IXL 10324 User manual

User Guide
IXL Eco Ventflo
Model: 10324 (200mm) - Extraction Rate: 340m3/h
Model: 10326 (250mm) - Extraction Rate: 490m3/h
Electrical Rating: 230~240 Va.c. 50Hz.
User Guide
IXL Eco Ventflo
Model: 10324 (200mm) - Extraction Rate: 340m3/h
Model: 10326 (250mm) - Extraction Rate: 490m3/h
Electrical Rating: 230~240 V. 50 Hz.

2
Welcome
Thank you for buying this IXL Eco Ventflo Fan. Even if you have used a Tastic before, there are very
good reasons to read this user guide before using this one:
• You and your family, property and home will be safe from harm.
• You will learn how this appliance may differ from others.
• By using the Ventflo Fan fully and properly, you will get maximum life and value from it.
• Our warranty depends on you using the Ventflo Fan according to this user guide.
It will only take you a few minutes, so please read on!
Contents Page
Safety...........................................................................................3-4
Clearances...................................................................................... 5
Flat Roof Installations..................................................................... 6
Electrical Requirements................................................................. 6
Wiring Diagrams............................................................................. 7
Ventilation Requirements............................................................... 8
Installation......................................................................................9
Use.................................................................................................10
Cleaning........................................................................................10
Record Your Model........................................................................11
Warranty..........................................................................12-13
Notes............................................................................................. 14
Template for Cut Out.................................................................... 15
Safety
IXL Eco Ventflo
Read through these instructions fully before commencing installation.
Locate the IXL Eco Ventflo in accordance with the requirements of the current Australian/ New Zealand
Wiring Rules AS/NZS 3000 relating to damp situations, or according to applicable Wiring Rules for
installations outside of Australia and New Zealand. This appliance has an IP24 rating which means it is
suitable for Zone 1 installations and can be mounted directly above a bath or shower recess.
This unit is fitted with a cord and plug, however, any interconnecting wiring and switches used must
be fitted by a licensed electrician.
Switches and other controls must not be located where they can be touched by a person in the bath
or shower.
WARNING:
• Do not use this appliance for functions other than those described in this user guide.
• After removing the appliance from its packaging, ensure that it is complete and undamaged.
If in doubt contact a qualified electrician or IXL Home. Do not leave packaging within the reach
of children or infirm persons.
• This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning the use of the appliance by a person responsible for
their safety.
• Young children should be supervised to ensure they do not play with the appliance.
• Do not operate the appliance in the presence of inflammable vapours
(alcohol, insecticides, petrol, etc.)
• Do not sit or place objects on or in the appliance.
• The supply cord cannot be replaced. If the cord is damaged the appliance should be scrapped.
• Do not operate this appliance without the plastic surround in position.
• This appliance must be mounted with the lowest point at least 2.1 metres from the floor.
• Ensure that the fan is switched off from the supply mains before removing the grille.
• Precautions must be taken to avoid the back-flow of gases into the rooms from the open flue
of gas or other fuel-burning appliances.
Do not allow insulation material to rest against the sides or
top of the Ventflo unit when installed.

