IR-Tec HomeKeeper User manual

T
M
Security & Automation Management System
INSTALLATION&OPERATIONMANUAL
To provide optimal performance of this security system, please read all
contents of this manual carefully before installing and operating. Improper
operation or system setting may result in inferior performance of the system.
V 1.4

TM
2
CONTENTS
1. INTRODUCTIONS.........................................................................................3
2. FEATURES....................................................................................................3
3. SYSTEM DESCRIPTION...............................................................................4
3.1 System devices.................................................................................................... 4
3.2 Main controller ..................................................................................................... 6
3.3 Status indications ................................................................................................ 7
3.4 Detectors/zones categories................................................................................. 7
4. INSTALLATION.............................................................................................8
4.1 Mechanical installation ........................................................................................ 8
4.2 Electrical installation ............................................................................................ 8
5. USER OPERATION.......................................................................................9
5.1 Operation interface .............................................................................................. 9
5.2 Operation code (password) ................................................................................ 10
5.3 Initial state ............................................................................................................ 11
5.4 System check ...................................................................................................... 12
5.5 Master mode........................................................................................................ 15
5.6 Operation modes................................................................................................. 17
5.6.1 AWAY mode ................................................................................................. 17
5.6.2 HOME mode................................................................................................. 17
5.6.3 DISARM mode .............................................................................................. 18
5.7 Alarm reactions.................................................................................................... 18
5.8 Answering phone call .......................................................................................... 19
5.9 Dial-in control....................................................................................................... 20
6. INSTALLER SETTINGS ................................................................................22
6.1 Timer settings ...................................................................................................... 22
6.2 Telephone settings .............................................................................................. 24
6.3 Sound settings..................................................................................................... 28
6.4 System device settings........................................................................................ 29
6.5 Siren settings ....................................................................................................... 33
6.6 Miscellaneous settings ........................................................................................ 34
6.7 GSM settings ....................................................................................................... 35
7. CMS SETTINGS............................................................................................36
8. EXTERNAL CONNECTIONS.........................................................................37
8.1 Remote Message Display.................................................................................... 37
8.2 RS-232 Computer Interface Connection ............................................................. 37
8.3 Ethernet Adaptor and Internet Remote Access Connection............................... 38
8.4 X-10 Power Line Interface Connection................................................................ 38
8.5 Terminal Block Connection ................................................................................. 38
8.6 GSM Module Connection .................................................................................... 39
8.7 Connecting HomeKeeper with Phone/FAX/Answering Machine........................ 39
8.8 Partial Arm for Group 91 to 99............................................................................. 40
9. SPECIFICATIONS.........................................................................................41
10. HK-RC868 Remote Control Keyfob ..............................................................42
11. HK-IR868 HomeKeeper PIR Motion Detector...............................................43
12. HK-IR868P HomeKeeper PIR Motion Detector.............................................47
13. HK-DS868 HomeKeeper Door/Window Sensor............................................51
14. HK-ES868 HomeKeeper Wireless External Siren .........................................53

