Kane INF165C User manual

INSTRUCTION MANUAL
ENGLISH
12:1 Infrared Thermometer
SUBCHAPTER J
COMPLIES WITH FDA 21 CFR
LASER RADIATION- AVOID
DIRECT EYE EXPOSURE
CLASS llla LASER PRODUCT
LASER RADIATIONWHEN OPEN
DANGER
®
®
INF165C
www. .com information@itm.com1.800.561.8187

TABLE OF CONTENT
Important Safetey Warnings
Symbol
Functions
Features
Overview
Operating Instructions
Specications
Storage
Warranty
Disposal
Cleaning
3
4
4
4
5
6
7
7
8
8
8
www. .com information@itm.com1.800.561.8187

3
IMPORTANT SAFETEY WARNINGS
WARNING
Read entire Safety Notes section regarding potential hazard and
proper instructions before using this tester. In this manual the
word “WARNING” is used to indicate conditions or actions that may
pose physical hazards to the user. The word “CAUTION” is used to
indicate conditions or actions that may damage this instrument.
WARNING
To ensure safe operation and service of the tester, follow these
instructions. Failure to observe these warnings can result in severe
injury or death.
WARNING
Do not use the tester if it appears damaged.
CAUTION
• When device is in use, DO NOT look directly into the laser.
Permanent eye damage may result.
• Use extreme caution when operating the laser.
• Never point the tester towards anyone’s eyes.
• Keep out of the reach of children.
WARNING
EMC/RFI
Readings may be affected if the tester is operated within a radio
frequency electromagnetic eld strength of approximately 3 volts
per meter, but performance of the tester will not be permanently
affected.
NOTE: Under the electromagnetic eld of 3M/m from 350MHz to
550MHz, the EMC/RFI error is 8˚C (14.4˚F).
www. .com information@itm.com1.800.561.8187

4
SYMBOLS
FUNCTIONS
FEATURES
• Temperature range: -76˚ to 1022˚F (-60° to 550°C)
• 12:1 Distance-to-spot ratio
• Circular laser targeting
• Max value capture
• Emissivity: Fixed 0.95
• Auto power off
Low battery
Degrees fahrenheit
Degrees Celsius
www. .com information@itm.com1.800.561.8187

5
SUBCHAPTERJ
COMPLIESWITH FDA 21 CFR
LASERRADIATION - AVOID
DIRECTEYE EXPOSURE
CLASSllla LASER PRODUCT
LASERRADIATION WHEN OPEN
LOCK
DANGER
Lock
Mode
SUBCHAPTERJ
COMPLIESWITH FDA 21 CFR
LASERRADIATION - AVOID
DIRECTEYE EXPOSURE
CLASSllla LASER PRODUCT
LASERRADIATION WHEN OPEN
LOCK
DANGER
Lock
Mode
SUBCHAPTERJ
COMPLIESWITH FDA 21 CFR
LASERRADIATION - AVOID
DIRECTEYE EXPOSURE
CLASSllla LASER PRODUCT
LASERRADIATION WHEN OPEN
LOCK
DANGER
Lock
Mode
OVERVIEW
A. Display: Press Trigger + Lock button for backlight ON/OFF
function.
• MAX reading will be displayed during measurement.
B. ˚C /˚F Button: Press repeatedly to switch between ˚C and ˚F.
Press when tester is off to recall memory of last test.
C. Mode Button
D. Lock Button: Press Lock Button to extend Auto Power Off to 60
minutes.Default Auto Power Off is 15 seconds.
E. Infrared Lens
F. Laser: Press Trigger + Mode button for laser ON/OFF function.
G. Trigger: Initiates measurements (turns on Laser).
H. Battery Cover
A. E.
F.
G.
H.
B. D.
C.
SUBCHAPTERJ
COMPLIESWITH FDA 21 CFR
LASERRADIATION - AVOID
DIRECTEYE EXPOSURE
CLASSllla LASER PRODUCT
LASERRADIATION WHEN OPEN
DANGER
®
www. .com information@itm.com1.800.561.8187

