Isel iPC15 User manual

isel
Germany AG, D-36124 Eichenzell, Bürgermeister-Ebert-Str. 40 (06659)981-0 (06659)981-776
iPC15
Operating Instruction

The information, technical data and dimensions contained in this print have been up-to-date
when published. Any eventually existing misprints and mistakes cannot be excluded however.
We are thankful for any suggestion for improvement and indication of mistakes.
Please note that the used software- and hardware descriptions of each individual company are
generally subject to protection of trademarks and patent law.
All rights reserved. It is not permitted to reproduce or electronically process, duplicate or spread
any part of our prints in any way (print, copy etc.) without written permission of isel Germany
AG.
Manufacturer: isel Germany AG
Bürgermeister-Ebert-Straße 40
D-36124 Eichenzell
Tel.: (06659) 981-0
Fax: (06659) 981-776
http://www.isel.com
Status: 07/2010

Table of contents
1Introduction.........................................................................................................................1
1.1 Safety symbols ............................................................................................................... 1
1.2 Sicherheitshinweise........................................................................................................1
2Product description.............................................................................................................2
2.1 Technical data ................................................................................................................2
2.2 Connectors / Interfaces iPC15........................................................................................3
3Mounting and operation.....................................................................................................5
3.1 Mounting dimensions.....................................................................................................5
3.2 Mounting........................................................................................................................6
3.3 Switch on iPC15.............................................................................................................6
4Maintenance and cleaning..................................................................................................7
5EC Declaration of Conformity...........................................................................................8

iPC10 / iPC20 Operating instruction
Page - 1
1Introduction
1.1 Safety symbols
Attention
This symbol signalizes that there is danger for peoples life und health.
Danger
This symbol signalizes that there is danger for material, machine and
environment.
Information
This symbol signalizes important information.
1.2 Sicherheitshinweise
The Control PC’s iPC15 are designed to current technical and recognized
rules.
The device may only be used if it is in correct condition. Any faults have to
be eliminated immediately. Neither children nor non-authorized persons are
allowed to put the device into operation.
The device may only be used for the intended use.
All work on the module must be executed from authorized personal
regarding electrical industry rules and accident prevention regulations.
Assembly and use of operating material has to be according to the standards
of conformity declaration. In case of in proper use even the observation the
respective rules and standards does not protect against physical damages and
damage to property.
Do not expose the device to high humidity or high vibrations.
Please take care of the instruction manual. Be sure that all users know the
instructions.
Ignoring the instruction manual can lead to damage, heavy physical damage
or to death.

iPC10 / iPC20 Operating instruction
Page - 2
2Product description
2.1 Technical data
iPC15
dimensions (L x H x W):
190 x 51,5 x 200 mm
weight:
1,1 kg
ambient temperature:
0°C - 50°C
humidity:
max. 90% not condensing
safety class:
IP20
power supply voltage:
12 VDC/min. 60W (external power supply unit 12V/ 60W)
intended use:
Industrial area / home- office area
form factor:
Mini-ITX
CPU:
Intel®ATOM N270 1,6 GHz
memory (RAM):
DDR2-RAM 1GB
hard disk:
2,5“ HDD 160GB, SATA
operating system:
Windows Embedded POSReady 2009
connectors:
1 x VGA (On Board)
3 x USB 2.0
1 x LAN 1GBit
1 x Audio Out
1 x DVI
optional connectors:
1 x CAN control card PCI (iCC10, iCC20)
1 x COM port
1 x LPT
1 x SubD9-pin female connector for iBP10 / iBP17

iPC10 / iPC20 Operating instruction
Page - 3
2.2 Connectors / Interfaces iPC15
Nr.
Schnittstelle
1
Connector for power supply 2-pin plug, use with external power supply unit
12 VDC/60W power supply voltage
2-lead wire (+12VDC yellow / GND black) for power supply, use on control
cabinet mounting
12 VDC/60W power supply voltage
Please note that only one connector is used for power supply.
2
VGA
Connector 15-pin VGA monitor
3
DVI
Connector for DVI monitoring devices
4
USB ports
3 x USB 2.0 ports for peripheral USB devices
5
LAN
1x RJ45 connector for Ethernet network
6
Sound-On-Board
connector for sound line out
7
PC-Start button
Switch On/Off iPC, green lighting signalizes powered state of the computer
8
Serial Interface COM1, Sub-D9-male (optional variant)
Connector for a serial interface, type RS232
9
additional USB slot (optional variant)
1 x USB 2.0 ports for peripheral USB devices

