
7
6.4.2.2 VolumeoverTimeMode
VolumeoverTimeModeallowstheusertodispenseadesiredvolume
overadesiredtime.Thepumpwilldeterminethespeedofrotationby
setvolumeandtime.Adjustableparametersarerotationdirection,
volume,volumeunits,time,andtimeunits.Rotationdirectioncanbe
selectedasCWorCCW.Combinationsoftimeandvolumecanbesetto
anyvalueaslongasitisintherangeofthepump’scapabilities.Ifthe
timevalueenteredislessthanwhatthepumpiscapableoffordesired
volume,itwilldefaulttotheshortestdispensetimepossible.Volumeunitsselectableareµl,mlandL.
Timeunitsselectableareseconds,minutesandhours.Noneoftheparametersarechangeableduring
pumpingorwhenoperationispaused.Dispensingprogramcanberesetduringoperationbypressing
theResetbuttonafterpumpingispaused.
6.4.2.3 VolumeMode
VolumeModeallowstheusertodispenseasetvolumewithasetflow
rate.Adjustableparametersarerotationdirection,flowrate,flowrate
units,volume,andvolumeunits.Rotationdirectioncanbeselectedas
CWorCCW.Flowratecanbechangedintherangespecifiedbythe
selectedunitand/ortubingID(seeSection6.4.3).Selectableflowrate
unitsareRPM,µl/min,ml/minandL/min.Selectablevolumeunitsareµl,
mlandL.Onlyflowratecanbechangedduringpumpingorwhenthe
operationispaused.DispensingprogramcanberesetduringoperationbypressingtheResetbutton
afterpumpingispaused.
6.4.2.4 TimeMode
TimeModeallowstheusertodispenseforasettimedurationwithaset
flowrate.Adjustableparametersarerotationdirection,flowrate,flow
rateunits,time,andtimeunits.RotationdirectioncanbeselectedasCW
orCCW.Flowratecanbechangedintherangespecifiedbytheselected
unitand/ortubingID(seeSection6.4.3).Selectableflowrateunitsare
RPM,µl/min,ml/minandL/min.Selectabletimeunitsaresec,min,and
hours.Onlyflowratecanbechangedduringpumpingorwhenthe
operationispaused.DispensingprogramcanberesetduringoperationbypressingtheResetbutton
afterpumpingispaused.
6.4.2.5 VolumewithPauseMode
VolumewithPauseModeallowstheusertodispenseasetvolumeover
multiplecycles.Adjustableparametersarerotationdirection,flowrate,
flowrateunits,volume,volumeunits,pausetimebetweencycles,pause
timeunit,andnumberofcycles.Rotationdirectioncanbeselectedas
CWorCCW.Flowratecanbechangedintherangespecifiedbythe
selectedunitand/ortubingID(seeSection6.4.3).Selectableflowrate
unitsareRPM,µl/min,ml/minandL/min.Selectablevolumeunitsareµl,
mlandL.Selectablepausetimeunitsaresec,min,andhours.Onlyflowratecanbechangedduring