6
OPERATING INSTRUCTIONS
ERROR MESSAGES
The thermometer incorporates visual diagnostics messages as
below:
ER2: is displayed when the thermometer is exposed to rapid
changes in ambient temperatures.
ER3: is displayed when the ambient temperature exceeds 32˚F
(0˚C) or 122˚F (50˚C).The tester should be allowed plenty of time
to stabilize in the working temperature.
ER5-ER9: For all other errors it is necessary to reset the thermom-
eter. To reset, turn the tester off, remove the batteries, wait for a
minimum of one minute, reinsert the batteries and turn the tester
back on. If the error remains, contact the UEi Service Center.
Hi/Lo: is displayed when measured temperature exceeds the
measurement temperature range in the specication section of this
manual.
Battery Replacement
When the batteries are too low for safe operation, the Low Bat-
tery indicator will display.
• Slide the battery cover off the tester.
• Replace the batteries (AAA) 2.
• Replace battery cover.
www. .com information@itm.com1.800.561.8187

7
Temperature Range -76˚ to 1022˚F (-60˚ to 550˚C)
Operating Temperature 32˚ to 122˚F (0˚ to 50˚C)
Accuracy
(Tobj=15-35˚C,
Tamb=25˚C)
± 2.7˚F (1.5˚C)
Accuracy
(Tamb=23 ± 3˚C)
Tobj=0~550˚C: ±2% of reading or
2˚C(4˚F) whichever is greater
Tobj=-60~0˚C: ±(2˚C+0.05/degree C)
Emissivity Fixed 0.95
Resolution (-9.9˚ to 199.9˚ C/F) 0.2˚C (0.5˚F)
otherwise 1˚ C/F
Response Time 1 sec.
Distance-to-Spot Ratio 12:1
Dimension 6.43" x 4.62" x 1.92"
(163.37 x 117.33 x 48.72mm)
Weight 7.58 oz (215g) including batteries
SPECIFICATIONS
STORAGE
Remove the batteries when instrument is not in use for a prolonged
period of time. Do not expose to high temperatures or humidity.
After a period of storage in extreme conditions exceeding the limits
mentioned in the General Specications section, allow the instru-
ment to return to normal operating conditions before using it.
www. .com information@itm.com1.800.561.8187

WARRANTY
The INF165C is warranted to be free from defects in materials
and workmanship for a period of 1 year from the date of purchase.
If within the warranty period your instrument should become
inoperative from such defects, the unit will be repaired or replaced
at Kane’s option. This warranty covers normal use and does not
cover damage which occurs in shipment or failure which results
from alteration, tampering, accident, misuse, abuse, neglect or
improper maintenance. Batteries and consequential damage
resulting from failed batteries are not covered by warranty. Any
implied warranties, including but not limited to implied warranties of
merchantability and tness for a particular purpose, are limited to
the express warranty. Kane shall not be liable for loss of use of the
instrument or other incidental or consequential damages, expens-
es, or economic loss, or for any claim or claims for such damage,
expenses or economic loss. A purchase receipt or other proof of
original purchase date will be required before warranty repairs will
be rendered. Instruments out of warranty will be repaired (when
repairable) for a service charge.
This warranty gives you specic legal rights. You may also have
other rights, which vary from state to state.
DISPOSAL
Caution: This symbol indicates that equipment and
its accessories shall be subject to separate collection
and correct disposal.
CLEANING
Periodically clean your meters’ case using a damp cloth. DO NOT
use abrasive, ammable liquids, cleaning solvents, or strong de-
tergents as they may damage the nish, impair safety, or affect the
reliability of the structural components.
Copyright © 2021 Kane USA Inc. All Rights Reserved. 09/21
www. .com information@itm.com1.800.561.8187
Table of contents