Kathrein FKP 100 User manual

1
1
User Manual
FKP 100
2220000007
Keypad

2
Introduction
Thank you for purchasing the KATHREIN Digital Systems GmbH keypad. Please take
the time to read the following safety and installation information carefully and
attentively before using the keypad. It is imperative to comply with these instructions
in order to ensure the safe operation of the device. If you have any further questions,
please contact your local retailer or KATHREIN Digital Systems GmbH directly. Your
keypad FKP 100 was developed and built with state-of-the-art technology and
complies with European and German standards.
Please keep this manual safe to be able to answer possible questions in the future.
The manual is an integral part of the product even in case it is resold to a third party.
Disclaimer
All technical details and descriptions in this manual were compiled with the greatest
care. However, KATHREIN Digital Systems GmbH cannot entirely exclude mistakes in
this manual. Therefore, we do not assume any legal responsibility or liability resulting
from wrong information in this manual. Descriptions, technical illustrations and
technical data are subject to change without notice according to technical progress.
In addition, KATHREIN Digital Systems GmbH reserves the right to change the product
and the manual without prior notice. We do not assume any guarantee with regard to
the content of this document. We appreciate any comments on mistakes or
inaccuracies which may help us to improve this product and this manual.
This symbol is intended to attract the user’s attention to the potential
risk of dangerous unprotected voltage inside the housing. This may
lead to electric shock.
This symbol is intended to attract the user‘s attention to user and
maintenance instructions in the manual and documents enclosed
with the product.

3
WARNING:
TO MINIMISE THE RISK OF ELECTRIC SHOCK, YOU MUST NOT EXPOSE THIS PRODUCT
TO WET AND MOIST CONDITIONS AT ANY TIME.
All KATHREIN Digital Systems GmbH products are lead-free and meet
the requirements stated under the European Directive on the
Restriction of Hazardous Substances (RoHS). This guarantees that
the entire production process and the product itself are free of lead
and of all listed hazardous substances.
This product was tested and complies with the regularities for a class
of
digital devices stated under FCC part 15. These limits were
specified to provide reasonable protection against harmful exposure
when operating the device in a commerci
al environment. This
product generates, uses and
may emit radio energy. It may in
addition interfere with other radio
communication systems if not
installed or used according to this manual.
Using the device in
residential areas may cause disturbances to be possibly remedied at
the user’s expense.
Hereby KATHREIN Digital Systems GmbH declares that the keypad
FKP 100 (order number 2220000007, EAN 4021121548840) is in
conformity with the relevant provisions of Directive 1999/5/EG.
Conformity:
The declaration of conformity is available at http://www.kathrein-ds.com in
the download section of the respective product. Alternatively, you can
request the declaration of conformity directly from us:
KATHREIN Digital Systems GmbH
Anton-Kathrein-Str. 1–3
83022 Rosenheim, Germany

4
Important Safety Information
WARNING
The warranty claim will expire in case of damages resulting from the
non-observance of this manual.
We do not assume any liability for consequential damages.
We do not assume any liability for damages to persons and/or
material whatsoever which result from improper handling or
noncompliance with the safety instructions. The warranty claim
will expire in such cases!
The keypad FKP 100 is equipped with a high-quality housing. However, please observe
the following safety instructions:
•Operate the keypad only with the provided batteries.
•Handle the keypad with care, heavy vibration or bumps may damage the
device.
•Do not expose the keypad to direct sunlight or strong heat, e.g. heaters.
•Do not install the keypad close to strong electric power lines or magnetic
fields, as this may impair the transmission quality significantly.
•Do not install the keypad directly on iron or aluminium surfaces, as this
may impair the wireless transmission significantly. Use a non-conducting
material to insulate the device from the installation surface.
•Do not install the keypad in moist, very cold or very hot environments.
•Persons (including children) with limited physical, sensory or mental
abilities and/or lacking experience and/or knowledge must not use this
product.
•Keep children away from the product and other connected electrical
appliances at all times. The keypad includes small parts they can swallow.
Lay cables expertly so that they are neither bent nor otherwise damaged.
Install the keypad out of children’s reach. Do not leave packaging
materials unattended, as they may be dangerous for playing children.
•Use a damp cloth to clean the keypad’s surface, then dry it. Cleaning
agents will damage the surface.

