CDVI micro IEVO-M User manual

EN IEVO-M
micro™ Fingerprint Reader
ievo® micro™ Fingerprint Reader
Installation Manual
IEVO-M
EN

2 3
EN EN
IEVO-M
micro™ Fingerprint Reader
1] CONTENTS
TITLE PAGE
2] Package Contents 3
3] Technical Features 3
4] Introduction 4
Standards 4
Help & Support 4
5] Installation Guidance 5
Power 5
Reader Head Cabling 6
Wiegand Cabling 6
Network 6
6] Control Board Connections 7
7] Door Wiring Example 8
8] Surface Mount Installation 9
9] Flush Mount Installation 10
Installation Complete 11
10] Product Disposal 12

2 3
EN EN IEVO-M
micro™ Fingerprint Reader
2] PACKAGE CONTENTS
Phoenix
Connector
(CTF-03008)
Back plate
5m CAT6
cable
Reader
Head
11111111
Description Data
CPU ARM
Connection Shielded (S-FTP) Cat5e/6 cable
Voltage 12V
Current Draw 400mA
Communication RS-422 (1Mbit/s)
Controller ievo Control Board
Operating Temperature 0~60ºC
Power Indicator LED
IP Rating IP65
Dimensions Surface Mount: 155mm (H) x 55mm (W) x
70mm (D)
Flush Mount: 230mm (H) x 80mm (W) x 33mm
(D)
3] TECHNICAL FEATURES

4 5
EN EN
IEVO-M
micro™ Fingerprint Reader
4] INTRODUCTION
Symbol Description
Open Book
Please refer to the user manual once installation is complete
Caution
For the safety of yourself and others please refer to the user manu-
al for specic instructions on using this product.
Anti-Static Discharge
Please follow ESD safety procedures.
Ground yourself to avoid any damage to the electrical components.
Damage caused ESD is not covered under warranty.
Restriction of Hazardous Substances
The restriction of the use of certain hazardous substance in electri-
cal and electronic equipment.
Waste Electrical and Electronic Equipment
When discarding of this product, please send to separate collection
facilities for recovery and recycling. Separating from other house-
hold type waste.
European Conformity
Conforms with the essential requirements of the applicable European
Conformity directives.
Federal Communications Commission
Government agency established by the Communications Act of 1934
which regulates all interstate communications.
This manual will guide you through the installation of an ievo micro™ reader.
Please ensure you read and understand all the information in this manual before
commencing with installation.
STANDARDS
HELP & SUPPORT
If at any point during installation you need help, please contact the Technical
Support Team:
Telephone (UK): +44 (0) 1628 531300
Email: [email protected]
Website: www.ievoreader.com/Support

4 5
EN EN IEVO-M
micro™ Fingerprint Reader
5] INSTALLATION GUIDANCE
The micro™ reader is suitable for internal use only.
The micro reader can be either ush or surface mounted. Ensure you use the
correct xings and plugs for the type of wall for which you are xing the reader.
Incorrect usage can result in the Micro reader being unsecure.
The micro reader should only be mounted vertically. It is not recommended to
mount any ievo reader horizontally as this can affect performance and usability.
We recommend that you install the Micro reader following DDA Guidelines,
installing the reader at a height of between 1m and 1.2m. This is the optimum
height for nger placement.
The ievo Control Board must be installed on the protected side of the door or
turnstile. The control board is not IP rated, but can be installed inside most IP
rated enclosures.
POWER
A single ievo control board with two micro readers connected will pull 1.6Amps
when operating at full capacity. We recommend that you use a Surge Protected,
12 – 24V, AC (Alternating Current) or DC (Direct Current), 2Amp power supply
unit (PSU) to power each ievo Control Board. We also recommend tting a backup
battery.
It’s important you correctly calculate the amperage rating if using a shared PSU.
If using separate PSU’s for separate equipment, ensure they share a common
ground connection.
ievo equipment must be used with an EN 60950-1 or an equivalent IEC standard
complaint PSU. This is to establish adequate safety testing of the PSU to ensure
that there is enough isolation provided from the mains supply.
Please ensure that the cable used between the Power Input on the ievo Control
Board and your chosen Power Supply Unit is adequate for the current, amperage
and environment.
If you are using an ievo Control Board with a Power Over Ethernet (PoE) module,
you will require a POE+ (802.3at) rated injector or switch to supply power and
network connectivity.
Please follow ESD Safety Procedures to prevent any damage to electronic components.

