IXL Eco Ventflo 200 User manual

User Guide
IXL Eco Ventflo
Model: 10324 (200mm) - Extraction Rate: 340m3/h
Model: 10326 (250mm) - Extraction Rate: 490m3/h
Electrical Rating: 230~240 V. 50 Hz.

Welcome
Thank you for buying this IXL Eco Ventflo Fan. Even if you have used an exhaust fan before, there are
some very good reasons to read this user guide before using this one:
• Youandyourfamily,propertyandhomewillbesafefromharm.
• Youwilllearnhowthisappliancemaydifferfromothers.
• ByusingtheVentoFanfullyandproperly,youwillgetmaximumlifeandvaluefromit.
• OurwarrantydependsonyouusingtheVentoFanaccordingtothisuserguide.
Itwillonlytakeyouafewminutes,sopleasereadon!
Contents
Safety ............................................................................Pg 3-4
Ventilation Requirements................................................ Pg 5
Clearances ....................................................................... Pg 6
Flat Roof Installations ..................................................... Pg 7
Electrical Requirements .................................................. Pg 7
Wiring Diagrams.............................................................. Pg 8
Installation....................................................................... Pg 9
Use.................................................................................. Pg 10
Cleaning ......................................................................... Pg 10
Record Your Model ........................................................ Pg 11
Warranty ...................................................................Pg 12-13
Notes .............................................................................. Pg 14
Template for Cut Out...................................................... Pg 15
Safety
IXL Eco Ventflo
Read through these instructions fully before commencing installation.
LocatetheIXLEcoVentoinaccordancewiththerequirementsofthecurrentAustralian/NewZealand
WiringRulesAS/NZS3000relatingtodampsituations,oraccordingtoapplicableWiringRulesfor
installationsoutsideofAustraliaandNewZealand.ThisappliancehasanIPX4ratingwhichmeansitis
suitableforZone1installationsandcanbemounteddirectlyaboveabathorshowerrecess.
Thisunitisttedwithacordandplug,however,anyinterconnectingwiringandswitchesusedmust
be fitted by a licensed electrician.
Switchesandothercontrolsmustnotbelocatedwheretheycanbetouchedbyapersoninthebath
orshower.
Warning:
• Donotusethisapplianceforfunctionsotherthanthosedescribedinthisuserguide.
• Afterremovingtheappliancefromitspackaging,ensurethatitiscompleteandundamaged.
IfindoubtcontactaqualiedelectricianorSampfordIXL.Donotleavepackagingwithinthereach
ofchildrenorinrmpersons.
• Thisapplianceisnotintendedforusebypersons(includingchildren)withreducedphysical,
sensoryormentalcapabilities,orlackofexperienceandknowledge,unlesstheyhavebeen
givensupervisionorinstructionconcerningtheuseoftheappliancebyapersonresponsiblefor
their safety.
• Youngchildrenshouldbesupervisedtoensuretheydonotplaywiththeappliance.
• Donotoperatetheapplianceinthepresenceofinammablevapours
(alcohol,insecticides,petrol,etc.)
• Donotsitorplaceobjectsonorintheappliance.
• Thesupplycordcannotbereplaced.Ifthecordisdamagedtheapplianceshouldbescrapped.
• Donotoperatethisappliancewithouttheplasticsurroundinposition.
• Thisappliancemustbemountedwiththelowestpointatleast2.1metresfromtheoor.
Caution:
• Donotmakemodicationsofanykindtothisappliance.
• Donotexposethisappliancetotheweather(rain,sun,etc.)
• Donotimmersetheapplianceoranypartsofitinwaterorotherliquids.Refertotherelevant
instructionstocleantheappliance(page10)
Do not allow insulation material to rest against the sides or
top of the Ventflo unit when installed.
2

