Range: 59° F - 95° F
Wait 3 seconds, then your set temperature
will be automatically saved.
Set desired calibration by pressing the“+”
or “-” button. You can increase or decrease
your desired calibration by 0.1° F
increments.
Temp Set Range: ±9° F
Wait 3 seconds, then your calibrated
temperature will be automatically saved.
M
+
-
Mode Button
Increase Temperature
Decrease Temperature
M
+
-
Mode Button
Increase Temperature
Decrease Temperature
Set Desired Temperature
Temperature
Press the Mode button 1 time then the
display will read .
Plug in controller to receptacle
Press the Mode button 2 times then the
display will read .
Calibrate the Sensor
Calibrate Sensor Temperature
14 15

Set desired high alarm by pressing the “+” or “-”
button. You can increase or decrease your
desired temperature by 1.0°F.
High alarm general range: 60° - 96° F
High alarm minimum range: +1°F from set
temp.
Wait 3 seconds then your set temperature will
be automatically saved.
Set desired low alarm by pressing the “+” or “-”
button. You can increase or decrease your
desired temperature by 1.0°F.
Low alarm general range: 57° - 93° F
Low alarm minimum range: -2°F from set temp.
Wait 3 seconds then your set temperature will
be automatically saved.
How to Set High Alarm [Hi] How to Set Low Alarm [LOW]
M
+
-
Mode Button
Increase Temperature
Decrease Temperature
M
+
-
Mode Button
Increase Temperature
Decrease Temperature
Press the Mode button 3 times then the
display will read .
Set High Alarm
Set Temperature
Press the Mode button 4 times then the
display will read .
Set Low Alarm
Set Temperature
16 17

E1
E3
E4
E7
E5
E6
E7
Remote Sensor Not Communicating
High Temperature Alarm
Low Temperature Alarm
Remote Sensor Error
Element (II) Error
Remote Sensor Error
Error Codes Error Codes
Error Code Quick Guide
E1 : Remote Sensor Not Communicating
The remote sensor is not connected. Check the
connection between the controller and the remote
sensor.
E3 : High Temperature Alarm
The aquarium’s water temperature has exceeded the
high temperature set point.
E4 : Low Temperature Alarm
The aquarium’s water temperature has subceeded
the low temperature set point.
E7 : Remote Sensor Error
Remote sensor has been detected to be out of water
or a sudden temperature swing.
Caution: Controller must be unplugged to avoid
electrical shock or re prior to attempting to
connect sensor or element cables.
Press any button to disengage visual or audible
alarm.
18 19
1
12 3
WARNING: ALWAYS FOLLOW OTHER
MANUFACTURERS HEATING ELEMENT
GUIDE FOR USAGE AND PLACEMENT.
INNOVATIVE MARINE IS NOT
RESPONSIBLE FOR MISUSE, FAILURES, OR
ANY DAMAGES OR RELATED DAMAGES
CAUSED BY OTHER MANUFACTURERS
HEATING ELEMENTS.

Maintenance Notes
In order to keep the HELIO remote sensor working optimally, it must be
free of mineral deposits and needs to be cleaned every 30 days or as
needed.
Unplug the HELIO Universal Controller for at least 1 hour before
cleaning.
Soak the and sensor in a solution of 1 part vinegar to 1 part water for an
hour (or as needed). DO NOT soak the connectors in the cleaning
solution.
Then gently wipe the sensor with a sponge or towel to remove any
excess cleaning solution.
Let the sensor dry before placing it back into your aquarium.
20 21
To Clean the HELIO

www.innovative-marine.com
warranty@innovative-marine.com | 866-368-7941
Table of contents
Popular Controllers manuals by other brands

Regada
Regada MO 3.4 Installation, service and maintenance instructions

Sensus
Sensus 143-80 Series Installation and maintenance instructions

Digital Dream
Digital Dream DM500T3 user manual

REMKO
REMKO EFS Series Operating and installation instructions

Matrix
Matrix COSEC Panel quick start

ICT
ICT Protege WX Configuration guide