inveo IND-U1 User manual

User manual
RFID IND-U1 Reader
INVEO s.c.
ul. Rzemieślnicza 21
43-340 Kozy
tel: +48 785552252
www.inveo.com.pl
in o@inveo.com.pl

Dear Customer!
Thank you very much or choosing our product. Be ore its use, please read these
instructions care ully. There are given here the most appropriate ways o dealing with
this device, the basic principles o sa ety and maintenance. Please also keep the user
manual so that you can read it during later use.
Remember!
The manufacturer s not l able for any damage caused by mproper use of
the dev ce for ts ntended purpose or mproper handl ng, as well as fault dr ver
result ng from mproper use.
03/16/2018 User manual RFID-IND-U1 Page 2 z 16

Table of contents
1 PRELIMINARY INFORMATIONS..................................................................................................................4
2 PURPOSE OF THE DEVICE.............................................................................................................................5
3 WARRANTY AND LIABILITY OF THE MANUFACTURER......................................................................5
4 SAFETY GUIDELINES......................................................................................................................................6
4.1 POWER SUPPLY....................................................................................................................................................6
4.2 STORAGE, WORK CONDITIONS.................................................................................................................................6
4.3 INSTALLATION AND USE OF THE MODULE...................................................................................................................6
4.4 UTILISATION OF THE MODULE.................................................................................................................................6
5 CONSTRUCTION OF THE MODULE............................................................................................................7
5.1 GENERAL FEATURES..............................................................................................................................................7
6 DEVICE CONFIGURATION.............................................................................................................................8
6.1 OUTPUTS – OUTPUTS OPERATING MODE................................................................................................................
...............................................................................................................................................................................
6.2 INPUTS – STATUS OF INPUTS............................................................................................................................10
6.3 BUZZER & LEDS – LEDS AND SOUND SIGNALING CONTROL...............................................................................10
6.4 RS485 - CONFIGURATION RS485......................................................................................................................10
6.5 CARD SERIAL NUMBER - READ CARD NUMBER...........................................................................................10
7 MODBUS SUPPORT.........................................................................................................................................11
7.1 MODBUS ADDRESSES......................................................................................................................................11
8 DESCRIPTION OF TERMINALS...................................................................................................................14
DISTANCE FIXING HOLES...........................................................................................................................15
NOTES.................................................................................................................................................................16
Before start ng work w th the dev ce, read The User manual and follow the
nstruct ons conta ned there n!
03/16/2018 User manual RFID-IND-U1 Page 3 z 16

1 Prel m nary nformat ons
Before start ng work w th the dev ce, read The User manual and follow the
nstruct ons conta ned there n!
Description o visual symbols used in this user manual:
This symbol is responsible or reviewing the appropriate place in the
user instructions, warnings and important in ormation. Failure to
ollow warnings could cause injury or damage to the module
Important in ormation and guidelines
Following this guidelines makes the use o the module easier.
Attention: The appearance o the screen shots shown in this manual may di er slightly
rom the actual work with the module. The di erences may relate to the size and ont
type and size o symbols. There are no di erences in the content o the in ormation.
03/16/2018 User manual RFID-IND-U1 Page 4 z 16

2 Purpose of the dev ce
RFID-IND-U1 reader is used to read the UNIQUE transponders code. The transponder
code is available using the MODBUS RTU protocol.
3 Warranty and l ab l ty of the manufacturer
The manu acturer provides a 2-year warranty on the module. The manu acturer also
provides post-warranty service or 10 years rom the date o the introducing the module
on the market. The warranty covers all de ects in material and workmanship
The manufacturer undertakes to comply with the contract of guarantee, if the following
conditions are met::
all repairs, alterations, extensions and device calibrations are performed by the
manufacturer or authorized service,
supply network installation meets applicable standards in this regard,
the device is operated in accordance with the recommendations outlined in this
manual
the device is used as intended..
The manu acturer assumes no responsibility or consequences resulting rom improper
installation, improper use o the module, not ollowing this manual and the repairs o the
module by individuals without permission.
Th s dev ce doesn’t conta n serv ceable parts.
03/16/2018 User manual RFID-IND-U1 Page 5 z 16

4 Safety gu del nes
The module has been constructed using modern electronic components, according to the
latest trends in the global electronics. In particular, much emphasis was placed on
ensuring optimum sa ety and reliability o control. The device has a IP65 hermetic
housing with a high-quality plastic.
4.1 Power supply
The module is suitable or power supply 10-24VDC.
4.2 Storage, work conditions.
The reader is equipped with a sealed IP65 enclosure which means:
•total resistance to oreign objects
•resistance to water jet directed directly to the device
•storage and operation at temperatures rom -25 ° C to + 60 ° C,
4.3 Installation and use of the module
The module should be used follow ng the gu del nes shown n next part of the
user manual.
4.4 Utilisation of the module
When it becomes necessary to liquidate the device (e.g., a ter the time o use), please
contact the manu acturer or its representative, who are obliged to respond appropriately,
i.e., collecting the module rom the user. You can also ask the companies involved in
utilization and / or liquidation o electrical or computer equipment. Under no
circumstances should you place the device along with other garbage
03/16/2018 User manual RFID-IND-U1 Page 6 z 16

