JVC CL-R813 User manual

32-inch (81. 3 cm) Color LCD Monitor
Instruction Manual
Important
This instruction manual contains important information on how to use the product.
Please make sure to read the safety precautions rst and keep this manual in a safe and easily
accessible place for future reference.
B5A-4312-00
Model: CL-R813BN0UA
CL-R813BN0EA

- 2 -
* All other products and company names are trademarks of their respective owners.
ENGLISH

- 3 - ENGLISH
Contents
Before use ....................................................................................................................................... 4
Safety precautions ....................................................................................................................15
Product security .........................................................................................................................19
Package contents ......................................................................................................................20
Features .........................................................................................................................................21
Names and functions of parts .............................................................................................22
Connecting the cables .............................................................................................................24
Adjusting the monitor angle ................................................................................................26
Monitor information ................................................................................................................27
Reference ......................................................................................................................................32
Operating Principle ...................................................................................................................32
Attaching an arm stand ..........................................................................................................33
Anti-Theft security slot ............................................................................................................34
How to change the fuse .........................................................................................................35
Cable management ..................................................................................................................36
Supported signals .....................................................................................................................37
Connector pin assignment ....................................................................................................38
Technical specication ............................................................................................................39
Hardware / Software compatibility ...................................................................................41
Performance specications ...................................................................................................42
When a failure is suspected... ...............................................................................................43
Cleaning the monitor ...............................................................................................................44
After-sales service .....................................................................................................................45
Disposal of Electrical and Electronic Equipment ..........................................................46

- 4 -
ENGLISH
Before use
Thank you for purchasing our color LCD CL-R813. Please read this manual carefully for
proper use.
For your safety
This manual contains important information on how to use the product. Please make
sure to read the safety precautions rst and keep this manual in a safe and easily
accessible place for future reference.
Indication for use
CL-R813 is intended to be used in displaying and viewing medical images for diagnosis
by trained medical practitioners or certied personnel. It is not meant to be used in
digital mammography.
Caution:
Federal law restricts this device to sale by or on the order of a physician.
Limitation of liability
We are not liable for damages
● arising from re, earthquakes, actions taken by any third party, any other accidents,
intentionally or negligently, improper use of the product by the user, or any use under
other abnormal circumstances,
● (including, but not limited to, loss of business prots, disruption of business, change
or loss of saved data) arising from the use of or inability to use this product,
● arising from disassembling or modifying, the Company does not take any
responsibility.
● arising from the use not described in the instruction manual,
● arising from malfunctions caused by the combination of connecting devices, or
● (related to the time limit, business, decrease in prots, any delay, any information, and
other nancial disadvantages) arising from the use of software provided by us for this
product, even if we have been advised of the possibility of such damages.
Uninterruptible power supply
Instantaneous voltage drop due to, for instance, lightning, could cause a power failure.
We recommend that an uninterruptible power supply system be used to avoid the
failure.
FCC information
FCC (U.S. Federal Communications Commission)
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment o and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
●Reorient or relocate the receiving antenna.
●Increase the separation between the equipment and receiver.
●Connect the equipment to an outlet on a circuit dierent from that to which the

