Iseo X1R Smart User manual

X1R Smart
INSTALLATION GUIDE
WARNINGS
ELECTRONIC SUPPORT SERVICE
iseozero1.com
®
iseo.com
Iseo Serrature s.p.a
Via San Girolamo 13
25055 Pisogne (BS)
ITALY
Tel. +39 0364 8821
[email protected]
Download
Download
User Manual
Iseo Argo App
app.iseo.com
When you switch on X1R Smart for the first time,the lock automatically updates, if necessary, connected devices: external and
internal control modules and the Bluetooth radio module. This operation can take up to 50 seconds and it is indicated by the orange
led on the external module continuously flashing. Do not switch off X1R Smart during this operation and do not press any button
or disconnect any cable, in order to avoid device malfunctions.
Read this manual prior to use the device in order to ensure a safe and proper use.
Preserve this manual as future reference.
The installation of the device requires the intervention of qualified staff, adequately trained by ISEO.
The instructions should be carefully followed during installation. These instructions and any maintenance instructions should be
passed on by the installer to the user.
The product can be destined only for the use for which it was expressly made and, therefore, as an armored door lock for civil and industrial
locations. Any other use is to be considered improper and dangerous.
Do not work on the door with the lock installed in order to prevent wood or metal residue getting into the lock.
Distance between striking plate and latch tip, completely in (from both motor or key), must be between 2 and 3mm.
Handle must not have any friction during the return phase.
Connecting rods must have a play of at least 1 millimeters so that the deadbolt does not remain subjected to traction in the rest
position. This would compromise infact the latch to be correctly relased when recalled by key.
Connect the “remote opening command” input to 8÷30Vdc/ac power supply source (opto-insulated input).
To use the “door status” internal relay (30Vdc/Vac - 1A MAX), an external power supply source is mandatory. Fit therefore a cable gland to
allow the cable to pass through the hinge side of the door
Electrical connections must be done according to the manufacturer’s istructions and in compliance with the current regulations.
When using a feeder as a direct power supply source (8÷30Vdc/ 30W MAX), fit a cable gland to allow the cable to pass through the hinge
side of the door.
Single Action version allow to withdraws bolts and latch by handle at the same time. Standard version allow to withdraws only the latch by
handle.
ISEO Serrature S.p.A.
Via S. Girolamo, 13
25055- Pisogne – BS Italy
0497/CPR/ 5706
17
EN14846:2008
|3|X|9|E|0| P|7|1|3|
0497/CPR/5705
17
EN179:2008
|3|7|7|B|1|4|5|2|A|B|
DoP & Declaration of conformity available on the web site http://www.iseoserrature.it
x1R 696
x1R 699 SA
x1R 699 SA
1. DIMENSIONS
22 min18 min
38
23
106156
9286
136
63
91,5
8
L
49 59
25
20
18
85
56
corsa 30
corsa 15
42 max.
38 max.
0min - 33max
15
3
n.4 x
6
= =
= =
373737
30
262
40
14,2
39,2
28 28 28 28
410
35
164
65
= =
n.3 x M5
L
3
8
12
13
21
31
33
262
108
n.2 x M6
To find all available versions and related
codes, check the IseoZero1 catalogue.
Add the plug indicated in the picture
below only for Single Action version.
2. VERSIONS
3. LATCH REVERSIBILITY AND ADJUSTMENT
1
2
Only if latch version ≤13mm.
Max latch projection adjustment:
+ 6mm.
+
-
+
-
LATCH ADJUSTMENT
4. DOOR CONTACTS REVERSIBILITY AND ADJUSTMENT
It is forbidden to lubricate the door
contacts.
It is possible to use ethyl alcohol to
clean the door contacts.
1
2
+
-
+
-
5. CYLINDER FIXING
min 39.3 max 39.6
min 6.2 max 6.6
The x1R Smart lock works
correctly when using cylinders
with standardised profile cams of
the size indicated in the above
drawing.
When used with cylinder with
knobs, make sure that after the
cylinder has been turned the cam
does not remain engaged, which
will cause the motor to rotate in
neutral.
1
2
6. DOOR CLOSED CONTACTS FIXING
21,5
43
54
3.5 mm
TOP
BOTTOM
black
red
In the case of power supply via door
contacts, use an external power
supply: 8÷30Vdc (30W).
Low voltage contacts. Do not
touch with your fingers. Do not
connect to power supply that
exceed the indicated ones.
Respect power polarity.
It is forbidden to lubricate the door
contacts.
It is possible to use ethyl alcohol to
clean the door contacts.
7. EXTERNAL SIDE DOOR ASSEMBLING
External control module assembling on the external panel
=
50
50
25
25
50
330 max
93
Make a 50 mm diam. hole
only in the external panel in
order to install the external
cylinder protection.
Make a 25x25 mm slot in
the outside panel and plate,
to allow the external module
cable to pass through.
Keyboard with
RFID reader
Only RFID
reader
7.1 INTERNAL SIDE DOOR ASSEMBLING
Internal control module assembling on the internal panel
=
50
50
200 max
93
Internal control module is not
necessary if Single Action
version.
Opening and
closing buttons
8. INSTALLATION EXAMPLES
Batteries power supply +
External power supply (optional)
1
2
3
6
5
7
4
8
1
2
5
4
3
Internal side
External power supply +
Backup batteries (optional)
1. x1R Smart lock
2. Control module (only for
Standard version)
3. Alkaline batteries
4. Power supply 8-30Vdc/30W
5. Cable gland
6. Bipolar cable connection for
remote opening command
7. Bipolar connection cable kit
8. Multifunction connection
cable 8 pins.
9. BATTERY HOLDER HOUSING
84
38
110
min.
250
Before powering the x1R Smart make sure the red and black wires are
intact and the battery housing connector does not come into contact with
the door frame in any way.
alkaline
10. ELECTRICAL CONNECTIONS
OPEN
internal module external module
remote opening command
NA (not supplied).
8÷30Vdc/ac
To know more about the
connections of the 8 pins
multifunction cable and X1R
Smart as actuator, refer to
the user manual, available
at link “app.iseo.com”.
keyboard and RFID reader cable
Bluetooth radio cable
8 pins multifunction cable
male connector
(back side/wires view)
8765
4321
Color
Green
Orange
Black
Brown
Yellow
White
Red
Blue
Description
1
2
3
4
5
6
8
7
Relay common contact*
Relay normally open contact*
Negative power supply
Opening command 8÷30Vdc/ac
Relay normally closed contact*
Not used
+ Positive power supply 8÷30Vdc/30W MAX
Opening command 8÷30Vdc/ac
brown (4)
blue (8)
alkaline
* Relay: 30Vdc/Vac - 1A MAX
Only to use X1R Smart without external reader and keyboard (functioning as an actuator): place the
jumper, available in the package, in the PINs 1 and 2 of connector JP1. Take care the jumper is perfectly
and securely fitted into the PINs.
Non contractual document. Subject to change. Cod. 6000006990013.3 - 23/08/2017
X1R Smart installation guide (UK)
- © 2017 Iseo Serrature S.p.a. - www.iseo.com
Connettore JP1:
PIN 1 e 2 chiusi dal jumper

