Technical Specifications
Innovation , Quality, Performance
Master Slave
PowerAC120V50-60Hz/ AC230V50-60Hz
Fuse20mm Glass T15A
LampXENON200W
Dimensions330 x205 x100 mm / 13 x8.1x3.94 in
Weight2.24 kg/ 4.93 lbs2.17 kg/ 4.77 lbs
User Guide
Pleaseread theseinstructionscarefullybeforeuse
2A
Introduction
Congratulationson thepurchaseofyournewlighting effect. Weareconfidentyouwillenjoy
manytroublefree hourswiththisunit. Toassist withthecareand useoftheproduct wehave
preparedthisshort guide.
SafetyPrecaution
Avoid directeye exposure.
Disconnectfrommain power before replacing lamp orservicing.
Remember to always replace with thesame lamp.
Topreventfireorshock hazard,donotexpose thisunittorainor
moisture.
Thisproductmustnotbeusedcontinuouslylonger than15 minutes
under maximumspeed and dimmer.
Thefollowingpointsareimportantforsafetyaswellasforthesmoothinstallationand
performanceof theunit.
Unpack carefullyand besurethat no damagehasoccurredduring transportation.
It isveryimportanttoground theyellow/greenconductorinordertomeetsafetyregulations.
Donot connect thedevicetoanydimmerpack.
Theelectricalworkthat isnecessaryforinstallation must bedonebyqualifiedpersonnel.
Besuretolocatetheunitinaplacewithadequateventilation at least 15 cmfromthewalls.
Besurethat no ventilation slotsareblocked.
Becarefulthatnoliquidsorotherobjectscan entertheunit.If thiseverhappens,disconnect
themainpowerimmediately.
Intheeventofseriousoperatingproblems,turnoffthepowerimmediately.Nevertryto
repairtheunityourself.Repairscarriedoutbynon-qualifiedpersonnelcan lead toserious
damageormalfunction.Pleasecontactyourdealerfortechnicalassistance.Alwaysuse
genuinespareparts.
Always remembertounplug theunit fromthemainspowerbeforeanyserviceisdone.
ECDeclaration ofConformity
Wedeclarethatourproducts(lightingequipments)complywiththefollowing
specification andbearsCEmarkinaccordancewiththeprovisionofthe
ElectromagneticCompatibility(EMC)Directive89/336/EEC.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
HarmonizedStandard
EN60598-1: 2000+ALL:2000+A12:2002
Safetyof householdand similarelectricalappliances
Part 1: Generalrequirements
3A
Troubleshooting
If theunit isnot functional –check mainpowersupplyis ‘on’and check fuses.
If theunit isfunctionalbut lampdoesnot light -lampmayrequirereplacing.
If theunitisnotmovingtothemusiccheck thesound-activationadjustment(when
applicable)
Ifaftertrying thesesolutionsyou stillhaveaproblemcontactyourdealerfortechnical
assistance.
Theunitisbuilt-inthermalswitch,thelampwillnotworkingwhentheinternaltemperatureis
above800C, and thelampwill working whentheinternaltemperatureiscooldown.
Caution
Donot obstruct theairvents.
Donot touchunit whilehot.
Nouserserviceablepartsinsidepleaserefertothenearestauthorizedtechnicalassistance
officeforservice.
Power Connections
Theunitissuppliedwithapowerplugappropriatetoitsvoltageand destination.Shouldany
otherconnectionsberequiredtheymust becarriedout withthefollowing configuration.
Earth=Green/Yellowcable
Neutral=Bluecable
Live=Browncable
IntheUSA&Europe,itisrequiredthatallplugsare3-pintypei.e.withEarth/Ground
connection.
IntheUK, it isrequiredthat all mainsplugsarefittedwith13Afuses.
How To Control TheUnit
A.SlaveUnitonly
Thisfixtureisdesignedtooperateasastand-aloneunit, thestrobespeedisadjustable.Itcan
becontrolledbystrobecontrollers,likeBF-01C,BF-04C,BF-04A.,etc.Onecanlinktheslave
unitwiththeMasterUnitforanactivepre-programmed strobeshow(PleaserefertoIBeat
Systembelow.)
B. I BeatSystem
Thissystemisdesignedtooperateundermaster/slavelink.Thereisagreatbuilt-inprograms
inthemasterunitand can betriggeredbymusic.Bylinkingtheunitsinmaster/slave
connection,thefirst(master)unitwillcontroltheotherunitstogiveanautomaticsound
activatedsynchronizedlightshow. Thisfunctionisgoodwhenyouwantaninstantshow.Just
plug inand playforimmediateoperation.
MasterSlave1Slave2Slave3
By Easy Controller
Theeasy remotecontrolisusedonlyinmaster/slavemode.By
connectingtothe1/4”microphonejackofthefirstunit,youwill find
thattheremotecontrolonthefirstunitwillcontrolalltheotherunits
forStand by, Full on/Next/Speedand Audio/Manual/Autofunction.
-- STAND BY : stand byand blackout all theunit.
-- FULLON/ NEXT/ SPEED :
UnderAudiostatus(LEDlightoff),holdontheFULL ONbutton,all
theunitswill strobequickly.
UnderManualstatus(LEDlighton), choosenextpattern, triggered
bymusic, bypress thebutton NEXT.
UnderAutostatus(LEDlightblinking ),pressSPEEDbuttonbriefly
tochoosethepatterns(12patternsvarywithdifferentspeeds-fast,
normal, orslow), thepatternswill run inaloop.
-- AUDIO / MANUAL/ AUTO :
AUDIO status(LEDlight off ): All patternstriggeredbymusic.
MANUALstatus(LEDlighton):Press buttonNexttochoosethenextpatterntriggeredby
music.
AUTOstatus(LEDlightblinking ):PressbuttonSpeedtochoosepatternsvaried with
speed.
4A
How To ChangeTheLamp
Always switchoff themainsupplyand neverhandlethelamporluminairewhenit ishot.
Donottouchthebulbwithbarehands.If thisdoeshappen,clean thelampwithdenatured
alcoholand wipewithalint free clothbeforeinstalling.
Rememberalways replacewiththesametypelamp.
1.Loosethe screwson the
metalbaseat bottom.
2.Taketheplasticbase-
cover
out ofthe casing.
3.Loosethe screwsofthe
lampwireconnecttothe PCB
on the PCBand cutthe binder
offixthe lampwireon the PCB.
4.Pokethelampholderonthe
side ofthelampandtakeoutit
fromfixture.
5.Insertthenewlamptothe
fixture,takethesiliconetube
fromoldlampand installthe
lampwireintothe silicone tube.
6.Connectthe lampwireand
trigger
wiretothe PCBas
before.Note:The lampt
rigger
wireistiny,pleasedonot
damage the wirewhenscrew
in.
7.Pleasereinstallstep 1and
step 2.

