ITS Telecom EKSELANS CCA 370001 User manual

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
USER MANUAL CCA
TABLE OF CONTENTS
1. Overview................................................................................................................................................................................................................................... 3
2. Accessories............................................................................................................................................................................................................................ 3
3. Connections and indicators ..................................................................................................................................................................................... 4
4. Input and output voltage ........................................................................................................................................................................................... 5
4.1. Controller voltage feeding............................................................................................................................................................................... 5
4.2. Door opener voltage feeding .......................................................................................................................................................................6
5. Installation............................................................................................................................................................................................................................... 7
6. Programming and Users Management ........................................................................................................................................................9
6.1. Numbering user cards ......................................................................................................................................................................................10
6.2. Programming via keyboard (remote control) ...............................................................................................................................10
6.2.1 Signals when programming the CCA.........................................................................................................................................10
6.2.2. Programming mode (via remote control)...............................................................................................................................11
6.2.3. User management (via remote control) ..................................................................................................................................11
6.2.4. Relay configuration (via remote control) ...............................................................................................................................13
6.2.5Control signals (via remote control) .............................................................................................................................................13
6.2.6. Cloning of controllers.............................................................................................................................................................................14
6.3. Programming via master cards.................................................................................................................................................................15
6.3.1. Registering master cards.....................................................................................................................................................................15
6.3.2. Management of user cards using master cards .............................................................................................................15
6.4. Restore to factory default values............................................................................................................................................................16
7. Technical specifications............................................................................................................................................................................................17

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
3
USER MANUAL CCA
1. Overview
The access controller, CCA, allows the opening of all types of door openers once an authorized
RFID card has been read. The reading is performed by an external reader connected to the
controller (Ref. LCA). The controller is compatible with several input voltages. It allows to control the
voltage pass that feeds the current lock or use the power supply of the controller to power the lock.
Thanks to all these compatibilities the controller can be coupled to existing systems or installed in
new scenarios.
The programming of user cards can be done through the use of other cards (called master) or
through a remote control. It is important to note that, through remote control, other functions can be
performed such as setting the opening time, deleting and registering cards selectively, activating or
deactivating the sound or LED indicators, ... Master cards provide simplicity when registering user
cards.
There is no distinction between cards except their programming; For example, a master card could
be programmed as a user card. As explained below, it is important to identify each user card with
an identifying number.Permite alimentar varios tipos de cerradura (AC/DC) con la propia tensión
que alimenta a la controladora.
•It allows to feed several types of lock (AC / DC) with the own voltage that feeds the controller
•It allows to control the voltage that feeds the lock from an external source, either AC or DC
•Allows the connection of a button (push button) for instant door opening
•Users registered in a controller can be cloned in other controllers
•Supports up to 1000 users
•Compatible with Wiegand readers
•Allows management by remote control
2. Accessories
•1x Remote control (keyboard)
•1x Master card to add users
•1x Master card to remove users
•1x Configuration jumper
•1x Protection diode
•1x Screwdriver
•2x Anchors and screws
•1x Installation Manual

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
4
USER MANUAL CCA
3. Connections and indicators
Signal
Terminal
strip
Type
Description
BUZZER
Left
Output
Tone indicator to the card reader
LED
Output
Led indicator of the card reader
D0
Entrada
Data[0] reception from the card reader
D1
Entrada
Data[1] reception from the card reader
GND
Entrada /
Output
Ground (Connection to the card reader)
GND
Entrada /
Output
Ground (DC Voltage feeding)
AC / DC +
Entrada
Common connector for AC or DC power (positive)
AC
Entrada
Connector for AC voltage feeding
OPEN
Right
Entrada
Connect to the external push button (Optional)
NO
Output
Relay output (Normally open)
COM
Output
In "Dry Contact" configuration (Position A): Common
Port
In "DC Out" configuration (Position B): Ground
Connect to external push button (optional)
NC
Output
Relay output (Normally closed)
V OUT
Output
Voltage for feeding the card reader
IR
Input
IR sensor for remote control
Output
Status LED indicator
Operation
LED
Sound
Stand-by
Red
-
Programming mode start
Blinking red
One bip
Programming command start
Orange
Two bips
Error
-
Three bips
End programming mode
Red
One bip
Opening
Green
One bip