4
Safety cont.
IXL Eco Ventflo
CAUTION:
• Do not make modifications of any kind to this appliance.
• Do not expose this appliance to the weather (rain, sun, etc.)
• Do not immerse the appliance or any parts of it in water or other liquids. Refer to
the relevant instructions to clean the appliance (page 10) If the appliance does not
function correctly or develops a fault, contact IXL Home immediately.
• Should the appliance be dropped or suffer a heavy blow, have it checked by an
authorised service agent for IXL products
• The electrical system to which the appliance is connected must conform to
applicable standards.
• The electrical power supply/socket to which the appliance is to be connected must
be able to provide the maximum electrical power required by the appliance. If it
can’t do this, contact a qualified electrician to make the necessary modifications.
• Switch off the appliance at the installation’s main switch: a) if the appliance does
not function correctly; b) before cleaning the outside of the appliance; c) if the
appliance is not going to be used for any length of time.
• The room must have an adequate source of replacement air for this appliance
to function effectively. Moreover, if there is any non-sealed combustion based
appliance such as a water heater, gas stove, etc. in the same room, air replacement
must be sufficient for all appliances to work effectively together.
• Keep the appliance’s inlet grille free from dust to ensure optimum air flow
Clearances
All appliances must be mounted so that the lowest
point is at least 2.1m above the floor. The IXL Eco
Ventflo is designed to fit a ceiling cavity with a
minimum height of 215 mm (10324) & 260 mm
(10326) when installed in a well ventilated roof
cavity. Where ventilation is restricted, these heights
should be increased by a minimum of 25 mm. This
will allow for the back draught shutters to open fully
when the unit is in operation.
Additionally, a minimum of 40 mm clearance is
required between the sides of the fan and any
adjoining parts of the roof structure, such as walls,
joists or insulation batts.
Figure 2 measurement A:
Model 10324 (Ventflo 200)
215 mm min. where there is good ventilation to the
sides of the unit.
240 mm min. where ventilation to the sides of the
unit is restricted.
Model 10326 (Ventflo 250)
260 mm min. where there is good ventilation to the
sides of the unit.
285 mm min. where ventilation to the sides of the
unit is restricted.
Figure 2 measurement B:
40 mm min. clearance on all sides to allow clips to
fully rotate outwards.
IXL Eco Ventflo
Clearances
All appliances must be mounted so that the lowest
point is at least 2.1m above the floor. The IXL Eco
Ventflo is designed to fit a ceiling cavity with a
minimum height of 215 mm (10324) & 260 mm
(10326) when installed in a well ventilated roof
cavity. Where ventilation is restricted, these heights
should be increased by a minimum of 25 mm. This
will allow for the back draught shutters to open fully
when the unit is in operation.
Additionally, a minimum of 40 mm clearance is
required between the sides of the fan and any
adjoining parts of the roof structure, such as walls,
joists or insulation batts.
Figure 3 measurement A:
Model 10324 (Ventflo 200)
215 mm min. where there is good ventilation to the
sides of the unit.
240 mm min. where ventilation to the sides of the
unit is restricted.
Model 10326 (Ventflo 250)
260 mm min. where there is good ventilation to the
sides of the unit.
285 mm min. where ventilation to the sides of the
unit is restricted.
Figure 3 measurement B:
40 mm min. clearance on all sides to allow clips to
fully rotate outwards.
DRN
CHK
APP
REL
3rd ANGLE PROJECTION
THIS DRAWING AND DESIGN
REMAINS THE PROPERTY OF
SAMPFORD IXL PTY. LTD. THE
INFORMATION IS CONFIDENTIAL
AND IS NOT TO BE REPRODUCED OR
DISCLOSED TO ANY PARTY OUTSIDE
YOUR ORGANISATION WITHOUT
PRIOR WRITTEN AUTHORISATION
FROM SAMPFORD IXL PTY. LTD.
Pty. Ltd.
MATL
NAME
SCALE
SHEET
DRG
ISSUE
SAMPFORD IXL - SHEET SIZE A1
2 OF 4
10324 instructions
1:2
A
UNLESS OTHERWISE STATED
DIMENSIONS IN MILLIMETRES
TOLERANCES
LINEAR
HOLE GROUPS
BLANK DIM,S
HOLES
ANGULAR
0.5
0.1
0.2
0.2
0.2
DRN
-
-
-
-
-
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12
-
g
MASS
VENTFLO 200 - AXIAL FAN
VOLUME
mm3
Fig. 1: Adequate open space in the roof
cavity is required
A
B
FLAPS
DRN
CHK
APP
REL
3rdANGLE PROJECTION
THISDRAWING AND DESIGN
REMAINSTHE PROPERTY OF
SAMPFORDIXL PTY. LTD. THE
INFORMATIONIS CONFIDENTIAL
ANDIS NOT TO BE REPRODUCED OR
DISCLOSEDTO ANY PARTY OUTSIDE
YOURORGANISATION WITHOUT
PRIORWRITTEN AUTHORISATION
FROMSAMPFORD IXL PTY. LTD.
Pty. Ltd.
MATL
NAME
SCALE
SHEET
DRG
ISSUE
SAMPFORDIXL - SHEET SIZE A1
1OF 4
10324 instructions
1:1
A
UNLESSOTHERWISE STATED
DIMENSIONSIN MILLIMETRES
TOLERANCES
LINEAR
HOLEGROUPS
BLANKDIM,S
HOLES
ANGULAR
0.5
0.1
0.2
0.2
0.2
DRN
-
-
-
-
-
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12
-
g
MASS
VENTFLO 200 - AXIAL FAN
VOLUME mm3
Fig. 2: Minimum clearances for installation
IXL Eco Ventflo
Electrical Requirements
Flat Roof Installations
See the wiring diagram (Fig. 5) for supply requirements and maximum loadings for each model.
Fans may be connected to a lighting power circuit if loading permits. Wiring of the wall switch (not
provided) and socket outlet in roof cavity must be carried out by a registered electrician. The wall
switch should be located in accordance the Wiring Rules AS/NZS 3000. It must not be installed where
it can be reached by a person in the bath or shower.
When installing into a flat roof with insufficient
clearance, or where ceiling cavity ventilation is
restricted, an external venting duct must be installed.
Use Fig. 4 as a guide to minimum external outlet
requirements.
IMPORTANT: Do not attach the duct to the body of
the fan. Allow for 10-20 mm minimum gap between
the fan and the end of the duct. The duct should
have a diameter of at least 235mm (10324) &
290mm (10326).
Fig. 3: Minimum external outlet requirements
IXL Eco Ventflo
6

