Configuring interSeptor via the Serial Port
1. Start a Hyperterminal session on your Windows PC.
2. Enter a name or the interSeptor session and press
“OK”.
3. Select the correct COM port and press “OK”.
4. Con igure the port settings as shown (9600, 8,
None, 1, None) and press “OK”.
5. Set DIP switches on the rear panel o the interSeptor
to SW1=OFF, SW2=OFF.
6. Power up the interSeptor
7. Enter the de ault password “admin” and at the
prompt enter “1” and press enter, then press “1”
and enter again to open the System Group menu.
8. Assign an IP address or interSeptor, and the correct subnet mask.
NOTE: Both PC and interSeptor P addresses must be on the same P subnet.
9. Enter “0” and back to the interSeptor Configuration menu.
10. Enter “2” to go to the Control Group menu.
11. Disable the “BOOTP / DHCP” option.
12. Con igure the HTTP username using “HTTP login username”.
13. Con igure the administrator password using “Community read / write”.
14. Enter “0” and return, three times to exit.
15. Connect the interSeptor to the network using a standard CAT5 straight through
cable.
NOTE: The interSeptor email alerts facility is configurable through the browser
interface only.
Configuring interSeptor on the Network
1. Make sure that you have a TCP/IP network already installed.
2. interSeptor will initially try to acquire an IP address rom the DHCP network
service, i it exists on the network, unless the “BOOTP / DHCP” option has been
disabled.
NOTE: You can run the "iupgrade.exe" program provided on the interSeptor CD-
ROM to display the interSeptor’s current P address.
3. I a DHCP network service is not available, enter the ollowing command at the
DOS prompt:
route add 172.17.XXX.ZZZ <Workstation’s P address>
NOTE: The default P address of interSeptor is 172.17.XXX.ZZZ where XXX and
ZZZ are the last two pairs of the MAC address of the interSeptor in decimal.
The MAC address can be found on the bottom of the interSeptor (e.g.
00E0XXXXXXXX).
4. Enter TELNET <interSeptor’s IP address> at the DOS prompt and press enter.
5. TELNET uses the same inter ace as serial port con iguration.