TM
3
1. INTRODUCTION
Thank you for choosing IR-TEC HomeKeeper IP-based wireless security & automation
management system. This system redefines the standards for convenience and peace of
mind by utilizing the latest microprocessor control and RF telecommunication technologies
to deliver many powerful features and functions to protect your valuable properties.
HomeKeeper provides not only advanced security protection, but also state-of-the-art home
automation that enable property owners to remotely verify the status of lighting devices or
even control the appliance and lighting at anyplace, anytime. In addition, the HomeKeeper
can also operate as an elderly care system and environmental safety monitoring center by
linking with optional medical help button and temperature, humidity or flood sensors.
The interactive programming technology provides ease of installation and system operation
setup for installer and experienced user. Unique HyperSecureLink software allows installer
to check the system status without visiting the site. System owner/user can also access into
the system to re-program the functions or check system status via GSM, Internet or regular
telephone network from work or vacation.
Please keep this manual at handy place for future reference.
2. FEATURES
Supervised RF radio link between system devices and Main Controller.
Responds to burglary, fire, panic, emergency, medical and environmental hazards
Off-site control operation via Internet, PSTN or GSM network.
RS-232 interface PC uploading & downloading.
Maximum 288 wireless sensors/zones plus 3 hardwire zones.
RF signal receiving level indication ensures optimum radio connection.
Advanced RF jamming detection in compliance with highest industry standard.
Hopping-code remote control key fob prevents unauthorized duplication.
Blue-LED backlit 16 x 2 characters user-friendly interactive LCD display.
Delay, Instant, Bypass, Fire, Switch control…etc. fully programmable zone
Detailed 512 alarm event log with date and time stamp.
Latchkey code informs parents when kids leave or return home.
Instant event reporting to telephone, pager CMS, GSM, SMS.
Built-in voice dialer to 10-phone, 1-pager and 2-CMS data link numbers.
Multi-million RF encryption coding and unique time frame transmissions.
Hands-free speakerphone, two-way emergency voice communication.
Dial-in control for listen-in, arm, disarm, event report and automatic switching control.
Controls up to 16 electrical devices via X-10 home automation power control module.
1-master, 7-user, 2-latchkey and 1-duress codes for various user operations.
Temperature, humidity and other sensor connections for environment safety monitoring.
Optional GSM communication module provides second-to-none security protection.

TM
4
3. SYSTEM DESCRIPTION
HK-MC868 Main Controller and many system devices, including various types of detectors
and accessories, form the HomeKeeper Security & Automation Management System. All
radio transmitters used in the HomeKeeper system devices, except the Remote Control
Keyfob, feature with a unique code preset by the factory from total 16,777,216 combinations.
A special transmission timing control technology ensures that all system devices can
communicate with the Main Controller without interfering each other.
Note: In order to comply with the radio communication regulation in most countries, the radio
output power of each system device has been limited to maximum 10 mW. This output
level gives effective communication range up to 200 feet at open field. The
communication range may be reduced within the building, depending on the building
material, furniture and construction.
Functions of Main Controller and other system devices are described as below;
3.1 SYSTEM DEVICES
HK-MC868 HomeKeeper Main Controller
HK-MC868 is the most important command center of the
HomeKeeper system. It not only links with all system
devices by radio signal or wire, but also monitors the status
of all other devices and generates proper alarm condition
whenever necessary. Most contents of this manual are
written for the operation of this system command center.
HK-IR868 Passive Infrared Detector
HK-IR868 is a battery operated passive infrared detector
designed to detect the intruder while system is armed. It
can detect the motion of human body and report to the
Main Controller via built-in radio transmitter. The HK-IR868P
features advanced pet immune technology that is able to
immune floor movements of pets up to 18 Kg.
To correctly install the PIR detector, please refer to the
installation instruction supplied with the unit.
HK-DS868 Door/window sensor
HK-DS868 is a battery operated magnetic sensor designed
to detect the open/close status of the door/window of the
property and report to the Main Controller via its built-in
radio transmitter. To install this device, please refer to the
installation instruction of the unit.

TM
5
HK-RC868 Remote Control Keyfob
HK-RC868 is a remote control keyfob to arm and disarm
the system via radio frequency. It utilizes advanced
hopping code technology to provide up to 7.3 x 1019
combinations whose radio code will change every time
when button is pressed. This advanced technology can
effectively prevents unauthorized keyfob duplicating.
Please refer to page 42 for more about using this device.
HK-ES868 Wireless External Siren
HK-ES868 is an external siren with built-in receiver, which
can be activated by radio signal. To install this device,
please refer to the installation instruction with the unit.
HK-SD868 Wireless Smoke Detector
HK-SD868 is a battery operated smoke detector with built-
in RF transmitter. It will transmit the radio signal to the Main
Controller when it detects smoke in its range.
HK-MH868 Medical Help Activator
HK-MH868 is a wristband medical help activator with
built-in RF transmitter. It will transmit the radio signal to
the Main Controller if the button is pressed. Please keep
this device out of reach of children to avoid unwanted
trigger.
HK-SR868 Radio Signal Repeater
HK-SR868 is a radio signal repeater, which can be used to
relay the RF communication signal between system
devices and Main Controller. This device can be used to
extend the radio communication range for HomeKeeper.
HK-GSM30 GSM Communication Module
HK-GSM30 is a GSM communication module for
HomeKeeper to connect with GSM network. This device is
actually a working GSM mobile phone after insert a valid
SIM card.
HK-RS232 RS-232 Interface Module
HK-RS232 is a RS-232 interface module for HomeKeeper to
communicate with PC.
HK-BF450 Ethernet Interface Module
HK-BF450 is an Ethernet interface module for HomeKeeper
to hook on LAN (Local Area Network).

