ACL875SU-BS is access control fingerprint reader designed
for easy management of the users and configuration. The
scanner is made with advanced capacitive sensing technology
that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users
fingers
- same performance in the different light conditions
- good reading of fingers with stains from daily jobs
Built in strong scanning and matching algorithm provides
excellent tolerance in the way finger is swiped over the sensor
reducing to minimum the need to repeat finger swiping at the
sensor.
The reader can store up to 99 finger templates and 97 PIN
codes. One template is reserved for user manager
(Administrator), one template is reserved for reader
configuration (Installer) and up to 97 templates are for users.
Recommendations
Consult with installer about safety level of the installation.
There are devices with relays compatible with this reader that
can increase the security of the system if needed. One or two
enrolled fingers are enough for one user. Ask the installer
before he leaves the site to enroll your finger as administrator.
Notes
The Reader is using physical roughness of the fingerprint to
scan the finger. Some of the users may have very flat
fingertips, making difficult for the sensor to recognize correctly
the fingerprint. In most cases, these are children and older
persons. To solve this problem, do the following:
1. Try with different user’s fingers to find the “best” finger.
2. Check with the installer other models of the reader with
added card reader or keypad for other type of access.
Maintenance
No special or periodic maintenance is required. If cleaning is
needed, use soft wet cloth and wipe gently to clean off the dirt.
Do not use chemicals and materials that can scratch the
sensor.
Warning!
Do not touch the sensor with other objects than finger. Do not
pour or splash with water or other liquids. When painting or
construction work is ongoing in the area around the reader,
protect the reader sensor area from possible damages and
paint. If reader is to be dismounted or relocated, call authorized
installer for the job. Disposal of this product must be handled
according to all national laws and regulations.
Mounting
Figure 1: Mounting instructions
•Do not install the device and cabling close to a source of
strong electro-magnetic fields like radio-transmitting antenna.
•Do not place the device near or above heating equipment.
•If cleaning, do not spray or splash water or other cleaning
liquids but wipe it out with smooth cloth or towel.
•Do not let children touch the device without supervision.
•Note that if the sensor is cleaned by detergent, benzene or
thinner, the surface will be damaged and the fingerprint can't
be entered.
If the biometric reader is installed and used in outdoor
environments, the reader MUST be fitted with a weather

2 / 7 P/N 1073523A• REV 00.00 • ISS 4JUL18
protection cover in order to protect the sensor from direct
rainfall. The operating temperature of the product is between -
20 to + 50ºC. If the reader is installed in an environment where
the temperature can drop below -10ºC or/and if the sensor
could only be exposed to direct sunlight, it is strongly
recommended to install the reader inside a third party sealed
wall mount box (fitted with additional heater if very low
temperature) to keep a constant sensor level performance. We
cannot guarantee the functionality of the product if the
recommendations and advice are not followed.
Specifications
Fingerprint Capacity:
97 templates
PIN Code Capacity:
97 PIN Codes (1 to 8 digits)
Output:
1 x Relay (2A at 24V AC/DC)
Push Button Input:
Yes
Door Open Time:
Pulse (1 to 30 seconds) or Toggle (ON/OFF)
Entry Mode:
Finger or access code
Programming:
By swiping or by keypad
Master/Admin Fingers:
1 Administrator and 1 Installer finger
Backlight ON/OFF:
Yes
Buzzer ON/OFF:
Yes
Firmware upgrade:
via RS485 converter and windows application
Current Consumption:
150 mA max.
Power Supply:
9 to 14 V DC
Indication:
Tricolor Status LED
IP Factor:
IP65
Storage/Operating
Temperature :
-20 to +50°C
Storage/Operating
Humidity:
5% to 93% noncondensing
Dimensions
100 x 94 x 30 mm
Application diagram
Figure 2: Application diagram
ACL875SU-BS
ACL800FL-RU2 : Optional) 2 Relay Remote Unit
ACL870FL-PB (Optional): 2 Relay Remote Unit and request-to-
exit Button
ACL870SU-PB (Optional) : 1 Relay Remote Unit and request-
to-exit Button
Wiring
Figure 3: Wiring
Figure 4: Wiring ACL870SU-BSMF with magnetic lock
Recommended swiping technique
Figure 5: Swiping technique
Follow the below instructions for correct finger swiping. Starting
from the first finger joint, place the selected finger on the swipe
sensor and move it evenly downwards in one steady
movement.
Result:
For a valid swipe: Tricolour status LED turns green + OK beep
(short + long beep)
Red
Black
Pink
Violet
Blue
Green
Orange
Gray
Yellow
White
12 VDC
Red
+12 VDC
GND
Black
Ground
A
Pink
A (RS485)
B
Violet
B (RS485)
Tamp
Blue
Tamper
Tamp
Green
Tamper
PB
Orange
Push Button
NC
Gray
NC
COM
Yellow
COM
NO
white
NO
Outside
Secured Area
ACL800FL-RU2
ACL870FL-PB
ACL870SU-PB
12 VDC
POWER
SUPPLY

