Itm INFORCE COLOR LE/MP User manual

Offensively, the INFORCE Color Law Enforcement / Military Police Strobing Illumination System supports long distance visibility with a 200-lumen
high powered white light while having the advantages of medium and low intensities. Defensively, it lets you be seen with strobing red and blue
output. It also features a disorienting red/blue/white strobe with random pattern and frequency cycles. Using a proprietary venting system, the
INFORCE Color LE/MP is built to stay cool for maximum performance.
LIGHT OUTPUT, PRIMARY LED:
High Setting: 200 lumens
Medium Setting: 60 lumens
Low Setting: 8 lumens
RUN TIMES:
High Setting: 2h 45min
Medium Setting: 6h+
Low Setting: 40h+
Red/Blue Strobe: 12h
Red/Blue/White Strobe: 5h 45min
Bezel Diameter: 1.25 in. / 3.175 cm.
Length: 6.175 in. / 15.68 cm.
Weight: 4.5 oz. / 127.5 g.
(2) Lithium 123A Batteries Included
Primary White Light
2-Color ID/Marker Beacon
3-Color Disorienting Strobe
INFORCE®
INFORCE COLOR LE/MP
STROBING ILLUMINATION SYSTEM
©2011 EMISSIVE ENERGY Corp. An ISO9001:2008 Certified Company.
135 Circuit Drive, North Kingstown, RI 02852; Tel: 401-294-2030; Fax: 401-294-2050; www.inforce-mil.com
INFORCE and EMISSIVE ENERGY are registered trademarks of Emissive Energy Corp. The distinctive shapes, styles, packaging configurations and overall appearances of
INFORCE lighting systems are trademarks of Emissive Energy Corp. Designed and manufactured under one or more of the following U.S. and International patents: U.S.:
6,966,677; 7,121,680; 7,153,004; 7,226,183; 7,517,108; 7,652,303; 7,784,963; D526,730; D565,220; D579,201; D596,329; D619,283. European: 467295-0001; 467295-0002.
Other U.S. and International patents are pending.
Designed and assembled in the U.S.A. of domestic and foreign components. INFORCE products qualify as “American Made” under the Buy America Act.
PM1049/111807
CAUTION: Do not use counterfeit or inferior-quality batteries, as they do
not meet safety and performance standards and have been the cause
of personal and property damage. To ensure safety and performance,
the purchase of established brands, such as Duracell®, Energizer®or
Panasonic®is recommended.
ITEM NUMBER BODY COLOR LED
INF-B-PBR Black Primary: White; Secondary: Red, Blue
FIBER COMPOSITE BODY is ultralight and durable.
SINGLE-HAND OPERATION
Simple, reliable, intuitive tailcap switch operates programs and modes.
BELT CLIP W/BUILT-IN LANYARD HOLE accepts 550 cord.
SCALLOPED HEAD is designed to let the light “spill out” to indicate
that the light is on while in an upright position.
PATENTED HEAT RELEASING VENTS maximize LED performance
and keep the light cool to hold.
Features and Benefits:
HIGH EFFICIENCY EMITTERS provide longer run times and are
virtually immune to failure.
PRECISION OPTICS provide focused hot spot and balanced peripheral light.
HIGH-IMPACT GLASS WINDOW
WATERPROOF to 66 feet.
MIL-STD-810F Certified.
Limited Lifetime Warranty
www. .com information@itm.com1.800.561.8187