TM
6
3.2 MAIN CONTROLLER
Front view Side view
Top view
1. A
larm Output Selector: Select the alarm relay output as 12 VDC or dry contacts.
2. Terminal Block: Serial of terminal blocks for various wiring connections. Please
refer to the “EXTERNAL CONNECTIONS.
3. COM 1: Communication port for RS-232, Ethernet or GSM module. Please refer
to the “EXTERNAL CONNECTIONS”.
4. COM 2: Communication port for X-10 Power Line Interface controller. Please
refer to the “EXTERNAL CONNECTIONS”.
5. AUX Audio: Audio I/O for GSM module connection. Please refer to the
“EXTERNAL CONNECTIONS”.
Keypad and Status Display
: Key A& for AWAY mode
: Key B& for HOME mode
: Key C& for CLEAR and PAUSE
: Key D& for DISARM and ENTER
: Key 1 & for hand-free telephone
: Key 2 & for X-10 switching control
: Key 3 & for relay control
: Key 4 & for door open control (reserved)
: Key 5 & message in reading (refer to 8.1)

TM
7
3.3 STATUS INDICATIONS
3 LED indicators (red, yellow and green) on the front panel indicate various system statuses
with different ON-OFF-FLASH combinations as the following table shown.
LED
Status
Red
(AWAY)
Yellow
(HOME)
Green
(DISARM)
DISARM mode OFF OFF FLASH
HOME mode OFF FLASH OFF
AWAY mode FLASH OFF OFF
DISARM with warning message OFF ON FLASH
DISARM with alarm message ON OFF FLASH
DISARM with warning & alarm
message
ON ON FLASH
HOME with warning message OFF ON OFF
HOME with alarm message ON Flash OFF
HOME or AWAY with warning &
alarm message
ON ON OFF
AWAY with warning message FLASH ON OFF
AWAY with alarm message ON OFF OFF
Note: If there is any alarm or warning message in the event log memory, the ALARM (red)
and WARN (yellow) LED indicators will be lit. The indications can be reset after the
user runs the Event Check function (refer to the System Event Check section) or
pressing (hotkey) in Disarm mode.
3.4 DETECTORS/ZONES CATEGORIES
The HomeKeeper system can link up to 288 wireless detectors, each defined as a zone. All
detectors should be classified into five categories as below;
1. Remote Control Keyfob, KeypadC: Controller / Panic Devices.
2. Door/Window Sensor, Passive Infrared Detector, Glass Break Detector…etc. B:
Burglar Detectors.
3. Smoke Detectors, Gas Detectors F: Fire Detectors.
4. Medical Help Transmitter and Inactivity Detector M: Medical Help Transmitters.
5. Flood Detector, Temperature Sensor and Humidity Sensor. S: Special Detectors.
The system will automatically assign a category code (C, B, F, M, S) and a two double-digit
identification code (01-01 ~ 99-99) to all system devices linked. The category code
represents type of the device. The first two-digit is referred as “Group number” and the
second two-digit is referred as “Unit number”.
For example, C 01-02 represents the Controller of Group 01, Unit 02.B 02-04 represents
the Burglar detector of Group 02, Unit 04.