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
5
USER MANUAL CCA
4. Input and output voltage
The controller supports a wide range of supply voltage, both in AC or DC. The self-lock power supply
can be used to feed the controller. See technical specifications on section 7.
Important note:
Make sure that the supply voltages of the lock and the controller are
compatible. Especially in the case of using the supply voltage of the
controller to feed the lock (Jumper in position A - Dry Contact-). See
section 4.2.
4.1. Controller voltage feeding
The controller can be fed both in AC or DC voltage
In case of powering the controller with alternating
current, connect the source to the terminals
indicated as "AC and AC".
In case of powering the controller with direct
current, connect the source to the terminals
indicated as "GND and DC +". Respect the polarity.
Check the maximum rating voltage in the technical specification.

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
6
USER MANUAL CCA
4.2. Door opener voltage feeding
The controller may act on the door-opener in two
modes depending on the position of some
jumpers. These jumpers are inside the device, in
the lower right corner. Open carefully.
There are two positions:
Position A (Dry Contact) contact jumper 3-1:
It allows the passage of current between an external power supply and
the lock. It acts as a switch. Make sure that the lock supports the power
supply voltage of the external power supply. This is the factory
configuration.
Position B (Direct step) jumper in contact 3-4 and 1-2:
It feeds the lock with the same voltage that feeds the controller itself. It
will only work with DC DC.
A-Position (Dry contact)
B-Position (Input pass)
Terminals
COM-NC
COM-NO
COM-NC
COM-NO
Stand-by
Short circuit
Open circuit
Same voltage
as in the input
0V
Opening
Open circuit
Short circuit
0V
Same voltage
as in the input

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
7
USER MANUAL CCA
To modify the way the lock is fed, open the box and set up the jumpers.
Store the excess jumper if you move from position B to position A.
Attention:
Install the supplied diode directly in the door
opener in the case that it supplies the lock with
direct voltage -DC.
Do not use the diode in case of powering the
system in AC. Respect the polarity of the diode
as indicated:
5. Installation
Below are several typical installations with their connection and configuration:
Configuration in dry contact (the lock opens as the controller opens or closes; The controller acts as a
switch).

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
8
USER MANUAL CCA
Configuration in dry contact (the lock opens as the controller opens or closes; The controller acts as a
switch).
Configuration in dry contact (the lock opens as the controller opens or closes; The controller acts as a
switch).

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
9
USER MANUAL CCA
Configuration in “Input Pass” (the same voltage that feeds the controller, will feed the lock). The lock
must be of the same power as the CCA.
6. Programming and Users Management
The programming of the cards is stored in the memory of the device so the system is robust in the event
of power supply drops. In the absence of power supply the controller will not be able to activate the
door opening, as it will not read the cards.
The system supports up to 1000 user cards. Each of them is registered in the system as they are
registered, with an identifier (0, 1, 2, ... 999).
Important note:
It is not possible to know which identifier corresponds to each user card, so it
is recommended that a record is kept. Keeping the registry will allow deleting
a user card (without physically having it). If this is not the case, it will be
necessary to delete and re-register all the cards.
Card management can be done by keyboard (remote control) or by other types of cards (called a
master).
Two cards are supplied to be configured as master. One will be used to discharge and the other to
unsubscribe the user cards. There can only be one set of master cards: Master-High and Master-Low.
If you delete out a second set of master cards, the previous one is voided.

