manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. iSolution
  6. •
  7. Test Equipment
  8. •
  9. iSolution iBeat User manual

iSolution iBeat User manual

Popular Test Equipment manuals by other brands

Ambit P.F. Series instruction manual

Ambit

Ambit P.F. Series instruction manual

Megger BMM500 Series user guide

Megger

Megger BMM500 Series user guide

RJG Lynx Sensor Tester operating instructions

RJG

RJG Lynx Sensor Tester operating instructions

Mark-10 TT02 Series user guide

Mark-10

Mark-10 TT02 Series user guide

Martel 3001 Operator's manual

Martel

Martel 3001 Operator's manual

ElproSys DiagProg4 instruction manual

ElproSys

ElproSys DiagProg4 instruction manual

Redtech TRAILERteck T05 user manual

Redtech

Redtech TRAILERteck T05 user manual

Venmar AVS Constructo 1.0 HRV user guide

Venmar

Venmar AVS Constructo 1.0 HRV user guide

Test Instrument Solutions SafetyPAT operating manual

Test Instrument Solutions

Test Instrument Solutions SafetyPAT operating manual

Hanna Instruments HI 38078 instruction manual

Hanna Instruments

Hanna Instruments HI 38078 instruction manual

Kistler 5495C Series instruction manual

Kistler

Kistler 5495C Series instruction manual

Waygate Technologies DM5E Basic quick start guide

Waygate Technologies

Waygate Technologies DM5E Basic quick start guide

StoneL DeviceNet CK464002A manual

StoneL

StoneL DeviceNet CK464002A manual

Seica RAPID 220 Site preparation guide

Seica

Seica RAPID 220 Site preparation guide

Kingfisher KI7400 Series Training manual

Kingfisher

Kingfisher KI7400 Series Training manual

Kurth Electronic CCTS-03 operating manual

Kurth Electronic

Kurth Electronic CCTS-03 operating manual

SMART KANAAD SBT XTREME 3G Series user manual

SMART

SMART KANAAD SBT XTREME 3G Series user manual

Agilent Technologies BERT Serial Getting started

Agilent Technologies

Agilent Technologies BERT Serial Getting started

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Technical Specifications
Innovation , Quality, Performance
Master Slave
PowerAC120V50-60Hz/ AC230V50-60Hz
Fuse20mm Glass T15A
LampXENON200W
Dimensions330 x205 x100 mm / 13 x8.1x3.94 in
Weight2.24 kg/ 4.93 lbs2.17 kg/ 4.77 lbs
User Guide
Pleaseread theseinstructionscarefullybeforeuse
2A
Introduction
Congratulationson thepurchaseofyournewlighting effect. Weareconfidentyouwillenjoy
manytroublefree hourswiththisunit. Toassist withthecareand useoftheproduct wehave
preparedthisshort guide.
SafetyPrecaution
Avoid directeye exposure.
Disconnectfrommain power before replacing lamp orservicing.
Remember to always replace with thesame lamp.
Topreventfireorshock hazard,donotexpose thisunittorainor
moisture.
Thisproductmustnotbeusedcontinuouslylonger than15 minutes
under maximumspeed and dimmer.
Thefollowingpointsareimportantforsafetyaswellasforthesmoothinstallationand
performanceof theunit.
Unpack carefullyand besurethat no damagehasoccurredduring transportation.
It isveryimportanttoground theyellow/greenconductorinordertomeetsafetyregulations.
Donot connect thedevicetoanydimmerpack.
Theelectricalworkthat isnecessaryforinstallation must bedonebyqualifiedpersonnel.
Besuretolocatetheunitinaplacewithadequateventilation at least 15 cmfromthewalls.
Besurethat no ventilation slotsareblocked.
Becarefulthatnoliquidsorotherobjectscan entertheunit.If thiseverhappens,disconnect
themainpowerimmediately.
Intheeventofseriousoperatingproblems,turnoffthepowerimmediately.Nevertryto
repairtheunityourself.Repairscarriedoutbynon-qualifiedpersonnelcan lead toserious
damageormalfunction.Pleasecontactyourdealerfortechnicalassistance.Alwaysuse
genuinespareparts.
Always remembertounplug theunit fromthemainspowerbeforeanyserviceisdone.
ECDeclaration ofConformity
Wedeclarethatourproducts(lightingequipments)complywiththefollowing