Flat Roof Installations
IXL Eco Ventflo
When installing into a flat roof with insufficient
clearance, or where ceiling cavity ventilation is
restricted, an external venting duct must be installed.
Use Fig. 3 as a guide to minimum external outlet
requirements.
IMPORTANT: Do not attach the duct to the
body of the fan. Allow for 10-20 mm minimum gap
between the fan and the end of the duct. The duct
should have a diameter of at least 235mm (10324) &
290mm (10326).
Electrical Requirements
See the wiring diagram (Fig. 4) for supply requirements and maximum loadings for each model.
Fans may be connected to a lighting power circuit if loading permits. Wiring of the wall switch (not
provided) and socket outlet in roof cavity must be carried out by a registered electrician. The wall
switch should be located in accordance the Wiring Rules AS/NZS 3000. It must not be installed where
it can be reached by a person in the bath or shower.
Clearances
All appliances must be mounted so that the lowest
point is at least 2.1m above the floor. The IXL Eco
Ventflo is designed to fit a ceiling cavity with a
minimum height of 215 mm (10324) & 260 mm
(10326) when installed in a well ventilated roof
cavity. Where ventilation is restricted, these heights
should be increased by a minimum of 25 mm. This
will allow for the back draught shutters to open fully
when the unit is in operation.
Additionally, a minimum of 40 mm clearance is
required between the sides of the fan and any
adjoining parts of the roof structure, such as walls,
joists or insulation batts.
Figure 3 measurement A:
Model 10324 (Ventflo 200)
215 mm min. where there is good ventilation to the
sides of the unit.
240 mm min. where ventilation to the sides of the
unit is restricted.
Model 10326 (Ventflo 250)
260 mm min. where there is good ventilation to the
sides of the unit.
285 mm min. where ventilation to the sides of the
unit is restricted.
Figure 3 measurement B:
40 mm min. clearance on all sides to allow clips to
fully rotate outwards.
DRN
CHK
APP
REL
3rd ANGLE PROJECTION
THIS DRAWING AND DESIGN
REMAINS THE PROPERTY OF
SAMPFORD IXL PTY. LTD. THE
INFORMATION IS CONFIDENTIAL
AND IS NOT TO BE REPRODUCED OR
DISCLOSED TO ANY PARTY OUTSIDE
YOUR ORGANISATION WITHOUT
PRIOR WRITTEN AUTHORISATION
FROM SAMPFORD IXL PTY. LTD.
Pty. Ltd.
MATL
NAME
SCALE
SHEET
DRG
ISSUE
SAMPFORD IXL - SHEET SIZE A1
2 OF 4
10324 instructions
1:2
A
UNLESS OTHERWISE STATED
DIMENSIONS IN MILLIMETRES
TOLERANCES
LINEAR
HOLE GROUPS
BLANK DIM,S
HOLES
ANGULAR
0.5
0.1
0.2
0.2
0.2
DRN
-
-
-
-
-
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12
-
g
MASS
VENTFLO 200 - AXIAL FAN
VOLUME
mm3
Fig. 1: Adequate open space in the roof
cavity is required
A
B
FLAPS
DRN
CHK
APP
REL
3rdANGLE PROJECTION
THISDRAWING AND DESIGN
REMAINSTHE PROPERTY OF
SAMPFORDIXL PTY. LTD. THE
INFORMATIONIS CONFIDENTIAL
ANDIS NOT TO BE REPRODUCED OR
DISCLOSEDTO ANY PARTY OUTSIDE
YOURORGANISATION WITHOUT
PRIORWRITTEN AUTHORISATION
FROMSAMPFORD IXL PTY. LTD.
Pty. Ltd.
MATL
NAME
SCALE
SHEET
DRG
ISSUE
SAMPFORDIXL - SHEET SIZE A1
1OF 4
10324 instructions
1:1
A
UNLESSOTHERWISE STATED
DIMENSIONSIN MILLIMETRES
TOLERANCES
LINEAR
HOLEGROUPS
BLANKDIM,S
HOLES
ANGULAR
0.5
