Table of contents
1User instructions............................................................................................................................................... 4
1.1 User guide................................................................................................................................................ 4
1.1.1 Abbreviations............................................................................................................................... 4
1.1.2 Symbols....................................................................................................................................... 4
1.1.3 Target group................................................................................................................................ 4
2Setup methods according to DIN EN ISO 17664............................................................................................. 5
2.1 References............................................................................................................................................... 5
2.2 General instructions for the reprocessing of KaVo treatment units.......................................................... 5
2.2.1 Reprocessing Overview Primus 1058 Life................................................................................... 8
2.3 Reprocessing of the surfaces of treatment unit / upholstery..................................................................... 8
2.4 Preparation of the dentist unit................................................................................................................... 9
2.4.1 Reprocessing of handle and holder pad/anti-slip mat................................................................. 9
2.4.2 Reprocessing of the instrument holder of the TM table............................................................. 11
2.4.3 Reprocessing of the instrument arm S table............................................................................. 12
2.4.4 Setting up the 3-function and multifunction handpiece.............................................................. 14
2.4.5 Preparation of the instrument hoses......................................................................................... 16
2.4.6 Servicing the turbine return air filter........................................................................................... 17
2.4.7 Reprocessing KaVo ERGOcam One......................................................................................... 17
2.5 Reprocessing of the assistant unit.......................................................................................................... 19
2.5.1 Preparing the instrument holder................................................................................................ 19
2.5.2 Preparing the connector for the suction hose............................................................................ 19
2.5.3 Reprocessing of sieve inserts and suction hoses..................................................................... 20
2.6 Preparation of the patient unit................................................................................................................. 20
2.6.1 Preparation of the tumbler......................................................................................................... 20
2.6.2 Preparation of the tumbler holder and filler............................................................................... 20
2.6.3 Preparation of the spittoon........................................................................................................ 22
2.7 Manual reprocessing of the water-conducting system............................................................................ 23
2.8 Automatic hygiene functions of the water conducting system................................................................ 23
2.8.1 Rinsing programme................................................................................................................... 24
2.8.2 Intensive germ reduction........................................................................................................... 27
2.9 Reprocessing and automatic hygiene functions of the suction system.................................................. 30
2.9.1 Reprocessing of the suction system including suction hoses................................................... 30
2.9.2 HYDROclean function............................................................................................................... 31
2.10 Preparation of the amalgam separator................................................................................................... 31
2.11 Reprocessing KaVo Screen One / KaVo Screen HD............................................................................. 32
3Replenish and check the disinfectant............................................................................................................. 33
3.1 Replenish OXYGENAL 6........................................................................................................................ 33
3.1.1 Replenish OXYGENAL 6 when using the water bottle.............................................................. 34
3.2 Check the OXYGENAL 6 concentration................................................................................................. 37
Care instructions Primus 1058 Life
Table of contents
3 / 40