ADDITIONAL FUNCTIONS
AUTO SHUTOFF: When the bucket is full, removed, or not locked correctly into place, or when the humidity in the
room becomes 5% lower than the set (or preset) humidity level, the device will automatically stop dehumidifying.
The fan will continue to run for three minutes until the Bucket Alert sounds, and then shut itself o entirely.
BUCKET FULL WARNING: When the Full indicator LED is illuminated, this means the bucket needs to be removed
and emptied. If the bucket is not full, this LED indicates that the drainage bucket has either been removed or is not
placed correctly.
SETTING MEMORY: If for any reason power to the unit is lost or shut o, all of your control panel settings will be
stored in the dehumidifier’s memory and will resume normal function when power is restored.
CLEAN FILTER WARNING: The Filter indicator LED automatically lights up after the device has run for a total of 250
hours as a reminder for you to check and clean the filter. If you have already replaced or cleaned the filter, press the
Filter button to reset the light.
AUTO DEFROST: When frost builds up on the evaporator coils, the compressor will cycle o and the fan will continue
to run until the frost disappears.
USING YOUR DEHUMIDIFIER
For further detail on the functions of the buttons and lights on the control panel, please refer to the Control Panel
section of this user guide.
1. Press the power button to turn the unit on.
2. Use the + or – keys to adjust the humidity level from 35%–85%, by increments of 5%.
3. Press the button labeled Fan to toggle the fan speed between normal and high.
4. If you would like to set a timer for how long the dehumidifier should run, follow these instructions. If not, skip
to step 5.
a. Press the Timer button while the device is switched on. The On indicator light will turn on.
b. Use the + and – keys to set the duration of the timer. (If the duration is less than 10 hours, the + and – keys
will adjust in increments of 0.5 hours. If the duration is more than 10 hours, they will adjust the duration in
increments of one (1) hour. Maximum duration is 24 hours.)
c. Once the time is set, wait five (5) seconds for the timer to automatically confirm. DO NOT press the Timer
button a second time, as this will turn the timer o.
d. To cancel an existing timer, press the Timer button. The O indicator will turn on, indicating no timer is
currently set.
5. If you would like the dehumidifier to operate in one of the preset modes (Regular, Continuous, or Comfort), press
the MODE button until the indicator LED next to your preferred mode is illuminated. Please note that while using
the dehumidifier in any preset mode, you cannot change the humidity levels, but you can change the fan speed.
6. Once you’ve established your preferred settings, you can press and hold the + and – keys for three (3) seconds
until the unit beeps once to lock the buttons on the control panel. To unlock the control panel and make any
changes, simply press and hold the + and – keys for another three (3) seconds.
DRAINAGE OPTIONS
Option 1: Manual Drainage
1. Hold the handles on both sides of the water bucket and gently pull it straight toward you.
Make sure to do this slowly and carefully because water may spill onto the floor or the unit itself.
2. Empty the water bucket by grasping the handle on top with one hand and using the other
to hold the bottom of the bucket as you pour out the water.
3. Once the bucket is emptied, replace it as normal into the dehumidifier.
NOTE: Do not remove the bucket while the dehumidifier is running or when it has just
stopped. This will cause water to spill onto the floor and could create an electric shock risk.
Do not connect a drainage hose if you intend to use the bucket to drain the water manually.
6