Installing Cabinetry Over Your Electrical Wiring Information
Jenn-Air Grill Theneutralofthisunitisgroundedtotheframethrough
the green grounding wire. If used on newbranch-circuit
A = 30"(76.2 cm) minimum clearance between the top of installations (1996 NEC), mobile homes, recreational
the cooking platform and the bottom of an vehicles, or in an area where local codesprohibit
unprotected wood or metal cabinet, grounding through the neutral conductor, untwist or
disconnect the green wire and connect the green wire to
A = 24"(60.96 cm) minimum when bottom of wood or
metal cabinet is protected by not less than 1/4"ground in accordance with local code. Connect the white
(0.635 cm). FLAME RETARDANT millboardcovered neutraltotheserviceneutral.Connect all wires to the
with no less than no. 28 MSG sheet steel, 0.015" branch circuitwith approved connectors. Use copper or
(0.038 cm) stainless steel, 0.024"(0.061 cm) aluminum wire. If aluminum wire is used, use connectors
aluminum or copper, recognized for joining aluminum tocopper.
*To eliminate the risk of burns or fire by reaching over
heated surface units, cabinet storagespace located Proper Electrical Supply
above the surface units should be avoided.If cabinet You must provide an adequate electrical supply system
storage is to be provided, the risk can be reduced by as required for your cooktop. All wire connections must be
installing a range hood that projects horizontally a in accordance with local codes and properly insulated.
minimum of 5 inches beyond the bottom ofthe cabinets.Checkwith local utility for governing electrical codes and
ordinances. In the absenceof local electrical codes, the
National Electrical Code,NFPA No.70, governing electric
DOTTEDLINES Fcooktop installations must be followed.A copy of the
[NDICATE
RANGEHOOD I_ National Electrical Code, NFPA No. 70,can be obtained
CONSTRUCTION_ by writing to:
t National Fire Protection Association
* A BatterymarchPark
Quincy, Massachusetts 02269
I
A three-wire, single phase, A.C. 1201240 volt 60 cycle
electrical system (properly circuit protectedto meet local
Installer Installation Suggestions Codes of NFPA No. 70)must be provided. Unit must be
1.Chamferallexposededges ofdecorativelaminateto properlygroundedinaccordancewithlocalwiringcode,
preventdamagefromchipping. Thechartbelowrecommendsthe minimumcircuit
protector and wire size if the appliance isthe only unit on
2.Radius corners of cutout and file to insure smooth the circuit.If smaller sizes of wire are used, the unit
edges and prevent corner cracking, efficiency will be reduced and a fire hazard may be
created. It is advisable that the electrical wiring and
3. Roughedges, inside corners which have not been hookup be accomplished by a competent electrician.
rounded and forced fits can contribute to cracking of
the countertop laminate.
4. Countertop must be supportedwithin 3"(7.62 cm) of
cutout. RECOMMENDEDMINIMUM
K,W.RATING CIRCUITPROTECTION WIRESIZE
CAUTION o. SERIALPLATE INAMPERS(AWG)
Warrantyis voidon Jenn-Airequipment 0- 4.9 2012
installedotherthan as recommendedby 5.0- 6.9 30 10
manufacturer.Recommendedwallcapsand 7.O-9.9 408
transitions must be utilized for proper lO,0-11.9 50 8
operationandinstallation. 12.0-14.9 60 6