5 Construct on of the module
.1 General features
The reader is equipped with an RS485 port supporting MODBUS RTU protocol and
a USB port used or con iguration and testing o the module.
The device has two relay outputs and two inputs.
Techn cal data:
Supply voltage:12-24VDC
Power supply: 15mA (12V)
Transponders:
Supported transponder standard: UNIQUE
Carrier requency: 125kHz
Reading distance to 10cm (depending on the type o transponder used)
Communication:
1 RS485 port -modbus RTU
1 USB port to con iguration
Inputs/Outputs
2 relay outputs
2 inputs
Dimensions:
(width) 100 mm x (height) 100 mm x (depth) 55.6 mm
03/16/2018 User manual RFID-IND-U1 Page 7 z 16

6 Dev ce conf gurat on
A ter installing the RFID U1 Con ig program and starting it, connect the USB cable
to the computer and the module (in this case, the external power supply o the module is
not required - the device is plugged into the USB port).
The irst line o the program window displays in ormation about the version o the
con iguration program - PC vers on, reader so tware version - RFID Software and
reader version - RFID Hardware. We also have in ormation on whether the
con iguration program was connected to a reader - Connected - Not connected
F gure 1. Program w ndow v ew
03/16/2018 User manual RFID-IND-U1 Page 8 z 16

6.1 OUTPUTS – Outputs operating mode
Mode – Sets the output mode. The output can work in the ollowing modes:
DISABLE
BISTABLE
ASTABLE
TIME – the output will trip to the T me ON then the output will turn o (eg the
control o the electromagnet)
The work charts are shown in the igure below.
Power ON – the state o the output a ter turn on the power
•Act ve
•Inact ve
T me ON – the time or which the channel is switched on (Astable and Time mode)
T me OFF – the time interval between activations o the channel (Astable mode)
State – visualization o the output, i a rectangle is yellow it means that the output
current is turned on.
Buttons Out 1 and Out 2 outputs can be activate or deactivate.
03/16/2018 User manual RFID-IND-U1 Page 9 z 16
t
on
t
off
t
on
t
off
t
on
t
off
t
on
t
on
BISTABLE
ASTABLE
TIME

6.2 INPUTS – Status of inputs
Fields STATE INPUT 1 and STATE INPUT 2 dislays the actual state o inputs. Square
ield in black - input inactive, ield in yellow - active input.
6.3 BUZZER & LEDS – Leds and sound signaling control
In the BUZZER & LEDS settings we can indicate how the leds and the buzzer react when
the card is inserted into the reader.
•OFF - no reaction a ter card application
•ON READ -activation a ter card application
For example, select the option:
When the card is applied to the reader, the LED 1 will light up and the buzzer will sound,
LED 2 will be o .
These options help in interacting with the operator (the person applying the card knows
the reader correctly reads it).
Regardless of the selected sett ng, t s always poss ble to control the s gnal ng
v a the MODBUS RTU protocol.
6.4 RS48 - Configuration RS48
This ield is used to con igure the communication o the reader with the MASTER device.
MODE(setting o 9th bit o transmission):
None
Even – parity bit
Odd – odd bit
BaudRate – speed transmission boxi (1200, 2400, 4800, 9600, 19200, 38400,
57600, 115200)
Dev ce Address – device address or MODBUS protocol
6. CARD SERIAL NUMBER - Read card number
The ield displays the last RFID transponder code read and the type o card.
03/16/2018 User manual RFID-IND-U1 Page 10 z 16

7 Modbus support
The ollowing MODBUS RTU unctions are supported:
- 0x01 Read Coils
- 0x03 Read Holding Register
- 0x05 Write Single Coil
- 0x06 Write Single Register
- 0x0F Write Multiple Coils
- 0x10 Write Multiple Registers
7.1 MODBUS addresses
O.n. Address Type R/W Descr pt on
1 1000 Holding Reg R/W IsNewId
Read: 1 - the correct reading o the RFID tag
Record: 0 -clear the read lag (possible reading o
the next RFID tag)
2 1001 Holding Reg R UID Length -the length o the code o RFID tag
read, or Unique cards: 5
3 1002
-1011
Holding Reg R UID
4 1012 Holding Reg R Card Type: Type o RFID tag read UNIQUE
5 1017 Holding Reg R MODEL ID (0x2401 - U1-unique)
6 1018 Holding Reg R Software Vers on
7 1019 Holding Reg R Hardware Vers on
8 1020 Holding Reg R/W Mode OUT1:
1 - BISTABILE mode
2 - ASTABILE mode
3 -TIME mode
9 1021 Holding Reg R/W T me On OUT1 (1-65535) (*0,1 second)
ex. 120 - 12 seconds
10 1022 Holding Reg R/W T me Off OUT1 (1-65535) (*0,1 second)
ex. 120 - 12 seconds
11 1023 Holding Reg R/W Mode OUT2
1 - BISTABILE mode
2 - ASTABILE mode
3 - TIME mode
12 1024 Holding Reg R/W T me On OUT2 (1-65535) (*0,1 second)
ex. 120 - 12 seconds
13 1025 Holding Reg R/W T me Off OUT2 (1-65535) (*0,1 second)
ex. 120 - 12 seconds
14 1000 Single Coil R/W ON 1 - switching on / o output 1
Read: 1 - output switched on
0 - output switched o
Record: 1 - switching on the output
0 - switching o the output
15 1001 Single Coil R/W ON 2 - switching on / o output 2
16 1002 Single Coil R COIL STATE 1 - state o relay coil no. 1
17 1003 Single Coil R COIL STATE 2 - state o relay coil no. 2
18 1010 Single Coil R INPUT 1 – state o input no. 1
03/16/2018 User manual RFID-IND-U1 Page 11 z 16

