JNGE Power JN-MPPT User manual

Anhui JNGE POWER CO.,LTD.
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
JN-MPPT Buck Solar Chagre Controller
Host computer communication instructions

JN-MPPT Buck type Solar Controller Product Manual
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
- 1 -
Contents
The first part: hardware connection........................................................................................................... - 2 -
1. RS485 communication connection..............................................................................................- 2 -
2.Connection between the device and the PC...............................................................................- 2 -
The second part: parameter configuration................................................................................................- 3 -
1. the installation of the software..................................................................................................... - 3 -
2. the introduction of the software interface................................................................................... - 3 -
3.Parameters configuration...............................................................................................................- 4 -
3.1 Communication parameter setting:..................................................................................... - 4 -
3.2 System Settings:.....................................................................................................................- 5 -
3.3 System parameter setting:....................................................................................................- 6 -
3.4 Query function:....................................................................................................................... - 7 -
The third part, parameter monitoring......................................................................................................... - 8 -
1. real-time running data................................................................................................................... - 8 -
2. Real-time running parameter curve.............................................................................................- 8 -
3. Historical data................................................................................................................................. - 9 -
Note: This operation manual guides the user to use the host computer to view the working status of the
device and set the parameters of the device.

JN-MPPT Buck type Solar Controller Product Manual
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
- 2 -
The first part: hardware connection
1. RS485 communication connection
The controller device uses the RJ45 interface (RS485 communication protocol) to communicate with the
host computer:
Figure 1-1 RJ45 interface (RS485 communication protocol)
2.Connection between the device and the PC
Use the special network cable (1.5 meters) in our accessories to communicate with the RJ45 to USB
interface converter (RS485 communication protocol) to realize communication between the controller
and the host computer. See the wiring diagram below for details:
Figure 1-2 RJ45 to USB interface converter (RS485 communication protocol)
Figure 1-3 Device and PC connection diagram
Note: the special network cable crystal head blue sheath termination controller device, black sheath
termination RJ45 to USB converter, RJ45 to USB converter USB port and computer USB port plug-in
connection;
Warning:
It is forbidden to use any network cable as the communication cable to connect the device directly to the
PC monitoring port. Otherwise, the device and PC will be damaged!

JN-MPPT Buck type Solar Controller Product Manual
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
- 3 -
The second part: parameter configuration
1. the installation of the software
First put the CD that came with the controller into the CD-ROM drive of the computer, then read the
information on the CD-ROM and assemble the four installation programs in sequence.
2. the introduction of the software interface
After the software installation is complete, double-click the “Solar MPPT Controller Monitoring Software”
shortcut icon on the desktop of the computer to open the monitoring software operation interface.
Figure 2-1 Software interface diagram
Step
Program
Remarks
1
USB serial port driver
2
Microsoft Access database plugin
3
Installation Tip: This computer has
a newer version of the software
installed, no need to install it;
4
Solar MPPT Controller Monitoring
Software

JN-MPPT Buck type Solar Controller Product Manual
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
- 4 -
The software interface is shown in the figure above. The main interface area is divided into menu bar,
status bar, device tree, operation parameter, and fault alarm display area.
Menu bar: Edit and run parameters, the functions are as follows:
3.Parameters configuration
3.1 Communication parameter setting:
Click the “Communication Settings” menu in the menu bar to pop up the “Serial Port Settings” submenu.
Click the “Serial Port Settings” submenu to pop up a serial port setting dialog box, as shown below:
Figure 2-2 Serial Port Settings
Click the drop-down box next to “Serial Port” and select the corresponding serial port number (you can
also find the serial port number of the device connected to the computer through “Device Manager”), and
then click “Save Settings” to complete the serial port setting.
In this setup page, you only need to change the serial port number. Other parameters do not need to be
changed.
The default value is: baud rate: 9600
Check digit: None
Data bits: 8
Stop position: 1
Menu Item
Function
Rem
arks
System
Add, delete, edit devices;
Communic
ation
settings
Edit communication parameters, including serial port number, serial port
parameters, etc.
Parameter
settings
Read and edit set operating parameters, including battery parameter
settings and device parameter settings;
Search
Query and edit historical data, as well as export report functions.

JN-MPPT Buck type Solar Controller Product Manual
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
- 5 -
3.2 System Settings:
Click the “System” menu in the menu bar to pop up the submenu. The submenu includes two menus
“Add Device” and “Language”. Click the “Add Device” submenu system to pop up the “Add Settings”
dialog box, as shown below figure2-3. As shown; click on the "Language" submenu to switch between
Chinese and English.as shown below figure2-4.
Figure 2-3 Add Device
Enter the device ID in the device ID field. (The device ID must be viewed on the JN-MPPT device first. It
cannot be set arbitrarily. The default value of the JN-MPPT is 6, edit the device name, and click the
“Add” button to complete. Device addition
Select a device in the device list, and display the parameters of the device in the device ID and device
name. If you want to modify it, modify it directly in the corresponding column, and then click the “Modify”
button to complete the modification of the device parameters.
Select a device in the device list and click the "Delete" button, then the device will be deleted.
Note: The device ID is the device identification address of JN-MPPT. Once the setting is completed,
please do not change it arbitrarily. Otherwise, the data connection will be abnormal.
Figure 2-4 Operation language settings