TM
8
For management and maintenance purpose, the system assigned device identification code
can be changed by installer while proceeding initial setup. User or installer can define their
preference group number as desired. Several devices can be grouped together.
Note: Group number 00 is reserved for the Main Controller.
4. INSTALLATION
4.1 MECHANICAL INSTALLATION
Placement of the Main Controller
It is important to ensure that the Main Controller is installed at place with good reception of
the RF signals transmitted from all system devices. The following notes should be taken into
consideration while selecting the location of Main Controller.
Try to place the Main Controller at the central area of the house or office.
Ensure that AC power outlet and telephone line (if needed) is available nearby.
DO NOT place the Main Controller nearby any large appliance or metallic objects.
DO NOT place the Main Controller at outdoors or where water may splash on.
1. Separate the Mounting Bracket from Main Controller by releasing the two flat head
screws.
2. Drill two mounting holes to fix the Mounting Bracket on wall.
3. Insert the plastic plug for screw mounting.
4. Attach the Main Controller to the Mounting Bracket and push up to hold the unit.
5. Fix the Main Controller and Mounting Bracket with the two flat head screws.
Installing System Devices
Before installing the system device, check the radio signal quality from the RSSI (Receiving
Signal Strength Indication) reading on the LCD by pressing the test button of the system
device (if available). Relocate the system device to obtain better RF reception is necessary.
Please refer to the respective installation instruction to install system device correctly.
DO NOT install system device on a metal surface as it will absorb the RF transmission and
result in shorter range.
4.2 ELECTRICAL INSTALLATION
1. Open the cover of back-up battery 2 compartments located at left bottom corner (face to
the back of the unit). Slide the battery switch to the ON position.
Note: The HomeKeeper Main Controller accommodates 2 rechargeable batteries. Battery 1
(9.6V/900mA) is built-in and battery 2 (9.6V, 600mA) is optional. If AC mains power fails,
the back-up batteries can supply system operation power up to 15 hours, depending
on the system load and effective capacity of the batteries.

TM
9
2. Plug in the AC power adaptor.
3. Enter the “INSTALLER” code (Default
INSTALLER code is “1234”) and access into
the INSTALLER SETTING mode (refer to the
Installer Setting mode).
4. Proceed the following system settings by
referring to the respective instructions.
A) Telephone number setting (refer to 6.2)
B) Voice message recording (refer to 6.3)
C) Wireless system device enrollment (refer to 6.4)
5. Set other functions if necessary (refer to the respective setting instruction).
6. Connect the telephone line, GSM module and/or Ethernet adaptor (if applicable) as this
manual and device’s installation instruction stated.
7. If Wireless Siren (optional) is installed, ensure to enroll the Main Controller into the
Wireless Siren (refer to 6.4 and instruction of the wireless siren).
8. Enter into “Master Mode” and set the system clock (refer to the 5.5 Master Mode –
Clock Setting).
9. Test other functions that have been set.
Note: Manufacturer strongly recommends the installer to complete all system settings
via “HyperSecureLink” by PC with the RS-232 interface module. All system settings
and programming can be done via “HyperSecureLink” much easier and faster.
5. USER OPERATIONS
5.1 OPERATION INTERFACE
The operation interface of HomeKeeper adopts user-friendly interactive programming
technique, so that all system settings and operations can be done easily. Just follow the
instruction on the LCD and answer YES or NO to the system by pressing the respective
button, you can complete most of the operations and programming of the HomeKeeper
system.

TM
10
Reading the LCD instruction
When LCD displays message with question mark (?), it means that you should press
the YES or NO button to answer. Ex. The LCD shows “Master Code?”, press YES
button to enter into the Master Mode or NO to deny the command.
If the LCD displays some number and follows by “Enter”, it means that you should
input the proper figure and then pressing the Enter (D) key. Ex. The LCD shows
“Seconds (0-255) Enter:” it means the system is asking you to enter the figure
between 0and 255, then press Enter (D) key to confirm. (If press 6, 4, and then Enter,
it means that you have set the time for 64 seconds).
To check the system function, press or key (same as YES and NO) to scroll the
screen up or down.
Reading the programming flow chart
In order to provide easy-to-understand description for all the programming procedures of
system operations, many programming flow charts are shown in this manual. Here we show
you how to read these flow charts.
5.2 OPERATION CODE (PASSWORD)
There are totally 14 operation codes (also refer as “PASSWORD”), each with maximum 8
digits, can be set to operate the Main Controller. Primary user (normally the property owner)
should record all details of every operation code (including code type, user’s name,
authorized date…etc) at secured place to prevent confusion in the future.
1 x Master Code (user 1, default “0000”)
This is the most important operation code of the HomeKeeper system. It has the highest
priority which allows primary user to manage other user codes and system settings.
7 x General User Codes (user 2 – 8)
These codes are available for 7 general users who are authorized to arm/disarm the system
and check the system status.
State A State A-1
State A-2 Sub-state of State A-2
State A-3
Down arrow () in all flow charts means selecting the next state. Right arrow () means
entering into the sub-state of current state.
Note: To exit the current state, pressing FUNC/ESC key at anytime.

