Interlogix ACL800SUW-BS User manual

© 2018 United Technologies Corporation. P/N 1073505A• REV 00.00 • ISS 4JUL18
Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved.
ACL800SUW-BS - Biometric Swipe Wiegand
Reader - Installation Manual
Description / Operation
ACL800SUW-BS is a Wiegand biometric reader for access
control applications. It offers storage up to 100 fingerprints and
has a programmable Wiegand output (26 to 80 bits).
Configuration of the readers and fingerprint enrollment is done
through the ACL800 BioManager software.
Connection between the biometric readers is RS485 and it is
used for fingerprint transfer and configuration.
The connection between the biometric readers and the PC is
done through a ACL800FL-CONV-W converter (RS485 to
TCP/IP). Only one converter is needed per system and
supports up to 31 biometric readers
The sensor incorporates dedicated sensing hardware to
facilitate the detection of “spoofing” attacks based on fake
fingers. This data is embedded into the image data stream,
and is processed on the processor. The system is capable of
detecting and defeating well-known fake finger mechanisms,
such as molded “gummy” fingers.
The coating on the surface of the swipe sensor provides
protection from scratching and abrasion due to normal contact
with fingertips and any incidental contact with fingernails.
Specifications
Fingerprint capacity
Up to 100 fingerprints
Technology
Biometry
Authentication
Finger
Fingerprints per user
1-10 fingerprints
Interface
Wiegand 24 to 80 bits; default: Wiegand 26bit
Protocol programming
By ACL800 BioManager software
Wiegand Cable
distance
50 m
Fingerprint Sensor
Type
Swipe capacitive
1:1000 identification
time
970 msec, including feature extraction time
Fingerprint enrolment
On the reader or from the USB desktop reader
Green and Red LED
Externally controlled
Orange LED
Idle mode
Buzzer ON/OFF
Yes
Backlight ON/OFF
Yes
Tamper
Yes
Current requirements
100 mA at 12 VDC
IP Rating
65
Supply voltage
9 to 14 VDC
Operating
Temperature
Relative humidity
−20 to +50°C
5 to 93% noncondensing
Dimensions (mm)
92 x 51 x 25 (metal); 92 x 51 x 27 (ABS)
Mounting
Figure 1: Mounting instructions
•Do not install the device and cabling close to a source of
strong electro-magnetic fields like radio-transmitting antenna.
•Do not place the device near or above heating
equipment’s.
•If cleaning, do not spray or splash water or other cleaning
liquids but wipe it out with smooth cloth or towel.
•Do not let children touch the device without supervision.
•Note that if the sensor is cleaned by detergent, benzene or
thinner, the surface will be damaged and the fingerprint can't
be entered.
If the biometric reader is installed and used in outdoor
environments, the reader MUST be fitted with a weather
protection cover in order to protect the sensor from direct
rainfall. The operating temperature of the product is between -
20 to + 50ºC. If the reader is installed in an environment where
the temperature can drop below -10ºC or/and if the sensor
could only be exposed to direct sunlight, it is strongly
recommended to install the reader inside a third party sealed
wall mount box (fitted with additional heater if very low
temperature) to keep a constant sensor level performance. We
cannot guarantee the functionality of the product if the
recommendations and advice are not followed.

2 / 7 P/N 1073505A• REV 00.00 • ISS 4JUL18
Wiring
Figure 2: Wiring
Wiring description
Connecting biometric readers to controllers
Figure 3: Wiring instructions
•Connect the lines D0, D1, LR-, LG-, GND and +12V to the
TruPortal controller.
•Connect the RS485 Line (A, B) to the converter. Connect
the converter in the PC.
•Fingerprint enrollment is done from the ACL800
BioManager software. Connection between the biometric
readers and the PC must be established.
•The Biometric readers communicate with each other with
a RS485 and with the ACL800 BioManager software through a
converter.
•The RS485 Line should be configured in the form of a
daisy chain, NOT in a form of a star. Keep the stubs from the
RS485 backbone as short as possible (not more than 5
meters)
•Only one converter per installation is needed, not per
reader.
The 120 Ohm end-of-line resistors are necessary and provided
with the products.
RS485 tuning
Figure 4: RS485 tuning
•Terminate both ends of the line with 120 Ohm resistor
•If the communication is not established and stable, use the
external resistors provided in the hardware kit.
Swiping technique
Figure 5: Enrollment
Follow the below instructions for correct finger swiping
Starting from the first finger joint, place the selected finger on
the swipe sensor and move it evenly downwards in one steady
movement.
For a valid swipe: Tricolour Status LED turns green + OK
beep(short + long beep)
For an invalid or misread swipe: Tricolour Status LED turns red
+ error beep ( 3 short beeps)
Configuring the biometric readers in
ACL800 BioManager
ACL800 BioManager is software for fingerprint management of
biometric readers, when used with third party access
controllers.
Main functions:
o Fingerprint Enrollment
It can be done by ANY biometric reader in the network or by
desktop (USB) biometric reader
o Fingerprint Transfer
Finger templates can be sent to any reader in the network.
Different users can be sent to different biometric readers
o Wiegand output Configuration
The Wiegand output of the Biometric reader can be
customized bitwise
Add Portal
•Right-click on “Portals” and select “Add Portal”.
•If the converter used for the biometric readers is RS485 to
TCP/IP, then create a portal by adding the IP Address of the
converter. (Figure 6)
12 VDC
Red
+12 VDC
GND
Black
Ground
A
Pink
A (RS485)
B
Violet
B (RS485)
Tamp
Blue
Tamper
Tamp
Green
Tamper
LG-
Yellow
LED green -
LR-
Orange
LED red -
D1
White
Data 1
D0
Green
Data 0

P/N 1073505A• REV 00.00 • ISS 4JUL18 3 / 7
Figure 6: Add Portal
Note: The portal can be added automatically with the “Search”
function.
Add Reader
•Right-click on the portal connected to the reader and
select “Add Reader”
•Select the type of the reader and fill the reader form. Put
the serial number of the biometric reader. The serial number is
written on the back side of the reader, but also can be
searched from the software
Click on “Save”and the reader icon appears under
the selected portal
Right-click on reader and select “Check version”to
see if the reader is online
If reader is online, new line is added on top of the
event table
If reader is not online, following line is added on top of
the event table
Note: The reader can be added automatically with the
“search” function
Edit reader
Right-click on the reader and select “Properties”
Edit reader properties and click “Save”button.

