iSolution iBeat User manual

Technical Specifications
Innovation , Quality, Performance
Master Slave
PowerAC120V50-60Hz/ AC230V50-60Hz
Fuse20mm Glass T15A
LampXENON200W
Dimensions330 x205 x100 mm / 13 x8.1x3.94 in
Weight2.24 kg/ 4.93 lbs2.17 kg/ 4.77 lbs
User Guide
Pleaseread theseinstructionscarefullybeforeuse

2A
Introduction
Congratulationson thepurchaseofyournewlighting effect. Weareconfidentyouwillenjoy
manytroublefree hourswiththisunit. Toassist withthecareand useoftheproduct wehave
preparedthisshort guide.
SafetyPrecaution
Avoid directeye exposure.
Disconnectfrommain power before replacing lamp orservicing.
Remember to always replace with thesame lamp.
Topreventfireorshock hazard,donotexpose thisunittorainor
moisture.
Thisproductmustnotbeusedcontinuouslylonger than15 minutes
under maximumspeed and dimmer.
Thefollowingpointsareimportantforsafetyaswellasforthesmoothinstallationand
performanceof theunit.
Unpack carefullyand besurethat no damagehasoccurredduring transportation.
It isveryimportanttoground theyellow/greenconductorinordertomeetsafetyregulations.
Donot connect thedevicetoanydimmerpack.
Theelectricalworkthat isnecessaryforinstallation must bedonebyqualifiedpersonnel.
Besuretolocatetheunitinaplacewithadequateventilation at least 15 cmfromthewalls.
Besurethat no ventilation slotsareblocked.
Becarefulthatnoliquidsorotherobjectscan entertheunit.If thiseverhappens,disconnect
themainpowerimmediately.
Intheeventofseriousoperatingproblems,turnoffthepowerimmediately.Nevertryto
repairtheunityourself.Repairscarriedoutbynon-qualifiedpersonnelcan lead toserious
damageormalfunction.Pleasecontactyourdealerfortechnicalassistance.Alwaysuse
genuinespareparts.
Always remembertounplug theunit fromthemainspowerbeforeanyserviceisdone.
ECDeclaration ofConformity
Wedeclarethatourproducts(lightingequipments)complywiththefollowing
specification andbearsCEmarkinaccordancewiththeprovisionofthe
ElectromagneticCompatibility(EMC)Directive89/336/EEC.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
HarmonizedStandard
EN60598-1: 2000+ALL:2000+A12:2002
Safetyof householdand similarelectricalappliances
Part 1: Generalrequirements

3A
Troubleshooting
If theunit isnot functional –check mainpowersupplyis ‘on’and check fuses.
If theunit isfunctionalbut lampdoesnot light -lampmayrequirereplacing.
If theunitisnotmovingtothemusiccheck thesound-activationadjustment(when
applicable)
Ifaftertrying thesesolutionsyou stillhaveaproblemcontactyourdealerfortechnical
assistance.
Theunitisbuilt-inthermalswitch,thelampwillnotworkingwhentheinternaltemperatureis
above800C, and thelampwill working whentheinternaltemperatureiscooldown.
Caution
Donot obstruct theairvents.
Donot touchunit whilehot.
Nouserserviceablepartsinsidepleaserefertothenearestauthorizedtechnicalassistance
officeforservice.
Power Connections
Theunitissuppliedwithapowerplugappropriatetoitsvoltageand destination.Shouldany
otherconnectionsberequiredtheymust becarriedout withthefollowing configuration.
Earth=Green/Yellowcable
Neutral=Bluecable
Live=Browncable
IntheUSA&Europe,itisrequiredthatallplugsare3-pintypei.e.withEarth/Ground
connection.
IntheUK, it isrequiredthat all mainsplugsarefittedwith13Afuses.
How To Control TheUnit
A.SlaveUnitonly
Thisfixtureisdesignedtooperateasastand-aloneunit, thestrobespeedisadjustable.Itcan
becontrolledbystrobecontrollers,likeBF-01C,BF-04C,BF-04A.,etc.Onecanlinktheslave
unitwiththeMasterUnitforanactivepre-programmed strobeshow(PleaserefertoIBeat
Systembelow.)
B. I BeatSystem
Thissystemisdesignedtooperateundermaster/slavelink.Thereisagreatbuilt-inprograms
inthemasterunitand can betriggeredbymusic.Bylinkingtheunitsinmaster/slave
connection,thefirst(master)unitwillcontroltheotherunitstogiveanautomaticsound
activatedsynchronizedlightshow. Thisfunctionisgoodwhenyouwantaninstantshow.Just
plug inand playforimmediateoperation.
MasterSlave1Slave2Slave3
By Easy Controller
Theeasy remotecontrolisusedonlyinmaster/slavemode.By
connectingtothe1/4”microphonejackofthefirstunit,youwill find
thattheremotecontrolonthefirstunitwillcontrolalltheotherunits
forStand by, Full on/Next/Speedand Audio/Manual/Autofunction.
-- STAND BY : stand byand blackout all theunit.
-- FULLON/ NEXT/ SPEED :
UnderAudiostatus(LEDlightoff),holdontheFULL ONbutton,all
theunitswill strobequickly.
UnderManualstatus(LEDlighton), choosenextpattern, triggered
bymusic, bypress thebutton NEXT.
UnderAutostatus(LEDlightblinking ),pressSPEEDbuttonbriefly
tochoosethepatterns(12patternsvarywithdifferentspeeds-fast,
normal, orslow), thepatternswill run inaloop.
-- AUDIO / MANUAL/ AUTO :
AUDIO status(LEDlight off ): All patternstriggeredbymusic.
MANUALstatus(LEDlighton):Press buttonNexttochoosethenextpatterntriggeredby
music.
AUTOstatus(LEDlightblinking ):PressbuttonSpeedtochoosepatternsvaried with
speed.

4A
How To ChangeTheLamp
Always switchoff themainsupplyand neverhandlethelamporluminairewhenit ishot.
Donottouchthebulbwithbarehands.If thisdoeshappen,clean thelampwithdenatured
alcoholand wipewithalint free clothbeforeinstalling.
Rememberalways replacewiththesametypelamp.
1.Loosethe screwson the
metalbaseat bottom.
2.Taketheplasticbase-
cover
out ofthe casing.
3.Loosethe screwsofthe
lampwireconnecttothe PCB
on the PCBand cutthe binder
offixthe lampwireon the PCB.
4.Pokethelampholderonthe
side ofthelampandtakeoutit
fromfixture.
5.Insertthenewlamptothe
fixture,takethesiliconetube
fromoldlampand installthe
lampwireintothe silicone tube.
6.Connectthe lampwireand
trigger
wiretothe PCBas
before.Note:The lampt
rigger
wireistiny,pleasedonot
damage the wirewhenscrew
in.
7.Pleasereinstallstep 1and
step 2.
Popular Test Equipment manuals by other brands

GW Instek
GW Instek PEL-3000 Series quick start guide

Buhler
Buhler GAS 222.35 Installation and operation instruction

Sperry instruments
Sperry instruments TD-2608 operating instructions

Mastech
Mastech MS8922H operating instructions

Kohler
Kohler TT-5230 Installation instructions manual

NoiseKen
NoiseKen 03-00074A instruction manual