- 5 - ENGLISH
receiver is connected.
●Consult your dealer or an experienced radio/TV technician for help.
FCC Warning
To assure continued FCC compliance, the user must use a grounded power supply cord
and the provided shielded video interface cable with bonded ferrite cores. Also, any
unauthorized changes or modications to this monitor would void the user’s authority
to operate this device.
Supplier’s Declaration of Conformity
Trade Name: JVC
Products: LCD Monitor
Model Name: CL-R813BN0xA
Responsible Party: JVCKENWOOD USA Corporation
1440 Corporate Drive, Irving, Texas 75038
TEL: 678-449-8879
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.
Conformity
This device complies with the requirements of the European Medical
Device Regulation (EU) 2017/745 (“MDR”).
Medical Device Classication: Class I
Manufacturer
JVCKENWOOD Corporation
3-12, Moriya-cho, Kanagawa-ku,
Yokohama-shi, Kanagawa
221-0022, JAPAN
Authorized representative
JVCKENWOOD Deutschland GmbH
Konrad-Adenauer-Allee 1-11, 61118 Bad Vilbel, GERMANY
TEL: +49 6101 4988 228 (German, English)
e-mail: product-compliance@de.jvckenwood.com
This device complies with the requirements of The Medical Devices
Regulations 2002 (SI 2002 No 618, as amended) (UK MDR 2002).
Medical Device Classication: Class I
Manufacturer
JVCKENWOOD Corporation
3-12, Moriya-cho, Kanagawa-ku,
Yokohama-shi, Kanagawa
221-0022, JAPAN
UK Responsible Person
JVCKENWOOD U.K. Limited
First Floor, Gleneagles, The Belfry, Colonial Way, Watford, Hertfordshire
WD24 4WH, UNITED KINGDOM

- 6 -
ENGLISH
Warning
●This apparatus must be earthed because of Class I equipment.
●This apparatus is not a patient contact equipment.
●When using at 240 V in the United States, supply must be from center-tapped, 240 V,
single phase circuit.
●Consult your dealer about waste disposal.
●This apparatus shall not to be used in the vicinity of the patient, which is the space
with surfaces likely to be contacted by the patient or an attendant who can touch the
patient. This encloses a space within the room 1.83 m (6 feet) beyond the perimeter of
the bed in its intended location, and extending vertically 2.29 m (7-1/ 2 feet) above
the oor.
Equipment classication
●Type of protection against electric shock: Class I equipment
●Protection against harmful ingress of water: Ordinary Equipment (IPX0)-No
protection.
●Not suitable for use in the presence of ammable anesthetics or oxygen.
●Mode of operation: Continuous operation.....,,,..
Power Cord Important Information
CAUTION: Please use the power cord provided with this monitor in accordance with
the table below. If a power cord is not supplied with this equipment, please
contact your supplier. For all other cases, please use a power cord that
matches the AC voltage of the power outlet and has been approved by and
complies with the safety standards of your particular country. When you
use this monitor for medical in North America, you should use a North
America Hospital Grade power cord.
Country U.S.A./Canada EU Japan
Plug Shape or
Standard UL/CSA VDE, Demko,
Nemko, BSI, etc. PSE
Voltage 120 230 100
Note This product can only be serviced in the country where it was purchased.

- 7 - ENGLISH
EMC Performance
WARNING
• This product requires special EMC precautions and needs to be installed and used
according to the following information.
• Use of accessories, transducers and cables other than those specied or provided by the
manufacturer of this equipment could result in increased electromagnetic emissions or
decreased electromagnetic immunity of this equipment and result in improper operation.
• Cable length: 3.0 m or less.
• Use of this equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this equipment and
the other equipment should be observed to verify that they are operating normally.
• Portable RF communications equipment (including peripherals such as antenna cables
and external antennas) should be used no closer than 30 cm (12 inches) to any part of the
model CL-R813 including cables specied by the manufacturer. Otherwise, degradation of
the performance of this equipment could result.
• Any additional equipment connected to this product needs to comply with the
requirements of IEC 60601-1-2:2014/EN 60601-1-2:2015.
Environments of Intended Use
The model CL-R813 is intended to be used in Home healthcare environment such as
residences and nursing homes.
Guidance and Manufacturer’s Declaration -
Electromagnetic Compatibility
Guidance and manufacturer’s declaration – electromagnetic emissions
The model CL-R813 is intended for use in the electromagnetic environment specied below. The
customer or the user of the model CL-R813 should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment
– guidance
RF emissions CISPR 11 Group 1 The model CL-R813 uses RF energy only
for its internal function. Therefore, its RF
emissions are very low and are not likely
to cause any interference in nearby
electronic equipment.
RF emissions CISPR 11 Class B The model CL-R813 is suitable for use in
all establishments, including domestic
establishments and those directly
connected to the public low-voltage
power supply network that supplies
buildings used for domestic purposes.
Harmonic emissions
IEC 61000-3-2
Class D
Voltage uctuations/icker
emissions
IEC 61000-3-3
Complies