Ventilation RequirementsSafety cont.
Formaximumefciencyandfanperformancethere
areafewkeypointstokeepinmindwheninstalling
your IXL Eco Ventflo exhaust fan.
Sufcientairinletintoroom
Steamwillonlyberemovedifthereissufcientow
of air through the room. Ensure generous inlets exist
throughwindows,ventsorunderthedoor.Airow
pathfrominlettofanshouldideallypassoverthe
steamsources.(SeeFig1.)
Adequateventilationinroofcavity
Itisessentialthatthereisadequatespacewithin
the roof cavity so that exhaust air from the fan can
dissipate.Wherespaceisrestricted,useFig.3
asaguidetominimumrequirementsforadequate
ventilation.
Theroofcavityitselfshouldbewellventilatedto
outside so that moist air can be removed. Local
buildingcodesmayrequireueingtooutsidethrough
roofasperFig.4(page7)foratroofinstallation.
Whereventilationspaceisrestricted
Thisproductisnotrecommendedforinstallation
betweenoorsofmulti-storeydwellings,orwhere
spacewithintheroofcavityisseverelyrestrictedand
aueasperFig.4cannotbetted.IXLhasother
Ventilationproductsavailablethatareparticularly
suitedtoinstallationsbetweenoorsorwherespace
isrestricted.ContactyournearestIXLServiceCentre
on the numbers located on the back of this booklet.
For further details and advice on ventilation products
and tips, visit the IXL Ventilation Selection Guide on
our website: www.sampfordixl.com.au
4
• Iftheappliancedoesnotfunctioncorrectlyordevelopsafault,contactSampfordIXLimmediately.
• Shouldtheappliancebedroppedorsufferaheavyblow,haveitcheckedbyanauthorisedservice
agentforIXLproducts
• Theelectricalsystemtowhichtheapplianceisconnectedmustconformtoapplicablestandards.
• Theelectricalpowersupply/sockettowhichtheapplianceistobeconnectedmustbeableto
providethemaximumelectricalpowerrequiredbytheappliance.Ifitcan’tdothis,contacta
qualiedelectriciantomakethenecessarymodications.
• Switchofftheapplianceattheinstallation’smainswitch:a)iftheappliancedoesnotfunction
correctly;b)beforecleaningtheoutsideoftheappliance;c)iftheapplianceisnotgoingtobeused
for any length of time.
• Theroommusthaveanadequatesourceofreplacementairforthisappliancetofunction
effectively.Moreover,ifthereisanynon-sealedcombustionbasedappliancesuchasawater
heater,gasstove,etc.inthesameroom,airreplacementmustbesufcientforallappliancesto
workeffectivelytogether.
• Keeptheappliance’sinletgrillefreefromdusttoensureoptimumairow
IXL Eco VentfloIXL Eco Ventflo
Fig. 1: Ideal placement of Ventflo.
Sufficient air inlets into room are required.
Shown installed between shower and bath
Shown installed above shower