TM
11
2 x Latchkey User Codes (user 9 & 10)
When enter any one of these two codes to arm or disarm the system, the HomeKeeper will
dial the Latchkey Number (refer to 6.2.1 Setting Telephone Number-Latchkey number) to
report the operation.
1 x Duress Code (user 11)
If user enters this code to disarm the system, the HomeKeeper will dial and send the duress
signal to the CMS.
1 x Installer Code (default “1234”)
This code authorizes user or installer to enter into the Installer Mode for more system
settings.
2 x CMS Codes (CMS1 default “1111”, CMS2 default “2222”)
These two codes authorize CMS providers to set CMS parameter and execute system check.
5.3 INITIAL STATE
Once the system is first time powered, the LCD will display SYSTEM RESET and indicate the
time data of power on reset. Operator can key-in “0000DC” to clear the display to clear the
display and enter into the Initial State.
By entering correct code, user can execute System Check, Hot Key control function or
enter into Master, Installer or CMS modes.
Initial State
Master or User Code Other Codes
Hot Hey Enter
Hot Key Process System Check or Hot Key? System Check?
Yes No Yes No
System Check Master Mode Installer Mode CMS Mode
(refer to 5.4) (refer to 5.5) (refer to 5.6) (refer to 5.7)
Hot Key : The following keys allow user to enter into specific operation mode directly.
Enter AWAY Mode.
Enter HOME Mode.
Clear LED/LCD display, reset siren and stop dialing immediately.

TM
12
Message in reading (refer to 8.1)
AWAY, HOME & DISARM Modes - refer to the OPERATION MODES
The ARM Mode in this manual means AWAY or HOME Mode.
5.4 SYSTEM CHECK
System Check Event Check Check By Sequence
Check By Date
Telephone Number Check (5.4.1)
Voice Check (5.4.2)
Device Check (5.4.3)
5.4.1 Event Check
The Main Controller can store up to 512 system operation events. These events can be
checked either by time sequence or entering the date. Use or key to scroll the
log up or down.
Reading Event Check Display
LCD shows Description
C02-03 Disarm
04/26 22:08 01
Remote Control Keyfob #02-03 disarmed the system
at 22:08 on April 26th. 01 means this is the latest event.
B01-02 Burglar
01/02 19:32 253
Burglar Sensor #01-02 reported an alarm signal at
19:32 on January 2nd. This is event #253.
Enter DISARM Mode & reset siren.
Enter hands-free Telephone Mode. The Main Controller can be used as
a hands-free telephone for 10 minutes once entering this mode. Press
ESC to disconnect and return to normal operation mode.
X-10 switch control (X-10 switch control module is an optional device).
Close or open the alarm relay terminals on the rear panel.
Open the door (door lock controller is an optional device).

TM
13
5.4.2 Telephone Number Check
This operation can verify the telephone numbers stored in the memory and their
answering types. To know the usage of different telephone numbers, please refer to the
section “Setting Telephone Number”.
Telephone Number Check Common 1 Number
Common 2 Number
Common 3 Number
Common 4 Number
Panic Number
Burglar Number
Fire Number
Medical Number
Special Number
Latchkey Number
Pager Number
Pager Data
Reading the Telephone Number Display
If the telephone number is more than 16 digits, it will be displayed in two rows on the
screen. Press key to check the rest part of the number.
Common 1
123456789012345 -
Press Common 1
- 6789V
Press Common 2
222222222T
Above example shows the Common 1 telephone no. is 1234567890123456789 and
answered by Voice (V). The Common 2 telephone number no. is 222222222 and
answered by Tone (T).
5.4.3 Voice Check
Voice Check operation allows user to play-back the pre-recorded voice messages
under various conditions. For the usage of different voice messages, please refer to the
section “Set Sound”.

