THIS PRODUCT CAN BE DANGEROUS IF NOT USED PROPERLY!
Always wear appropriate Personal Protective Equipment (PPE). Detailed
PPE information can be found at: www.fsesgsafety.com and clicking on
the JETSTREAM name or by referring to the yellow JETSTREAM SAFETY
WARNING pamphlet (PI-082).
This product is sold with the understanding that the purchaser agrees to thoroughly
train all operators and maintenance personnel in the correct and safe installation,
operation, and maintenance of the product and to provide adequate supervision of
personnel at all times. JETSTREAM urges customers to make complete instruc-
tions available to all personnel and that all instructions are read thoroughly before
installing, connecting or using the Versaboom. Retain these instructions for future
reference. If this product is resold or otherwise conveyed, the purchaser must pass
on these instructions to the new user. If any questions remain or for additional cop-
ies, call JETSTREAM at (800) 231-8192 or (832) 590-1300.
Read the yellow JETSTREAM SAFETY WARNING pamphlet included with the
shipment of the product.
OPERATION
As per the WJTA-IMCA Recommended Practices, all operators shall follow the
OSHA regulations for personal protective equipment. (OSHA guidelines for Per-
sonal Protective Equipment are available in document number 3151-12R 2004,
which can be obtained from www.osha.gov.) All operators shall be issued suitable
head protection, eye protection,hearing protection, body protection, hand and foot
protection and respiratory protection (if needed). For detailed specications on all
protections required, refer to the WJTA-IMCA ‘Recommended Practices for the
Use of High Pressure Waterjetting Equipment’ Section 6, Protective Equipment For
Personnel.
SETUP/OPERATION:
The VersaBoom is designed to hold and position a 3D waterblast tool on the
end of a ½” or 13mm waterblast hose. With the use of extension tubes, offset
distances of up to 10 feet from the manway can be achieved.
The length of the extension tube above the ball pipe (Item 6) should allow for an-
choring to a nearby structure and a safe position for the operator when adjusting
the device. The length of the extension tube below the positioning ball will be de-
termined by the desired cleaning nozzle position inside the vessel. The baseplate
(8) should be securely attached to the manway using bolts or clamps.
1. Pass hose end through the gland (Item 12), nipple (10), anchor coupling (5),
2’ extension tube (16), coupler (4), and ball pipe (6)
2. Hose enters split end of elbow (7) and through lower extension tube (16/17)
and outlet tting (11)
3. Install collet (8 or 9 depending on hose size) between nipple (10) and gland
(12).
4. Connect all 1-1/2” NPT pipe connections together securely
5. Align lower extension tube with lower slot in ball pipe and tighten the bolt (3)
in the split end of elbow.
6. Attach waterblast tool to hose end.
The operator can adjust the position by loosening the cap (6), pivoting the as-
sembly into the desired position and tightening the cap. Use the anchor loops on
the anchor coupling (5) to hold the position of the ball. The hose can be extended
or retracted in the vessel by loosening the collet (8/9) with the gland wrench (12).
Make sure all clamps and joints are securely tightened and the hatch is secured
before operation. An aluminum hatchway is provided to view the tool location
within the vessel and to check on the cleaning process.
!!CAUTION
1. Securely attach baseplate to vessel manway ange with bolts or clamps.
2. Anchor upper extension tube to nearby structure with chain or similar
restraint using loops on anchor coupling.
3. To maximize stability, keep upper and lower extension tubes and anchor
attachment in the same plane.
4. When collet is loosened, hose will slide freely through the ball. It must be
supported by hand.
5. Make sure all clamps and joints are securely tightened and the hatch is
secured before operation.
6. Always shut down pump before the cleaning head is repositioned.
!!CAUTION
DO NOT use the Versaboom™ if it has not been cleaned and inspected
prior to starting the working shift.
For further info see:
https://www.youtube.com/user/JetstreamWaterblast
and
Jetstream Safety Manual
Jetstream of Houston LLP • 5905 Thomas Road Houston, TX 77041 www.waterblast.com • 1-832-590-1300
QSG-201 VERSABOOM™QSG-201 VERSABOOM™ QSG-201 VERSABOOM™QSG-201 VERSABOOM™PART BREAKDOWN - BASE PLATE ASSY (PN 67936)PART BREAKDOWN - BASE PLATE ASSY (PN 67936)
Item Qty Part Number Description
19 626565 Capscrew
20 462778 Socket Head
21 464382 Capscrew
22 267906 Hex Nut
23 167909 Base Ring
24 167910 Cap
25 467911 Pipe Handle
26 167912 Base Plate
27 167913 Hatch
28 167914 Hatch Ramp, Left
29 167915 Hatch Ramp, Right
30 167917 Hatch Handle
31 267918 Plunger, Hatch Lock
32 267993 Hatch Latch Assy
33 10 71391 Nut