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
10
USER MANUAL CCA
6.1. Numbering user cards
To keep a correct control of the identifier associated with each card, it is important to know that:
•The first card discharged is the 000.
•The second will be 001, the third will be 002 and so on until the last (thousand) that will be the
999.
•If the third card is deleted, a hole (bubble) is created between 001 and 003.
•When registering a new card with the master cards, this bubble will be filled (the new card will
be 002).
•With the remote control, you can force a card to have a specific identifier, leaving bubbles if
desired.
•There cannot be two user cards with the same identifier.
It is recommended to register the identifier by relating it to the serial number of the card and to the user
of the card. It is not recommended to write down the identifier on the card itself. Should it be lost, the
identifier to be removed from the controller will not be known.
Identifier
Serial Number of the user card
Person / Department / Apartment
0
0093119565
Mr. Juan Pérez
1
0093119566
Ms. Marta López
…
…
…
999
0093117684
Ms. Teresa Monte
6.2. Programming via keyboard (remote control)
The supplied remote control allows the programming of the controller. To do this, aim it to the IR sensor
and press the indicated commands.
6.2.1 Signals when programming the CCA
When you turn on the CCA the LED will change from green to red and beep.
•Press on the controller: red LED will flash, after 5 seconds it returns to normal state and will
stay in fixed red.
•Press 1 2 3 4 5 6: LED goes green, whistles once and will flash red. After 35 seconds it will
return to normal and stay in fixed red.
•Press Incorrect code: It will emit three beeps and the LED will remain red, it will not enter
programming mode .

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
11
USER MANUAL CCA
6.2.2. Programming mode (via remote control)
In this mode it is possible to carry out the programming using the remote control by entering different
commands.
•To enter this mode, press:
Enter in the programming mode
< Master code > (Default master code
123456)
Exit the programming mode
•To change the master code
Step 1
Enter in the programming
mode
< Master code >
Step 2
Insert the new master code.
It's a 6-digit code
0< New master code >
< New master code >
Step 3
Exit the programming mode
If you change the master code, remember it. Otherwise it will be necessary to make a factory default
reset.
It must have 6 digits.
6.2.3. User management (via remote control)
Each user card is registered with an identifier that matches its position within the system. The controller
can assign auto-incremented identifiers. You can also assign a specific identifier.
•Subscribing:
To add user cards at a position given by the system:
Step 1
Enter in the programming mode
< Master code >
Step 2
Pass the card through the reader and
press Repeat this step if several cards
need to be registered
1< Sweep card >
Step 3
Exit the programming mode
Remember that in the case there are empty positions not assigned to a card (Bubbles), this
process will assign to the card registered the first available position/identifier. A bubble will
appear when a specific card (Not the last one) has been removed.

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
12
USER MANUAL CCA
To add user cards in a particular position:
Step 1
Enter in the programming mode
< Master code >
Step 2
Insert the desired identifier and sweep the
card.
1 < Desired identifier > <
Sweep card > Where <Desired
identifier> is a number from 1
to 999. Do not insert 00x. Insert
x directly
Step 3
Exit the programming mode
•Unsubscribing:
To delete a user card by reading it with the card reader (Not lost card):
Step 1
Enter in the programming mode
< Master code >
Step 2
Sweep the card to be unsubscribed. This
position will be empty .
2 < Sweep card >
Step 3
Exit the programming mode
Note that a bubble can be been created. There can be an empty identifier position not linked
with a user card.
To delete a user card from a specific position (The card is lost):
Step 1
Enter in the programming mode
< Master code >
Step 2
Insert the identifier position to be deleted.
This position will be deleted
2 < Identifier Where
<Identifier> is a number from 1
to 999. Do not insert 00x. Insert
x directy.
Step 3
Salir del modo programación
Note that a bubble can be been created. There can be an empty identifier position not linked
with a user card.
To delete all user cards in the system
Step 1
Enter in the programming mode
< Master code >
Paso 2
2 < Master code >
Step 3
Exit the programming mode

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
13
USER MANUAL CCA
6.2.4. Relay configuration (via remote control)
The opening time can be adjusted as wished in a range from 1 to 99 seconds. Its default value is 5
seconds:
Step 1
Enter in the programming mode
< Master code >
Step 2
Insert two digits that indicate the number of
seconds that open the relay.
3 (1~99)#
Example: Insert <310#> for 10
seconds.
Step 3
Exit the programming mode
6.2.5Control signals (via remote control)
It is possible to enable / disable basic signalling indicators. By default, those are enabled.
Step 1
Enter in the programming mode
< Master code >
Step 2A
Indication sound
70 OFF
71 ON
Step 2B
Led indication
74 OFF
75 ON
Step 3
Exit the programming mode