Clearances
Allappliancesmustbemountedsothatthelowest
pointisatleast2.1mabovetheoor.TheIXLEco
Ventoisdesignedtotaceilingcavitywitha
minimum height of 215 mm (10324) & 260 mm
(10326)wheninstalledinawellventilatedroof
cavity. Where ventilation is restricted, these heights
should be increased by a minimum of 25 mm. This
willallowforthebackdraughtshutterstoopenfully
whentheunitisinoperation.
Additionally,aminimumof40mmclearanceis
requiredbetweenthesidesofthefanandany
adjoiningpartsoftheroofstructure,suchaswalls,
joistsorinsulationbatts.
Figure 3 measurement A:
Model 10324 (Ventflo 200)
215mmmin.wherethereisgoodventilationtothe
sides of the unit.
240mmmin.whereventilationtothesidesofthe
unit is restricted.
Model 10326 (Ventflo 250)
260mmmin.wherethereisgoodventilationtothe
sides of the unit.
285mmmin.whereventilationtothesidesofthe
unit is restricted.
Figure 3 measurement B:
40mmmin.clearanceonallsidestoallowclipsto
fullyrotateoutwards.
DRN
CHK
APP
REL
3rdANGLE PROJECTION
THISDRAWING AND DESIGN
REMAINSTHE PROPERTY OF
SAMPFORDIXL PTY. LTD. THE
INFORMATIONIS CONFIDENTIAL
ANDIS NOT TO BE REPRODUCED OR
DISCLOSEDTO ANY PARTY OUTSIDE
YOURORGANISATION WITHOUT
PRIORWRITTEN AUTHORISATION
FROMSAMPFORD IXL PTY. LTD.
Pty. Ltd.
MATL
NAME
SCALE
SHEET
DRG
ISSUE
SAMPFORDIXL - SHEET SIZE A1
2OF 4
10324 instructions
1:2
A
UNLESSOTHERWISE STATED
DIMENSIONSIN MILLIMETRES
TOLERANCES
LINEAR
HOLEGROUPS
BLANKDIM,S
HOLES
ANGULAR
0.5
0.1
0.2
0.2
0.2
DRN
-
-
-
-
-
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12
-
g
MASS
VENTFLO 200 - AXIAL FAN
VOLUME
mm3
Fig. 2: Adequate open space in the roof cavity
is required
A
B
FLAPS
DRN
CHK
APP
REL
3rdANGLEPROJECTION
THISDRAWING AND DESIGN
REMAINSTHE PROPERTY OF
SAMPFORDIXL PTY. LTD. THE
INFORMATIONIS CONFIDENTIAL
ANDIS NOT TO BE REPRODUCED OR
DISCLOSEDTO ANY PARTY OUTSIDE
YOURORGANISATION WITHOUT
PRIORWRITTEN AUTHORISATION
FROMSAMPFORD IXL PTY. LTD.
Pty. Ltd.
MATL
NAME
SCALE
SHEET
DRG
ISSUE
SAMPFORDIXL- SHEET SIZE A1
1OF 4
10324 instructions
1:1
A
UNLESSOTHERWISESTATED
DIMENSIONSINMILLIMETRES
TOLERANCES
LINEAR
HOLEGROUPS
BLANKDIM,S
HOLES
ANGULAR
0.5
0.1
0.2
0.2
0.2
DRN
-
-
-
-
-
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8 9 10 11 12
-
g
MASS
VENTFLO 200 - AXIAL FAN
VOLUME mm3
Fig. 3: Minimum clearances for installation
IXL Eco Ventflo
Electrical Requirements
Flat Roof Installations
Seethewiringdiagram(Fig.5)forsupplyrequirementsandmaximumloadingsforeachmodel.
Fansmaybeconnectedtoalightingpowercircuitifloadingpermits.Wiringofthewallswitch(not
provided)andsocketoutletinroofcavitymustbecarriedoutbyaregisteredelectrician.Thewall
switchshouldbelocatedinaccordancetheWiringRulesAS/NZS3000.Itmustnotbeinstalledwhere
itcanbereachedbyapersoninthebathorshower.
Wheninstallingintoaatroofwithinsufcient
clearance,orwhereceilingcavityventilationis
restricted, an external venting duct must be installed.
Use Fig. 4 as a guide to minimum external outlet
requirements.
IMPORTANT:Donotattachtheducttothebodyof
thefan.Allowfor10-20mmminimumgapbetween
the fan and the end of the duct. The duct should
have a diameter of at least 235mm (10324) &
290mm (10326).
Fig. 4: Minimum external outlet requirements
IXL Eco Ventflo
6