0.1
0.2
0.2
0.2
DRN
-
-
-
-
-
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12
-
g
MASS
VENTFLO 200 - AXIAL FAN
VOLUME mm3
Fig. 2: Minimum clearances for installation
IXL Eco Ventflo
Electrical Requirements
Flat Roof Installations
See the wiring diagram (Fig. 5) for supply requirements and maximum loadings for each model.
Fans may be connected to a lighting power circuit if loading permits. Wiring of the wall switch (not
provided) and socket outlet in roof cavity must be carried out by a registered electrician. The wall
switch should be located in accordance the Wiring Rules AS/NZS 3000. It must not be installed where
it can be reached by a person in the bath or shower.
When installing into a flat roof with insufficient
clearance, or where ceiling cavity ventilation is
restricted, an external venting duct must be installed.
Use Fig. 4 as a guide to minimum external outlet
requirements.
IMPORTANT: Do not attach the duct to the body of
the fan. Allow for 10-20 mm minimum gap between
the fan and the end of the duct. The duct should
have a diameter of at least 235mm (10324) &
290mm (10326).
Fig.
3:
Minimum external outlet requirements
IXL Eco Ventflo
6
Wiring Diagrams
IXL Eco Ventflo
Wiring Diagrams
Fig. 4: Wiring diagram.
IXL Eco Ventflo
Installation
Important considerations before installing
• Joists, beams and rafters shall not be cut or notched to install the appliance.
• This unit has an IP24 rating which means it is suitable for Zone 1 installations and can be installed
directly above a shower or bath.
• For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being
extracted must be able to enter the room. In general this air would be drawn under the door or
through a slightly open window. If the room is airtight the fan will function poorly.
• This product is designed for installation in flat ceiling only. Do not mount it on a sloping ceiling
or vertical wall.
Fig. 6: Mounting clips open
Fig. 5: Mounting clips closed
IXL Eco Ventflo
1. Locating the unit – Before commencing any
cutting, check in the ceiling space that there are
no obstructions such as ceiling joists and that
there is sufficient clearance for the housing.
Check that the electrical wiring can be routed from
the wall switches to the mounting location.
2. Prepare the ceiling – Using the template provided
on page 15, mark the ceiling with a pencil outline
and cut out the required hole (10324 needs 244
mm dia. & 10326 needs 294 mm dia. hole).
3. Remove the grille.
4. Plug the fan into the power point.
5. Ensure that the mounting clips are in the closed
position, then insert fan into ceiling cut out.
6. Using a screwdriver (or a battery driver with a low
torque setting) partially tighten the screws.
This will move the mounting clips into the open
position and hold the unit to the ceiling.
7. Rotate the unit so that the grille direction
lines on the body are aligned with the walls.
These lines show the orientation of the fascia
grille when installed.
8. Tighten the screws. Do not over tighten as this
can damage plasterboard.
9. Fit grille onto unit. Once fitted the grille can be
adjusted to better align with the walls.
8
10324: 0.13A 50Hz, 10326: 0.25A 50Hz
6