TM
14
Voice Check All Voice
Common Segment
Panic Segment
Burglar Segment
Fire Segment
Medical Segment
Special Segment
Latchkey Disarm Segment
Latchkey Away Segment
5.4.4 Device Check
This operation allows user to check the status of all devices. Using and keys to
scroll the display screen up and down.
Device Check Controller
Burglar Sensor
Fire Sensor Check By sequence
Medical Button Check By Zone Number
Special Sensor
Reading the Device Status Display
LCD shows Description
Remote Ctl. 02
C01-02 Normal
Controller #2 is a Remote Control Keyfob. Zone number is
01-02. Status is normal.
Mag. Sensor 07
B10-12 Trouble
Burglar Sensor #7 is a Magnetic Sensor. Zone number is 10-
12. Status is trouble. (Go to System Check-Event Check to
check the trouble)

TM
15
5.5 MASTER MODE
Master Mode Set Bell Door Bell On
Device Test Door Bell Off
Monitor Mode (Only can be entered in Disarm Mode)
Set Partial ARM
Set Entry Delay (Refer to Set Timer- Set Entry Delay)
Set Exit Delay (Refer to Set Timer- Set Exit Delay)
Set Clock Time Date Day
Set Switch Set House Code
Set X-10 SW Auto Control
Set Relay Auto. Control
Set Password Master
User 2
User 3 ~ User 7
User 8
User 9, (Latchkey User)
User10, (Latchkey User)
User 11(Duress Code)
Bell ON/OFF (default ON)
This setting is to enable/disable the door chime output in disarm mode.
Bell ON: The Main Controller will generate a doorbell sound (Ding! Dong!) when Burglar
sensor detects intruder in Disarm mode, if the Bell ON/OFF function is set ON.
Bell OFF: No doorbell chime will sound if the Bell ON/OFF function is set OFF.
Note: This function only works for the Burglar Sensor whose Bell ON/OFF status is set ON
(Refer to 6.4.1Change Device Setting-Burglar Sensor-Enable State-Bell ON/OFF)

TM
16
Device Test
The system will initiate a 5-minute test period for user to test the functions of all system
devices (not include Remote Control Keyfob). During device test period, the Main Controller
will only sound beep when it receives signal from any system device. When test period
expired, the system will return to its original mode automatically. The system will escape
from the Device Test mode immediately when it receives Arm/Disarm command signal.
Monitor Mode
The purpose of this mode is to monitor all activities occurred in the designated areas during
Disarm Mode. In monitor mode, any trigger signal from Burglar Sensor (except the sensors
assigned in group 91 ~ 99 Partial Arm Zone) will be recorded only as a trigger signal in the
Event Log, no alarm output will be issued. The system will escape from the Monitor mode
immediately when it receives Arm/Disarm command signal.
Set Partial Arm
Group 91 to 99 are 9 independently protected zones. These zones can be separately
armed/disarmed.
Set Switch
Set House Code <A-P>: (default <A>)
This code should be the same as the House Code set on the X-10 switches, user can
select code from A to P.
Set X-10 SW Auto Control
Set the X-10 switch working schedule for home automation applications. Please refer
to the X-10 device operation instruction.
Set Relay Auto Control
Set the operation schedule of alarm Relay.
Entry Delay: Refer to Installer Mode - Entry Delay.
Exit Delay: Refer to Installer Mode - Exit Delay.
Set Password
Latchkey User
User 9 and User 10 are also called Latchkey Users. The HomeKeeper will dial the
Latchkey Number (Refer to Set Telephone Number- Latchkey Number) when these
users arm or disarm the system.
Duress Code (reserved): This code is used to notify the CMS (Central Monitoring
Station) that a duress situation has occurred and user requires immediate assistance.
This code is normally used under duress condition, while user does not want to alert
the intruder about the fact of calling for help. When duress code is once entered,