P/N 1073523A• REV 00.00 • ISS 4JUL18 3 / 7
For an invalid or misread swipe: Tricolour status LED turns red
+ error beep ( 3 short beeps)
Indication OK beep - short + long beep
Error beep - 3 short beeps
Swipe finger - 2 short beeps
Tricolor status LED :
Green - Access granted
Red - Access denied
Orange - Idle mode
Adding admin finger
1
Push dip switch no.2 in
position ON
2
Reset the Power of the
device
12/24VAC/DC
3
Wait for One long + multiple
short beeps
4
4.Put the dip switch in
position OFF. (short beeps
will stop)
5
Wait for about 15 seconds for
the LED to blink in Orange
6
Swipe the Master finger
min.6 times. (Until Ok Beep)
X 6
Warning:
This procedure also deletes all the users, the
installer’s finger, installer’s PIN Code and admin’s PIN
Code.
This procedure will unpair the connected relay unit
unit (ACL870SU-PB, ACL870FL-PB or ACL800FL-
RU2)
Pairing - biometric reader and remote relay
unit
If secure installation is needed, the reader can be connected to
remote relay unit at secured area, which also can play the role
of request-to-exit push button. Follow the instructions bellow to
pair (couple) both devices or refer to the Remote Relay’s
Manual.
Pairing ACL875SU-BS with ACL870FL-PB
Figure 6: Wiring
1. Close the jumper. ACL870FL-PB beeps continuously and
the red led blinks.
2. Open the jumper
3. Wait for beep + OK beep (short + short + long beep)
After the OK beep, the coupling is done.
Pairing ACL875SU-BS with ACL870SU-PB
Figure 7: Wiring
1. Put dipswitch No.1 to position ON. ACL870SU-PB beeps
continuously and the red led blinks.
2. Put dipswitch No.1 to position OFF.
3. Wait for beep + OK beep (short + short + long beep)
After the OK beep, the coupling is done.
Pairing ACL875SU-BS with ACL800FL-RU2
Figure 8: Wiring
1. Put the jumper to closed position. ACL800FL-RU2 beeps
continuously and the red led blinks.
2. Put the Jumper to open position.
3. Wait for beep + OK beep (short + short + long beep)
After the OK beep, the coupling is done.
Warning: Changing the ADMIN finger will also unpair the
remote relay unit.
ACL875SU-BS
ACL875SU-BS

4 / 7 P/N 1073523A• REV 00.00 • ISS 4JUL18
Administrator programming
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers. Administrator finger is enrolled at
the end of the system installation. Initial enrollment of the Admin finger is described in installer manual
Figure 9: Finger
ADD Finger Relay 1 (Finger that will activate relay 1)
Action
Finger
Backlight
Buzzer Sound
Swipe Admin Finger 1 time
X 1
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
short beep
Swipe User Finger min. 6 times
(until short + long beep)
X 6
fast
blinking
short + long beep
ADD Finger Relay 2 (Finger that will activate relay 2)
Action
Finger
Backlight
Buzzer Sound
Swipe Admin Finger 2 times
X 2
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
short beep
Swipe User Finger min. 6 times
(until short + long beep)
X 6
fast
blinking
short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays (ACL870FL-PB and ACL800FL-RU2). Consult the
installer if Relay 2 is available in your system.
ADD Finger Relay 1&2 (Finger that will activate relay 1&2)
Action
Finger
Backlight
Buzzer Sound
Swipe Admin Finger 3 times
X 3
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
short beep
Swipe User Finger min. 6 times
(until short + long beep)
X 6
fast
blinking
short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays (ACL870FL-PB and ACL800FL-RU2). Consult the
installer if Relay 2 is available in your system.
DELETE Finger
Action
Finger
Backlight
Buzzer Sound
Swipe Admin Finger 4 times
X 4
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
short beep
Swipe User Finger
X 1
fast
blinking
short + long beep
DELETE ALL Fingers and Cards
Action
Finger
Backlight
Buzzer Sound
Swipe Admin Finger 4 times
X 4
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
slow
blinking
short beep
Swipe Admin Finger 2 times
X 2
fast
blinking
multiple beeps
INSTALLER
RIGHT
ADMIN
LEFT