19 1011 Single Coil R INPUT 2 – state o input no. 2
20 1012 Single Coil R/W LED1 - switching on / o LED 1
21 1013 Single Coil R/W LED2 - switching on / o LED 2
22 1014 Single Coil W BUZZ ACCEPT – 1 - switching on the sound o
acceptance
23 1015 Single Coil W BUZZ REJECT – 1 - switching on the reject sound
24 1016 Single Coil R/W IsNewId:
Read: 1 - the correct reading o the RFID tag
Record: 0 - clear the read lag (possible reading o
the next RFID tag)
Equivalent to Holding Reg. 1000.
25 1017 Single Coil R/W ResetFlag:
Read: 1- the device has been reset
Record: 0 -reset lag ResetFlag
In general use, you have to polling Coil 1000.
When it change to 1 it is mean that the RFID device read new tag.
Holding registers 1002-1011 contains tag ID.
When you read ID number you should release Coil 1016 (or Holding Reg 1000) lag (clear
to 0). Only a ter that the reader is able to read next ID tag.
Modi ication o the output parameters can be done by the MODBUS protocol. It is not
stored in the module's permanent memory. That means a ter reboot, the output
parameters previously saved to the EEPROM by the con iguration program will be
restored.
Examples o communication:
Quest on: f the card was appl ed:
PDU Address Function Address Number o registers CRC
MASTER SLAVE →01 03 03 E7 00 01 34 79
Answer: Appl ed card:
PDU Address Function How many bytes DATA CRC
SLAVE MASTER→01 03 02 00 01 79 84
Answer: The card has not been appl ed:
PDU Address Function How many bytes DATA CRC
SLAVE MASTER→01 03 02 00 00 B8 44
Read ng the card number n the UNIQUE format:
DIRECTION PDU Address Function Address Number o registers CRC
MASTER SLAVE→01 03 03 E9 00 05 54 79
03/16/2018 User manual RFID-IND-U1 Page 12 z 16

Address Function How
many
bytes
DATA CRC
SLAVE →
MASTER :
01 03 0A 00 54 00 00 00 E5 00 28 00 61 E6 43
Turn ng on the acceptance tone:
PDU Address Function Address DATA CRC
MASTER SLAVE →01 05 03 F5 FF 00 9C 4C
PDU Address Function Address DATA CRC
SLAVE MASTER →01 05 03 F5 FF 00 9C 4C
Sw tch ng relay 1 on:
PDU Address Function Address DATA CRC
MASTER SLAVE →01 05 03 E7 FF 00 3C 49
PDU Address Function Address DATA CRC
SLAVE MASTER →01 05 03 F5 FF 00 3C 49
03/16/2018 User manual RFID-IND-U1 Page 13 z 16

8 Descr pt on of term nals
The view o the PCB is shown in the igure below.
F gure 1. Descr pt on of p ns.
Name Descr pt on
Power Power connector 12-24VDC
OUT 1 Relay output 1
max 1 A i 30 VDC
max 0.5 A i 125 VAC
OUT 2 Relay output 2
max 1 A i 30 VDC
max 0.5 A i 125 VAC
IN 1 Input 1
IN 2 Input 2
USB USB port - module con iguration
RS485 Connector RS485 MODBUS
Boot Shortening the BOOT pins when power is applied causes the module
to enter the bootloader mode
03/16/2018 User manual RFID-IND-U1 Page 14 z 16

9 D stance f x ng holes
03/16/2018 User manual RFID-IND-U1 Page 15 z 16

Notes
…………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………………..
…………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………………..
…………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………………..
…………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………………..
…………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………………..
………………………………………………………………………………………………………………………………………………..
…………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………………..
…………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………………..
…………………………………………………………………………………………………………………………………………………
…………………………………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………………………………..
03/16/2018 User manual RFID-IND-U1 Page 16 z 16
Other manuals for IND-U1
1
Table of contents
Other inveo Other manuals
Popular Other manuals by other brands

Lakes
Lakes QUADRANT Installation & maintenance instructions

Curt Manufacturing
Curt Manufacturing 11431 Installation instructions manual

Dometic
Dometic CT 4050 operating manual

HoMedics
HoMedics mySpa instruction manual

LAMBORGHINI
LAMBORGHINI PAC 120 - SCHEMA manual

ENA
ENA Polycom 450 Quick reference guide