TM
17
the system will be disarmed and a duress signal will be sent to the CMS
immediately. Once receiving the duress signal, the CMS can response the
situation without contacting the user.
5.6 OPERATION MODES
The HomeKeeper system provides three different protection modes to fulfill different
requirements and situations.
5.6.1 AWAY Mode
When user leaves the protected premises, the AWAY mode is set to provide total
protection. During AWAY mode, the system will generate an alarm condition if Main
Controller receives signal from any sensor that are set on duty.
Set AWAY Mode from Main Controller
To enter the AWAY mode from Main Controller keypad operation, just pressing Hot
Key A and then system will initiate the exit delay. The system will enter into AWAY
mode after the exit delay expired.
Set AWAY mode from Remote Control Keyfob
To enter the AWAY mode from Remote Control Keyfob, just pressing the AWAY
button and then system will enter into the AWAY mode immediately.
Note: Exit delay is a period of adjustable time (0 ~255 seconds) that allows user to
leave the premises without activating the alarm.
Note: If any door or window is left open while setting the HomeKeeper into AWAY
mode, the Main Controller will generate a warning message by showing the zone
number on the LCD display and automatically insert additional 20 seconds Exit Delay
if no Exit Delay has been set. Close the door or window so that the system can enter
into the AWAY mode.
5.6.2. HOME Mode
HOME mode provides the partial protection required by user while staying at home.
Under this operation mode, the HomeKeeper will report an alarm condition if any
HOME mode active Burglar Sensor (ENABLE STATE-HOME MODE-ACTIVE)
detects intruder.
Set HOME Mode from Main Controller
To enter the HOME mode from Main Controller keypad operation, just pressing Hot
Key B and then system will initiate the exit delay. The system will enter into HOME
mode after the exit delay expired.

TM
18
Set HOME mode from Remote Control Keyfob
To enter the HOME mode from Remote Control Keyfob, just pressing the HOME
button and then system will enter into the HOME mode immediately.
Note: When you set the HomeKeeper system in Home Mode, the Main Controller will
check the status of all Door/Window Sensors. If any of the sensors is open, the Main
Controller will issue a warning message and display the zone number of opened
sensor on the LCD display for user to check.
5.6.3 DISARM Mode
DISARM mode is normally used when user stays in the premises. During this mode,
the HomeKeeper will not issue any alarm condition by Burglar Sensors, but all 24-
Hour Zone Sensors, Fire Sensors, Panic and Medical Help Button will still work.
Set DISARM Mode from Main Controller
To enter the DISARM mode from Main Controller keypad operation, just pressing Hot
Key D and then system will initiate the entry delay. The system will enter into DISARM
mode after the entry delay expired.
Set DISARM mode from Remote Control Keyfob
To enter the DISARM mode from Remote Control Keyfob, just pressing the DISARM
button and then system will enter into the DISARM mode immediately.
5.7 ALARM REACTIONS
The HomeKeeper system will react to various alarm and abnormal condition as the following
table shown. Burglar alarm can only be activated when the system is set at HOME or AWAY
mode, while Fire, Panic and Medical alarms can be activated at anytime under any operation
mode. When any of the alarm condition occurs, the Main Controller will dial the designated
number stored to call for help.
Alarm Reaction Table
Note 1: Pressing the buttons on the unit will neither send out the voice message nor trigger
the alarm, despite of being assigned as Panic or Medical.
Burglar Alarm Response
AWAY Mode Entry Delay Burglar Alarm →
↑(0-255 seconds) ↑
System status: Burglar sensor triggered Siren goes off, dialing---