5
Malfunctions and Defects
If you notice any kind of defect, remove the batteries from the keypad FKP 100 and
contact your retailer or KATHREIN Digital Systems GmbH directly. Any further usage
of the system may lead to fire or electric shock!
Intended Use
The KATHREIN Digital Systems GmbH keypad is designed to alert you acoustically in
case of alarm. Use the keypad FKP 100 indoors only. Any other use than that described
in this manual is not permitted and will void any warranty or guarantee as well as
liability claims. The same applies if the device is modified or retrofitted.
Disposal
Do not dispose of the device with domestic waste!
This product complies with the EU Directive on waste electrical and
electronic equipment (WEEE) and therefore must not be disposed of
with domestic waste. Dispose of the device via your local collection
point for waste electronic equipment!
This product contains software programs subject to the GPL free software license.
This product contains software that was developed by third parties and/or software
subject to the GNU General Public License (GPL) and/or the GNU Lesser General
Public License (LGPL). We will send you the source code of these programs on request.
The GPL and/or LGPL code used and offered in this product is EXCLUSIVE OF ANY
GUARANTEE WHATSOEVER and is subject to the copyright of one or several authors.
For further details, please refer to the GPL and/or LGPL code of this product and to
the terms of use of GPL and LGPL.
You can read the complete license text at http://www.gnu.org/licenses/gpl-2.0.html.
For an unofficial German translation, please go to
http://www.gnu.de/documents/gpl.de.html.

6
Keypad FKP 100
Product description:
1. Power LED
2. Status LED
3. Error LED
4. Arm
5. Home
6. System status
7. Disarm
8. Pound key #
9. Star key *
Installation mode = Installation PIN + *
10. Emergency alarm: 7 + 9 (simultaneously)
11. Fire alarm: 4 + 6 (simultaneously)
12. Panic alarm: 1 + 3 (simultaneously)
13. Battery insulation tab (delivery status)
14. Mounting holes
15. Tamper contact
Please note:
•The dual-key commands 1+3 (12.), 4+6 (11.), 7+9 (10.) are disabled by default.
•To use dual key functions, only press the two corresponding buttons on
the keypad. Do not press any other buttons.
LED indicators:
•Power LED:
oLED lights up orange: test mode is
active
oLED flashes orange: test mode is
active + low battery
oLED lights up blue for approx. five
seconds: System status is normal
oLED flashes blue: Low battery
Notes:
•Normally all LEDs are off.
•If you press any key, the power LED will
light up blue for five seconds. This signals that the keypad is operational.

7
•Status LED
(allows you to check the status of the alarm panel):
If you press the status button of the keypad, the status LED will display
the current status of the alarm panel:
LED lights up red: alarm panel is in arm mode
LED flashes red: alarm panel is in home mode
LED lights up blue: alarm panel is in disarm mode
LED flashes blue: an error occurred, e.g.:
oAlarm panel does not respond
oIncorrect PIN code
oAttempted to switch to home mode while the alarm panel is in arm
mode
oForced activation of arm mode while alarm panel or sensors report an
error
•Error LED:
LED flashes orange: system error, e.g.:
oNo SIM card
oGSM not ready
oTamper contact is open
oPower failure
oSensor is out of range
oSensor is open
oBattery of a sensor is low
oWhen disarming, there is still an alarm in the alarm memory.
•Battery:
The keypad requires a CR123A 3V lithium battery. The average battery life is
two years. If the battery is low, the orange status LED flashes.
Connecting the keypad and putting it into operation
Installation of the keypad:
1. Remove the front cover of the keypad by unscrewing the screw at the bottom.
2. At the back cover you find two cavities. They are intended to be pierced –
thus, you can mark the locations for required drill holes for a wall installation.
3. Use screws to install the keypad on a wall.
4. Attach the front cover again.

