isweek AquaTuff FW2000 User manual

AquaTuff™
FW2000MK
Digital Thermocouple
Thermometer
Warranty
®
AquaTuff™
FW2000
5 YEAR
WARRANTY
Any instrument which proves
to be defective in material or
workmanship within five years
of original purchase will be
repaired or replaced without
charge upon receipt of the
unit prepaid with proof of
purchase. This Limited
Warranty does not cover
damage in shipment or failure
caused by tampering, obvious
carelessness, or abuse, and
is the purchaser’s sole
remedy.
MMaannuuffaaccttuurreeddiinntthheeUUSSAAbbyyCCOOOOPPEERR--AATTKKIINNSSCCOORRPPOORRAATTIIOONN
AAnnIISSOO99000011RReeggiisstteerreeddFFaacciilliittyy
27-958489E
Press to activate / deactivate the unit.
Note: Unit will automatically shut off after
1-1/2 minutes of inactivity.
Press to select Fahrenheit scale.
During Calibration, press to increase the
temperature displayed.
Press to select Celsius scale.
During Calibration, press to decrease the
temperature displayed.
Atkins Key. Used as a “Hold” button
during calibration only.
1. Press the ON/OFF Key to turn on the unit.
(No other button will activate the FW2000 / FW2000MK.)
2. Select the temperature scale you wish to have the unit
display.
-- Press the FKey to display Fahrenheit readings or
-- Press the CKey to display Celsius readings.
3.Insert probe into item to be tested.
Special notes:
• If the measured temperature is stable (doesn’t change by
more than 3°F (2°C)) for 1-1/2 minutes, the unit will shut off
automatically.
• If the battery needs to be replaced, three blinking decimal points
(. . . ) appear on the LCD display. This means that 8 hours of
battery life remain. As battery voltage becomes less, “b.A.t.”
will appear along with 3 blinking decimal points.
• If the unit gets a reading that is outside of its range
(-100° to 999°F )(-73° to 537°C), it will display either “HI” or “LO”,
as appropriate.
• The unit has a “continuous on” feature. To activate, the unit
must be on. Hold down the Atkins Key and press and release
the ON/OFF Key. To deactivate, press the ON/OFF Key and
the unit will turn off.
To calibrate the unit, the temperature of the test solution you are
using must be 32°F (0°C) ± 5°F (±2°C)
or
must be greater than
60°F (16°C). For best results, use an ice bath which consists
almost entirely of crushed ice, with only a little water. Proceed as
follows:
1. Turn unit on.
2. Place the probe into the test solution.
3. Hold down both the F and C keys until “CAL” is displayed.
This takes approximately 3 seconds. You are now in
calibration mode.
OPERATING
INSTRUCTIONS
4. Release both keys. “CAL” will be replaced by “Hold” on
the display.
5. Press and hold down the Atkins Key. “Hold” will be replaced
by three decimal points ( . . . ) with the current temperature
reading.
6. While holding the Atkins Key down, press the up or down
arrow keys (F or C) as appropriate. For example, if you are
using the ice bath method, and your reading is 35°F, press and
release the down arrow key as many times as needed until
“32F” displays on the LCD.
7. When you are done making adjustments, or if no
calibration is necessary, simply keep the Atkins Key
pressed until “End” displays on the LCD (approximately 7
seconds) and the unit returns to NORMAL mode. Release
the Atkins Key.
Special notes:
• Failure to keep the Atkins Key pressed down at all times during
calibration will take you out of the mode and read “Abrt”. To
correct this simply restart the calibration process from
Calibration step 1.
• If the unit cannot be recalibrated by using the ice bath
method you can reset the unit to factory settings. To do so,
while in the CAL mode, still holding the Atkins Key, press both
the F and C keys for 3 seconds to select the factory defaults.
“FAC” will be displayed on the LCD for 2 seconds.
HOLD MODE
If “Hold” is displayed on the LCD when the unit is turned on, it
means an error has occurred. To correct this error, press the Atkins
Key. This will reset the unit to its previous calibration.
THE KEYS
NORMAL OPERATION
CALIBRATION
CALIBRATION - Continued
ON
OFF
F
C
SPÉCIFICATIONS / FONCTIONS
FW2000 Temperature Range:
FW2000MK Temperature Range:
Probe Temperature Range:
Ambient Operating Range:
Accuracy from -35° to 350°F (-37° to 177°C)
in Ambient 60° to 80°F (16° to 27°C):
Accuracy from All Other Ranges:
Temperature Display Resolution:
Battery:
Battery Life:
Low Battery:
Automatic Shut Off:
LCD:
-100° to 500°F (-73° to 260°C)
-100° to 999°F (-73° to 537°C)
-100° to 500°F (-73° to 260°C)
0° to 115°F (-18° to 46°C)
±1F° (±0.5C°)
±2F° (±1C°)
1°F or 1°C
9 volt alkaline NEDA 1604
Minimum of 500 hours ON time
LCD displays 3 blinking decimal
points when 8 hours of battery
life remain
After 1-1/2 minutes of non-use
Liquid crystal display, with
0.5” (1.27 cm) high
digits; viewing area
1.5” x 0.7” (3.81 x 1.77 cm)
45

This manual suits for next models

1

Popular Thermometer manuals by other brands

ADC Adtemp V 418 Use, care & maintenance

ADC

ADC Adtemp V 418 Use, care & maintenance

Fisher Bioblock Scientific EcoScan Temp JKT quick start guide

Fisher Bioblock Scientific

Fisher Bioblock Scientific EcoScan Temp JKT quick start guide

Terdens 2109 Manual User

Terdens

Terdens 2109 Manual User

Fluke 51 II Series Specifications

Fluke

Fluke 51 II Series Specifications

Microlife MT 19F1 manual

Microlife

Microlife MT 19F1 manual

optris CTratio Operator's manual

optris

optris CTratio Operator's manual

Omega HH63K user guide

Omega

Omega HH63K user guide

Flamingo SH210 user manual

Flamingo

Flamingo SH210 user manual

Thermor BIOS 120SC quick start guide

Thermor

Thermor BIOS 120SC quick start guide

Microlife IFR 100 manual

Microlife

Microlife IFR 100 manual

PCE Health and Fitness PCE-313A-ICA manual

PCE Health and Fitness

PCE Health and Fitness PCE-313A-ICA manual

SEIZ Lasertemp operating manual

SEIZ

SEIZ Lasertemp operating manual

Beurer medical FT 58 Instructions for use

Beurer medical

Beurer medical FT 58 Instructions for use

Oregon Scientific AW133 user manual

Oregon Scientific

Oregon Scientific AW133 user manual

Elma Instruments Elma 315 user manual

Elma Instruments

Elma Instruments Elma 315 user manual

RayTek AUTO PRO manual

RayTek

RayTek AUTO PRO manual

iHealth PT2L user manual

iHealth

iHealth PT2L user manual

HYGIPLAS GH628 quick start guide

HYGIPLAS

HYGIPLAS GH628 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.