Popular Test Equipment manuals by other brands

GW Instek PEL-3000 Series quick start guide

GW Instek

GW Instek PEL-3000 Series quick start guide

Buhler GAS 222.35 Installation and operation instruction

Buhler

Buhler GAS 222.35 Installation and operation instruction

Sperry instruments TD-2608 operating instructions

Sperry instruments

Sperry instruments TD-2608 operating instructions

Mastech MS8922H operating instructions

Mastech

Mastech MS8922H operating instructions

Kohler TT-5230 Installation instructions manual

Kohler

Kohler TT-5230 Installation instructions manual

NoiseKen 03-00074A instruction manual

NoiseKen

NoiseKen 03-00074A instruction manual

ToolKitRC MC8 user manual

ToolKitRC

ToolKitRC MC8 user manual

Fieldpiece SMAN440 Operator's manual

Fieldpiece

Fieldpiece SMAN440 Operator's manual

tibelec M300C instructions

tibelec

tibelec M300C instructions

Svantek SV 111 user manual

Svantek

Svantek SV 111 user manual

Energy Recovery Pressure Exchanger 4S Series Installation, operation & maintenance manual

Energy Recovery

Energy Recovery Pressure Exchanger 4S Series Installation, operation & maintenance manual

RAK RAK10701-P quick start guide

RAK

RAK RAK10701-P quick start guide

Kubota 7780 Brochure & specs

Kubota

Kubota 7780 Brochure & specs

Sealey VS0061.V2 instructions

Sealey

Sealey VS0061.V2 instructions

Fluke 1507 Quick reference guide

Fluke

Fluke 1507 Quick reference guide

Dosy PM-1000 instruction manual

Dosy

Dosy PM-1000 instruction manual

Micromeritics FlowPrep 060 Operator's manual

Micromeritics

Micromeritics FlowPrep 060 Operator's manual

AQ-Tron BAT/47914 manual

AQ-Tron

AQ-Tron BAT/47914 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.