PM1041/111807
INFORCE®
INFORCE COLOR LE/MP STROBING ILLUMINATION SYSTEM
USER MANUAL AND WARRANTY
Turn tailcap switch and
TIGHTEN SECURELY.
These two ribs must align
to make proper contact.
GETTING STARTED
Your INFORCE light is equipped with two (2) high-efficiency 123A Lithium batteries.
To insert the batteries, turn the multi-function tailcap counterclockwise to remove it from
the flashlight body. Insert the batteries into the open handle, positive (+) end first.
Re-thread the multi-function tailcap clockwise onto the flashlight handle. When the
tailcap can be turned no further, it is ready for operation. Rotate to the desired function
position for activation.
If the flashlight malfunctions, the tailcap switch hasn’t been sufficiently tightened;
ribs must align to make proper contact. Remove the cap and repeat the process.
CAUTION: Lithium batteries can explode or cause burns if recharged, shorted, disassembled
or exposed to water, high temperatures or fire. Please follow manufacturer’s guidelines for
safe storage, use and disposal. If the light has been submerged, dry the exterior of the light
prior to replacing the batteries. Fresh and salt water will damage internal electronics and
batteries. Do not use counterfeit or inferior-quality batteries, as they do not meet safety
standards and have been the cause of personal and property damage. To ensure safety
and performance, the purchase of established brands, such as Duracell®, Energizer®or
Panasonic®is recommended.
Notes:
• Whenreplacingbatteries,nevermixbatterytypeoroldandnewbatteries.
• Batteriescanleakandmaycausedamagetotheinsideofthelight.Removethe
batteries if the flashlight will be stored for more than 2 weeks.
• Flashlightheadsarenon-removable;anyattempttoremovetheheadwilldamage
the light and void the warranty.
• Thelightoutputoftheflashlightwilldimovertimeasyourbatteriesstarttodrain.
At some point, batteries that have been depleted substantially will not have
enough energy to sustain a full high power output. At that time, there will be
little to no distinction when attempting to cycle between high and medium modes.
However, there will still be enough energy in the batteries to produce useful light for
a period of time. This is not an indication that the batteries have to be changed.
MAINTENANCE/CLEANING INSTRUCTIONS
Your INFORCE flashlight has been designed to provide maximum performance with
minimum maintenance. Should the flashlight become dirty from dust, sand or caked-on
mud, rinse fully assembled light with water and dry with a soft cloth.
IMPORTANT
Red Gasket Seal Contacts
Threads
NEVER USE LUBRICANT, GREASE, OIL OR OIL-
IMPREGNATED CLOTH ON ANY SEALS, THREADS OR
CONTACTS WITHIN THE LIGHT.
Lubricants will adversely affect the compression seals
and performance of the switching mechanism of the
multi-function tailcap switch. Should the seals get lubricant
or grease on them, simply clean the threaded surfaces
and gasket seals with alcohol.
CONSTANT WHITE: Turn the tailcap switch two clicks to the left of the center position
and rapidly press the tailcap button to select High, Medium or Low level light.
MOMENTARY WHITE: The tailcap position for momentary white light is one click to the
left of center. The light intensity level will be determined by the light level selected in the
constant white mode. If the tailcap switch is rotated from the momentary white position
back to the constant white position, the light will turn on at the same light level that was
originally selected.
INFORCE COLOR LE/MP OPERATION
Engineered for single-hand operation and ease of use, the INFORCE COLOR LE/MP flashlight
as been designed to deliver precise lighting performance. It includes three programmed levels
CONSTANT WHITE MOMENTARY WHITE CENTER
OFF/LOCKOUT
RED/BLUE/WHITE
DISORIENTING STROBE
RED/BLUE MARKER
STROBE
RED/BLUE/WHITE DISORIENTING STROBE: Turn the tailcap switch one click to the right
of the center position.
RED/BLUE MARKER STROBE: Turn the tailcap switch two clicks to the right of the center
position.
of lighting intensity in the white constant and momentary settings plus red/blue marker
strobe, red/blue/white disorienting strobe and lockout modes.
NOTE: High, medium or low light settings selected in CONSTANT WHITE position will be programmed/saved if rotated to the momentary position. When the light is turned
off by clicking the activation button or by rotating the tailcap switch to the center position, the light will reset to the default/high intensity.
PRODUCT WARRANTY
Emissive Energy Corp. (EEC) warrants our products and accessories to be free of defect in workmanship and materials for the lifetime of the original owner. We will repair or replace the product, at our
discretion, if it is determined by us to be defective. In countries or jurisdictions in which specific restrictions exist on lifetime warranties, EEC provides a 10-year limited warranty. Damage to the
productfrommisuse,abuse,neglect,useofotherthanINFORCEbrandaccessories,disassembly,defectivebatteriesoralteringtheproductfromitsoriginalstatevoidsthewarranty.Batterypower
depletion and battery expiration is not covered. This warranty is in addition to and does not affect your statutory rights with respect to faulty goods.
THISCONSTITUTESEEC’SENTIREWARRANTY;WEMAKENOOTHERWARRANTIES,WHETHEREXPRESSORIMPLIED,WITHRESPECTTOTHEPRODUCTS,INCLUDINGANDWITHOUTLIMITATIONTO
WARRANTIESOFMERCHANTABILITYANDFITNESSFORAPARTICULARPURPOSE.EXCEPTFORTHEEXPRESSWARRANTYTOREPAIRORREPLACETHEPRODUCTASSETFORTHABOVE,EECISNOT
RESPONSIBLEFORANYDIRECT,SPECIAL,INCIDENTAL,CONSEQUENTIAL,EXEMPLARYORINDIRECTCOSTSORDAMAGES,REGARDLESSOFTHEFORMOFACTION,WHETHERINCONTRACT,TORT
(INCLUDINGNEGLIGENCE),STRICTLIABILITYOROTHERWISE,EVENIFEECHASBEENADVISEDOFTHEPOSSIBILITYTHEREOF,NORISEECLIABLEFORANYSUCHCOSTSORDAMAGESCAUSEDBY
MISUSE,NEGLIGENCE,MALFUNCTION,ALTERATIONORMODIFICATIONOFANYINFORCEPRODUCTS.BECAUSESOMESTATESDONOTALLOWTHEEXCLUSIONORLIMITATIONOFLIABILITYFOR
CONSEQUENTIALORINCIDENTALDAMAGES,INSUCHSTATESEEC’SLIABILITYISLIMITEDTOTHEFULLEXTENTPERMITTEDBYLAW.
©2011EmissiveEnergyCorp.135CircuitDrive,NorthKingstown,RI02852USA;Tel:401-294-2030;Fax:401-294-2050;www.inforce-mil.com
INFORCEandEMISSIVEENERGYareregisteredtrademarksofEMISSIVEENERGYCORP.Thedistinctiveshapes,styles,packagingconfigurationsandoverallappearanceofallINFORCEflashlights
andlightingproductsaretrademarksofEMISSIVEENERGYCORP.DesignedandmanufacturedunderoneormoreofthefollowingU.S.andInternationalpatents:U.S.:6,966,677;7,121,680;
7,153,004;7,226,183;7,517,108;7,652,303;7,784,963;D526,730;D565,220;D579,201;D596,329;D619,283.European:467295-0001;467295-0002.Other U.S. and International patents
are pending.
DesignedandassembledintheU.S.A.ofdomesticandforeigncomponents.Thisproductqualifiesas“AmericanMade”undertheBuyAmericaAct.
www. .com information@itm.com1.800.561.8187
Table of contents
Other Itm Test Equipment manuals
Popular Test Equipment manuals by other brands

Agilent Technologies
Agilent Technologies InfiniiVision 2000 X-Series Programmer's guide

Kenwood
Kenwood CS-5230 Service manual

Gossen MetraWatt
Gossen MetraWatt METRAHIT IM E-DRIVE FUSO operating instructions

Tektronix
Tektronix 321 A instruction manual

Triplett
Triplett WiFi Hound user manual

Shimpo
Shimpo TRC Series Operation manual