4 / 7 P/N 1073505A• REV 00.00 • ISS 4JUL18
Check at event table if the configuration was successful.
Delete reader
Right-click on the reader and select “Delete”reader
ADD user
1. Open the Users Window and create a new user.
Click on “New User”, put a name and ID (card number).
2. Select the reader (with left click) from which the enrollment
will be done.
3. Right click on the fingertip and select enroll.
4. In the next 25 sec. swipe the finger on the selected reader
min. 5 times and the fingertip will turn green.
In these 25 sec. the reader will continuously blink.
5. Repeat point 4 & 5 for each finger that should be enrolled.
6. Click on “Save New” and the fingerprint will be sent
automatically to all biometric readers where that user has
access, i.e. to all the readers according to the Access Level
assign to that user.
Example:
If the user has “Unlimited” Access level then the fingerprints
will be sent to all readers, if the user has Access level only for
Reader 1 and Reader 3 then the fingerprints will be sent only
to those two readers.
Note:
To check if all the fingerprints are sent to the reader, right click
on the reader and select “Memory Status”.

P/N 1073505A• REV 00.00 • ISS 4JUL18 5 / 7
In the event window, a line will appear indicating the number of
fingerprints stored in the reader.
Note:
If more fingerprints are added for one user, all fingerprints will
send the same Wiegand code to the controller, the one written
in the field User ID (card Number).
Note:
Users can be imported from Excel file or from TruPortal
Deleting fingerprints
In general, the fingerprints are stored in the biometric reader
and in the software.
Deleting one user from the biometric reader
Select the User
Click on “Delete User”. The user, together with its
fingerprints will be deleted from both the software and
the fingerprint readers
Deleting all users from the biometric reader
Right click on the reader and select “Delete all users
from reader”
Delete one or more fingerprints
Select the User and click “Edit”.
Go to the fingertip that needs to be deleted, right click and
select ”Delete” for one finger or “Delete All” for all fingers of the
User
Click “Save”.
With this procedure, the fingerprints are deleted from the
software and from the reader.

6 / 7 P/N 1073505A• REV 00.00 • ISS 4JUL18
Uploading the fingerprints to the biometric
readers
Right click on the biometric reader
Select “Upload all users to reader”
While receiving the fingerprints, the reader will blink.
Note: Use this feature when you change or add a
reader, if pending tasks are deleted in the software or
if there are doubts that fingerprints in the reader
memory are not synchronized with the software
database.
In normal usage, the fingerprints are sent
automatically and this feature is not used.
Wiegand output selection
Select the Wiegand output format of the reader in
Settings/Wiegand
Select among the predefined Wiegand outputs or create
custom one.
Send the configuration to the biometric reader
Safety precautions
Do not install the device in a place subject to direct sun light
without protective cover.
Do not install the device and cabling close to a source of
strong electro-magnetic fields like radio-transmitting antenna.
Do not place the device near or above heating equipment.
If cleaning, do not spray or splash water or other cleaning
liquids but wipe it out with smooth cloth or towel.
Do not let children touch the device without supervision.
Note that if the sensor is cleaned by detergent, benzene or
thinner, the surface will be damaged and the fingerprint can't
be entered.
In the event window a line will appear indicating the number of
fingerprints stored in the reader.
Note: If more fingerprints are added for one user, all
fingerprints will send the same Wiegand code to the controller,
the one written in the field User ID (Card numbers).

P/N 1073505A• REV 00.00 • ISS 4JUL18 7 / 7
Regulatory information
Trademarks and
patents
The trade names used in this document may be
trademarks or registered trademarks of the
manufacturers or vendors of the respective
products.
Manufacturer
Interlogix.
2955 Red Hill Avenue, Costa Mesa, CA 92626
5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands
Certification
European Union
directives
This product and - if applicable - the supplied
accessories too are marked with "CE" and
comply therefore with the applicable harmonized
European standards listed under the EMC
Directive 2014/30/EU, the RoHS Directive
2011/65/EU.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info.
2013/56/EU & 2006/66/EC (battery directive):
This product contains a battery that cannot be
disposed of as unsorted municipal waste in the
European Union. See the product documentation
for specific battery information. The battery is
marked with this symbol, which may include
lettering to indicate cadmium (Cd), lead (Pb), or
mercury (Hg). For proper recycling, return the
battery to your supplier or to a designated
collection point. For more information see:
www.recyclethis.info.
Product warnings
and disclaimers
THESE PRODUCTS ARE INTENDED FOR
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED
DEALER” OR “AUTHORIZED RESELLER”, IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
www.firesecurityproducts.com/policy/product-
warning/ or scan the following code:
Contact
information and
manuals
For contact information go to: www.interlogix.com
or www.firesecurityproducts.com
To get translations for this and other product
manuals go to: www.firesecurityproducts.com
Table of contents
Other Interlogix IP Access Controllers manuals