Other manuals for X1R Smart

3

Other Iseo Lock manuals

Iseo LIBRA User manual

Iseo

Iseo LIBRA User manual

Iseo Zero1 Series User manual

Iseo

Iseo Zero1 Series User manual

Iseo Boxer Guide

Iseo

Iseo Boxer Guide

Iseo Zero1 User manual

Iseo

Iseo Zero1 User manual

Iseo X1R Smart User manual

Iseo

Iseo X1R Smart User manual

Iseo Zero1 Aries User manual

Iseo

Iseo Zero1 Aries User manual

Iseo KW13771 Installation guide

Iseo

Iseo KW13771 Installation guide

Iseo F9000 ON/UP User manual

Iseo

Iseo F9000 ON/UP User manual

Popular Lock manuals by other brands

DAccess Security Systems ML10 Series manual

DAccess Security Systems

DAccess Security Systems ML10 Series manual

Häfele DT 600 installation instructions

Häfele

Häfele DT 600 installation instructions

Targus DEFCON CL Ultra Max ASP02AP user guide

Targus

Targus DEFCON CL Ultra Max ASP02AP user guide

ZKTeco Padlock user manual

ZKTeco

ZKTeco Padlock user manual

DITEC LIN2B installation manual

DITEC

DITEC LIN2B installation manual

Audiovox PRO-PDL-2B installation instructions

Audiovox

Audiovox PRO-PDL-2B installation instructions

Burg Wächter 610/53 operating instructions

Burg Wächter

Burg Wächter 610/53 operating instructions

COMPX C8142 Dimensional drawing

COMPX

COMPX C8142 Dimensional drawing

Stock Loks C8726 instruction sheet

Stock Loks

Stock Loks C8726 instruction sheet

AMSEC BSL-0601A-W Operating and installation instructions

AMSEC

AMSEC BSL-0601A-W Operating and installation instructions

Vinz BIS787 Series instruction manual

Vinz

Vinz BIS787 Series instruction manual

Paxton PaxLock Pro Installation and commissioning guide

Paxton

Paxton PaxLock Pro Installation and commissioning guide

Milwaukee KR-120M user guide

Milwaukee

Milwaukee KR-120M user guide

Häfele LockerLock LL 200 installation instructions

Häfele

Häfele LockerLock LL 200 installation instructions

IMMAX NEO LITE LOCKIN quick start guide

IMMAX

IMMAX NEO LITE LOCKIN quick start guide

Plasticase NANUK TSA POWERCLAW manual

Plasticase

Plasticase NANUK TSA POWERCLAW manual

Rousseau L13-OC20S Assembly guide

Rousseau

Rousseau L13-OC20S Assembly guide

Yale Smart Latch 2 manual

Yale

Yale Smart Latch 2 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.