Immediately after use, pump through with hot soapy
water, followed by clean water. This is essential to
ensure blockages do not occur due to a build-up
of residue and to promote the long life of your
instrument.
Remove piston and lubricate ‘O’-ring with medicinal
liquid parafn or Caster oil and ret piston, do not
interchange pistons between syringes as they are
individually calibrated for accuracy.
4. Maintenance
a If you experience difculty when
priming the syringe and vaccine
is not initially drawn through, use
a disposable syringe with a short
piece of PVC tubing attached
to the front stem to draw the
vaccine through.
b The syringe is designed and
built to give a high degree of
accuracy. If accuracy should
fail, check for residual matter
stuck on the valves.
-Unscrew and remove delivery
option. i.e. Rear connector,
multit bottle holder or cap
assembly bottlemount.
-Ensure suction valve and
valve spring are clean and
undamaged and no residual
matter appears in rear connector
or rear of vaccinator.
-Replace parts as in diagram
ensuring correct orientation of
suction valve.
c If after long service there is
leakage from the base of the
handgrip, remove piston and t
new ‘o’ ring and lubricate with
Liquid parafn or Caster oil
before replacing piston.
5. Troubleshooting