- 8 -
ENGLISH
Guidance and manufacturer’s declaration – electromagnetic immunity
The model CL-R813 is intended for use in the electromagnetic immunity environment (Home
healthcare environment dened in IEC 60601-1-2) specied below.
The customer or the user of the model CL-R813 should assure that it is used in such an
environment.
Immunity test IEC 60601 test level Compliance level
Electromagnetic
environment
–guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
±8 kV contact
±15 kV air
±8 kV contact
±15 kV air
Floors should be wood,
concrete or ceramic
tile. If oors are
covered with synthetic
material, the relative
humidity should be at
least 30 %.
Electrical fast
transient/burst
IEC 61000-4-4
±2 kV for power
supply lines 100 kHz
±1 kV for input/output
lines 100 kHz
±2 kV for power
supply lines 100 kHz
Mains power quality
should be that of a
typical commercial or
hospital environment.
Surge
IEC 61000-4-5
±1 kV line(s) to line(s)
±2 kV line(s) to earth
±1 kV line(s) to line(s)
±2 kV line(s) to earth
Mains power quality
should be that of a
typical commercial or
hospital environment.
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines
IEC 61000-4-11
0 %
U
T (100 % dip in
U
T)
0.5 cycles and
1 cycle
70 %
U
T (30 % dip in
U
T)
25/30 cycles
0 %
U
T (100 % dip in
U
T)
250/300 cycles
0 %
U
T (100 % dip in
U
T)
0.5 cycles and
1 cycle
70 %
U
T (30 % dip in
U
T)
25/30 cycles
0 %
U
T (100 % dip in
U
T)
250/300 cycles
Mains power quality
should be that of a
typical commercial or
hospital environment.
If the user of the
model CL-R813
requires continued
operation during
power mains
interruptions, it is
recommended that the
model CL-R813 be
powered from an
uninterruptible power
supply or a battery.
Power
frequency (50/60 Hz)
magnetic eld
IEC 61000-4-8
30 A/m
50 Hz or 60 Hz
30 A/m
50 Hz or 60 Hz
Power frequency
magnetic elds should
be at levels
characteristic of a
typical location in a
typical commercial or
hospital environment.
The product should be
kept at least 15 cm
away from the source
of power frequency
magnetic elds during
use.
NOTE:
U
Tis the a.c. mains voltage prior to application of the test level.

- 9 - ENGLISH
Guidance and manufacturer’s declaration – electromagnetic immunity
The model CL-R813 is intended for use in the electromagnetic immunity environment (Home
healthcare environment dened in IEC 60601-1-2) specied below.
The customer or the user of the model CL-R813 should assure that it is used in such an
environment.
Immunity IEC 60601
test level
Compliance
level
Electromagnetic
environment – guidance
Proximity
electromagnetic
eld from RF
wireless
communication
equipment
(Specied the table
below)
Portable and mobile RF
communications equipment
should be used no closer to any
part of the model CL-R813,
including cables, than the
recommended separation distance
calculated from the equation
applicable to the frequency of the
transmitter.
Conducted RF
IEC 61000-4-6
3 V
0.15 MHz to 80 MHz
6 V
ISM bands and
amateur radio
between
150 kHz and 80
MHz
80 % AM at 1 kHz
3 V
0.15 MHz to 80 MHz
6 V
ISM bands and
amateur radio
between
150 kHz and 80
MHz
80 % AM at 1 kHz
Recommended separation
distance
d
= 1.2
Radiated RF
IEC 61000-4-3
10 V/m
80 MHz to 2.7 GHz
10 V/m
80 MHz to 2.7 GHz
d
= 1.2 80 MHz to 800 MHz
d
= 2.3 800 MHz to 2.7 GHz
Where Pis the maximum output
power rating of the transmitter in
watts (W) according to the
transmitter manufacturer and
d
is
the recommended separation
distance in meters (m).
Field strengths from xed RF
transmitters, as determined by an
electromagnetic site survey, a
should be less than the
compliance level in each frequency
range. b
Interference may occur in the
vicinity of equipment marked with
the following symbol:

- 10 -
ENGLISH
NOTE 1
U
Tis the a.c. mains voltage prior to application of the test level.
NOTE 2 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 3 Guidelines regarding conducted disturbances induced by RF elds or radiated RF elds
may not apply in all situations. Electromagnetic propagation is aected by absorption
and reection from structures, objects and people.
NOTE 4 The IBM (industrial, scientic and medical) bands between 0.15 MHz and 80 MHz are
6.765 MHz to 6.795 MHz; 13.553 MHz to 13.567 MHz; 26.957 MHz to 27.283 MHz; and
40.66 MHz to 40.70 MHz. The amateur radio bands between 0.15 MHz and 80 MHz are
1.8 MHz to 2.0 MHz, 3.5 MHz to 4.0 MHz, 5.3 MHz to 5.4 MHz, 7 MHz to 7.3 MHz, 10.1
MHz to 10.15 MHz, 14 MHz to 14.2 MHz, 18.07 MHz to 18.17 MHz, 21.0 MHz to 21.4
MHz, 24.89 MHz to 24.99 MHz, 28.0 MHz to 29.7 MHz and 50.0 MHz to 54.0 MHz.
a Field strengths from xed transmitters, such as base stations for radio (cellular/cordless)
telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV
broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic
environment due to xed RF transmitters, an electromagnetic site survey should be
considered. If the measured eld strength in the location in which the model CL-R813 is used
exceeds the applicable RF compliance level above, the model CL-R813 should be observed to
verify normal operation. If abnormal performance is observed, additional measures may be
necessary, such as reorienting or relocating the model CL-R813.
b Over the frequency range 150 kHz to 80 MHz, eld strengths should be less than 10 V/m.

- 11 - ENGLISH
Recommended separation distances between
portable and mobile RF communications equipment and the model CL-R813
The model CL-R813 is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The customer or the user of the model CL-R813 can help prevent
electromagnetic interference by maintaining a minimum distance between portable and mobile
RF communications equipment (transmitters) and the model CL-R813 as recommended below,
according to the maximum output power of the communications equipment.
Immunity to proximity elds from following RF wireless communication equipment has been
conrmed:
Test
frequency
(MHz)
Bandwidtha)
(MHz) Servicea) Modulationb)
Maximum
power
(W)
Minimum
separation
distance
(m)
IEC/EN
60601
test level
(V/m)
Compliance
level
(V/m)
385 380-390 TETRA400 Pulse
modulationb) 1.8 0.3 27 27
450 430-470 GMRS 460,
FRS 460
FM
±5 kHz
deviation
1 kHz sine
2 0.3 28 28
710
704-787 LTE Band
13, 17
Pulse
modulationb)
217 Hz
0.2 0.3 9 9745
780
810
800-960
GSM 800 /
900,
TETRA 800,
iDEN 820
CDMA 850,
LTE Band 5
Pulse
modulationb)
18 Hz
2 0.3 28 28871
930
1720
1700-1990
GSM 1800;
CDMA
1900;
GSM 1900;
DECT;
LTE Band 1,
3, 4, 25;
UMTS
Pulse
modulationb)
217 Hz
2 0.3 28 28
1845
1970
2450 2400-2570
Bluetooth,
WLAN,
802.11 b/g/
n,
RFID 2450,
LTE Band 7
Pulse
modulationb)
217 Hz
2 0.3 28 28
5240
5100-5800 WLAN
802.11 a/n
Pulse
modulationb)
217 Hz
0.2 0.3 9 95500
5785
a): For some services, only the uplink frequencies are included.
b): The carrier shall be modulated using a 50 % duty cycle square wave signal.