P/N 1073523A• REV 00.00 • ISS 4JUL18 5 / 7
CHANGE ADMIN Finger
Action
Finger
Backlight
Buzzer Sound
Swipe Admin Finger 5 times
X 5
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
slow
blinking
short beep
Swipe NEW Admin Finger
min.6 times
X 6
fast
blinking
short + long beep
CHANGE INSTALLER Finger
Action
Finger
Backlight
Buzzer Sound
Swipe Admin Finger 6 times
X 6
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
slow
blinking
short + long beep
Swipe NEW Installer Finger
min.6 times
X 6
fast
blinking
3 short beeps
Administrator Programming block diagram
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu
Installer programming by finger
Set Relay 1 Time
Action
Finger
Backlight
Buzzer Sound
Swipe Installer Finger 1 time
X 1
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
short beep
Swipe the INSTALLER Finger
and start counting seconds
X 1
fast
blinking
beeps on 1 second
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
X 1
fast
blinking
short + long beep
Set Relay 2 Time
Action
Finger
Backlight
Buzzer Sound
Swipe Installer Finger 2 times
X 2
slow
blinking
short beep
Only in combination with
ACL870FL-PB andACL800FL-RU2

6 / 7 P/N 1073523A• REV 00.00 • ISS 4JUL18
Wait 5 seconds (until fast blinking)
short beep
Swipe the INSTALLER Finger
and start counting seconds
X 1
fast
blinking
beeps on 1 second
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
X 1
fast
blinking
short + long beep
Relay 2 is available if the reader is used with remote relay unit with 2 relays (ACL870FL-PB and ACL800FL-RU2). Consult the installer if Relay 2 is
available in your system.
BUZZER ON/OFF
Action
Finger
Backlight
Buzzer Sound
Swipe Installer Finger 3 times
X 3
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
short beep
Swipe Installer Finger
X 1
fast
blinking
short + long beep
BACKLIGHT ON/OFF
Action
Finger
Backlight
Buzzer Sound
Swipe Installer Finger 4 times
X 4
slow
blinking
short beep
Wait 5 seconds (until fast blinking)
short beep
Swipe Installer Finger
X 1
fast
blinking
short + long beep
Installer Programming block diagram
Swipe the Installer Finger 1 to 4 times depending of the desired menu
Only in combination with
ACL870FL-PB andACL800FL-RU2

P/N 1073523A• REV 00.00 • ISS 4JUL18 7 / 7
Regulatory information
Trademarks and
patents
The trade names used in this document may be
trademarks or registered trademarks of the
manufacturers or vendors of the respective
products.
Manufacturer
Interlogix.
2955 Red Hill Avenue, Costa Mesa, CA 92626
5923, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands
Certification
European Union
directives
This product and - if applicable - the supplied
accessories too are marked with "CE" and
comply therefore with the applicable harmonized
European standards listed under the EMC
Directive 2014/30/EU, the RoHS Directive
2011/65/EU.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.recyclethis.info.
2013/56/EU & 2006/66/EC (battery directive):
This product contains a battery that cannot be
disposed of as unsorted municipal waste in the
European Union. See the product documentation
for specific battery information. The battery is
marked with this symbol, which may include
lettering to indicate cadmium (Cd), lead (Pb), or
mercury (Hg). For proper recycling, return the
battery to your supplier or to a designated
collection point. For more information see:
www.recyclethis.info.
Product warnings
and disclaimers
THESE PRODUCTS ARE INTENDED FOR
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED
DEALER” OR “AUTHORIZED RESELLER”, IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
www.firesecurityproducts.com/policy/product-
warning/ or scan the following code:
Contact
information and
manuals
For contact information go to: www.interlogix.com
or www.firesecurityproducts.com
To get translations for this and other product
manuals go to: www.firesecurityproducts.com
This manual suits for next models
1
Table of contents
Other Interlogix IP Access Controllers manuals