6 7
EN EN
IEVO-M
micro™ Fingerprint Reader
READER HEAD CABLING
Each micro reader uses a bespoke PoE (Power over Ethernet) connection to
the ievo Control Board, carrying both power and data. Therefore, you must
use a high-quality shielded Ethernet cable to prevent power and data loss.
Each reader comes provided with a 5m CAT6 SFTP (braid-shielded cable,
foil-shielded pairs) Ethernet cable. If you need to place the reader further
than 5m away from the control board, please use a cable with the following
specication:
• Up to 50m – Cat5e/Cat6a SFTP Stranded-conductor, 26 AWG, with
shielded RJ45 connectors
• Up to 90m – Cat5e/Cat6a SFTP Solid-conductor, 24 AWG with shielded
RJ45 connectors
Note: Cat7 specication cable is too thick to use for connection to the head.
WIEGAND CABLING
We recommend that you use Belden 9534 (4 Core shielded) cable for the
Wiegand connection between the ievo Control Board and Access Control Unit.
We recommend twisting 2 pairs for Clock and Data and using the shielding
for Ground. The distance between the ievo Control Board and Access Control
Unit must not exceed 25m.
NETWORK
Each ievo control Board requires an Ethernet cable connected back to the
local network.
We recommend using CAT5e shielded cable and the distance must not exceed
90m.
If you are using the ievo Control Board with a Power Over Ethernet (PoE)
module, then the cable between the PoE switch or injector and ievo Control
Board must meet the below specication:
• Up to 50m – Cat5e/Cat6a SFTP Stranded-conductor, 26 AWG, with
shielded RJ45 connectors
• Up to 90m – Cat5e/Cat6a SFTP Solid-conductor, 24 AWG with shielded
RJ45 connectors

6 7
EN EN IEVO-M
micro™ Fingerprint Reader
6] CONTROL BOARD CONNECTIONS
Wiegand Output A
Wiegand Output B
Network OUT
Provides a network
bridge to a single ACU
Network IN
Provides Network
connection to PC or local
Network
Power input
PoE/Network IN input
when using POE module

8 9
EN EN
IEVO-M
micro™ Fingerprint Reader
7] DOOR WIRING EXAMPLE
ACU Power
Supply Unit
Access
Control Unit
Network
Switch
Lock
Power
Ethernet
Reader Cable
Wiegand Cable
Ground Connection

8 9
EN EN IEVO-M
micro™ Fingerprint Reader
8] SURFACE MOUNT INSTALLATION
STEP 1:
Use the wall plate to mark out the size of the hole required for the Micro reader
cable. Alternatively, you can push out the plastic notch at the top of the wall
plate and feed the ethernet cable through the hole so that it can be hidden within
conduit above the reader.
STEP 2:
Attach the wall plate to the wall using
6 screws.
STEP 3:
Connect the Ethernet cable into the
back of the Micro reader.

10 11
EN EN
IEVO-M
micro™ Fingerprint Reader
STEP 4:
Tilt the micro reader head back and clip
the top security clip onto the backplate,
once attached, push the rest of reader
onto the back plate.
STEP 5:
Push the Micro reader rmly until the
security clips click into place.
9] FLUSH MOUNT INSTALLATION
STEP 1:
Connect the Ethernet cable into the
back of the micro reader.
STEP 2:
Clip the micro reader into the ush
plate.