- 12 -
ENGLISH
The model CL-R813 is intended for use in an electromagnetic environment in which radiated RF
disturbances are controlled. The customer or the user of the model CL-R813 can help prevent
electromagnetic interference by maintaining a minimum distance between portable and mobile
RF communications equipment (transmitters) and the model CL-R813 as recommended below,
according to the maximum output power of the communications equipment.
Rated maximum
output power of
transmitter
W
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHz
d
= 1.2
80 MHz to 800 MHz
d
= 1.2
800 MHz to 2.7 GHz
d
= 2.3
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
For transmitters rated at a maximum output power not listed above, the recommended
separation distance
d
in meters (m) can be estimated using the equation applicable to the
frequency of the transmitter, where
P
is the maximum output power rating of the transmitter in
watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is
aected by absorption and reection from structures, objects and people.
NOTE 3 The screen of EUT ickers during testing, but it is self-recoverable after test.
NOTE 4 The EUT was stopped operating during the test, but it is self-recoverable after test.
Cables used for the test Length
AC Power Cord 3.0 m
DisplayPort Cable 3.0 m
DVI Cable 3.0 m
USB Cable 3.0 m

- 13 - ENGLISH
Label
Important Please read the label containing warnings and cautions carefully before use.

- 14 -
ENGLISH
Explanation of symbols
These following symbols and labels indicate meanings as below.
Caution Mark
Indicates the monitor is approved according to the UL
& c-UL regulations
This device complies with the requirements of the
European Medical Device Regulation (EU) 2017/745
(“MDR”)
Indicates this device complies with the requirements of
The Medical Devices Regulations 2002 (SI 2002 No 618,
as amended) (UK MDR 2002)
Indicates compliance with Part 15 of the FCC rules
(Class B)
VCCI Notice (Japan Only)
Indicates the compliance to the Class B product based
on the standard of the Voluntary Control Council for
Interference (VCCI)
Indicates compliance with EMC standards of Oceania
Indicates this apparatus must be recycled, according to
the European WEEE directive
Symbol for “MANUFACTURER”
Symbol for “AUTHORIZED REPRESENTATIVE IN THE
EUROPEAN COMMUNITY”
Consult the operating instructions
Indicates this is a medical device
Symbol for "UK Responsible Person"
AC Input
Stand-by ON/OFF
Main Power On
Main Power O

- 15 - ENGLISH
Safety precautions
This manual contains important warnings and information to prevent potential personal
injury and property damage. The symbols and signs used in this manual and their
meanings are as follows.
Symbols
Warning
Indicates a hazard which, if not avoided, could result in death or
serious injury.
Caution
Indicates a hazard which, if not avoided, could result in minor or
moderate personal injury or property damage.
Meanings
Calls your attention to warnings or cautions. This sign may contain a
picture of a specic situation.
E.g.) risk of electric shock
Indicates a banned action. This sign may contain a picture of a
specic situation.
E.g.) no disassembly
Indicates you must follow the instructions. This sign may contain a
picture of a specic situation.
E.g.) Unplug from the wall outlet
Other signs
Important Contains very important information. Make sure to read it before use.
Note Contains do’s and don’ts.
Provides helpful information.
Indicates reference.