8
Connecting the keypad to the alarm panel:
1. Enter the installation mode of the keypad by entering the installation PIN
(default: 0000) and pressing the * button. The power LED will light up orange.
2. Open the web interface of the alarm panel, go to the menu “Sensors” “Add”
and press “Start”.
3. Press * and then 7 on the keypad. The keypad emits a signal and will be listed
in the alarm panel.
•If you do not hear a signal, the alarm panel did not receive the connection
request of the keypad.
•If the connection request was received by the alarm panel, you will hear
three short signal sounds.
4. Add the keypad to the alarm panel by pressing “Add” next to the keypad in
the menu “Sensors” “Add”.
5. To exit the installation mode, press the disarm button two times. The
keypad emits a signal sound and the power LED is switched off.
6. Now you can arm and disarm the alarm panel by means of the keypad.
Range test:
To test the signal strength at the desired installation location, perform a range test.
1. Enter the installation mode of the keypad (default: 0000 + *)
2. Open the alarm panel menu “Sensors” “Range” and press “Start.”
3. Press the * + 7.
4. The sensor and the signal strength should be indicated. The higher the
indicated number the better the reception (1-9).
5. To exit the installation mode, press the disarm button two times.
Please note:
If there is no signal at the installation location or the signal strength is below 4 or
frequently falls below this level (signal fluctuations of 2 to 3 are normal), we
recommend using a repeater to improve the signal.
Changing the PIN code to switch between the different modes of the alarm panel:
You can change the PIN code in the web interface of the alarm panel. Open the menu
“Home” “Pin codes” and change the existing PIN code or enter a new one.
Controlling the alarm panel by means of the keypad:
1. Arm the alarm panel:
PIN code (default 1234) + arm button (a long signal is emitted + the status
LED lights up).
2. Disarm the alarm panel:
PIN code (default 1234) + disarm button (two signals are emitted + the
status LED lights up blue).
3. Switch to home mode:
PIN code (default 1234) + home button and press 1, 2, or 3 to select the
corresponding home mode (three signals are emitted + the status LED flashes
red). If you do not press any number key after pressing the home button, the
alarm panel will switch to home mode 1.

9
Dual key functions:
The keypad features pre-defined dual key commands that allow you to trigger a fire,
panic, or medical alarm without entering a PIN code. To activate the dual key
functions, please proceed as follows:
Enter the installation mode of the keypad (default 0000 + *). The power LED lights up
orange. To activate the dual key function, you need to enter the following commands
for the corresponding functions:
* + 2 = Activate dual key 1 + 3 panic alarm
* + 3 = Activate dual key 4 + 6 fire alarm
* + 4 = Activate dual key 7 + 9 medical alarm
* + 5 = Deactivate all dual key functions
Notes:
•For using the dual key function it is necessary to press the commands at
least for three seconds.
•To execute the dual commands press always only two keys on the keypad
and no other keys!
Additional functions of the installation mode:
* + 7 = Adding the keypad to the alarm panel / range test
* + 6 = Changing the installation PIN
•Enter the current installation PIN (default 0000).
•Press the status button . A long signal is emitted.
•Enter your new installation PIN code (4-digits).
•Press the pound button (#). The new installation PIN code is now saved.
* + 8 = Enable switching to arm / home mode without entering a PIN code
* + 9 = Disable switching to arm / home mode without entering a PIN code
To exit the installation mode, press the disarm button two times.
Reset / factory default:
If you have forgotten your installation PIN code, you can restore the factory default of
the keypad in the following way:
1. Open the keypad. Be aware that the tamper protection will be triggered!
2. Remove the batteries.
3. Press and hold the button “3” while you are inserting the batteries again.
4. Release the button “3”.
5. After the reset, the installation PIN code will again be 0000.
Notes:
•In the menu “Settings” “Panel” “Area Settings” “Arming with failure”
you can allow that the alarm panel will always switch the mode irrespective
of errors.
•If an error is displayed by a flashing error LED, it can be ignored by entering
the PIN code and the mode command again within ten seconds.
•Current errors are displayed and can be ignored in the menu “Home”
“Status”.
•The keypad transmits its status "only" during input. Although it can be
transmitted that the batteries are getting weak but not that they are empty.

10
•Depending on the used PIN code, the keypad can control both areas.
•In the menu “Settings” “Panel” “General settings” a “PIN code
protection” can be activated. After five incorrect PIN code inputs, the
keypad is locked for 15 minutes.
Change the standard PIN code (1234) as well as the installation PIN
code (0000) of the keypad to ensure that no one else can control
your alarm panel!
You can change the PIN code in the menu “Home” “PIN codes” of
the alarm panel. To change the installation PIN code, see above.

11
For your notes
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________

12
For your notes
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
__________________________________________________
www.kathrein-ds.com | support@kathrein-ds.com 9360000380/b/STM/0321/GB | Subject to change.
KATHREIN Digital Systems GmbH | Anton-Kathrein-Str. 1–3 | 83022 Rosenheim | Germany | Phone +49 731 270 909 70
This manual suits for next models
1
Table of contents