TM
19
TO STOP TELEPHONE DIALING AND SIREN OUTPUT
If necessary, the user can interrupt the telephone dialing and stop the siren output by
disarming the system (entering correct code), and clear the alarm LED/LCD indication by
pressing the Hot Key C
5.8 ANSWERING PHONE CALL FROM HOMEKEEPER
When you receive phone call from HomeKeeper, you can communicate with the system by
operating as follow.
When pick up the phone, your voice on the line will activate the message recorded in
the HomeKeeper for the telephone number assigned as voice acknowledgement.
You will hear the message twice, reporting the alarm event happened to the system.
After the message stop, the HomeKeeper enters the monitoring mode for 60 seconds.
You can hear the sound from your premises via microphone built-in the HomeKeeper or
talk to the people over there.
During the 60-second monitoring mode, you can also remotely control your
Sources &
Reaction
Alarm
Type
Alarm Trigger
Sources
Dialing
Telephone
Numbers
Besides CMS
Voice message
segment
on Telephone
Voice from
the Main
Controller
Siren Status
Burglar PIR Detector
Door/window
sensor
Glass Break
Detector
Pager+ Burglar+
Common 1- 4
Sequentially
Burglar &
Common
Silent Programmable
Fire Smoke Detector
Gas Detector
Pager+ Fire+
Common 1- 4
Sequentially
Fire &
Common
Play Fire
Message,
Programmable
Programmable
Panic Panic Button of
Remote Control
Keyfob
Wireless Keypad
Pager+ Panic+
Common 1- 4
Sequentially
Panic &
Common Silent Programmable
Medical Wireless Medical
Button
Medical Button on
the Main Controller
Pager+ Medical
+ Common 1-4
Sequentially
Medical &
Common
Play Medical
Message,
Programmable
Programmable
Special Temperature
Sensor
Humidity Sensor
Flood Detector
Pager+ Special
+ Common 1-4
Sequentially
Special &
Common
Silent Programmable
Disarmed Mode
NO NO Silent Programmable
Tamper
Main Controller
PIR Detector
Door Sensor
Glass Break
Detector
Wireless Keypad
Armed Mode
Same As Burglar Alarm
Low Battery PIR Detector
Door Sensor
Glass Break
Detector
Smoke Detector
Wireless Medical
Help Button
Other Sensors
NO
NO
Silent
OFF

TM
20
HomeKeeper via local telephone keypad operation.
Press 0 : Disconnect the HomeKeeper immediately. Stop dialing and siren.
Press 1 : Disconnect the HomeKeeper immediately. Dial the next number.
Press 3 : Enter into speak-only mode. (The microphone of HK-MC868 is disabled.)
Press 5 : Enable 2-way hand-free speaker communication.
Press 8 : Enable listen-only monitoring
Press any other key: Extend the connection for another 60 seconds.
Note: The sound of siren or background noise may affect the decoding of remote control key
tone input, so keep pressing the key until the command is accepted.
Note: If the phone number requires a DTMF tone acknowledgment, remember to press a key
on the telephone keypad while answering the call from the HomeKeeper to prevent it
redialing the number again.
Answering Sequence
HomeKeeper Voice Message Monitoring &
Dialing Playback Communication
Twice for 60 seconds
Ring!---Ring!
Answered by voice (“hello”)
or press a DTMF key
5.9 DIAL-IN CONTROL
Dial-in Control means that you can control and check status of your HomeKeeper via a
phone anywhere in the world. This function is available if auto-answer function (refer to
(4-2) Set Telephone – Set Auto Answer) and ring count number are both set.
Note: If you connect a fax machine or answering machine on the same telephone line,
please refer to their manuals and Section 8.7 to avoid any improper operation.
Note: The ring count number should be set more than 3, otherwise, the telephone line noise
0: Disconnect and stop further dialing & siren.
1: Disconnect and dial the next number.
3: Enter into speaker-only mode.
5: Enable 2-way speaker communication.
8: Enable listen-only monitoring.
X: Press any other key to extend connection for
another 60 seconds.
Table of contents
Popular Security System manuals by other brands

Trust
Trust SECURITY PLUS-LINE ALSIR-2000 user manual

Wheelock
Wheelock RX-1419 installation instructions

XMark Fitness
XMark Fitness Securaband 804A2401 user guide

Honeywell Home
Honeywell Home Ademco Vista-V21SIALTE Installation and setup guide

Steren
Steren ALA-170 quick start guide

bioscrypt
bioscrypt V-Flex 4G installation guide