- 16 -
ENGLISH
Warning
Do not disassemble, repair, or alter the monitor. It could cause re, electric
shock, or injury. Servicing of such a monitor may be refused. Or a fee may
be charged even within the warranty period. Ask your dealer for repairs.
Do not continue using the monitor when failure or abnormality is found. It
could cause re or electric shock.
Do not touch or swallow the liquid crystal that may leak from the damaged
panel. It could cause skin irritation. If it gets into the eye, ush the eye with
water and call your doctor. If it adheres to skin or clothes, wash it o
immediately with water. It contains a stimulating substance.
Do not put anything on top of or over the monitor. It could cause the
monitor to fail or cause re.
Do not put anything over the cables. It could cause the monitor to fail or
cause re.
Do not handle the monitor with wet hands. It could cause the monitor to
fail or cause electric shock.
No modication of this equipment is allowed.
Do not modify this equipment without authorization of the manufacturer.
If this equipment is modied, appropriate inspection and testing must be
conducted to ensure continued safe use of the equipment.
To avoid risk of electric shock, this equipment must only be connected to a
supply mains with protective earth.
AC power inlet is considered as Disconnect Device.
Double pole, neutral fusing. Disconnect mains before servicing.
If smoke or odor is observed, turn o and unplug the monitor immediately.
Continual use could cause re or electric shock. Consult your dealer.
If by accident you drop the monitor or give it a jolt, turn o and unplug the
monitor immediately. Continual use could cause re or electric shock.
Consult your dealer.

- 17 - ENGLISH
If liquid or any foreign object enters inside, turn o and unplug the
monitor immediately. Continual use could cause re or electric shock.
Consult your dealer.
To avoid a lighting strike, stop using the monitor during thunder. It could
result in electric shock.
Make sure to use the supplied power cable. The use of a cable other than
supplied could cause the monitor to fail.
The input voltage for this monitor is limited to AC 100 V to AC 240 V. Do
not use it at any other voltage. Failure to do so could cause the monitor to
fail or cause re.
The monitor must be grounded. Failure to do so could cause electric shock.
When using a 2P plug, ground the monitor before plugging into a wall
outlet. To remove the grounding cable, unplug the monitor rst.
Follow the instructions below in handling the power plug.
• Hold the plug when unplugging. Pulling the cord could cause damage
and result in re or electric shock.
• Do not plug/unplug with wet hands. It could cause electric re.
• Dust the plug periodically and keep it dust-free to avoid re or electric
shock.
• Do not overload wall outlets. It could cause re or electric shock.
• Do not put things around the monitor. Keep enough space around for
easy access to the plug
Turn o and unplug the monitor and its peripheral devices when installing,
uninstalling, and/or moving the monitor.
This monitor and its components come in plastic bags. Keep out of reach
of children. Playing with plastic bags could cause suocation.
Caution
Install the monitor indoors. It is not designed for the use outdoors or
aboard vehicles.
Do not put the monitor in a stuy, dusty, humid place. Do not expose it to
oily smoke or steam. It could cause the monitor to fail and cause re or
electric shock.
Do not put the monitor on an unstable surface. It could cause the monitor
to fall and result in injury.
Do not expose the monitor to direct sunlight. It could damage the cabinet
or other parts and result in overheat or re.

- 18 -
ENGLISH
Avoid a place subject to
• Magnetic elds • Vibrations
• Corrosive gases • Electrostatic charge
It could cause the monitor to fail.
Do not use the monitor with condensation on the surface. It could cause
the monitor to fail. Condensation forms when the monitor is moved into a
warm room from a cold place. Let it sit until it goes away.
Do not place the monitor on its back or use in a place with little ventilation.
Heat could build up and damage the cabinet and/or the inner parts. It
could result in shortening of life, overheat, and/or re.
Rest your eyes for 10 to 15 minutes per hour. Failure to do so could cause
eyestrain.
Disconnect the power cord if abnormalities such as smoke and re, etc. are
observed. Do not position the monitor so that it is dicult to operate the
disconnection.
This product can be reused only if it is reconditioned under our
responsibility.
Please report to us and the authority of the member state if in any serious
incident that has occurred in relation this product.
LCD
Even if it is used properly, the monitor may cause harmful interference to
radio or television reception. Try the following measures to correct it.
• Increase the distance between the monitor and the radio/TV.
• Connect the monitor into a dierent outlet from the one to which the
radio/TV is connected.
Do not press, scratch, or put objects on the LCD panel surface. It could
cause monitor noise and/or cause the panel to fail.
Do not display a static image for too long. It could cause “ghosting”, a
phenomenon where the previous image displayed on the screen is seen
for moments after the image has changed.
Turn on a screensaver or enable the stand-by mode to avoid “burning in”,
the burning of an image onto the LCD panel after hours of the same image
being displayed.