Installation
IXL Eco Ventflo
Important considerations before installing
• Joists, beams and rafters shall not be cut or notched to install the appliance.
• This unit has an IP24 rating which means it is suitable for Zone 1 installations and can be installed
directly above a shower or bath.
• For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being
extracted must be able to enter the room. In general this air would be drawn under the door or
through a slightly open window. If the room is airtight the fan will function poorly.
• This product is designed or installation in flat ceiling only. Do not mount it on a sloping ceiling
or vertical wall.
1. Locating the unit – Before commencing any
cutting, check in the ceiling space that there are
no obstructions such as ceiling joists and that
there is sufficient clearance for the housing.
Check that the electrical wiring can be routed from
the wall switches to the mounting location.
2. Prepare the ceiling – Using the template provided
on page 15, mark the ceiling with a pencil outline
and cut out the required hole (10324 needs
244 mm dia. & 10326 needs 294 mm dia. hole).
3. Remove the grille.
4. Plug the fan into the power point.
5. Ensure that the mounting clips are in the closed
position, then insert fan into ceiling cut out.
6. Using a screwdriver (or a battery driver with a low
torque setting) partially tighten the screws.
This will move the mounting clips into the open
position and hold the unit to the ceiling.
7. Rotate the unit so that the grille direction
lines on the body are aligned with the walls.
These lines show the orientation of the fascia
grille when installed.
8. Tighten the screws. Do not over tighten as this can
damage plasterboard.
9. Fit grille onto unit. Once fitted the grille can be
adjusted to better align with the walls.
Wiring Diagrams
Fig. 4: Wiring diagram.
IXL Eco Ventflo
Installation
Important considerations before installing
• Joists, beams and rafters shall not be cut or notched to install the appliance.
• This unit has an IP24 rating which means it is suitable for Zone 1 installations and can be installed
directly above a shower or bath.
• For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being
extracted must be able to enter the room. In general this air would be drawn under the door or
through a slightly open window. If the room is airtight the fan will function poorly.
• This product is designed for installation in flat ceiling only. Do not mount it on a sloping ceiling
or vertical wall.
Fig. 6: Mounting clips open
Fig. 5: Mounting clips closed
IXL Eco Ventflo
1. Locating the unit – Before commencing any
cutting, check in the ceiling space that there are
no obstructions such as ceiling joists and that
there is sufficient clearance for the housing.
Check that the electrical wiring can be routed from
the wall switches to the mounting location.
2. Prepare the ceiling – Using the template provided
on page 15, mark the ceiling with a pencil outline
and cut out the required hole (10324 needs 244
mm dia. & 10326 needs 294 mm dia. hole).
3. Remove the grille.
4. Plug the fan into the power point.
5. Ensure that the mounting clips are in the closed
position, then insert fan into ceiling cut out.
6. Using a screwdriver (or a battery driver with a low
torque setting) partially tighten the screws.
This will move the mounting clips into the open
position and hold the unit to the ceiling.
7. Rotate the unit so that the grille direction
lines on the body are aligned with the walls.
These lines show the orientation of the fascia
grille when installed.
8. Tighten the screws. Do not over tighten as this
can damage plasterboard.
9. Fit grille onto unit. Once fitted the grille can be
adjusted to better align with the walls.
8
10324: 0.13A 50Hz, 10326: 0.25A 50Hz
Ventilation Requirement
IXL Eco Ventflo
For maximum efficiency and fan performance there
are a few key points to keep in mind when installing
your IXL Eco Ventflo exhaust fan.
Sufficient air inlet into room
Steam will only be removed if there is sufficient flow
of air through the room. Ensure generous inlets exist
through windows, vents or under the door. Air flow
path from inlet to fan should ideally pass over the
steam sources. (See Fig 5.)
Adequate ventilation in roof cavity
It is essential that there is adequate space within
the roof cavity so that exhaust air from the fan can
dissipate. Where space is restricted, use Fig. 2 as
a guide to minimum requirements for adequate
ventilation.
The roof cavity itself should be well ventilated to
outside so that moist air can be removed. Local
building codes may require flueing to outside through
roof as per Fig. 3 (page 6) for flat roof installation.
Where ventilation space is restricted
This product is not recommended for installation
between floors of multi-storey dwellings, or where
space within the roof cavity is severely restricted and
a flue as per Fig. 3 cannot be fitted. IXL has other
Ventilation products available that are particularly
suited to installations between floors or where space
is restricted. Contact your nearest IXL Service Centre
on the numbers located on the back of this booklet.