iPC10 / iPC20 Operating instruction
Page - 4
10
isel-CAN-interface card iCC10 / iCC20 (optional variant)
Integrated CAN-PCI- interface card with RJ45 connector to communicate with isel
CAN bus components (e.g. IMDxx, CAN-IO-XX/XX).
The Windows hardware driver for the CAN-PCI card is
included on the ProNC/Remote installation medium. Normally
the driver files will be installed during initial operation of the
iPC15.
LPT connector (optional)
SubD25-pin socket, printer port
SubD-9-pin female for connection of iBP10 / iBP17
(only control cabinet mounting)
Pin
Function
Description
1
PWR BTN +
Connector for Power button +
2
PWR BTN GND
Connector for Power button GND
3
PWR LED +5VDC
Connector for RUN status LED +
4
PWR LED GND
Connector for PWR status LED GND
5
HDD LED +5VDC
Connector for HDD activity LED +
6
+12VDC
Power supply for LCD monitor +12V
7
GND
Power supply for LCD monitor GND
8
n.u.
9
HDD LED GND
Connector for HDD activity LED GND

iPC10 / iPC20 Operating instruction
Page - 5
3Mounting and operation
3.1 Mounting dimensions
Dimension drawing iPC15

iPC10 / iPC20 Operating instruction
Page - 6
3.2 Mounting
For mounting the iPC15 use the mounting holes on the cover plate.
Using iPC15 with isel 22“ TFT display
When using the iPC15 with a isel
22” TFT display the mounting is
done by a rack mount on the back
side of the TFT display.
Note that there is enough free zone on the louvers for air circulation. Ignoring
this fact causes overheat and potential defect of the iPC
Please avoid extreme environment conditions. Protect the control PC for dust,
humidity and heat. Do not cover the louvers!!
3.3 Switch on iPC15
Switch on iPC15 by pressing the PC-start button on the front side of the computer (see also
Chapter: 2.2) ore use the contacts of the Sub-D9-pin female connector.
If iPC15 is switched on the PC-start button is green lighted (not on
version for control cabinet).

iPC10 / iPC20 Operating instruction
Page - 7
4Maintenance and cleaning
Maintenance
The computer iPC15 are maintenance free.
Cleaning
Switch off iPC15 and all connected components. Remove the power supply
voltage connection.
Use a wet, soft cloth to clean the case. Don’t use cleaning agents or abrasives.
Be sure that no moisture comes into the case.

iPC10 / iPC20 Operating instruction
Page - 8
5EC Declaration of Conformity
EC - Declaration of Conformity
Der Hersteller
The manufacturer
isel Germany AG
Bürgermeister-Ebert-Str. 40
D-36124 Eichenzell
erklärt hiermit, dass folgendes Produkt
hereby declares that the following product
Geräteart: Industrie PC
Device: industrial PC
Typ: iPC15
Type: iPC15
Art.-Nr.: 371064 000x
Product - No.: 371064 000x
mit den Vorschriften folgender Europäischer Richtlinien übereinstimmt:
complies with the requirements of the European Directives:
EG-Richtlinie 2004/108/EG
EC-Directive 2004/108/EC
EMV Richtlinie
EMC directive
EG-Richtlinie 73/23/EWG
EC-Directive 73/23/ECC
Niederspannungsrichtlinie
low voltage directive
Folgende harmonisierte Normen wurden angewandt:
Following harmonized standards have been applied:
EN 61000-6-2:2005
EMV - Fachgrundnorm - Störfestigkeit für Industriebereich
EMC - Generic standards - Immunity for industrial environments
EN 61000-4-2:2007
EMV - Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Entladung
statischer Elektrizität (ESD)
EMC - Testing and measurement techniques; Electrostatic discharge immunity test
EN 61000-4-4:2004
EMV - Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen schnelle
transiente elektrische Störgrößen (Burst)
EMC - Testing and measurement techniques - Electrical fast transient/burst immunity test
EN 61000-4-5:2006
EMV - Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen energiereiche
Impulse (Surge)
EMC - Testing and measurement techniques - Surge immunity test
EN 61000-4-11:2004
EMV - Prüf- und Messverfahren - Prüfung der Störfestigkeit gegen Spannungs-
einbrüche / Spannungsunterbrechungen
EMC - Testing and measurement techniques - Voltage dips, short interruptions and voltage
variations immunity tests
EN 61000-6-4:2007
EMV - Fachgrundnorm - Störaussendung Industriebereich
EMC - Generic standards - Emission standard for industrial environments
DIN EN 55011:2007
Industrielle, wissenschaftliche und medizinische Hochfrequenzgeräte (ISM-Geräte) -
Funkstörungen - Grenzwerte und Messverfahren
Industrial scientific and medical (ISM) radio-frequency equipment - Electromagnetic
disturbance characteristics - Limits and methods of measurement
Dermbach, 13.01.2009
__________________________
Hugo Isert, Vorstandsvorsitzender / chairman
Table of contents
Other Isel Control Unit manuals
Popular Control Unit manuals by other brands

RKC INSTRUMENT
RKC INSTRUMENT Z-TIO-G instruction manual

WAGO
WAGO I/O-SYSTEM 750-597 manual

Danfoss
Danfoss AMZ 112 installation guide

Rehau
Rehau NEA Installation and operating manual

IFM Electronic
IFM Electronic Ecomat 300 AL1030 Device manual

Emerson
Emerson FRM-2 Installation, operation and maintenance instructions