specification andbearsCEmarkinaccordancewiththeprovisionofthe
ElectromagneticCompatibility(EMC)Directive89/336/EEC.
EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002;
EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996,
EN61000-4-11: 1994.
&
HarmonizedStandard
EN60598-1: 2000+ALL:2000+A12:2002
Safetyof householdand similarelectricalappliances
Part 1: Generalrequirements
3A
Troubleshooting
If theunit isnot functional –check mainpowersupplyis ‘on’and check fuses.
If theunit isfunctionalbut lampdoesnot light -lampmayrequirereplacing.
If theunitisnotmovingtothemusiccheck thesound-activationadjustment(when
applicable)
Ifaftertrying thesesolutionsyou stillhaveaproblemcontactyourdealerfortechnical
assistance.
Theunitisbuilt-inthermalswitch,thelampwillnotworkingwhentheinternaltemperatureis
above800C, and thelampwill working whentheinternaltemperatureiscooldown.
Caution
Donot obstruct theairvents.
Donot touchunit whilehot.
Nouserserviceablepartsinsidepleaserefertothenearestauthorizedtechnicalassistance
officeforservice.
Power Connections
Theunitissuppliedwithapowerplugappropriatetoitsvoltageand destination.Shouldany
otherconnectionsberequiredtheymust becarriedout withthefollowing configuration.
Earth=Green/Yellowcable
Neutral=Bluecable
Live=Browncable
IntheUSA&Europe,itisrequiredthatallplugsare3-pintypei.e.withEarth/Ground
connection.
IntheUK, it isrequiredthat all mainsplugsarefittedwith13Afuses.
How To Control TheUnit
A.SlaveUnitonly
Thisfixtureisdesignedtooperateasastand-aloneunit, thestrobespeedisadjustable.Itcan
becontrolledbystrobecontrollers,likeBF-01C,BF-04C,BF-04A.,etc.Onecanlinktheslave
unitwiththeMasterUnitforanactivepre-programmed strobeshow(PleaserefertoIBeat
Systembelow.)
B. I BeatSystem
Thissystemisdesignedtooperateundermaster/slavelink.Thereisagreatbuilt-inprograms
inthemasterunitand can betriggeredbymusic.Bylinkingtheunitsinmaster/slave
connection,thefirst(master)unitwillcontroltheotherunitstogiveanautomaticsound
activatedsynchronizedlightshow. Thisfunctionisgoodwhenyouwantaninstantshow.Just
plug inand playforimmediateoperation.
MasterSlave1Slave2Slave3
By Easy Controller
Theeasy remotecontrolisusedonlyinmaster/slavemode.By
connectingtothe1/4”microphonejackofthefirstunit,youwill find
thattheremotecontrolonthefirstunitwillcontrolalltheotherunits
forStand by, Full on/Next/Speedand Audio/Manual/Autofunction.
-- STAND BY : stand byand blackout all theunit.
-- FULLON/ NEXT/ SPEED :
UnderAudiostatus(LEDlightoff),holdontheFULL ONbutton,all
theunitswill strobequickly.
UnderManualstatus(LEDlighton), choosenextpattern, triggered
bymusic, bypress thebutton NEXT.
UnderAutostatus(LEDlightblinking ),pressSPEEDbuttonbriefly
tochoosethepatterns(12patternsvarywithdifferentspeeds-fast,
normal, orslow), thepatternswill run inaloop.
-- AUDIO / MANUAL/ AUTO :
AUDIO status(LEDlight off ): All patternstriggeredbymusic.
MANUALstatus(LEDlighton):Press buttonNexttochoosethenextpatterntriggeredby
music.
AUTOstatus(LEDlightblinking ):PressbuttonSpeedtochoosepatternsvaried with
speed.
4A
How To ChangeTheLamp
Always switchoff themainsupplyand neverhandlethelamporluminairewhenit ishot.
Donottouchthebulbwithbarehands.If thisdoeshappen,clean thelampwithdenatured
alcoholand wipewithalint free clothbeforeinstalling.
Rememberalways replacewiththesametypelamp.
1.Loosethe screwson the
metalbaseat bottom.
2.Taketheplasticbase-
cover
out ofthe casing.
3.Loosethe screwsofthe
lampwireconnecttothe PCB
on the PCBand cutthe binder
offixthe lampwireon the PCB.
4.Pokethelampholderonthe
side ofthelampandtakeoutit
fromfixture.
5.Insertthenewlamptothe
fixture,takethesiliconetube
fromoldlampand installthe
lampwireintothe silicone tube.
6.Connectthe lampwireand
trigger
wiretothe PCBas
before.Note:The lampt
rigger
wireistiny,pleasedonot
damage the wirewhenscrew
in.
7.Pleasereinstallstep 1and
step 2.