For further details and advice on ventilation products
and tips, visit the IXL Ventilation Selection Guide on
our website: www.ixlappliances.com.au
Ventilation RequirementsSafety cont.
For maximum efficiency and fan performance there
are a few key points to keep in mind when installing
your IXL Eco Ventflo exhaust fan.
Sufficient air inlet into room
Steam will only be removed if there is sufficient flow
of air through the room. Ensure generous inlets exist
through windows, vents or under the door. Air flow
path from inlet to fan should ideally pass over the
steam sources. (See Fig 1.)
Adequate ventilation in roof cavity
It is essential that there is adequate space within
the roof cavity so that exhaust air from the fan can
dissipate. Where space is restricted, use Fig. 3
as a guide to minimum requirements for adequate
ventilation.
The roof cavity itself should be well ventilated to
outside so that moist air can be removed. Local
building codes may require flueing to outside through
roof as per Fig. 4 (page 7) for flat roof installation.
Where ventilation space is restricted
This product is not recommended for installation
between floors of multi-storey dwellings, or where
space within the roof cavity is severely restricted and
a flue as per Fig. 4 cannot be fitted. IXL has other
Ventilation products available that are particularly
suited to installations between floors or where space
is restricted. Contact your nearest IXL Service Centre
on the numbers located on the back of this booklet.
For further details and advice on ventilation products
and tips, visit the IXL Ventilation Selection Guide on
our website: www.ixlappliances.com.au
4
• If the appliance does not function correctly or develops a fault, contact Sampford IXL immediately.
• Should the appliance be dropped or suffer a heavy blow, have it checked by an authorised service
agent for IXL products
• The electrical system to which the appliance is connected must conform to applicable standards.
• The electrical power supply/socket to which the appliance is to be connected must be able to
provide the maximum electrical power required by the appliance. If it can’t do this, contact a
qualified electrician to make the necessary modifications.
• Switch off the appliance at the installation’s main switch: a) if the appliance does not function
correctly; b) before cleaning the outside of the appliance; c) if the appliance is not going to be used
for any length of time.
• The room must have an adequate source of replacement air for this appliance to function
effectively. Moreover, if there is any non-sealed combustion based appliance such as a water
heater, gas stove, etc. in the same room, air replacement must be sufficient for all appliances to
work effectively together.
• Keep the appliance’s inlet grille free from dust to ensure optimum air flow
IXL Eco VentfloIXL Eco Ventflo
Fig. 4: Ideal placement of Ventflo.
Sufficient air inlets into room are required.
Shown installed between shower and bath
Shown installed above shower
8
Fig. 5: Ideal placement of Ventflo. Sufficient
air inlets into room are required.
Fig. 6: Mounting clips closed
Wiring Diagrams
Fig. 4: Wiring diagram.
IXL Eco Ventflo
Installation
Important considerations before installing
• Joists, beams and rafters shall not be cut or notched to install the appliance.
• This unit has an IP24 rating which means it is suitable for Zone 1 installations and can be installed
directly above a shower or bath.
• For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being
extracted must be able to enter the room. In general this air would be drawn under the door or
through a slightly open window. If the room is airtight the fan will function poorly.
• This product is designed for installation in flat ceiling only. Do not mount it on a sloping ceiling
or vertical wall.
Fig. 6: Mounting clips open
Fig. 5: Mounting clips closed
IXL Eco Ventflo
1. Locating the unit – Before commencing any
cutting, check in the ceiling space that there are
no obstructions such as ceiling joists and that
there is sufficient clearance for the housing.
Check that the electrical wiring can be routed from
the wall switches to the mounting location.
2. Prepare the ceiling – Using the template provided
on page 15, mark the ceiling with a pencil outline
and cut out the required hole (10324 needs 244
mm dia. & 10326 needs 294 mm dia. hole).
3. Remove the grille.
4. Plug the fan into the power point.
5. Ensure that the mounting clips are in the closed
position, then insert fan into ceiling cut out.
6. Using a screwdriver (or a battery driver with a low
torque setting) partially tighten the screws.
This will move the mounting clips into the open
position and hold the unit to the ceiling.
7. Rotate the unit so that the grille direction
lines on the body are aligned with the walls.
These lines show the orientation of the fascia
grille when installed.
8. Tighten the screws. Do not over tighten as this
can damage plasterboard.
9. Fit grille onto unit. Once fitted the grille can be
adjusted to better align with the walls.
8
10324: 0.13A 50Hz, 10326: 0.25A 50Hz
Fig. 7: Mounting clips open