Wiring Diagrams
Fig. 5: Wiring diagram.
IXL Eco Ventflo
Installation
Important considerations before installing
• Joists,beamsandraftersshallnotbecutornotchedtoinstalltheappliance.
• ThisunithasanIPX4ratingwhichmeansitissuitableforZone1installationsandcanbeinstalled
directlyaboveashowerorbath.
• Fortheexhaustfantoworkefciently,replacementairofavolumeequivalenttowhatisbeing
extractedmustbeabletoentertheroom.Ingeneralthisairwouldbedrawnunderthedooror
throughaslightlyopenwindow.Iftheroomisairtightthefanwillfunctionpoorly.
• Thisproductisdesignedforinstallationinatceilingonly.Donotmountitonaslopingceiling
orverticalwall.
Fig. 7: Mounting clips open
Fig. 6: Mounting clips closed
IXL Eco Ventflo
1. Locatingtheunit–Beforecommencingany
cutting,checkintheceilingspacethatthereare
noobstructionssuchasceilingjoistsandthat
there is sufficient clearance for the housing.
Checkthattheelectricalwiringcanberoutedfrom
thewallswitchestothemountinglocation.
2. Preparetheceiling–Usingthetemplateprovided
onpage15,marktheceilingwithapenciloutline
andcutouttherequiredhole(10324needs244
mm dia. & 10326 needs 294 mm dia. hole).
3. Remove the grille.
4. Plugthefanintothepowerpoint.
5. Ensurethatthemountingclipsareintheclosed
position,theninsertfanintoceilingcutout.
6. Usingascrewdriver(orabatterydriverwithalow
torquesetting)partiallytightenthescrews.
Thiswillmovethemountingclipsintotheopen
positionandholdtheunittotheceiling.
7. Rotatetheunitsothatthegrilledirection
linesonthebodyarealignedwiththewalls.
Theselinesshowtheorientationofthefascia
grillewheninstalled.
8. Tightenthescrews.Donotovertightenasthis
candamageplasterboard.
9. Fitgrilleontounit.Oncettedthegrillecanbe
adjustedtobetteralignwiththewalls.
8
10324:0.13A50Hz,10326:0.25A50Hz

1. Turnthepowerswitchon/offtomakesuretheunitruns
2. Runningthefancanexhauststeamandodoursquicklyandefciently.
Note:Shutoffpowerurgentlywhenanyabnormalitiesoccurinoperation.Thencallalicensed
electricianorIXLservicepersonforinspectionandnecessaryservicework.
Donotinsertngersorthinbarsintothegrillewhentheunitisoperating.Thiscouldcauseharmto
yourselfandtheappliance.
Theunitmustnotbeinstalledinaplacethatsuffersfromseverewaterleakage.
1. Shutpoweroffbeforecleaningormaintenance.
2. Removegrilleandwipeitwithcareusingadampsoftclothwithamilddetergentifnecessary.
Ensurethemotororotherelectricalpartscan’ttouchthewater.
3. Thegrillecanbecleanedinadishwasheronlowheatsetting~45°Candonlywashonthetopshelf.
4. Replacethegrilleafteritisthoroughlydry
Use
Cleaning
IXL Eco Ventflo
10
Record Your Model
RECORD THE DETAILS OF YOUR MODEL AND KEEP THE FOLLOWING INFORMATION
DO NOT SEND THIS TO IXL.
InstalledBy ............................................................................
Suburb ................................................................................
DateofPurchase........................................................................
ModelNo.........................................SerialNo ..............................
IXL Eco Ventflo

