Japan' Gold 4.0 User manual

Electronic Heater User Guide
JAPAN’ GOLD 4.0
(English version)
production - Japan - 2018
1 page

Trademarks and brands
Specification
Model: JAPAN’ GOLD 4.0
Net weight: 112 gram;
Size: W22*L108 mm;
Battery capacity: 1350mAh;
Incoming voltage: 5V/500mA;
Charging time: about 3 hours;
Heating time: 15 seconds;
Smoking time: 5 minutes.
Fully charged device rated 16-20 cigarette sticks for
use.
Standard configuration
2 page

JAPAN’ GOLD 4.0. LED flashing control
High surface temperature of the heat
shield
Standard temperature ranges for different power supply methods:
- The surface temperature of the heat shield in the high voltage supply
mode should be approximately 33-38°С;
- The surface temperature of the heat shield in the medium voltage mode
should be approximately 31-36°С;
- The surface temperature of the heat shield in the mode of supplying a
small voltage should be approximately 28-33°C.
When the power button is turned on,
red flashes 15 times
Insufficient battery charge, you need to charge it.
When the power is turned on, the red
color flashes 3 times
1. Missing heater, install it.
2. Heater is loose, achieve a tight fit, and start the procedure again.
3. Heater out of order, replace it.
When you press the power button 3
times, the light diode does not turn
on
The device has failed broken. Contact technical service.
Charging indicator does not turn on
This may be due to spontaneous discharge. At the same time, the
battery becomes so discharged due to a long interruption in its use.
Fully charge the battery for 3 hours and the device will be ready for use.
If this does not happen, then the device is probably out of order. Please
contact technical service!
Application
Start smoking slowly, you do not need to do sharp drags as it was when
smoking regular cigarettes. Tightening should be smooth and not deep in
the floor of the pharynx, do not rush. The slower you tighten, the better
the needle manages to warm up the tobacco. Relish every sip. Then you
will achieve the full effect.
The error of smokers they start to do sharply several drags in a row
expecting that smoke will become more. Here is another principle. The
slower you drag on, the more and thicker the smoke. Between puffs,
pause for 30-40 seconds; the longer the pause, the more the needle
manages to heat up and the taste of the tobacco improves. After 5-6
puffs, ash is formed near the needle and the needle needs to warm up
for 40-50 seconds more, so do not rush to smoke quickly, time is
sufficient and there is an additional mode of smoking.
If you hold the smoke in your lungs for 10-15 seconds, the effect will be
very good. After 5 puffs, you will feel a little dizzy. This “Nicotine” has
begun to act. Smoke slowly, the whole effect in a quiet smoking and
3 page

enjoying savor every breath of smoke. When you hold it in, the smoke
dissolves faster and tobacco gives the full effect.
Basic operations
№1. Switch ON/OFF
To preheat the device, press the power button 3 times within two seconds. After the preheat is completed, the LED
will start flashing slowly. You will hear a single vibration device. The light diode is burning steadily, which means that
you can start smoking.
The recommended smoking duration for which the JAPAN' GOLD 4.0 model is designed is 5 minutes. Before you
finish the process of smoking, a single vibration of the device will occur, which warns you that it is possible to make
two puffs. After the red light flashes five times, you need to remove the cover with the stick up, then remove the used
tobacco stick from the heat shield and discard it.
If in the process of smoking there is a desire to take a break, the power button must be quickly pressed three times.
In this case, white light flashes three times, which means that the device is turned off. But in this case, unused
tobacco stick should not be reused. It is better to replace it with a new stick. Re-stick can be used only after 3-5 puffs
no more.
№2. Mode switching
There are two modes of operation. To change the mode of operation, you need to press the power button 5 times
within 3 seconds in the standby mode and the light diode will begin to burn steadily for two seconds. Green light is a
high voltage supply mode, blue light is a medium mode (By default, an average power current is applied). In the
process of smoking mode switching is not supported.
№3. Power Status
To check the current power status, press the power button once. The light diode will light up for two seconds. (Green
light is responsible for the high power supply mode, blue light is connected to the average power supply). (The
default current is medium power). During the smoking process, the power mode check is not supported.
№4. Battery condition
Quickly press the power button twice. In this case, the red light lights up for two seconds, thereby indicating that
power is present. Green light indicates that the battery is charged at 60 percent or more. Blue light indicates a
charging range from 20 to 60 percent. Red light warns of low charge - below 20 percent.
№5. Charging
Even before the smoking process, the system will detect that the battery voltage is too low 3.2 volts, the red light
flashes 15 times, thus reminding you to charge, and after that the device turns off automatically. In this case, be sure
to charge the device. There are two ways to charge: via USB and via Wi-Fi (supplied separately). Red light blinks
during charging.
After charging is complete, the light turns off for 5 minutes. Do not smoke during the charging process. Achieving full
charge can last about 3 hours. Full charge is designed to use 16-20 tobacco sticks.
4 page

№6. Protection function
If the heater is subjected to a short circuit, poor contact or is not installed, press the power button 3 times. In this
case, the red light flashes 3 times and the device turns off. If the charging process stretches for 4.5 hours or more,
the charging process stops automatically.
№7. Self cleaning function
Fully charge the device, open the heat shield and start the self-cleaning procedure by pressing the power button 8
times.
During self-cleaning, the white light will flash. When the self-cleaning procedure is completed, the white light will turn
off and the red light will flash.
(!) In order not to burn yourself, do not touch the heating element during the cleaning process.
(!!) This function is used only once for each cleaning. Do not resort to it constantly.
To make sure that the device is cold, you need to wait 5-15 minutes. Use a wet wipe, swab, special paper, or other
cleaning products to clean the heat shield and heating element. Then, put the heat shield back in place. It is
recommended to resort to the self-cleaning procedure once in two days.
№8. Heater Replacement
As a result of prolonged use, when the sensation of smoking and taste may deteriorate. Therefore, it is
recommended to clean the heater or replace it.
Unscrew the heater in a counterclockwise direction. If you are going to replace the heater, this procedure should be
carried out after 5–15 minutes after the end of smoking, when the device is considered to have cooled down.
Additional heater sold separately.
Precautions
- Model JAPAN' GOLD 4.0 consists of specific circuits and components. If the manufacturer himself has not
foreseen any action in relation to any model, do not disassemble the device yourself. We are not responsible for
malfunctions and breakdowns that occurred or may occur as a result of self-disassembly of the product;
- This device may not be used by anyone under the age of 18;
- To achieve optimal smoking and taste, make sure that the tobacco sticks are dry. Otherwise, the sensation and
taste of tobacco in the process of smoking will not be satisfactory.
5 page
Table of contents
Other Japan' Gold Electronic Cigarette manuals