10 11
EN EN IEVO-M
micro™ Fingerprint Reader
STEP 3:
Mount the micro reader and ush kit
into the wall, place the facia over the
top and screw into place using the 2
screws provided.
STEP 4:
Cover the 2 screws with the screw caps
provided.
Wall
Please move onto the applicable software manual for your system. You
can download all our manuals and installation guides from:
www.cdvi.co.uk/cat/ievo-biometric-solutions
!
INSTALLATION COMPLETE

12 13
EN EN
IEVO-M
micro™ Fingerprint Reader
10] PRODUCT DISPOSAL
When the product reaches the end of its useful life, it
must not be disposed of in normal waste. The product
must be disposed of at an authorised recycling plant.
The ievo Control Board contains a Lithium metal
primary coin cell battery (location highlighted below)
and should be removed by a competent engineer prior
to disposal.
The ievo equipment and the removed battery must be disposed of separately at
an authorised recycling point. Your local authority will have a centre which accepts
such waste for recycling.
WARNING: Batteries and products containing batteries must never be disposed
of in res.

12 13
EN EN IEVO-M
micro™ Fingerprint Reader
Notes
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
..............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................
...............................................................................................................................

www.cdvigroup.com
CDVI Group
FRANCE (Headquarters)
Phone: +33 (0) 1 48 91 01 02
Extranet : CDVI_IEVO-M_IM_01_EN_A5_C
CDVI FRANCE + EXPORT
+33 (0) 1 48 91 01 02
www.cdvi.com
CDVI AMERICAS [CANADA - USA]
+1 (450) 682 7945
www.cdvi.ca
CDVI BENELUX [BELGIUM - NETHERLANDS - LUXEMBOURG]
+32 (0) 56 73 93 00
www.cdvibenelux.com
CDVI GERMANY
+49 (0) 175 2932 901
www.cdvi.de
CDVI TAIWAN
+886 (0) 42471 2188
www.cdvichina.cn
CDVI SUISSE
+41 (0) 21 882 18 41
www.cdvi.ch
CDVI CHINA
+86 (0) 10 84606132/82
www.cdvichina.cn
CDVI IBÉRICA [SPAIN - PORTUGAL]
+34 (0) 935 390 966
www.cdviberica.com
CDVI ITALIA
+39 (0) 321 90 573 - www.cdvi.it
CDVI MAROC
+212 (0) 5 22 48 09 40
www.cdvi.ma
CDVI NORDICS
[SWEDEN - DENMARK - NORWAY - FINLAND]
+46 (0) 31 760 19 30
www.cdvi.se
CDVI UK [UNITED KINGDOM - IRELAND]
+44 (0) 1628 531300
www.cdvi.co.uk
CDVI POLSKA
+48 (0) 12 659 23 44
www.cdvi.com.pl
All the information contained within this document (pictures, drawings, features, specications and dimensions)
could be perceptibly different and can be changed without prior notice.
Table of contents
Other CDVI IP Access Controllers manuals

CDVI
CDVI DGLIWLC User manual

CDVI
CDVI KCPROXWLC User manual

CDVI
CDVI NANOPW User manual

CDVI
CDVI TERENA User manual

CDVI
CDVI Digicode Mifare PCV123D User manual

CDVI
CDVI Ievo User manual

CDVI
CDVI KCPROXWLC User manual

CDVI
CDVI SOLARPB Instruction Manual

CDVI
CDVI SOLARPW User manual

CDVI
CDVI DGLIWLC User manual

CDVI
CDVI Digicode Mifare PCV123D User manual

CDVI
CDVI KCPROXWLC User manual

CDVI
CDVI MOONARW User manual

CDVI
CDVI PASS KCPASS User manual

CDVI
CDVI STAR1M User manual

CDVI
CDVI BIOSYS 1 User manual

CDVI
CDVI GALEOR User manual

CDVI
CDVI SOLARPW User manual

CDVI
CDVI DGLIEWLC User manual

CDVI
CDVI PROMI500 User manual