Warranty
IXL Eco Ventflo
Warranty
ThreeYearReplacementWarranty
ThisWarrantyagainstdefectsforyournewlypurchasedIXLproductisproudlypreparedby
SampfordIXLPtyLtdof421SmithStreet,Fitzroy,VIC3065,phone1300727421.
1. SampfordIXLVentilationproductscomewithguaranteesthatdonotexcludethefollowing
consumerentitlementsundertheAustralianConsumerLaw:
a.replacementorrefundforamajorfailureandcompensationforanyotherreasonably
foreseeable loss or damage; and
b.tohavethegoodsreplacedifgoodsfailtobeofacceptablequalityandthefailuredoesnot
amounttoamajorfailure.
2. SampfordIXLwarrantsthatyourproductandrelatedsupplywillbefreefromdefectsin
materialsandworkmanshipduringthewarrantyterm.Yourwarrantytermisthreeyears
commencingfromthedateofpurchase.
3. SubjecttoPoint1,SampfordIXLwillduringthewarrantytermprovideareplacementofan
equivalentcurrentmodelwherethebalanceofthewarrantyperiodfromtheoriginaldateof
purchasewilltakeeffect.
4. TothefullestextentpermittedbylawandsubjectalwaystoPoint1,SampfordIXLwillnotbe
liable for:
a.anylossordamagearisingfromlossofuse,lossofprotsorrevenue;or
b.foranyindirectorconsequentiallossordamageresultingfromanybreachofthiswarranty
against defects.
5. DefectiveSampfordIXLproductsmaybereplacedbyarefurbishedproductofthesametype.
LimitationstoYourIXLWarranty
6. SubjecttoPoint1,thisWarranty:
a.willonlybeprovidedtotheoriginalpurchaserwheretheoriginalpurchasewasmadefroma
SampfordIXLAuthorisedDealerorResellerandproofofsuchpurchasecanbepresentedat
the time of service;
b.onlyappliestoSampfordIXLproductspurchasedinAustraliafromaSampfordIXL
AuthorisedDealerorReseller;
c.willnotapplywherethedefectinorfailureoftheproductisattributabletomisuse,abuse,
accidentornon-observationofthemanufacturer’sinstructions.Thisproductmustbeusedin
accordancewiththemanufacturer’sinstructions;
d.willnotcoverfaultsduetonormalwearandtearwithreasonableusenorconsumable
componentssuchasglobes,lters,glassitems,etc;
e.willnotcoveranydamagesorproblemscausedtothisproductbynaturalforceseg.storm,
re,ood,andearthquake;orbyintrusionoraccumulation(orboth)offoreignmatterseg.
dust,soil,andmoisture.SampfordIXLrecommendsthatyoutakeoutappropriateinsurances
toprotectyourproducttothisend;
f. willnotapplyifthisproductisinstalledinamobiledwellingeg.caravanorboat;
g.willnotapplyifthisproductisremovedfromthelocationwhereitwasrstinstalled;
h.coversuseofthisproductfordomesticuseonly;
i. willnotberestartedorextendeduponreplacementoftheproductorapart.
IXL Eco Ventflo
12
HowtomakeaClaimunderYourIXLWarranty
7. TomakeaclaimunderthisWarrantyyouwillneedto:
a.contactSampfordIXLservicedepartmenton1300727421or
[email protected]toprovidedetailsandregisteryourclaim
enablingaSampfordIXLassessment;
b.submitproofofpurchasewithyourclaimeg.taxinvoiceorpurchasereceipt;
c.whereapropertyhasbeenconstructedbyabuilder/developeranditisttedwithIXL
products,pleasesubmitproofofpurchasebywayofthecerticateofoccupancy,
withyourclaim.
8. SampfordIXLwillcontactyoutomakearrangementsforareplacementproduct.
Privacy
Theprivacyofyourpersonalinformationhasalwaysbeenimportanttous.Tolearnmoreabouthow
wecollect,keepanduseyourpersonalinformation,pleaseobtainacopyofourprivacystatementby
visitingourwebsiteatwww.sampfordixl.com.auorbycontactingusviaemailoninfo@sampfordixl.
com.auorbytelephoneon1300727421.

Notes
IXL Eco Ventflo Template for Cut Out
IXL Eco Ventflo
14

Part number 611030 Issue A.
Forcomments,questionsorwarrantymatters:
Sampford IXL Pty Ltd
ServiceDepartment
421SmithSt
FitzroyVictoria3065Australia
Phone:1300727421
Fax:1300727425
aftersalesservice@sampfordixl.com.au
www.sampfordixl.com.au
Approved by the appropriate
electrical supply authorities.
This manual suits for next models
3
Table of contents
Other IXL Fan manuals
Popular Fan manuals by other brands

Caframo
Caframo Ecofan 815 operating instructions

Prominence Home
Prominence Home Mandino owner's manual

Honeywell
Honeywell HTF090 Series owner's manual

Home Decorators Collection
Home Decorators Collection BENTLEY III AM183W-BN Use and care guide

Minka-Aire
Minka-Aire Concept I Wet F476L-BNW instruction manual

Fantech
Fantech FIT 120E manual