10
Use
1. Turn the power switch on/off to make sure the unit runs
2. Running the fan can exhaust steam and odours quickly and efficiently.
Note: Shut off power urgently when any abnormalities occur in operation. Then call a licensed
electrician or IXL service person for inspection and necessary service work.
Do not insert fingers or thin bars into the grille when the unit is operating. This could cause harm to
yourself and the appliance.
The unit must not be installed in a place that suffers from severe water leakage.
Cleaning
1. Pull out the power plug before cleaning or maintenance.
2. Remove grille and wipe it with care using a damp soft cloth with a mild detergent if necessary.
Ensure the motor or other electrical parts can’t touch the water.
3. The grille can be cleaned in a dishwasher on low heat setting ~45°C and only wash on the
top shelf.
4. Replace the grille after it is thoroughly dry
Record Your Model
IXL Eco VentfloIXL Eco Ventflo
RECORD THE DETAILS OF YOUR MODEL AND KEEP THE FOLLOWING INFORMATION
DO NOT SEND THIS TO IXL.
Installed By .....................................................................................................................................
Suburb ...........................................................................................................................................
Date of Purchase.............................................................................................................................
Model No..........................................................Serial No.................................................................

12
Warranty Warranrty
IXL Eco VentfloIXL Eco Ventflo
Three Year Replacement Warranty
This Warranty against defects for your newly purchased IXL product is proudly prepared by
IXL Home Pty Ltd of 1/391 Boundary Road, Truganina Victoria 3029, phone 1300 727 421.
1. IXL Home Ventilation products come with guarantees that do not exclude the following consumer
entitlements under the Australian Consumer Law:
a. replacement or refund for a major failure and compensation for any other reasonably foreseeable
loss or damage; and
b. to have the goods replaced if goods fail to be of acceptable quality and the failure does not
amount to a major failure.
2. IXL Home warrants that your product and related supply will be free from defects in materials
and workmanship during the warranty term. Your warranty term is three years commencing from the
date of purchase.
3. Subject to Point 1, IXL Home will during the warranty term provide a replacement of an
equivalent current model where the balance of the warranty period from the original date of
purchase will take effect.
4. To the fullest extent permitted by law and subject always to Point 1, IXL Home will not be
liable for:
a. any loss or damage arising from loss of use, loss of profits or revenue; or
b. for any indirect or consequential loss or damage resulting from any breach of this warranty
against defects.
5. Defective IXL Home products may be replaced by a refurbished product of the same type.
Limitations to Your IXL Warranty
6. Subject to Point 1, this Warranty:
a. will only be provided to the original purchaser where the original purchase was made from a
IXL Home Authorised Dealer or Reseller and proof of such purchase can be presented at the time
of service;
b. only applies to IXL Home products purchased in Australia from a IXL Home Authorised Dealer
or Reseller;
c. will not apply where the defect in or failure of the product is attributable to misuse, abuse,
accident or non-observation of the manufacturer’s instructions. This product must be used
in accordance with the manufacturer’s instructions;
d. will not cover faults due to normal wear and tear with reasonable use nor consumable
components such as globes, filters, glass items, etc;
e. will not cover any damages or problems caused to this product by natural forces eg. storm, fire,
flood, and earthquake; or by intrusion or accumulation (or both) of foreign matters eg. dust, soil,
and moisture. IXL Home recommends that you take out appropriate insurances to protect
your product to this end;
f. will not apply if this product is installed in a mobile dwelling eg. caravan or boat;
g. will not apply if this product is removed from the location where it was first installed;
h. covers use of this product for domestic use only;
i. will not be restarted or extended upon replacement of the product or a part.
How to make a Claim under Your IXL Warranty
7. To make a claim under this Warranty you will need to:
to provide details and register your claim enabling a IXL Home assessment;
b. submit proof of purchase with your claim eg. tax invoice or purchase receipt;
c. where a property has been constructed by a builder/developer and it is fitted with IXL products,
please submit proof of purchase by way of the certificate of occupancy, with your claim.
8. IXL Home will contact you to make arrangements for a replacement product.
Privacy
The privacy of your personal information has always been important to us. To learn more about how we
collect, keep and use your personal information, please obtain a copy of our privacy statement by visiting
our website at www.ixlappliances.com.au.

