them on the hood; extend the upper flue to the ceiling and secure with the 2 screws H (Fig. 11). - Install the charcoal
filter fitting the two filter clips in their housings (Fig. 16) and turning the filter upward.
OPERATION
DESCRIPTIONOFTHEKEYSANDFUNCTIONS(Fig.17):
The appliance is equipped with a completely automatic system (Advanced Sensor Control) capable to manage
all the functions of your hood. Thanks to the ASC, the air in the kitchen is costantly clean and odour free
without any manual intervention. The advanced sensor catches all sort of vapours, smokes and odours caused
by the cooking process. The ASC also captures an abnormal presence of GAS. To access this function, press
the key “A” (see point 1 of the instructions).
Thehood also featuresnumerousother functionsthatyou can chooseaccording to yourneeds and preferences.
Using the “MENU” key, you can access the selection methods, and pressing the - and + keys you can search
forthefunctionyouwanttoactivate(thefunctionflasheson the display); once you have madeyourselection,activate
it by pressing “ok”. To exit from the Menu, press the “MENU” key again.
To activate/disactivate the hood motor, press the - key (or + key) and select the desired speed.
List of the functions on the Menu :
-MINUTECOUNTER WITHBUZZER:Thehoodisequippedwithaminutecounterthatemitsan acousticsignalwhen
the time has elapsed. To activate this function, see point 3 of the instructions.
- TIMER: The hood is equipped with a device for automatic stop after 5 (or 10) minutes. To activate this function, see
point 4 of the instructions.
-CLOCK:thetimecanbeshownonthedisplay.Toactivatethisfunctionorsetthetime,seepoint5ofthe instructions.
- SENSOR SENSITIVITY: You can adjust the sensitivity of the sensor according to your specific needs. To access
this function, see point 6 of the instructions.
-INSIDETEMPERATUREINDICATION:Theinsidetemperatureoftheroomcanbeshownonthedisplay.Toactivate
this function, see point 7 of the instructions.
-OUTSIDETEMPERATUREINDICATION(optional):Itispossibletohavetheoutsidetemperatureshownonthedisplay.
To activate this function, see point 8 of the instructions.
- GREASE FILTER CLEANING INDICATION: The hood signals when it is time to clean the grease filters. See point 9
of the instructions.
-CHARCOALFILTERREPLACEMENTINDICATION:Thehoodsignalswhenitistimetoreplacethecharcoalfilters(for
appliances in the filtering version). See point 10 of the instructions.
1. Key“A” (ASCfunction) :To activate the sensor function, press key “A”. Withthesensor activated, thehoodswitches
on automatically in the presence of any type of odour, steam, smoke, or heat from the cooking process, and also in the
presence of any anomalous gas leaks in the environment. When the sensor is active, the display shows the symbol .
To disactivate the sensor, press the key A. With the sensor activated, pressing the - key or the + key takes you directly
to the manual function and the symbol is shown.
2. Key : Light On/Off.
3. Minute counter: To activate the counter, press the “MENU” key (the symbol appears on the display), then press
“ok”. The display shows the number 00.00 blinking. Using the - and + keys you can set the desired number of minutes
(from 1 to 99); keeping the - or + key pressed, the number of minutes scrolls rapidly. Press “ok” to confirm, then press
“MENU”toexit.Whentheminuteshaveelapsed,anACOUSTICSIGNALisemittedandtheindicationblinksonthedisplay:
press “ok” to disactivate it (otherwise, it is disactivated automatically after 5 minutes).
To disactivate the counter at any moment, press the “MENU” and “ok” (reset) keys together.
4. Timer: When the timer is activated, the hood stops automatically after 5 minutes (or 10). To activate the timer, press
the “MENU” key and then the - and + keys until the blinking symbol appears on the display; confirm by pressing “ok”.
You can select the timer for 5 or 10 minutes by pressing the - and + keys, and then press “ok” to confirm. To exit from
the menu, press the “MENU” key.
5. Clock: To activate the clock function and set the time, press the “MENU” key and then the - and + keys until the 4
digits appear on the display blinking; set the time using the - and + keys, then confirm with “ok”. To exit from the menu,
press the “MENU” key. To disactivate the clock function, press the “MENU” and “ok” (reset) keys together.
6. Sensor sensitivity: To adjust the sensitivity of the sensor, press the “MENU” key and then the - and + keys until the
symbol blinks on the display. Then press “ok”, select the sensitivity from 1 to 9 using the - and + keys and confirm
with “ok”. To exit from the menu, press the “MENU” key”.
7.Insidetemperature indication: To viewtheinside temperature onthedisplay,press the “MENU”keyandthen the -key
(or+key)untilthedisplayshows“In18°C”orsimilar;thenpress“ok”.Theinsidetemperatureismeasuredbyameasuring
device (included) which can be positioned anywhere in the room.
8. Outside temperature indication (optional): To view the outside temperature on the display, press the “MENU” key and
thenthe-key(or+key)untilthedisplayshows“Out15°C”orsimilar;thenpress“ok”.Theoutsidetemperatureismeasured