JN-MPPT Buck type Solar Controller Product Manual
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
- 6 -
3.3 System parameter setting:
Through the system monitoring software, click the “Parameter Setting”
menu in the menu bar, the system will pop up the “Basic Parameter Setting” and “Factory Setting”
submenu, click the “Basic Parameter Setting” submenu, and the system will pop up “Basic Parameter
Setting”. The dialog box, including “battery parameter setting” and “equipment parameter setting”, reads
and sets the battery and controller parameters, as shown in the following figure 2-5 and figure2-6; click
“factory setting” system will pop up the password input dialog box, The parameter setting is the controller
factory setting parameter and the user does not need to change it.
Figure 2-5 Battery parameter settings
Figure 2-6 Device parameter settings
As shown in the figure, click the “Read” button to read the setting parameters of the current device;
to modify the operating parameters of the device, first select the item to be modified, enter the data to be
modified in the “Setting Value” box, and then click "Confirm Modification" completes the modification of
the parameters;

JN-MPPT Buck type Solar Controller Product Manual
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
- 7 -
In this interface, you can also change the parameters such as “Battery Type”, “Number of Battery
Strings” and “Work Mode” through the pull-down menu; the battery is powered by the lead-acid battery
by default; the working mode defaults to the household mode;
Click the “Restore Factory” button, the system's operating parameters will be restored to the factory
settings.
Note: Please don't modify the device ID address arbitrarily. Otherwise, the communication will be
abnormal. Generally, after the first configuration, you do not need to modify it again. Also, the “Restore
Factory” button should not be clicked because the factory settings are restored. At the same time, the
accumulated parameters such as charging and discharging power will be cleared, please be cautious;
3.4 Query function:
The system monitoring software can query the historical data of the controller. Click the “Query”
button in the menu bar to pop up the “History” submenu, click on the submenu to open the historical data
dialog box, as shown below figure 2-7.
Figure 2-7 History Dialog record
As shown in the figure, in the dialog box, historical data can be queried, exported, deleted, and the
like.
Query phase data: first set the start time and end time (the start time needs to be less than the end
time), and then click “Query time period record” to query the running data of the time period;
Query all records: Click "Query all data" to query all running data;
Import, export, and delete historical data: Click the corresponding button to import, export, and
delete historical records. The exported data format is excel format, so the format of the data table when
importing is also the format of excel.
Note: The amount of data in the history record will be relatively large, so there will be a delay when
the query is created. Please wait patiently. The waiting time depends on the running speed of the
computer. Please be cautious when deleting data. Delete the data. It cannot be recovered. Please export
the data before deleting to avoid data loss, which will bring you unnecessary trouble.

JN-MPPT Buck type Solar Controller Product Manual
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
- 8 -
The third part, parameter monitoring
1. real-time running data
After the hardware is connected, JN-MPPT works normally. After the relevant parameters are
configured, click on the upper left corner of the main interface.“Connected devices” button, if the
communication is normal, the status bar will be displayed in the lower left corner of the main
interface.“COM2 Connection is opened successfully ”, otherwise an error will be reported, showing a red
font“ID6 Communication time out !”。With the device ID6 Communication time out !
After the communication is normal, the main interface displays the operating parameters of the
controller and the corresponding icons:
Figure 3-1 Charging status display
1.1 The photovoltaic icon lights up under the state of photovoltaic charging. Without charging, the PV
panel icon will be dimmed; if the load is turned off, the corresponding load pointing icon will be dimmed.
1.2. The icon lights up, various operating parameter settings are displayed, and the charge and
discharge levels are accumulated at the same time. If an alarm event occurs, the item corresponding to
the fault alarm interface will turn red, as shown above figure3-1.
2. Real-time running parameter curve
The monitoring software can not only monitor the running data in real time, but also provide the main
running parameters in a curved way for the customer to browse; on the right side of the data display
interface, hold down the left mouse button and drag the mouse to open the curve display page.

JN-MPPT Buck type Solar Controller Product Manual
Address: No.99,Yonghe Road,High-Tech Zone,Hefei,Anhui ,China http://www.hfjnge.com
- 9 -
Figure 3-2 How to open the parameter curve interface
In the position of the arrow in the above figure, if you pull it like the left, you can display the curve
interface, and the size of the display area can be pulled at will. As shown below:
Figure 3-3 Parameter curve display mode
In the area of the “Solar MPPT Real-Time Graph”, the graph of the controller is displayed in real time.
3. Historical data
Click the “Query” button on the menu bar to pop up the “History” submenu, click the “History” menu to
query the historical data, and export, import and delete the history,Reference”3.4 Query function”.
Other manuals for JN-MPPT
1
Table of contents
Other JNGE Power Controllers manuals