14
Notes Template for Cut Out
IXL Eco VentfloIXL Eco Ventflo
Notes
IXL Eco Ventflo Template for Cut Out
IXL Eco Ventflo
14

Part number 611030 Issue D..
For comments, questions or warranty matters:
IXL Home Pty Ltd
Phone: 1300 727 421
www.ixlappliances.com.au
© Copyright IXL Home, 2016
Approved by the appropriate
electrical supply authorities.
Part number 611030 Issue C.
For comments, questions or warranty matters:
Sampford IXL Pty Ltd
Service Department
1/391 Boundary Road
Truganina Victoria 3029 Australia
Phone: 1300 727 421
Fax: 1300 727 425
www.sampfordixl.com.au
© Copyright Sampford IXL, 2015
Approved by the appropriate
electrical supply authorities.
This manual suits for next models
1
Table of contents
Other IXL Fan manuals
Popular Fan manuals by other brands

Orava
Orava SF-200 instruction manual

Kichler Lighting
Kichler Lighting Emerson HIGH COUNTRY owner's manual

Fisher
Fisher F-ERVXQ-D200 Technical manual

Faro Barcelona
Faro Barcelona palk manual

BV
BV BV-BF-01 instructions

Home Decorators Collection
Home Decorators Collection HARRINGTON 59236 Use and care guide