Use
Water indicator
1 Normal operation The indicator will ash red once every
60seconds. Action: ---
2 Water detection
The alarm will sound and the indicator will
ash red continuously until the water is
eliminated.
Action: Eliminate
the water.
3 Low-battery warning The alarm will beep and the indicator will
ash red once every 60seconds.
Action: Replace the
battery.
Testing the alarm
The alarm must be tested monthly to ensure correct operation.
1. Put one nger on each sensing probe to cause a short circuit.
The alarm will sound and the indicator will ash red continuously until the test button is released.
Alarm sound: 3 short beeps, 2 seconds pause (repeated).
2. Remove your ngers from the sensing probes.
Adjusting the sensing probes
The sensing probes can be adjusted from 0 mm to 3 mm in height. Use the hex key to adjust the
sensing probe.
A
B
A
B
0-3 mm 0-3 mm
• Turn the sensing probe clockwise to decrease the height.
The water alarm will detect the water later.
• Turn the sensing probe counterclockwise to increase the height.
The water alarm will detect the water sooner.