- 19 - ENGLISH
Please be advised that the following symptoms may occur due to the
nature of LCDs. They are not failures.
• During use in cold environments, “streaking” may occur or images may
appear dark.
• Depending on use conditions such as temperature, spots or unevenness
in luminance or color may be observed.
• Due to the manufacturing technology used, there may be pixel or dot
failures even though its rate of eective pixels is 99.999301 %.
Do not set maximum luminance or closer to it when using the monitor in a
dim room below 100 lx. It could cause eyestrain. We recommend the
factory default. Setting it too low could makes it hard to see the image.
Clean inside of the monitor once a year. The dust could cause re.
Ask your dealer for maintenance.
Mounting orientation is landscape only.
Product Security
This product is operated by the dedicated microcomputer system.
To delete or alter the program could lead to abnormal display.
When this product is controlled by a computer, do not unplug the USB
cable connected to this product.
Connection to IT-Network
・
Connecting to IT-Network could cause unexpected risks.
・
Changing the connection to IT-Network could cause occur new risks.
・
“Changes in the IT-Network” includes “change conguration”, “add
devices”, “detach devices”, and “update devices”.
・
Specify these risks, and execute the risk management.
In order to use this product in a secure state, please apply the following
security measures to the workstation connected to this product.
・
Install anti-virus software
・
Enable rewall and control communication ports

- 20 -
Package contents
Please check if the following items are included in this product package. If any item is
missing, contact your dealer for replacement.
Note Don’t use the power cord packaged with this product for other electronics.
□Monitor □Power cord (3.0 m)
*Power cords vary depending on destination.
3P: For the U.S. 2P: For Europe
□DisplayPort cable ×2
(DP–DP)( 3.0 m)
□USB cable
(3.0 m)□DVI cable (DVI–DVI)
(3.0 m)
□Instruction manual ×1
(English/Japanese)
□Utility disk *
* Utility disk
This product is packed with “Utility disk”.
Functions such as calibration, display of test patterns and so on can be done by
installing this disk, “QA Medivisor Agent LE”, to your PC.
Please refer to the manual on the disk for its usage and the installation method.
Keep the original box and packing material to pack the product for
shipping.
ENGLISH
Table of contents
Other JVC Monitor manuals

JVC
JVC TM-H1750CG User manual

JVC
JVC GD-F65L1 User manual

JVC
JVC NV-PD4200 Administrator Guide

JVC
JVC DT-V20L3DY - VȲitǠSeries Studio... User manual

JVC
JVC DT-V9L5 User manual

JVC
JVC DT-V1710CG User manual

JVC
JVC LCT2505-001A-H User manual

JVC
JVC ProHD DT-X71FI User manual

JVC
JVC TM-923U - High Resolution B/w Monitor User manual

JVC
JVC TM-1051DG Quick start guide

JVC
JVC TM-L450TU - Lccs Color Monitor User manual

JVC
JVC GM-H40L1G/E User manual

JVC
JVC DT-V1900CG/E User manual

JVC
JVC LT-42N5125A User manual

JVC
JVC TM-A170G User manual

JVC
JVC KW-V820BT User manual

JVC
JVC KV-M700 - 6.4 TFT MONITOR Mounting instructions

JVC
JVC KV-MH6510 User manual

JVC
JVC LT-50N530Z User manual

JVC
JVC GD-17L1G Quick start guide