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
14
USER MANUAL CCA
6.2.6. Cloning of controllers
ATTENTION CLONING CAN ONLY BE DONE WITH 12 VDC NOT IN AC. CLONE SO THAT THE CCA IN
WHICH THE CONFIGURATION IS TO BE DUMPED (THE RECEIVER) IS NOT VISIBLE FROM THE
CONTROLLER, SAVE IT IN A DRAWER OR COVER IT IF NECESSARY.
The controller may be cloned to another CCA controller. The copied data are the configurations of the
transmitter controller and the registered user cards.
Make the following connections:
Apply the following steps to the unit to clone (transmitter):
Step 1
Enter in the programming mode
< Master code >
Paso 2
Start the transfer
96
Paso 3
Wait until the transmission ends
The green LED blinks
Step 4
Exit the programming mode
Note that:
•Both units must have the same master code.
•A cloning process with 1000 registered users may last up to 3 minutes.
•Check connections. Avoid short circuits.

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
15
USER MANUAL CCA
6.3. Programming via master cards
By using the master cards it is possible to subscribe / unsubscribe user cards, without need to use the
remote control.
This method does not allow to delete a user card that has been lost, even knowing its identifier.
6.3.1. Registering master cards
The master cards need also to be paired to the system. Should a second pair of master cards is
registered, the first will be unregistered. The master cards, cannot be programmed via keyboard.
Step 1
Power off the controller
Step 2
Make a short circuit between GND and OPEN.
Otherwise, should a push button be connected
(for opening purposes), keep it pressed
Step 3
Power on the system again
Two sounds will be heard and
the LED will change its colour
Step 4
Present the two cards on the card reader. The
first will be coded as “MASTER ADD” (For
subscribing). The second, will be “MASTER
DELTE” (For unsubscribing).
After each card presentation, a
single sound will be heard.
After presenting the second
card, the system will enter in
stand-by mode.
If any card is presented within
10 seconds, the system will
enter in stand-by mode.
Step 5
Remove the bridge
Master cards cannot be programmed by keyboard.
6.3.2. Management of user cards using master cards
To add user cards, perform this process on the reader:
Step 1
Sweep MASTER ADD card
Step 2
Sweep the user card
More user cards may be swept (A
sound will be heard)
Step 3
Sweep MASTER ADD card

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
16
USER MANUAL CCA
To unsubscribe cards into the system, perform this process:
Step 1
Sweep MASTER DELETE card
Step 2
Sweep the user card
More user cards may be swept (A
sound will be heard)
Step 3
Sweep MASTER DELETE card
6.4. Restore to factory default values
The following process restores the original default factory values. Registered user cards, are NOT lost.
Registered
master cards, yes. Other values are set back to factory default:
Step 1
Power off the controller
Step 2
Make a short circuit between GND and OPEN.
Otherwise, should a push button be connected (for opening
purposes), keep it pressed.
Step 3
Power on the system again
Two sounds will be heard
and the LED will change its
colour
Step 4
Keep the short circuit for at least 10 seconds.
A sound will be Heard and
will enter in stand-by mode.
(Red LED)

ITS Partner O.B.S S.L · Av. Cerdanyola 79-81 Local C
08172 Sant Cugat del Vallés · Barcelona (Spain)
Phone: +34935839543 · info@ek.plus · www.ek.plus
17
USER MANUAL CCA
7. Technical specifications
REFERENCE
CCA
Code
037001
Maximum users
<1000
Transmisson protocol card reader –
controller
Wiegand
Working voltage / (Nominal)
AC
V (rms)
12~30 / (24)
DC
Vdc
9~24 / (12)
Consumption (Stand-by / Maximum*)
AC
mA (rms)
115 / 170
DC
mA
60 / 80
Output voltage (For LCA)
Vdc
12
Maximum switching current
A
1
Maximum distance IR- Keyboard **
m
<10
Working temperatura
ºC
-40 ~ 60
Working humidity
% Hum
0 ~ 90
Dimensions
mm
90 x 63 x 22
Including reader / excluding door-opener.
Depending on Ilumination / battery.
Table of contents
Other ITS Telecom IP Access Controllers manuals